Journal of Vascular Surgery Jul 2023The aim of this study was to evaluate safety and efficacy of thoracic endovascular aortic repair (TEVAR) for acute Stanford type B aortic dissection (TBAD) with...
OBJECTIVE
The aim of this study was to evaluate safety and efficacy of thoracic endovascular aortic repair (TEVAR) for acute Stanford type B aortic dissection (TBAD) with retrograde type A intramural hematoma (TAIMH).
METHODS
Patients with acute TBAD with retrograde TAIMH treated with TEVAR between January 1, 2014, to March 31, 2022, were retrospectively reviewed. Aortic diameter and distance were measured using the 3D Slicer image computing platform. Patients' characteristics, procedural, in-hospital and follow-up data, and aortic remodeling were analyzed.
RESULTS
Fifty-two patients (average age, 52.6 years; 42 males [80.8%]) were included. The median interval from symptom onset to TEVAR was 11 days (interquartile range, 7.0-16.8 days). The maximal diameter of the ascending aorta (AA) was <50 mm, and the hematoma thickness in the AA was ≤10 mm in all patients. Both the in-hospital and 30-day mortality rates were 0%. The 30-day complication rate was 11.5%. The overall cumulative survival rates were 100% at 1 year, 97.1% at 3 years, and 92.6% at 5 years. Four of 52 patients (7.7%) developed retrograde type A aortic dissection at 10 days to 4 months postoperatively, and one of 52 patients (1.9%) developed an isolated AA dissection 4 months postoperatively; these five patients were treated and alive at late follow-up in March 2022. The rates of cumulative freedom from thoracic aortic re-intervention were 93.7% at 1 year and 90.7% at 5 years. Positive AA remodeling was observed in 92.3% (48/52) of patients during follow-up. The maximal diameter of AA (mean ± standard error of mean) at admission was 42.7 ± 0.8 mm, which decreased to 39.5 ± 0.9 mm at last follow-up. The maximal AA hematoma thickness at admission was 7.6 ± 0.3 mm, which reduced to 2.2 ± 0.9 mm at last follow-up.
CONCLUSIONS
For selected patients of acute Stanford TBAD with retrograde TAIMH, endovascular repair may be a safe, effective, and durable alternative treatment, if the maximum diameter of the AA is <50 mm and the intramural hematoma thickness in the AA is ≤10 mm.
Topics: Male; Humans; Middle Aged; Endovascular Aneurysm Repair; Aortic Aneurysm, Thoracic; Blood Vessel Prosthesis Implantation; Retrospective Studies; Endovascular Procedures; Treatment Outcome; Time Factors; Aortic Dissection; Hematoma
PubMed: 36921645
DOI: 10.1016/j.jvs.2023.02.021 -
Journal of Interventional Cardiac... Jun 2024Amplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial...
BACKGROUND
Amplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial appendage (LAA) landing zone. However, mean, perimeter-, or area-derived diameter might be more accurate measures for device sizing.
METHODS
Retrospective analysis of 150 consecutive patients undergoing LAAO is guided by pre-procedural cardiac CT. A total of 117 patients were included; 7 were excluded due to renal failure and 26 due to closure with the sandwich technique. The maximum, mean, area-, and perimeter-derived diameters of the landing zone were derived from pre-procedural cardiac CT scans, and their accuracy to predict the implanted device size was investigated. The predicted device size was determined based on the currently recommended sizing algorithm. Peri-device leak (PDL) was assessed (grade 1-3) along with the underlying mechanism.
RESULTS
Device-sizing accuracy was superior for mean, area-, and perimeter derived diameters compared with the maximal diameter, especially for eccentric landing zones. Mean difference between predicted and actually implanted device size was 0.08 mm (± 2.77), 0.30 mm (± 2.40), - 0.39 mm (± 2.43), and - 2.55 mm (± 2.57) across mean, area-derived, perimeter-derived, and maximal diameter, respectively. Grade 3 peri-device leak was seen in 8.5% of implants without a significant association to the eccentricity of the landing zone. The leading mechanism for PDL was device malalignment.
CONCLUSION
Our results indicate mean, area-, and perimeter-derived diameters of the device landing zone to perform similar and superior in device-sizing accuracy compared with the maximum diameter.
Topics: Humans; Atrial Appendage; Female; Male; Septal Occluder Device; Retrospective Studies; Aged; Atrial Fibrillation; Tomography, X-Ray Computed; Prosthesis Design; Treatment Outcome; Prosthesis Fitting; Middle Aged
PubMed: 37882993
DOI: 10.1007/s10840-023-01665-y -
Medicine Oct 2023This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This... (Observational Study)
Observational Study
This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 ± 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 ± 0.76 and 8.58 ± 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 ± 0.79 mm and 4.61 ± 0.74 mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (Rs = -0.413, P = .001), positively correlated with "haloes" (Rs = 0.568*, P < .001) and "blurred vision" (Rs = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (Rs = -0.426, P = .001), positively correlated with "haloes" (Rs = 0.624*, P < .001), "starburst" (Rs = 0.233, P = .046) and "difficulty focusing" (Rs = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.
Topics: Humans; Pupil; Lens Implantation, Intraocular; Retrospective Studies; Myopia; Phakic Intraocular Lenses
PubMed: 37800803
DOI: 10.1097/MD.0000000000035198 -
Ultrasound-guided initial diagnosis and follow-up of pediatric idiopathic intracranial hypertension.Pediatric Radiology May 2024Idiopathic intracranial hypertension in children often presents with non-specific symptoms found in conditions such as hydrocephalus. For definite diagnosis, invasive...
BACKGROUND
Idiopathic intracranial hypertension in children often presents with non-specific symptoms found in conditions such as hydrocephalus. For definite diagnosis, invasive intracranial pressure measurement is usually required. Ultrasound (US) of the optic nerve sheath diameter provides a non-invasive method to assess intracranial pressure. Transtemporal US allows imaging of the third ventricle and thus assessment for hydrocephalus.
OBJECTIVE
To investigate whether the combination of US optic nerve sheath and third ventricle diameter can be used as a screening tool in pediatric idiopathic intracranial hypertension to indicate elevated intracranial pressure and exclude hydrocephalus as an underlying pathology. Further, to analyze whether both parameters can be used to monitor treatment outcome.
MATERIALS AND METHODS
We prospectively included 36 children with idiopathic intracranial hypertension and 32 controls. Using a 12-Mhz linear transducer and a 1-4-Mhz phased-array transducer, respectively, optic nerve sheath and third ventricle diameters were determined initially and during the course of treatment.
RESULTS
In patients, the mean optic nerve sheath diameter was significantly larger (6.45±0.65 mm, controls: 4.96±0.32 mm) and the mean third ventricle diameter (1.69±0.65 mm, controls: 2.99±1.31 mm) was significantly smaller compared to the control group, P<0.001. Optimal cut-off values were 5.55 mm for the optic nerve sheath and 1.83 mm for the third ventricle diameter.
CONCLUSIONS
The combined use of US optic nerve sheath and third ventricle diameter is an ideal non-invasive screening tool in pediatric idiopathic intracranial hypertension to indicate elevated intracranial pressure while ruling out hydrocephalus. Treatment can effectively be monitored by repeated US, which also reliably indicates relapse.
Topics: Humans; Female; Male; Child; Pseudotumor Cerebri; Optic Nerve; Adolescent; Child, Preschool; Reproducibility of Results; Sensitivity and Specificity; Follow-Up Studies; Third Ventricle; Prospective Studies; Ultrasonography, Interventional; Infant
PubMed: 38506946
DOI: 10.1007/s00247-024-05905-9 -
Frontiers in Pediatrics 2023To introduce a new technique of single-port-plus-one robotic laparoscopic-modified Lich-Gregoir direct nipple ureteral extravesical reimplantation and ascertain its...
Single-port-plus-one robot-assisted laparoscopic modified Lich-Gregoir direct nipple ureteral extravesical reimplantation in children with a primary obstructive megaureter.
PURPOSE
To introduce a new technique of single-port-plus-one robotic laparoscopic-modified Lich-Gregoir direct nipple ureteral extravesical reimplantation and ascertain its validity in the treatment of pediatric primary obstructive megaureter.
METHODS
Between January 2021 and November 2021, we retrospectively analyzed the clinical data of 12 children with primary obstructive megaureter who were admitted to the Department of Pediatric Surgery of Fujian Provincial Hospital. All 12 children were treated with single-port-plus-one robotic laparoscopic Lich-Gregoir direct nipple ureteral extravesical reimplantation. Five of them were female and seven were male, including nine cases were simple obstructive type, while the remaining three cases were obstructive with reflux type. The mean age of the children was 17.33 ± 6.99 (10-36) months and the mean follow-up time was 14.16 ± 1.75 (12-17) months. Changes in preoperative and first-year postoperative parameters were compared
RESULTS
The mean operative time for all 12 children was 123.58 ± 10.85 (110-145) min, with a mean internal operative time of 101.42 ± 0.85 (90-120) min, a mean operative bleeding time of 2.42 ± 0.67 (2-4) ml, and a mean hematuria duration of 16.08 ± 1.44 (14-19) h. The mean indwelling catheterization time was 2.25 ± 0.45 (2-3) days and the mean hospitalization time was 3.83 ± 0.39 (3-4) days. At the postoperative first year, the ureteral diameter, calyceal diameter, and anterior-posterior renal pelvic diameter were found to be significantly smaller than at the preoperative period (18.83 ± 3.21 mm vs. 6.83 ± 1.27 mm, 13.99 ± 3.58 mm vs. 3.5 ± 2.90 mm, and 34.92 ± 4.25 mm vs. 10.08 ± 1.88 mm, < 0.001). There was a significant increase in renal cortical thickness and the percentage of differential renal function (3.63 ± 1.66 mm vs. 5.67 ± 1.88 mm, 33.75 ± 2.77 mm vs. 37.50 ± 1.31 mm, < 0.001). The resolution rate of obstruction was 100% and no child developed DeNovo vesicoureteral reflux.
CONCLUSION
The technique of modified Lich-Gregoir direct nipple ureteral extravesical reimplantation can help maintain the physiological direction of the ureter and at the same time enhance the effectiveness of antirefluxing in robotic surgery. The design of a single-port-plus-one wound can produce a cosmetic appearance by concentrating and hiding the wound around the umbilicus. This modified reimplantation procedure has the potential to become a promising technique in the robot-assisted treatment of primary obstructive megaureter.
PubMed: 38027297
DOI: 10.3389/fped.2023.1238918 -
Acta Bio-medica : Atenei Parmensis Oct 2023Atypical Lipomatous Tumors (ALTs) are low-grade locally aggressive soft tissue tumors. Deep large sized ALTs of the thigh can cause significant functional impairment due...
BACKGROUND AND AIM
Atypical Lipomatous Tumors (ALTs) are low-grade locally aggressive soft tissue tumors. Deep large sized ALTs of the thigh can cause significant functional impairment due to their mass effect. Surgical resection, which is the treatment of choice for these lesions, can be a though procedure, especially if the neoplasm comes in proximity with noble structures such as large sized arteries or nerves. The aim of our study is to assess risks and effectiveness of surgical resection, evaluating complications, local recurrences and post-operative functionality.
METHODS
We evaluated all the giant ALT (larger diameter of 10 cm or more) of the thigh that received surgery in our institution between 2017 and 2022. Each patient's personal data and tumor size were evaluated. The quality of surgical margins was analyzed. MRI scans were performed both pre-operatively and during patients' follow-up. Lower limb's functional status was assessed using the MSTS score before and after surgery. Intra-operative and post-operative complications were recorded, as well as local recurrences.
RESULTS
Twentythree cases were included in our study. Tumors' mean major diameter was 19.1cm. The mean pre-operative MSTS score was 25.9. Only one case suffered from significant post-operative complications. Only 2 of our cases (8.7%) developed a local recurrence after surgery. The mean post-operative MSTS score was 29.1 Conclusions: A careful surgical resection can be effective in treating giant ALTs of the thigh in reason of good functional outcomes, low complications risks and reasonable local recurrence rates.
Topics: Humans; Thigh; Retrospective Studies; Liposarcoma; Lower Extremity; Soft Tissue Neoplasms; Postoperative Complications; Treatment Outcome
PubMed: 37850775
DOI: 10.23750/abm.v94i5.14275 -
Turkish Journal of Ophthalmology Aug 2023To investigate the effects of pupil diameter on the evaluation of lens and corneal densitometry measured by Scheimpflug tomography.
OBJECTIVES
To investigate the effects of pupil diameter on the evaluation of lens and corneal densitometry measured by Scheimpflug tomography.
MATERIALS AND METHODS
This cross-sectional and comparative study used the right eyes of 32 participants. Corneal and lenticular optical densitometries, corneal volume, anterior segment volume, and anterior chamber depth measurements were taken with the Scheimpflug imaging system when the pupils were mid-dilated and fully dilated. The results were statistically compared.
RESULTS
The mean lens density was 19.20±3.05 when the pupils were mid-dilated (mean pupil diameter 2.98±0.89 mm) and 23.25±3.88 at full dilation (mean pupil diameter 5.01±0.92 mm) (p<0.001). The mean corneal density was 16.15±0.99 with mid-dilated pupils and 16.38±0.95 with fully dilated pupils (p=0.065). Anterior chamber depth and anterior segment volume measurements increased with larger pupil diameter (p<0.05).
CONCLUSION
The lens densitometry values increased with an increase in pupil diameter. The corneal density measurements increased minimally but the differences were not statistically significant. This study revealed that lens densitometry was significantly affected by pupil diameter.
Topics: Humans; Cross-Sectional Studies; Cornea; Pupil; Densitometry
PubMed: 37602578
DOI: 10.4274/tjo.galenos.2022.42724 -
Scientific Reports Dec 2023Previous studies have demonstrated prolonged occlusion flow-mediated dilatation (PO-FMD) could reduce cannulation failure rates and decrease radial artery pulsation loss... (Observational Study)
Observational Study
Previous studies have demonstrated prolonged occlusion flow-mediated dilatation (PO-FMD) could reduce cannulation failure rates and decrease radial artery pulsation loss during trans-radial coronary angiography. However, the time and degree of radial artery dilatation induced after PO-FMD were unclear. This study aimed to evaluate the degree and duration of the radial artery dilation after PO-FMD, and the time point at which the radial artery diameter is expanded to the maximum. This was a prospective observational study. According to the Chinese guideline on the primary prevention of cardiovascular diseases, 142 patients awaking from general anesthesia were divided into two groups: low-risk (LR) group and high-risk (HR) group. Firstly, the baseline radial artery diameter was measured on the left wrist using ultrasound in both groups. Subsequently, the radial artery diameters were obtained continuously at the same location for 5 min after PO-FMD. The baseline radial artery diameter, the maximum radial artery diameter, and the duration of radial artery dilation in the two groups were recorded. The time point at which the radial artery diameter is expanded to the maximum in the LR group and HR group was 26.49 ± 11.69 s and 46.27 ± 12.03 s, respectively (P < 0.01). The time of radial artery dilation and the percentage changes in arterial diameter in HR group were significantly lower than LR group (duration time: mean [mean ± standard]: 136.65 ± 31.55 s vs. 168.98 ± 33.27 s; percentage changes: median [interquartile range] 10.5 [8.6, 12.9] % vs. 15.2 [12.4, 19.0] %). In this study, the optimal puncture time point of PO-FMD in the LR group was 26 s, and in the HR group was 46 s. It would be helpful to guide the time point in radial artery catheterization after PO-FMD.Chinese Clinical Trial Registry identifier: ChiCTR2200066214.
Topics: Humans; Catheterization; Coronary Angiography; Dilatation; Punctures; Radial Artery; Prospective Studies
PubMed: 38066251
DOI: 10.1038/s41598-023-49122-0 -
Cureus Oct 2023Background The present study aims to evaluate the response of locally advanced breast carcinoma (LABC) to neoadjuvant chemotherapy (NACT) using image-guided clip...
Background The present study aims to evaluate the response of locally advanced breast carcinoma (LABC) to neoadjuvant chemotherapy (NACT) using image-guided clip placement based on Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 criteria. Methods Thirty-four patients with LABC were included in the study. Consent for three-dimensional titanium clip placement (400/300/200 mm Liga clips) under local anesthesia with USG guidance was obtained. Serial sonographic/X-ray evaluations of tumor bed size were conducted before every cycle of NACT. All data were recorded in millimeters of concentric tumor regression/non-regression. Tumor regression in a concentric or Swiss cheese pattern and non-responders were evaluated. Assessment of the response to NACT was performed using RECIST criteria, dividing it into four categories. Tumor response was confirmed with computerized tomography (CT) conducted before and after the completion of NACT. Patients underwent surgical management, mostly modified radical mastectomy (MRM), as they had locally advanced breast carcinoma. Following MRM, the clips in the specimen guided the original site of the tumor for histopathological evaluation and response to chemotherapy. Results Tumor response was classified into four types: complete response (CR), partial response (PR), progressive disease (PD), and stable disease. RECIST 1.1 criteria were elaborated and defined. Data for all patients were entered into an Excel sheet (Microsoft Corporation, Redmond, Washington) to prepare a master chart, and the following observations were made and analyzed using SPSS software. The duration of chemotherapy for the study population ranged from 32 to 206 days, with a mean (±SD) of 111.82 (± 52.64) days and a median (IQR) of 81 (63, 158) days. The mean period between clip insertion and completion of NACT was 111.82 days. The baseline sum diameters and post-NACT diameters of the tumors were 70.50 (±13.60) mm before NACT and 17.75 (±17.20) mm after NACT. Hence, the mean size of the lump was statistically significantly lower after NACT, with a mean difference of 52.75 (p<0.05). The mean rate of reduction in tumor diameter was found to be 74.32% (±23.44%) based on RECIST 1.1 criteria. Pathological response was observed in all patients except for 8.8% of the patients. Clinical complete response was seen in 35.29% of patients, and partial response was observed in 52.92% of the patients based on RECIST 1.1 criteria. The study thus demonstrates the effectiveness of NACT in LABC, with a mean reduction in tumor diameter of 74.32%, assessed with the help of RECIST 1.1 criteria. Conclusion NACT for patients with LABC has shown a significant reduction in tumor size. NACT should be the initial mode of management for patients with LABC. RECIST 1.1 criteria are effective and can be used to assess tumor response to NACT. This has aided in the stratification of the response of NACT for further management through systemic therapy (adjuvant chemotherapy) after the surgical excision of the tumor.
PubMed: 38021852
DOI: 10.7759/cureus.47763 -
Life (Basel, Switzerland) Feb 2024(1) Background: Despite advancements in medical research and discoveries, heart failure (HF) still represents a significant and prevalent public health challenge. It is...
(1) Background: Despite advancements in medical research and discoveries, heart failure (HF) still represents a significant and prevalent public health challenge. It is characterized by persistently high mortality and morbidity rates, along with increased rates of readmissions, particularly among the elderly population. (2) Methods: This study was conducted retrospectively on 260 patients with stable or decompensated chronic HF. The parameter of interest in the study population was the mean platelet volume (MPV), and the main objective of the research was to identify a possible relationship between MPV and several variables-biological (NT-proBNP, presepsin, red cell distribution width (RDW)), electrocardiographic (atrial fibrillation (AFib) rhythm, sinus rhythm (SR)), and echocardiographic (left ventricle ejection fraction (LVEF), left atrial (LA) diameter, left ventricle (LV) diameter, pulmonary hypertension (PH)). (3) Results: By applying logistic and linear regression models, we assessed whether there is a correlation between MPV and biological, electrocardiographic, and echocardiographic variables in patients with HF. The results revealed linear relationships between MPV and NT pro-BNP values and between MPV and RDW values, and an increased probability for the patients to have an AFib rhythm, reduced LVEF, dilated LA, dilated LV, and PH as their MPV value increases. The results were deemed statistically relevant based on a -value below 0.05. (4) Conclusions: Through regression model analyses, our research revealed that certain negative variables in HF patients such as increased levels of NT-proBNP, increased levels of RDW, AFib rhythm, reduced LVEF, dilated LA, dilated LV, and PH, could be predicted based on MPV values.
PubMed: 38398768
DOI: 10.3390/life14020260