The Journal of Evidence-based Dental... Dec 2021Objectives The aim of this systematic review was to provide an overview of the scientific evidence available from prospective clinical studies regarding denture hygiene... (Review)
Review
Objectives The aim of this systematic review was to provide an overview of the scientific evidence available from prospective clinical studies regarding denture hygiene interventions. Therefore, investigations addressing the efficacy of removing microorganisms and biofilms formed on the surface of removable dental prostheses (RDPs) and denture base materials in situ and their impact on the properties of denture base materials, such as color stability, surface roughness, and dimensional stability, were included. Methods A systematic literature search was conducted from June 1975-May 2020 and included articles published in English that have been indexed in the digital archives of PubMed and Cochrane (including PubMed, Embase, ICTRP, CT.gov). A complementary manual search of the initially retrieved studies was conducted. Inclusion criteria comprised prospective clinical trials with a minimum of ten participants investigating (1) approaches and methods to remove biofilms formed on the surface of RDPs and denture base materials in situ and/or (2) the influence of these biofilms on denture base materials. A total of forty-four studies were included in this systematic review, which was registered in the PROSPERO database (CRD42020189649). Results and Conclusions Data gathered from the systematic review indicate that the combined use of chemical and mechanical denture hygiene interventions is significantly more effective than single cleaning approaches. Only limited evidence is available from clinical studies regarding the effect of denture hygiene interventions on the properties of denture base materials.
Topics: Denture, Partial, Removable; Humans; Prospective Studies
PubMed: 34922732
DOI: 10.1016/j.jebdp.2021.101644 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
The Journal of Prosthetic Dentistry Feb 2021Reports on digital complete dentures (CDs) are increasing. However, systematic reviews on their accuracy and influencing factors are lacking. (Review)
Review
STATEMENT OF PROBLEM
Reports on digital complete dentures (CDs) are increasing. However, systematic reviews on their accuracy and influencing factors are lacking.
PURPOSE
The purpose of this systematic review was to evaluate the accuracy of digital CDs and to summarize influencing factors.
MATERIAL AND METHODS
An electronic search of the English language literature from January 2009 to October 2019 was performed in the database PubMed/MEDLINE, with the results enriched by manual searches and citation mining. Factors investigated in the selected articles included the fabrication technique, type of computer-aided design and computer-aided manufacturing (CAD-CAM) system, shape of reference model, long-term service, analytical method, and statistical indicators.
RESULTS
A total of 522 articles were identified, of which 14 in vitro articles met the inclusion criteria. Eight articles compared the adaptation of the denture base between digital and conventional methods, 4 studies evaluated the occlusal discrepancies, 4 compared the trueness or adaptation of the denture fabricated with CAD-CAM milling and 3D printing, 1 compared the denture adaptation with 4 different CAD-CAM systems, and 2 evaluated the adaptation of the denture base before and after incubation in artificial saliva.
CONCLUSIONS
Most of the studies reported clinically acceptable values for the occlusal trueness and adaptation of digital CDs. The digital CDs showed similar or better adaptation than conventionally fabricated CDs, and the greatest misfit of the intaglio surface was reported in the posterior palatal seal area and border seal area. The fabrication technique, CAD-CAM system, and long-term service were statistically significant in relation to denture accuracy. Clarification is needed concerning the accuracy of digital CDs according to the shape of the cast, the parameters related to the CAD-CAM process, the analytical method, and the statistical indicators. No clear conclusions can be drawn about the superiority of CAD-CAM milling and 3D printing regarding denture accuracy.
Topics: Computer-Aided Design; Denture Design; Denture, Complete; Printing, Three-Dimensional; Research Design
PubMed: 32115218
DOI: 10.1016/j.prosdent.2020.01.004 -
International Journal of Environmental... Oct 2019The oral health of an ageing population, especially that of the institutionalized elderly population, constitutes a significant concern because it is closely linked to...
The oral health of an ageing population, especially that of the institutionalized elderly population, constitutes a significant concern because it is closely linked to general health and the quality of life. Shared common risk factors drive the development and worsening of poor oral health and non-communicable diseases, which eventually lead to self-care inability. Several studies have reported on the poor oral health of the institutionalized elderly population. However, few comprehensive reports exist regarding the relationship between poor oral health, the oral health-related quality of life (OHRQoL) and the associated factors in this specific population. The objective is to describe recently reported oral health levels, the OHRQoL and the associated factors among older institutional residents. Studies published between July 2009 and June 2019 in MEDLINE, EMBASE and CINAHL were searched. The population, intervention, comparison and outcome (PICO) strategy was used as a guide. The reported factors related to poor oral health were identified (i.e., age, gender, educational level, acquired systemic conditions or dementia/cognitive impairment). Twenty-five surveys (or study series) from 19 countries were included. The level of evidence reported by these studies was generally moderate to strong. The reported oral cleanliness and health of the surveyed institutionalized elderly were poor (>50% of residents had calculus; denture hygiene index > 80%). Gum (approximately 30% of dentate residents had moderate to severe periodontitis), teeth (decayed, missing or filled teeth >20), mucosa (>10% had mucosal lesions) and denture problems (up to 40%) were prevalent and were associated with a poor OHRQoL, especially in females, socially deprived residents or those with mild or above cognitive impairment. Those with a poor OHRQoL might show signs of poor nutrition. This report reviewed evidence-based knowledge on oral health, the OHRQoL and the associated factors among elderly institutional residents. Further research is needed to confirm these observations. For improved oral health, a better OHRQoL and the general well-being of older residents, clinical trials are needed, targeting modifiable factors, such as social inequality, oral healthcare accessibility, and/or nursing home service quality. The relationship between oral health, the OHRQoL and nutrition in this at-risk population also warrants exploration.
Topics: Aged; Homes for the Aged; Humans; Nursing Homes; Oral Health; Quality of Life
PubMed: 31717812
DOI: 10.3390/ijerph16214132 -
Journal of Dentistry Oct 2021This review compared Computer-aided designand Computer-aided manufactured (CAD-CAM) and conventionally constructed removable complete dentures (CDs). (Meta-Analysis)
Meta-Analysis Review
CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes.
OBJECTIVES
This review compared Computer-aided designand Computer-aided manufactured (CAD-CAM) and conventionally constructed removable complete dentures (CDs).
DATA
Seventy-three studies reporting on CAD-CAM (milled/3D-printed) CDs were included in this review. The most recent literature search was performed on 15/03/2021.
SOURCES
Two investigators searched electronic databases [PubMed (MEDLINE), Embase, CENTRAL], online search engines (Google) and research portals. Hand searches were performed to identify literature not available online.
STUDY SELECTION
Studies on CAD-CAM CDs were included if they reported on trueness of fit, biocompatibility, mechanical, surface, chemical, color , microbiological properties, time-cost analysis, and clinical outcomes. Inter-investigator reliability was assessed using kappa scores. Meta-analyses were performed on the extracted data .
RESULTS
The kappa score ranged between 0.897-1.000. Meta-analyses revealed that 3D-printed CDs were more true than conventional CDs (p = 0.039). Milled CDs had a higher flexural-strength than conventional and 3D-printed CDs (p < 0.0001). Milled CDs had a higher flexural-modulus than 3D-printed CDs (p < 0.0001). Milled CDs had a higher yield-strength than injection-molded (p = 0.004), and 3D-printed CDs (p = 0.001). Milled CDs had superior toughness (p < 0.0001) and surface roughness characteristics (p < 0.0001) than other CDs . Rapidly-prototyped CDs displayed poor color-stability compared to other CDs (p = 0.029). CAD-CAM CDs d displayed better retention than conventional CDs (p = 0.015). Conventional CDs had a higher strain at yield point than milled CDs (p < 0.0001), and had superior esthetics than 3D-printed (p < 0.0001). Fabrication of CAD-CAM CDs required less chairside time (p = 0.037) and lower overall costs (p < 0.0001) than conventional CDs.
CONCLUSIONS
This systematic review concludes that CAD-CAM CDs offer a number of improved mechanical/surface properties and are not inferior when compared to conventional CDs.
CLINICAL SIGNIFICANCE
CAD-CAM CDs should be considered for completely edentulous patients whenever possible, since this technique offers numerous advantages including better retention, mechanical and surface properties but most importantly preserves a digital record. This can be a great advantage for older adults with limited access to dental care.
Topics: Aged; Computer-Aided Design; Costs and Cost Analysis; Denture, Complete; Esthetics, Dental; Humans; Patient Reported Outcome Measures; Reproducibility of Results; Surface Properties
PubMed: 34400250
DOI: 10.1016/j.jdent.2021.103777 -
Journal of Indian Prosthodontic Society 2021This systematic review aimed to compare different attachment systems used in mandibular implant supported overdentures by assessing outcomes such as prosthodontic... (Meta-Analysis)
Meta-Analysis Review
AIM
This systematic review aimed to compare different attachment systems used in mandibular implant supported overdentures by assessing outcomes such as prosthodontic maintenance and complication, peri implant tissue changes, retention, and patient satisfaction for optimum selection of attachment system.
SETTINGS AND DESIGN
This systematic review conducted following Preferred Reporting Items for the Systematic Review and Meta Analysis (PRISMA) guidelines.
MATERIALS AND METHODS
A systematic electronic literature search was conducted through PubMed, The Cochrane Central Register of Controlled Trials (Central), and Science direct. A hand search was also performed for individual journals and reference lists of selected studies. Randomized controlled clinical trials and crossover clinical trials from 2010 to 2020 with follow up of more than 1 year were included. The Cochrane Collaboration's tool was used for assessing the risk of bias of included studies.
STATISTICAL ANALYSIS USED
The statistical meta analysis was performed using Review Manager (RevMan) [computer program]. Version 5.4. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboation, 2020.
RESULTS
Six studies that met the inclusion criteria possess the low risk of bias with follow up of more than 1 year were included in this systematic review. Out of four outcomes, meta analysis was performed for prosthodontic maintenance and peri implant tissue changes. Due to the limited availability of data, retention and patient satisfaction were reviewed systematically without meta analysis. The result of meta analysis for ball versus magnet attachment showed statistically significant differences in prosthodontic complications and maintenance, and ball attachment reported fewer complications than the locator attachment (risk ratio [RR] =0.55, confidence interval [CI] =95%, P = 0.03). Peri implant tissue changes were analyzed in the included studies as probing depth and marginal bone loss. The result of meta analysis for probing depth showed no statistically significant difference between bar versus telescopic type of attachment (RR = 0.20, CI = 95%, P = 0.74). The meta analysis results for marginal bone loss showed no statistically significant difference between bar versus telescopic type of attachment (mean difference = 0.35, CI = 95%, P = 0.10).
CONCLUSION
It can be concluded from the current review that bar attachment provided the most superior retention. The telescopic attachment system not only showed the most favorable patient's satisfaction but also reported the least peri implant mucosal changes. The ball attachment system is a favorable choice for limited inter arch space and parallel implant placement.
Topics: Cross-Over Studies; Denture, Overlay; Humans; Jaw, Edentulous; Mandible; Patient Satisfaction
PubMed: 34810359
DOI: 10.4103/jips.jips_158_21 -
Archives of Oral Biology Jul 2023in patients with Parkinson's Disease (PD), oral health can be affected by motor and non-motor symptoms and/or medication use. Therefore, the aim was to systematically... (Review)
Review
OBJECTIVE
in patients with Parkinson's Disease (PD), oral health can be affected by motor and non-motor symptoms and/or medication use. Therefore, the aim was to systematically review the literature on oral health and associated factors of oral health in PD patients.
DESIGN
a literature search was performed from inception up to April 5th, 2023. Original studies that assessed oral health-related factors in PD patients and were written in English or Dutch, were included.
RESULTS
11276 articles were identified, of which 43 met the inclusion criteria (quality range poor-good). A higher prevalence of dental biofilm, bleeding/gingivitis, pocket depth (≥4 mm), tooth mobility, caries, and number of decayed missing filled teeth/surfaces was found in PD patients than in controls. However, no difference between both groups was found when analysing edentulism and wearing dentures. Poor oral health of PD patients was associated with a longer disease duration, higher disease severity, and more prescribed medications.
CONCLUSIONS
oral health of PD patients is worse than that of healthy individuals. It is associated with the duration and severity of PD and medication use. Therefore, we advise regular appointments with oral health care professionals, with an important focus on prevention.
Topics: Humans; Oral Health; Dental Caries; Parkinson Disease; Gingivitis; Tooth Loss
PubMed: 37120970
DOI: 10.1016/j.archoralbio.2023.105712 -
Gerodontology Sep 2019To systematically review longitudinal studies on the association between oral health and frailty indicated by any validated scale or index. (Review)
Review
OBJECTIVE
To systematically review longitudinal studies on the association between oral health and frailty indicated by any validated scale or index.
BACKGROUND
Frailty and poor oral health are common among ageing populations; however, evidence from longitudinal studies is scarce.
METHODS
Three databases (MEDLINE, EMBASE and LILACS) were searched for published literature up to July 2018 using prespecified search strategy. Grey literature was searched using OpenGrey and Google Scholar. Quality of included studies was checked using the Newcastle-Ottawa Quality Assessment Scale (NOS) for longitudinal studies.
RESULTS
Five longitudinal studies from three countries (Mexico, Japan, and UK) that examined the association between oral health and frailty were identified. All studies used Fried's frailty phenotype criteria for measuring frailty. Oral health indicators were number of teeth, periodontal disease, oral functions (functional dentition with occluding pairs and maximum bite force), use of removable dentures, accumulation of oral health problems and dry mouth symptoms. The studies showed significant association of number of teeth (two studies), oral functions (two studies), accumulation of oral health problems and number of dry mouth symptoms with frailty incidence, whereas periodontal disease showed inconsistent associations.
CONCLUSION
This systematic review identified significant longitudinal associations between oral health indicators and frailty that highlight the importance of oral health as a predictor of frailty in older age. There is a need for further research exploring the role of nutrition as a mediator of the relationship between oral health and frailty.
Topics: Aged; Frail Elderly; Frailty; Humans; Japan; Longitudinal Studies; Oral Health
PubMed: 31025772
DOI: 10.1111/ger.12406 -
Journal of Prosthodontics : Official... Apr 2023The strength of 3D-printed resins is affected by different factors, but review articles clarifying these factors are limited. This review lists the factors affecting the... (Review)
Review
PURPOSE
The strength of 3D-printed resins is affected by different factors, but review articles clarifying these factors are limited. This review lists the factors affecting the strength of 3D-printed resins and the possible correlations between them to answer the study question: What are the factors affecting the flexural strength of 3D-printed resins?
METHODS
A database search (PubMed, Google Scholar, and Scopus) was performed, limited to English-language publications between 2010 and February 1, 2022. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used for study selection. The modified Consolidated Standards of Reporting Trials (CONSORT) checklist was used to determine the risk of bias of the included studies in this review. The data analysis was descriptive due to the presence of many variables in the included studies.
RESULTS
Out of 123 studies, 26 were reviewed for full-text analysis, and 19 met the inclusion criteria and were thus included in this systematic review. The included studies were divided according to the investigated resin: 5 studies tested provisional restorations, seven tested denture base resins, 2 tested occlusal devices, 3 tested orthodontic appliances, 1 tested denture teeth, and 1 tested surgical guide resins. These studies investigated the flexural strength of 3D-printed resins, with different factors, such as reinforcement with fillers or nanofillers; printing orientation, angulation, and directions; post-polymerization time and temperature; third-party printing (switching between printers and materials); printing layer thickness; and post-printing rinsing time. Most factors significantly affected the flexural strength of 3D-printed resin.
CONCLUSIONS
The strength of 3D-printed resins could be improved with one or more of the following factors: filler or nanofiller addition; printing orientation, angulation, or directions; printing layer thickness; and post-polymerization time and temperature. However, further studies combining these factors are recommended.
Topics: Flexural Strength; Materials Testing; Printing, Three-Dimensional; Surface Properties; Temperature
PubMed: 36629333
DOI: 10.1111/jopr.13640 -
The Journal of Prosthetic Dentistry Feb 2023Artificial intelligence applications are increasing in prosthodontics. Still, the current development and performance of artificial intelligence in prosthodontic... (Review)
Review
STATEMENT OF PROBLEM
Artificial intelligence applications are increasing in prosthodontics. Still, the current development and performance of artificial intelligence in prosthodontic applications has not yet been systematically documented and analyzed.
PURPOSE
The purpose of this systematic review was to assess the performance of the artificial intelligence models in prosthodontics for tooth shade selection, automation of restoration design, mapping the tooth preparation finishing line, optimizing the manufacturing casting, predicting facial changes in patients with removable prostheses, and designing removable partial dentures.
MATERIAL AND METHODS
An electronic systematic review was performed in MEDLINE/PubMed, EMBASE, Web of Science, Cochrane, and Scopus. A manual search was also conducted. Studies with artificial intelligence models were selected based on 6 criteria: tooth shade selection, automated fabrication of dental restorations, mapping the finishing line of tooth preparations, optimizing the manufacturing casting process, predicting facial changes in patients with removable prostheses, and designing removable partial dentures. Two investigators independently evaluated the quality assessment of the studies by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies (nonrandomized experimental studies). A third investigator was consulted to resolve lack of consensus.
RESULTS
A total of 36 articles were reviewed and classified into 6 groups based on the application of the artificial intelligence model. One article reported on the development of an artificial intelligence model for tooth shade selection, reporting better shade matching than with conventional visual selection; 14 articles reported on the feasibility of automated design of dental restorations using different artificial intelligence models; 1 artificial intelligence model was able to mark the margin line without manual interaction with an average accuracy ranging from 90.6% to 97.4%; 2 investigations developed artificial intelligence algorithms for optimizing the manufacturing casting process, reporting an improvement of the design process, minimizing the porosity on the cast metal, and reducing the overall manufacturing time; 1 study proposed an artificial intelligence model that was able to predict facial changes in patients using removable prostheses; and 17 investigations that developed clinical decision support, expert systems for designing removable partial dentures for clinicians and educational purposes, computer-aided learning with video interactive programs for student learning, and automated removable partial denture design.
CONCLUSIONS
Artificial intelligence models have shown the potential for providing a reliable diagnostic tool for tooth shade selection, automated restoration design, mapping the preparation finishing line, optimizing the manufacturing casting, predicting facial changes in patients with removable prostheses, and designing removable partial dentures, but they are still in development. Additional studies are needed to further develop and assess their clinical performance.
Topics: Humans; Prosthodontics; Artificial Intelligence; Dental Implants; Tooth; Dental Care; Denture, Partial, Removable
PubMed: 34281697
DOI: 10.1016/j.prosdent.2021.06.001