International Journal of Nanomedicine 2023Three-dimensional (3D) printing is serving as the most promising approach to fabricate personalized titanium (Ti) implants for the precise treatment of complex bone... (Review)
Review
Three-dimensional (3D) printing is serving as the most promising approach to fabricate personalized titanium (Ti) implants for the precise treatment of complex bone defects. However, the bio-inert nature of Ti material limits its capability for rapid osseointegration and thus influences the implant lifetime in vivo. Despite the macroscale porosity for promoting osseointegration, 3D-printed Ti implant surface morphologies at the nanoscale have gained considerable attention for their potential to improve specific outcomes. To evaluate the influence of nanoscale surface morphologies on osseointegration outcomes of 3D-printed Ti implants and discuss the available strategies, we systematically searched evidence according to the PRISMA on PubMed, Embase, Web of Science, and Cochrane (until June 2022). The inclusion criteria were in vivo (animal) studies reporting the osseointegration outcomes of nanoscale morphologies on the surface of 3D-printed Ti implants. The risk of bias (RoB) was assessed using the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE's) tool. The quality of the studies was evaluated using the Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines. (PROSPERO: CRD42022334222). Out of 119 retrieved articles, 9 studies met the inclusion criteria. The evidence suggests that irregular nano-texture, nanodots and nanotubes with a diameter of 40-105nm on the surface of porous/solid 3D-printed Ti implants result in better osseointegration and vertical bone ingrowth compared to the untreated/polished ones by significantly promoting cell adhesion, matrix mineralization, and osteogenic differentiation through increasing integrin expression. The RoB was low in 41.1% of items, unclear in 53.3%, and high in 5.6%. The quality of the studies achieved a mean score of 17.67. Our study demonstrates that nanostructures with specific controlled properties on the surface of 3D-printed Ti implants improve their osseointegration. However, given the small number of studies, the variability in experimental designs, and lack of reporting across studies, the results should be interpreted with caution.
Topics: Animals; Osseointegration; Osteogenesis; Titanium; Prostheses and Implants; Printing, Three-Dimensional; Surface Properties; Porosity
PubMed: 37525692
DOI: 10.2147/IJN.S409033 -
National Journal of Maxillofacial... 2023Bone metabolism is a key factor for successful osseointegration, and low vitamin D levels may negatively impact the process of osseointegration after implant placement.... (Review)
Review
Bone metabolism is a key factor for successful osseointegration, and low vitamin D levels may negatively impact the process of osseointegration after implant placement. The study was aimed at evaluating the relation of vitamin D levels with dental implant osseointegration and subsequently the success or failure of the implant. The focused questions were-What is the effect of vitamin D levels on successful dental implant osseointegration and what is the effect of vitamin D supplementation on successful implant osseointegration? A search was conducted on PubMed and Google Scholar using the terms "vitamin D," "cholecalciferol," "1,25(OH) D," "dental implant," "osseointegration," and "bone implant contact" for a period of 10 years from 2011 to 2020. Clinical trials, cross-sectional studies, case series, and case reports were included. A total of ten studies were included after the screening process. Five of these studies evaluated the effect of vitamin D supplementation on osseointegration, whereas five only evaluated the effect of vitamin D deficiency on dental implant osseointegration. Only five of these studies reported dental implant failure varying from 7% to 13% in vitamin D deficient/insufficient groups. Positive relationship exists between serum vitamin D levels and dental implant osseointegration; however, few studies failed to report any relation. More prospective clinical research studies as well as randomized controlled trials are needed to show a significant correlation between decreased serum levels of vitamin D and increased risk of dental implant failure in perspective of vitamin D supplementation which can promote the osseointegration of dental implants.
PubMed: 38273924
DOI: 10.4103/njms.njms_192_22 -
The Saudi Dental Journal Mar 2024This review aimed to comprehensively investigate the impact of Hormone Replacement Therapy (HRT) on implant osseointegration and bone loss. The study considered factors... (Review)
Review
BACKGROUND
This review aimed to comprehensively investigate the impact of Hormone Replacement Therapy (HRT) on implant osseointegration and bone loss. The study considered factors such as HRT type, osteoporosis, smoking, and diabetes mellitus, and analysed the available literature to provide insights into the association between HRT and implant outcomes.
METHODS
Multiple databases were utilized, and studies with diverse designs and methodologies were included that examined the relationship between HRT and implant osseointegration. The selected studies were analyzed and relevant data on implant success rates, bone loss, and other correlations was extracted.
RESULTS
The review findings indicate that HRT has a detrimental impact on implant osseointegration, as evidenced by lower implant success rates and increased bone loss in HRT-treated individuals. The odds ratio analysis further strengthens this association, with significant values of 0.59 (95% CI: 0.50-0.70) and 0.64 (95% CI: 0.54-0.76), indicating a higher likelihood of implant failure in HRT-treated patients., highlighting the need for caution when considering HRT as a treatment option in patients undergoing implant procedures. Smoking and diabetes mellitus were also found to significantly affect implant outcomes, emphasizing the importance of addressing these factors in patient management.
CONCLUSION
The assessments demonstrate that HRT adversely affects implant osseointegration and increases bone loss. The results suggest the importance of considering the potential negative impact of HRT on implant outcomes and the need for thorough patient evaluation and management. Further research is warranted to explore the underlying mechanisms, assess the impact of specific HRT types and dosages, and evaluate preventive strategies to mitigate the detrimental effects of HRT on implant success.
PubMed: 38525181
DOI: 10.1016/j.sdentj.2023.10.021 -
International Journal of Molecular... Dec 2023There is increasing interest in using magnesium (Mg) alloy orthopedic devices because of their mechanical properties and bioresorption potential. Concerns related to... (Review)
Review
Magnesium Alloys in Orthopedics: A Systematic Review on Approaches, Coatings and Strategies to Improve Biocompatibility, Osteogenic Properties and Osteointegration Capabilities.
There is increasing interest in using magnesium (Mg) alloy orthopedic devices because of their mechanical properties and bioresorption potential. Concerns related to their rapid degradation have been issued by developing biodegradable micro- and nanostructured coatings to enhance corrosion resistance and limit the release of hydrogen during degradation. This systematic review based on four databases (PubMed, Embase, Web of Science™ and ScienceDirect) aims to present state-of-the-art strategies, approaches and materials used to address the critical factors currently impeding the utilization of Mg alloy devices. Forty studies were selected according to PRISMA guidelines and specific PECO criteria. Risk of bias assessment was conducted using OHAT and SYRCLE tools for in vitro and in vivo studies, respectively. Despite limitations associated with identified bias, the review provides a comprehensive analysis of preclinical in vitro and in vivo studies focused on manufacturing and application of Mg alloys in orthopedics. This attests to the continuous evolution of research related to Mg alloy modifications (e.g., AZ91, LAE442 and WE43) and micro- and nanocoatings (e.g., MAO and MgF2), which are developed to improve the degradation rate required for long-term mechanical resistance to loading and excellent osseointegration with bone tissue, thereby promoting functional bone regeneration. Further research is required to deeply verify the safety and efficacy of Mg alloys.
Topics: Magnesium; Orthopedic Procedures; Orthopedics; Osteogenesis; Alloys
PubMed: 38203453
DOI: 10.3390/ijms25010282 -
Materials (Basel, Switzerland) Sep 2023The current review aims to provide an overview of the most recent research in the last 10 years on the potentials of graphene in the dental surgery field, focusing on... (Review)
Review
The current review aims to provide an overview of the most recent research in the last 10 years on the potentials of graphene in the dental surgery field, focusing on the potential of graphene oxide (GO) applied to implant surfaces and prosthetic abutment surfaces, as well as to the membranes and scaffolds used in Guided Bone Regeneration (GBR) procedures. "Graphene oxide" and "dental surgery" and "dentistry" were the search terms utilized on the databases Scopus, Web of Science, and Pubmed, with the Boolean operator "AND" and "OR". Reviewers worked in pairs to select studies based on specific inclusion and exclusion criteria. They included animal studies, clinical studies, or case reports, and in vitro and in vivo studies. However, they excluded systematic reviews, narrative reviews, and meta-analyses. Results: Of these 293 studies, 19 publications were included in this review. The field of graphene-based engineered nanomaterials in dentistry is expanding. Aside from its superior mechanical properties, electrical conductivity, and thermal stability, graphene and its derivatives may be functionalized with a variety of bioactive compounds, allowing them to be introduced into and improved upon various scaffolds used in regenerative dentistry. This review presents state-of-the-art graphene-based dental surgery applications. Even if further studies and investigations are still needed, the GO coating could improve clinical results in the examined dental surgery fields. Better osseointegration, as well as increased antibacterial and cytocompatible qualities, can benefit GO-coated implant surgery. On bacterially contaminated implant abutment surfaces, the CO coating may provide the optimum prospects for soft tissue sealing to occur. GBR proves to be a safe and stable material, improving both bone regeneration when using GO-enhanced graft materials as well as biocompatibility and mechanical properties of GO-incorporated membranes.
PubMed: 37763569
DOI: 10.3390/ma16186293 -
Cureus Mar 2024Lower limb amputation is a common orthopedic surgery in the United States and can be performed either above or below the knee. Prosthetics are typically externally... (Review)
Review
Lower limb amputation is a common orthopedic surgery in the United States and can be performed either above or below the knee. Prosthetics are typically externally fitted to the patient's residual stump; however, osseointegrated implants offer a potential alternative to this process. Transcutaneous limb osseointegration involves the intramedullary anchoring of an implant that can later attach to a prosthetic via a stoma in the residual limb. There are proposed benefits to this, including decreased skin and soft tissue complications as well as an increased sense of stability. As this is a relatively new procedure, the complications and efficacy are not well supported by the literature at this time. The primary aim of this analysis was to synthesize the currently available data on transfemoral and transtibial osseointegration in order to improve our understanding of the potential complications of the procedure. A literature search was performed in the following databases: Biomedical Reference Collection, CINAHL, Cochrane Library, and PubMed/MEDLINE. Articles were screened by three independent reviewers for studies written or available in English, study design, and study outcomes, including complications. No filter was applied for publication date, publication national origin, or sample size. A total of 20 articles were selected for the final qualitative analysis. This review demonstrates an overall low or non-inferior rate of both minor and severe complications in transtibial and transfemoral osseointegration. This procedure should be considered as an option during preoperative planning in the context of above-the-knee and below-the-knee amputations. However, continued studies with larger sample sizes and extended postoperative follow-up are necessary for a greater strength of recommendation.
PubMed: 38681289
DOI: 10.7759/cureus.57045 -
Cell Biochemistry and Function Mar 2024The demand for efficient and accelerated osseointegration in dental implantology has led to the exploration of innovative tissue engineering strategies. Immediate... (Review)
Review
The demand for efficient and accelerated osseointegration in dental implantology has led to the exploration of innovative tissue engineering strategies. Immediate implant loading reduces treatment duration and necessitates robust osseointegration to ensure long-term implant success. This review article discusses the current studies of tissue engineering innovations for enhancing osseointegration in immediate dental implant loading in the recent decade. Keywords "tissue engineering," "osseointegration," "immediate implant loading," and related terms were systematically searched. The review highlights the potential of bioactive materials and growth factor delivery systems in promoting osteogenic activity and accelerating bone regeneration. The in vivo experiment demonstrates significantly improved osseointegration in the experimental group compared to traditional immediate loading techniques, as evidenced by histological analyses and biomechanical assessments. It is possible to revolutionize the treatment outcomes and patient satisfaction in dental implants by integrating bioactive materials and growth factors.
Topics: Humans; Osseointegration; Immediate Dental Implant Loading; Tissue Engineering; Treatment Outcome; Osteogenesis
PubMed: 38491807
DOI: 10.1002/cbf.3974 -
Laboratory Animals Oct 2023This systematic review aims to identify and discuss the most used methodologies in pre-clinical studies for the evaluation of the implementation of dental implants in... (Review)
Review
This systematic review aims to identify and discuss the most used methodologies in pre-clinical studies for the evaluation of the implementation of dental implants in systemically compromised pigs and sheep. This study provides support and guidance for future research, as well as for the prevention of unnecessary animal wastage and sacrifice. Preferred Reporting for Systematic Reviews and Meta-Analyses (PRISMA) was used as a guideline; electronic searches were performed in PubMed, Scopus, Scielo, Web of Science, Embase, Science Direct, Brazilian Bibliography of Dentistry, Latin American and Caribbean Literature in Health Sciences, Directory of Open Access Journals, Database of Abstracts of Reviews of Effects, and gray literature until January 2022 (PROSPERO/CRD42021270119). Sixty-eight articles were chosen from the 2439 results. Most studies were conducted in pigs, mainly the Göttinger and Domesticus breeds. Healthy animals with implants installed in the jaws were predominant among the pig studies. Of the studies evaluating the effect of systemic diseases on osseointegration, 42% were performed in osteoporotic sheep, 32% in diabetic sheep, and 26% in diabetic pigs. Osteoporosis was primarily induced by bilateral ovariectomy and mainly assessed by X-ray densitometry. Diabetes was induced predominantly by intravenous streptozotocin and was confirmed by blood glucose analysis. Histological and histomorphometric analyses were the most frequently employed in the evaluation of osseointegration. The animal models presented unique methodologies for each species in the studies that evaluated dental implants in the context of systemic diseases. Understanding the most commonly used techniques will help methodological choices and the performance of future studies in implantology.
Topics: Female; Animals; Sheep; Swine; Dental Implants; Models, Animal; Osteoporosis; Osseointegration; Diabetes Mellitus
PubMed: 37021606
DOI: 10.1177/00236772221124972 -
Medicina (Kaunas, Lithuania) May 2024: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets... (Meta-Analysis)
Meta-Analysis Comparative Study Review
: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets with and without periapical pathology. : After the search and review of the literature in the electronic databases, 109 publications were achieved. The titles and abstracts of 66 publications were screened. After the evaluation of the full text of 22 publications, based on the inclusion criteria, six controlled clinical studies were included in this systematic review and meta-analysis. The statistical calculation showed no heterogeneity among the studies included. The implant survival was 99.6% in the test (socket with periapical pathology) and control (socket without periapical pathology) groups of all the clinical trials. The results of the meta-analysis showed no statistically significant difference between test and control groups regarding the marginal bone level and the width of keratinized mucosa in all the studies. Other parameters indicating plaque level, bleeding on probing, and gingival recession also did not differ between test and control groups at the final follow-up in nearly all studies. : Within the limitation of this systemic review and meta-analysis, the obtained data suggest that implants immediately placed into the extraction sockets of teeth exhibiting periapical pathology can be successfully osseointegrated for an extended period.
Topics: Humans; Tooth Socket; Dental Implantation, Endosseous; Dental Implants; Immediate Dental Implant Loading
PubMed: 38929509
DOI: 10.3390/medicina60060893 -
Infectious Disease Reports Mar 2024Despite the expanding use of orthopedic devices and the application of strict pre- and postoperative protocols, the elimination of postoperative implant-related... (Review)
Review
Current Progress and Future Perspectives in Contact and Releasing-Type Antimicrobial Coatings of Orthopaedic Implants: A Systematic Review Analysis Emanated from In Vitro and In Vivo Models.
Despite the expanding use of orthopedic devices and the application of strict pre- and postoperative protocols, the elimination of postoperative implant-related infections remains a challenge. To identify and assess the in vitro and in vivo properties of antimicrobial-, silver- and iodine-based implants, as well as to present novel approaches to surface modifications of orthopedic implants. A systematic computer-based review on the development of these implants, on PubMed and Web of Science databases, was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Overall, 31 in vitro and 40 in vivo entries were evaluated. Regarding the in vitro studies, antimicrobial-based coatings were assessed in 12 entries, silver-based coatings in 10, iodine-based in 1, and novel-applied coating technologies in 8 entries. Regarding the in vivo studies, antimicrobial coatings were evaluated in 23 entries, silver-coated implants in 12, and iodine-coated in 1 entry, respectively. The application of novel coatings was studied in the rest of the cases (4). Antimicrobial efficacy was examined using different bacterial strains, and osseointegration ability and biocompatibility were examined in eukaryotic cells and different animal models, including rats, rabbits, and sheep. Assessment of both in vivo and in vitro studies revealed a wide antimicrobial spectrum of the coated implants, related to reduced bacterial growth, inhibition of biofilm formation, and unaffected or enhanced osseointegration, emphasizing the importance of the application of surface modification techniques as an alternative for the treatment of orthopedic implant infections in the clinical settings.
PubMed: 38667751
DOI: 10.3390/idr16020025