-
Evidence-based Dentistry Sep 2023A systematic appraisal and statistical aggregation of primary studies in humans. (Meta-Analysis)
Meta-Analysis
DESIGN
A systematic appraisal and statistical aggregation of primary studies in humans.
DATA SOURCES
The researchers utilized PubMed (Medline) and Scopus databases as the primary data sources for this study. They performed a comprehensive literature search based on free keywords and Medical Subject Heading (MeSH) terms to enhance the search accuracy. The database search was concluded on November 13, 2022. Furthermore, a meticulous examination of the references cited in the selected studies was conducted to identify additional relevant articles that could be incorporated into the analysis.
STUDY SELECTION
The systematic review focused on partially or fully edentulous patients receiving dental implants and aimed to determine if the lack of keratinized mucosa at the implant site increased the risk of peri-implantitis compared to patients with adequate keratinized mucosa. Human studies with a minimum of 100 implants, cross-sectional, cohort, or case-control designs, and a follow-up period of at least one year were included. Studies lacking a clear case definition or information on peri-implantitis and those that did not investigate keratinized mucosa as a risk indicator were excluded.
DATA EXTRACTION AND SYNTHESIS
Two reviewers independently utilized a systematic review screening website (Rayyan, Qatar Computing Research Institute, Qatar Foundation) to select potential articles, and conflicts were resolved through discussion or consultation with a third reviewer. The data extraction process involved recording information from the included articles, such as study design, patient and implant numbers, prosthesis type (fixed or removable), follow-up duration, peri-implantitis case definition, prevalence at patient and implant levels, keratinized mucosa cutoff value, odds ratio (OR) of peri-implantitis considering keratinized mucosa, and conclusions on the potential effect of keratinized mucosa from each study. The Newcastle Ottawa scale (NOS) and a modified version of NOS were used, respectively, to assess the quality of cohort and cross-sectional studies. Studies scoring below 6 out of 9 points were classified as low quality. For the meta-analysis, the relationship between peri-implantitis and keratinized mucosa was evaluated using the odds ratio (OR) and standard error (SE). Heterogeneity was assessed through the Chi test and I index, determining whether a random-effects or fixed-effects model should be applied. Subgroup and cluster analyses were conducted based on specific criteria, and forest plots and funnel plots were generated to visualize results and identify potential study bias. Sensitivity analysis was performed to verify the robustness of the meta-analysis, with statistical significance set at p < 0.05. The Review Manager (RevMan) software facilitated data analysis. The GRADE rating system was used to determine the level of evidence, considering factors such as bias risk, imprecision, inconsistency, indirectness, and publication bias. The certainty of the evidence was evaluated based on the overall outcomes of analyzed subgroups.
RESULTS
Twenty-two primary studies were identified, and a meta-analysis was conducted on 16 cross-sectional studies. The prevalence of peri-implantitis ranged from 6.68% to 62.3% at the patient level and from 4.5% to 58.1% at the implant level. The overall analysis revealed a significant association between the lack of keratinized mucosa and a higher prevalence of peri-implantitis (OR = 2.78, 95% CI 2.07-3.74, p < 0.00001). Subgroup analyses with a consistent case definition of peri-implantitis (MBL ≥ 2 mm) showed similar results (OR = 1.96, 95% CI 1.41-2.73, p < 0.0001). Studies focusing on fixed prostheses only demonstrated that the lack of keratinized mucosa was associated with an increased prevalence of peri-implantitis (OR = 2.82, 95% CI 1.85-4.28, p < 0.00001). Among patients under regular implant maintenance, the absence of keratinized mucosa significantly raised the occurrence of peri-implantitis (OR = 2.08, 95% CI 1.41-3.08, p = 0.0002). Studies adjusting for other variables also confirmed a higher risk of peri-implantitis with inadequate keratinized mucosa (OR = 3.68, 95% CI 2.32-5.82, p = 0.007). Although some publication bias was observed, the certainty of evidence based on the GRADE system was judged to be "moderate."
CONCLUSIONS
The lack of keratinized mucosa increased the risk of peri-implantitis, emphasizing the need to consider it during dental implant placement. Inadequate data on patient-specific factors and the predominance of cross-sectional studies influenced the evidence quality (i.e., moderate). Future studies with consistent methodologies shall confirm these findings and identify additional risk indicators to improve implant dentistry practices.
Topics: Humans; Peri-Implantitis; Dental Implants; Cross-Sectional Studies; Mucous Membrane; Risk Factors
PubMed: 37537217
DOI: 10.1038/s41432-023-00913-4 -
Clinical Oral Implants Research Sep 2023For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years.
MATERIALS AND METHODS
An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD.
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients).
CONCLUSIONS
After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Topics: Humans; Dental Implants; Prospective Studies; Retrospective Studies; Titanium; Bone Diseases, Metabolic
PubMed: 37750521
DOI: 10.1111/clr.14133 -
Journal of Neuroengineering and... Nov 2023The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced... (Review)
Review
BACKGROUND
The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure.
METHODS
Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices.
RESULTS
50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket.
DISCUSSION
There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.
Topics: Humans; Prosthesis Design; Research Design; Amputation Stumps; Artificial Limbs; Extremities
PubMed: 37926807
DOI: 10.1186/s12984-023-01270-0 -
Clinical Oral Implants Research Sep 2023To compare and report on the performance of implant-supported fixed dental prostheses (iFDPs) fabricated using additive (AM) or subtractive (SM) manufacturing. (Review)
Review
AIM
To compare and report on the performance of implant-supported fixed dental prostheses (iFDPs) fabricated using additive (AM) or subtractive (SM) manufacturing.
METHODS
An electronic search was conducted (Medline, Embase, Cochrane Central, Epistemonikos, clinical trials registries) with a focused PICO question: In partially edentulous patients with missing single (or multiple) teeth undergoing dental implant therapy (P), do AM iFDPs (I) compared to SM iFDPs (C) result in improved clinical performance (O)? Included were studies comparing AM to SM iFDPs (randomized clinical trials, prospective/retrospective clinical studies, case series, in vitro studies).
RESULTS
Of 2'184 citations, no clinical study met the inclusion criteria, whereas six in vitro studies proved to be eligible. Due to the lack of clinical studies and considerable heterogeneity across the studies, no meta-analysis could be performed. AM iFDPs were made of zirconia and polymers. For SM iFDPs, zirconia, lithium disilicate, resin-modified ceramics and different types of polymer-based materials were used. Performance was evaluated by assessing marginal and internal discrepancies and mechanical properties (fracture loads, bending moments). Three of the included studies examined the marginal and internal discrepancies of interim or definitive iFDPs, while four examined mechanical properties. Based on marginal and internal discrepancies as well as the mechanical properties of AM and SM iFDPs, the studies revealed inconclusive results.
CONCLUSION
Despite the development of AM and the comprehensive search, there is very limited data available on the performance of AM iFDPs and their comparison to SM techniques. Therefore, the clinical performance of iFDPs by AM remains to be elucidated.
Topics: Humans; Prospective Studies; Retrospective Studies; Dental Implants; Ceramics; Polymers
PubMed: 37750533
DOI: 10.1111/clr.14085 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Journal of Prosthodontics : Official... Apr 2024This systematic review was conducted to evaluate the prevalence of interproximal contact loss (ICL) between implant restorations and adjacent teeth in relation to age,... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
This systematic review was conducted to evaluate the prevalence of interproximal contact loss (ICL) between implant restorations and adjacent teeth in relation to age, gender, follow-up time, and arch location.
METHODS
This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, outcome (PICO) question was "What is the prevalence of the ICL between implant restoration and adjacent teeth?" The search strategy used four main electronic databases and an additional manual search was performed until February 2023. Clinical studies that evaluated the prevalence of interproximal open contact between implant restorations and adjacent teeth were included. A qualitative analysis for clinical studies was used to assess the risk of bias. In addition, a single-arm meta-analysis of proportion was performed to evaluate the percentage of mesial versus distal open contact and total ICL between implant restoration and adjacent teeth.
RESULTS
Fifteen studies published between 2014 and 2023 met the eligibility criteria. Seven studies presented ICL rates higher than 20%. All studies evaluated ICL in posterior regions (molar, premolar area). Five studies had an ICL rate lower than 50% and three studies had an ICL rate higher than 50%. One study assessed the interproximal contact at three months post-restoration insertion, four studies assessed the interproximal contact at 1-year follow-up and nine studies evaluated the interproximal contact over 2 years of follow-up. Mesial and distal ICL rates were 44.2% (95% CI: 30.6% to 58.6%) and 27.5% (95% CI: 10.5% to 55.0%), respectively. The heterogeneity between studies was high (I (95% CI) = 87.8% (75.9% to 93.8%).
CONCLUSION
Based on the results of the included studies, the prevalence of ICL was high, occurring more frequently at the mesial contact. There were no significant differences in relation to age, gender, and arch location.
Topics: Humans; Dental Implants; Dental Implantation, Endosseous; Tooth; Mouth, Edentulous; Molar
PubMed: 37794763
DOI: 10.1111/jopr.13780 -
The Laryngoscope Apr 2024This review aims to quantify the pooled functional gain (FG) in different types of hearing loss with the transcutaneous hearing device, Osia (Cochlear, Sydney,... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
This review aims to quantify the pooled functional gain (FG) in different types of hearing loss with the transcutaneous hearing device, Osia (Cochlear, Sydney, Australia) in comparison with the unaided state. Secondary outcomes are patient-reported outcomes measures (PROMs) and complication rates.
DATA SOURCES
Medline, Embase, SCOPUS, Cochrane CENTRAL, PROSPERO and Cochrane Library.
REVIEW METHODS
Systematic review and meta-analysis of indexed search terms relating to "Osia," "Osseointegration," "Cochlear Implant," and "Bone-Anchored Prosthesis" was performed from database inception to September 20, 2022.
RESULTS
Of the 168 studies identified, 14 studies with 15 patient cohorts (n = 314) met inclusion criteria for meta-analysis. Pooled overall mean FG for all types of hearing loss was 35.0 dB sound pressure level (SPL) (95% confidence interval [CI] 29.12-40.97) compared against unaided hearing. Pooled FG for conductive/mixed hearing loss was 37.7 dB SPL (95% CI 26.1-49.3). Pooled single-sided deafness (SSD) FG could not be calculated due to the small patient cohort for whom SSD data was reported. There is a trend toward improvements in speech receptiveness threshold, signal to noise ratio, and some PROMs compared with baseline hearing. Early complication rates demonstrate risks similar to other transcutaneous implants, with a low predicted explantation (0.11%, 95% CI 0.00%-1.90%) and wound infection rate (1.92% [95% CI 0.00%-6.17%]). No articles directly comparing transcutaneous devices were identified.
CONCLUSION
The Osia devices demonstrate clear audiologic benefits and a good safety profile for the included patient population. Our study results indicate that frequency-specific gain, PROMs, and the audiological benefit in single-sided deafness may be areas for future prospective research. Laryngoscope, 134:1531-1539, 2024.
Topics: Humans; Bone Conduction; Hearing Aids; Cochlear Implants; Hearing Loss, Conductive; Hearing Loss; Deafness; Speech Perception; Treatment Outcome
PubMed: 37721219
DOI: 10.1002/lary.31053 -
The Journal of Oral Implantology Dec 2023Dental implants are a predictable option to replace missing teeth. Patients on antiresorptive medications used to treat disorders associated with bone resorption may... (Meta-Analysis)
Meta-Analysis
Dental implants are a predictable option to replace missing teeth. Patients on antiresorptive medications used to treat disorders associated with bone resorption may need dental implants to replace missing teeth. The data on implant failure in patients on antiresorptive medication requiring dental implants, is conflicting and limited. This systematic review aims to investigate if antiresorptive medications have any clinical impact on dental implant survival. Electronic databases were searched until May 2020. The focus question (PICOS): Participants: humans, Interventions: implant placement surgery in patients on antiresorptive medication, Comparisons: patients on antiresorptive medication vs control (patients not on antiresorptive medication), Outcomes: implant survival, and Study design: clinical studies. The protocol of this systematic review was registered in PROSPERO (CRD42020209083). Fourteen nonrandomized studies were selected for data extraction and risk of bias assessment using the ROBINS-1 tool. Only studies with a control were included for the meta-analysis, 8 articles were included in the meta-analysis using implant-level data, and 5 articles were included in the meta-analysis using patient-level data. There was no statistical significance between the 2 groups at the patient level based on 265 patients. However, there was a statistically significant difference at the implant level based on 2697 implants. Therefore, antiresorptive medications, mainly bisphosphonates (BPs), may significantly contribute to implant failure. Antiresorptive medications, especially BPs may reduce implant survival and impair the osseointegration of dental implants. Failed implants in patients on BPs may not lead to osteonecrosis and may be replaced with success.
Topics: Humans; Dental Implants; Bone Density Conservation Agents; Diphosphonates; Osteonecrosis; Osseointegration
PubMed: 37905745
DOI: 10.1563/aaid-joi-D-21-00160 -
Nigerian Journal of Clinical Practice Sep 2023Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients.... (Review)
Review
Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients. Recently, immediate loading of implants has gained much importance as it helps hasten the procedure and provides more comfort to patients. A previous systematic review published 5 years ago compared the success rates between immediate and conventional loading. There are several factors that influence the success rate of implants that were not discussed in detail in the previous review. Hence, the present systematic review is done to report differences in the outcomes from single implant restorations of missing teeth in the posterior region in patients who were subjected to immediate loading and conventional loading. A follow up for 1 year was done. Electronic databases of Medline, Scopus, and Web of Science were searched for publications in the English Language during May 2021. The search results yielded 306 articles, out of which 225 were excluded based on title and abstract screening. Screening of the remaining 81 full text articles yielded 14 original research articles that satisfied the predefined inclusion criteria. Meta analysis was not possible due to the heterogeneity of the data. The overall success rate of the immediate loading of a single implant is 94.31%. Implants in the maxillary region had a higher survival rate than those in the mandibular region. The age range between 18 and 80 years showed good prognosis and outcomes in older individuals. Good oral hygiene was emphasized for all patients to prevent any secondary conditions or delays in healing.
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Humans; Middle Aged; Young Adult; Anodontia; Dental Implants; Dental Prosthesis, Implant-Supported; Immediate Dental Implant Loading; Tooth Loss
PubMed: 37794532
DOI: 10.4103/njcp.njcp_884_22 -
Journal of Neurosurgery. Spine Oct 2023By minimizing imaging artifact and particle scatter, carbon fiber-reinforced polyetheretherketone (CF-PEEK) spinal implants are hypothesized to enhance radiotherapy (RT)...
OBJECTIVE
By minimizing imaging artifact and particle scatter, carbon fiber-reinforced polyetheretherketone (CF-PEEK) spinal implants are hypothesized to enhance radiotherapy (RT) planning/dosing and improve oncological outcomes. However, robust clinical studies comparing tumor surgery outcomes between CF-PEEK and traditional metallic implants are lacking. In this paper, the authors performed a systematic review of the literature with the aim to describe clinical outcomes in patients with spine tumors who received CF-PEEK implants, focusing on implant-related complications and oncological outcomes.
METHODS
A systematic review of the literature published between database inception and May 2022 was performed in accordance with the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The PubMed database was queried using the terms "carbon fiber" and "spine" or "spinal." The inclusion criteria were articles that described patients with CF-PEEK pedicle screw fixation and had a minimum of 5 patients. Case reports and phantom studies were excluded.
RESULTS
This review included 11 articles with 326 patients (237 with CF-PEEK-based implants and 89 with titanium-based implants). The mean follow-up period was 13.5 months, and most tumors were metastatic (67.1%). The rates of implant-related complications in the CF-PEEK and titanium groups were 7.8% and 4.7%, respectively. The rate of pedicle screw fracture was 1.7% in the CF-PEEK group and 2.4% in the titanium group. The rates of reoperation were 5.7% (with 60.0% because of implant failure or junctional kyphosis) and 4.8% (all because of implant failure or junctional kyphosis) in the CF-PEEK and titanium groups, respectively. When reported, 72.5% of patients received postoperative RT (41.0% stereotactic body RT, 30.8% fractionated RT, 25.6% proton, 2.6% carbon ion). Four articles suggested that implant artifact was reduced in the CF-PEEK group. Local recurrence occurred in 14.4% of CF-PEEK and 10.7% of titanium-implanted patients.
CONCLUSIONS
While CF-PEEK harbors similar implant failure rates to traditional metallic implants with reduced imaging artifact, it remains unclear whether CF-PEEK implants improve oncological outcomes. This study highlights the need for prospective, direct comparative clinical studies.
Topics: Humans; Carbon Fiber; Titanium; Prospective Studies; Polyethylene Glycols; Ketones; Carbon; Pedicle Screws; Postoperative Complications; Neoplasms; Kyphosis
PubMed: 37382293
DOI: 10.3171/2023.5.SPINE23106