Platelets Dec 2023Arterial tonometry and vascular calcification measures are useful in cardiovascular disease (CVD) risk assessment. Prior studies found associations between tonometry...
Arterial tonometry and vascular calcification measures are useful in cardiovascular disease (CVD) risk assessment. Prior studies found associations between tonometry measures, arterial calcium, and CVD risk. Activated platelets release angiopoietin-1 and other factors, which may connect vascular structure and platelet function. We analyzed arterial tonometry, platelet function, aortic, thoracic and coronary calcium, and thoracic and abdominal aorta diameters measured in the Framingham Heart Study Gen3/NOS/OMNI-2 cohorts ( = 3,429, 53.7% women, mean age 54.4 years ±9.3). Platelet reactivity in whole blood or platelet-rich plasma was assessed using 5 assays and 7 agonists. We analyzed linear mixed effects models with platelet reactivity phenotypes as outcomes, adjusting for CVD risk factors and family structure. Higher arterial calcium trended with higher platelet reactivity, whereas larger aortic diameters trended with lower platelet reactivity. Characteristic impedance (Zc) and central pulse pressure positively trended with various platelet traits, while pulse wave velocity and Zc negatively trended with collagen, ADP, and epinephrine traits. All results did not pass a stringent multiple test correction threshold ( < 2.22e-04). The diameter trends were consistent with lower shear environments invoking less platelet reactivity. The vessel calcium trends were consistent with subclinical atherosclerosis and platelet activation being inter-related.
Topics: Female; Male; Humans; Calcium; Pulse Wave Analysis; Blood Pressure; Platelet Activation; Atherosclerosis
PubMed: 37609998
DOI: 10.1080/09537104.2023.2238835 -
Clinical Oral Investigations Sep 2023To investigate the intraosseous arterial pathways and anastomoses in the alveolar aspects of the maxilla in order to better understand the arterial scattering pattern.
OBJECTIVES
To investigate the intraosseous arterial pathways and anastomoses in the alveolar aspects of the maxilla in order to better understand the arterial scattering pattern.
MATERIALS AND METHODS
Eleven cadavers were selected for macroscopic intraosseous arterial analyses by corrosion casting. The red-colored acrylic resin was injected into the external carotid arteries. The specimens were kept in an enzymatic solution at 36 °C for about 60 days, depending on the process progression. After removal of the soft tissues and drying, the bone was macerated by potassium hydroxide to analyze the course and the mean diameters of the intraosseous anastomoses.
RESULTS
Vertico-oblique and horizontal intraosseous arteries and anastomoses between the greater palatine-, posterior superior alveolar-, and infraorbital arteries were detected. The vertico-oblique anastomoses were found on the anterolateral wall of the maxilla and the alveolar crest with a mean diameter of 0.46 mm; nevertheless, the horizontal (transalveolar) anastomoses were identified in the interdental septum/alveolar crest with the mean diameter of 0.41 mm. From the horizontal anastomoses, small intraseptal branches supplied the territory of the alveolar socket in various directions.
CONCLUSIONS
The localization of intraosseous arterial anastomoses is critical in implant-related surgeries, predominantly to maintain proper circulation.
CLINICAL RELEVANCE
Based on vertico-oblique and transalveolar anastomoses, simultaneous buccal- and palatal flap elevation (particularly on the palatal side) should be avoided to minimize patient morbidity and intra- or postoperative complications. Moreover, preserving transverse loops in the interdental septum is essential during implant surgeries, which can significantly influence collateral periosteal and osteal circulation to prevent ischemia.
Topics: Humans; Maxilla; Dental Implants; Arteries; Cadaver
PubMed: 37460902
DOI: 10.1007/s00784-023-05141-9 -
Open Heart Sep 2023Inferior vena cava (IVC) diameter may be a surrogate for volume status in acute decompensated heart failure (ADHF). The utility of IVC diameter measurement is under...
OBJECTIVES
Inferior vena cava (IVC) diameter may be a surrogate for volume status in acute decompensated heart failure (ADHF). The utility of IVC diameter measurement is under studied. The aim of this study was to assess the relationship between IVC diameter, clinical variables and ADHF rehospitalisations.
METHODS
Retrospective chart review of 200 patients admitted for ADHF from 2018 to 2019 with transthoracic echocardiogram during index hospitalisation. Charts were assessed for ADHF rehospitalisation within 1 year.
RESULTS
The median age was 64, 30.5% were female, and average left ventricular ejection fraction was 41%±20%. IVC diameter correlated to pulmonary arterial (PA) pressure (R=0.347, p<0.001) and body surface area (BSA) (R=0.424 p<0.001). IVC diameter corrected for BSA correlated to PA pressure (R=0.287, p<0.001) and log N-terminal B-type natriuretic peptide (NT-proBNP) (R=0.247, p≤0.01). Patients rehospitalised within 1 year had significantly greater mean IVC diameter compared with those not rehospitalised (p<0.001) while there was no difference in mean net weight lost during index hospitalisation or mean log NT-proBNP. Patients with IVC diameter greater than 2.07 cm had significantly increased ADHF rehospitalisation (85.6% vs 49.3%, log rank p<0.001) with HR 2.44 (95% CI 1.85 to 3.23, p<0.001). In multivariable Cox regression only IVC diameter (p<0.001), presence of tricuspid regurgitation (p=0.02) and NYHA class III/IV (p<0.001) independently predicted ADHF rehospitalisation within 1 year.
CONCLUSIONS
IVC diameter is predictive of rehospitalisation in patients with ADHF and may identify patients in need of greater monitoring and diuresis.
Topics: Humans; Female; Male; Patient Readmission; Retrospective Studies; Stroke Volume; Vena Cava, Inferior; Ventricular Function, Left; Heart Failure
PubMed: 37696618
DOI: 10.1136/openhrt-2023-002331 -
The British and Irish Orthoptic Journal 2023Positive fusional vergence (PFV) is vital in maintaining fusion in critical and continuous near tasks such as reading or performing digital screen tasks. This study...
BACKGROUND
Positive fusional vergence (PFV) is vital in maintaining fusion in critical and continuous near tasks such as reading or performing digital screen tasks. This study investigated how PFV changed under various lighting conditions.
METHODS
This cross-sectional study recruited 34 participants aged between 21 and 25 years, with best corrected visual acuity (BCVA) 0.0 logMAR and insignificant refractive error. Three different illuminations-low illumination (50 lux), medium lighting (100 lux), and high illumination (150 lux)-were used to examine the ocular parameters PFV (blur, break, and recovery points), contrast sensitivity and pupil diameter.
RESULTS
Pupil diameter changed significantly in different room illuminations ( = 0.00). There was no significant difference in contrast sensitivity across the three levels of room illumination ( = 0.368). Mean PFV (SD) (blur) was 14.5 (2.5) in 50 lux, 10.2 (2.2) in 100 lux, and 8.2 (2.1) in 150 lux. Under 50, 100 and 150 lux, respectively, the mean PFV (SD) (break) values were 16.7 (2.4), 13.4 (1.8), and 10.8 (2.2), and the mean PFV (SD) (recovery) values were 13.3 (2.1), 10.7 (2.1), and 7.5 (2.7). With increased illumination levels, PFV blur, break, and recovery values were significantly lower ( < 0.001).
CONCLUSIONS
PFV values were significantly higher in lower illumination. Clinicians should be aware that room illumination affected the PFV values measured.
PubMed: 37780187
DOI: 10.22599/bioj.296 -
Clinical Ophthalmology (Auckland, N.Z.) 2023Myopic eyes combining gamma peripapillary atrophy and peripapillary staphyloma were sorted according to the presence of intrachoroidal cavitation (PICCs) or its absence...
PURPOSE
Myopic eyes combining gamma peripapillary atrophy and peripapillary staphyloma were sorted according to the presence of intrachoroidal cavitation (PICCs) or its absence (combinations). Visual field defects (VFDs) and factors discriminating these groups were analyzed.
METHODS
These groups were sorted by optical coherence tomography. VFDs were assessed using the Humphrey Field Analyzer 3, SITA standard. Ovality index (OI) was the ratio between the shortest and longest diameters of the disc. The proportions of PICCs, lamina cribrosa defects (LCDs) and clusters in each Garway-Heath's sector (A-F) were analyzed. All variables were compared between PICCs and combinations. A multivariate logistic regression analysis was performed ultimately.
RESULTS
Of the 93 eyes, we obtained, 20 PICCs and 73 combinations. The prevalence of VFDs and LCDs in PICCs were 65% (13/20) and 30% (6/20), respectively. PICCs 85% (17/20) and LCDs 12% (11/93) predominated in sector B (inferotemporal) and clusters 9.7% (9/93) in the corresponding sector. The proportion of VFDs was significantly higher in PICCs than combinations (). In sector B, the proportion of LCDs was significantly higher in PICCs than combinations (). The mean OI was significantly lower () in PICCs than combinations. Multivariate logistic regression analysis concluded that mean OI () was the only statistically significant factor discriminating PICCs and combinations.
CONCLUSION
Mean OI discriminating PICCs from combinations is further evidence of a gradation of structural changes between them. It could be related to the higher proportion of VFDs in PICCs. The predominant distribution of PICCs infero-temporally supports PICC as a cause of uncertainty in glaucoma diagnosis in high myopia. Furthermore, the highest proportion of PICCs and LCDs in this sector highlights its vulnerability to damage in myopic eyes and deserves further investigation as it is also primarily involved in glaucoma.
PubMed: 37933329
DOI: 10.2147/OPTH.S404167 -
Clinical Ophthalmology (Auckland, N.Z.) 2023To evaluate the resultant thickness of the WaveLight FS200 (Alcon Vision, LLC) created LASIK flap compared to intended thickness at the surgical visit, using the...
PURPOSE
To evaluate the resultant thickness of the WaveLight FS200 (Alcon Vision, LLC) created LASIK flap compared to intended thickness at the surgical visit, using the WaveLight EX500 (Alcon Vision, LLC) pachymeter and the resultant flap diameter compared to intended diameter.
METHODS
This single arm, prospective, single surgeon study assessed the accuracy of the intended flap thickness and diameter, after successful bilateral LASIK surgery. The WaveLight FS200 femtosecond laser was used to create all flaps with an intended thickness of 120 μm. Flap thickness was calculated by subtracting the stromal bed thickness after flap lift from the preoperative corneal thickness using the WaveLight EX500 on-board optical pachymeter. Flap diameter was determined using digital analysis.
RESULTS
A total of 58 subjects (116 eyes) completed the study. The calculated mean flap thickness was 120.6 ± 9.0 μm (range 102 to 143 μm) using the EX500 pre- and post-flap pachymetry measurements. There was no statistically significant difference between the planned and achieved flap thickness (p > 0.05). The mean difference in flap diameter between planned and actual was 0.02 ± 0.05 mm. Corneal thickness measured by Pentacam at up to 2 months preoperatively versus EX500 just prior to surgery was similar, with EX500 measuring 2 μm less on average than the Pentacam.
CONCLUSION
The results suggest that the WaveLight FS200 laser is reliable for LASIK flap thickness and diameter and accurately created flaps at the intended thickness and the intended diameter.
PubMed: 38111853
DOI: 10.2147/OPTH.S431885 -
Cureus Oct 2023Interpretation of imaging modalities depends on robust normal reference limits. Ethnicity is an essential determinant of cardiac chamber sizes. Though few studies from...
BACKGROUND AND AIM
Interpretation of imaging modalities depends on robust normal reference limits. Ethnicity is an essential determinant of cardiac chamber sizes. Though few studies from India have focused on this research, it has yet to include the Kashmiri population. We aimed to study normal echocardiographic values of healthy Kashmiri adults and compare them with Western and Indian studies.
METHODS
It was a prospective observational study on healthy adults of Kashmir Valley. A comprehensive echocardiographic analysis following standardized protocols was performed.
RESULTS
A total of 2245 study participants were analyzed. The mean age was 32.52±11.55 years. There were 1100 (49%) males. Males had higher absolute left ventricular volumes and mass, left atrial volumes, right ventricular diameter, and aortic size, while females had higher absolute left ventricular ejection fraction and early and late diastolic mitral inflow velocities. Males had higher indexed left ventricular end-systolic volume, while females had higher indexed left ventricular end diastole diameter, aorta diameter, right ventricle, and left and right atrial sizes. Left ventricular mass and diastolic parameters were significantly associated with age. Compared with the American Society of Echocardiography/European Association of Cardiovascular Imaging, absolute values of left ventricle size, volumes, mass, right ventricle size, aortic size, and left and right atrial size were higher than those in our study. Our study population had a higher left ventricle ejection fraction. Among indexed parameters, left ventricle volumes, left ventricle systolic diameter, aortic annulus, and left and right atrial volumes were still significantly higher in Western data. While comparing with Indian data, we noted significant regional differences.
CONCLUSION
We provide normal reference values for our local population. We noted significant differences with Western as well as other Indian populations. Our study highlights the need for developing ethnic-specific reference values of various echocardiographic measurements.
PubMed: 38022041
DOI: 10.7759/cureus.47449 -
Journal of Plastic Surgery and Hand... Dec 2023In this report, we describe a super microsurgical technique that enables rapid and accurate anastomosis while adjusting for caliber differences when anastomosing a...
In this report, we describe a super microsurgical technique that enables rapid and accurate anastomosis while adjusting for caliber differences when anastomosing a small-caliber lymphatic vessel and a vein with a larger caliber, which is frequently encountered in surgeries such as lymphaticovenous anastomosis (LVA). The suture size adjustment technique was performed in 30 anastomoses of lymphatic vessels and veins, whose diameter of lymph duct was at least two times smaller than that of the vein. The type of lymphedema, caliber of lymphatic vessels and veins anastomosed, caliber ratio, vein wall thickness, modified caliber ratio after vein wall thickness subtracted, presence of additional anastomosis, and anastomosis time were examined. On average, the lymphatic vessels had a diameter of 0.61 mm, while the veins were 1.43 mm in diameter. The mean caliber ratio of vein to lymphatic vessel was 2.3, while the modified caliber ratio of vein-to-lymphatic vessel was 1.5 on average. The average venous wall thickness was 0.51. The average anastomosis time was 9.1 min and no additional anastomosis due to leakage was necessary in any case. We successfully performed an anastomosis of lymphatic vessels and veins with different calibers, which can maintain long-term patency while adjusting the caliber difference and suppressing leakage at the anastomosis site. Finally, the caliber of the vein is commonly larger than that of the lymphatic vessel to be anastomosed in many cases of LVA surgery, indicating that the proposed anastomosis method could be of therapeutic use in many cases.
Topics: Humans; Veins; Lymphedema; Lymphatic Vessels; Anastomosis, Surgical; Lymphography; Microsurgery
PubMed: 38130209
DOI: 10.2340/jphs.v58.18384 -
Indian Journal of Ophthalmology Aug 2023To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to...
PURPOSE
To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age.
METHODS
Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details.
RESULTS
Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years.
CONCLUSION
Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.
Topics: Child; Humans; Retrospective Studies; Longitudinal Studies; Cornea; Glaucoma; Intraocular Pressure; Trabeculectomy; Biometry; Treatment Outcome; Follow-Up Studies
PubMed: 37530265
DOI: 10.4103/IJO.IJO_122_23 -
Pulmonology Dec 2023Patients with pulmonary arterial hypertension (PAH) require risk assessments for prognosis and appropriate therapy. These assessments need to be improved by... (Observational Study)
Observational Study
BACKGROUND AND OBJECTIVES
Patients with pulmonary arterial hypertension (PAH) require risk assessments for prognosis and appropriate therapy. These assessments need to be improved by incorporating clinical and laboratory data such as the analysis of the right ventricle. We aim to establish echocardiographic morphometric data of the right ventricle and its relationship with the left ventricle, to estimate the hemodynamic severity of precapillary pulmonary hypertension (PHprecapillary).
METHODS
This cohort, prospective, observational, and cross-sectional study included 41 consecutive patients with PHprecapillary using echocardiographic study and cardiac catheterization.
RESULTS
Patients' mean age was 44.0±16.4 years, and 37 were women (90.2%). Idiopathic PAH was diagnosed in 18 patients (43.9%). The World Health Organization/New York Association functional class was III or IV in 31 patients (75.6%). The ratio of the right to left ventricles (RV/LV) echocardiographic diastolic diameters was associated with pulmonary arterial pressures in cardiac catheterization, with the best cutoff per receiver operating characteristic curve being 0.8 for systolic pressure (sensitivity 90.0%, specificity 78.3%, area under the curve [AUC] 0.882) and mean pressure (sensitivity 60.0%, specificity 95.7%, AUC 0.823). Spearman's correlation (R) of RV/LV echocardiographic ratio and the hemodynamic variables was significant for systolic pressure (R = 0.7015, p < 0.0001), mean pressure (R = 0.6332, p < 0.0001), transpulmonary pressure gradient (R = 0.6524, p < 0.0001), pulmonary vascular resistance (R = 0.6076, p = 0.0021), and pulmonary vascular resistance index (R = 0.6229, p = 0.0014).
CONCLUSION
The ratio of RV/LV echocardiographic diastolic diameters contribute to the estimates the hemodynamic severity of precapillary pulmonary hypertension. The best cutoff for this assessment was RV/LV of 0.8.
Topics: Humans; Female; Adult; Middle Aged; Male; Hypertension, Pulmonary; Prospective Studies; Cross-Sectional Studies; Echocardiography; Hemodynamics
PubMed: 34969648
DOI: 10.1016/j.pulmoe.2021.11.007