BMC Oral Health Nov 2020The purpose of this paper is to review the available literature on three-dimensionally printed complete dentures in terms of novel biomaterials, fabrication techniques... (Review)
Review
BACKGROUND
The purpose of this paper is to review the available literature on three-dimensionally printed complete dentures in terms of novel biomaterials, fabrication techniques and workflow, clinical performance and patient satisfaction.
METHODS
The methodology included applying a search strategy, defining inclusion and exclusion criteria, selecting studies and forming tables to summarize the results. Searches of PubMed, Scopus, and Embase databases were performed independently by two reviewers to gather literature published between 2010 and 2020.
RESULTS
A total of 126 titles were obtained from the electronic database, and the application of exclusion criteria resulted in the identification of 21 articles pertaining to printed technology for complete dentures. Current innovations and developments in digital dentistry have successfully led to the fabrication of removable dental prostheses using CAD/CAM technologies. Milled dentures have been studied more than 3D printed ones in the currently available literature. The limited number of clinical studies, mainly case reports, suggest current indications of 3D printing in denture fabrication process to be custom tray, record bases, trial, interim or immediate dentures but not definitive prostheses fabrication. Limitations include poor esthetics and retention, inability to balance occlusion and low printer resolution.
CONCLUSIONS
Initial studies on digital dentures have shown promising short-term clinical performance, positive patient-related results and reasonable cost-effectiveness. 3D printing has potential to modernize and streamline the denture fabrication techniques, materials and workflows. However, more research is required on the existing and developing materials and printers to allow for advancement and increase its application in removable prosthodontics.
Topics: Computer-Aided Design; Denture, Complete; Esthetics, Dental; Humans; Printing, Three-Dimensional; Workflow
PubMed: 33246466
DOI: 10.1186/s12903-020-01328-8 -
Primary Dental Journal Sep 2020Improvements in oral health including increased retention of natural teeth have given rise to a partially dentate older population. Replacement of missing natural teeth...
Improvements in oral health including increased retention of natural teeth have given rise to a partially dentate older population. Replacement of missing natural teeth is important to improve function, aesthetics and quality of life for this patient group. A variety of options are available to replace missing teeth in partially dentate older adults, including fixed, removable and implant retained prostheses. This article will discuss the provision of removable partial dentures including treatment planning and denture design. When planning removable partial dentures, careful attention must be paid to stabilising the patient prior to delivering any prosthesis. Partial dentures should be designed to minimise the potential for plaque accumulation with carefully designed metal based frameworks. Acrylic resin can also be utilised with attention to detail to minimise the risk of damage to delicate supporting tissues. Removable dentures have the advantage that they can be readily added to in the event of further tooth loss which may be particularly relevant for older adults. Partial dentures which optimise support, retention and stability can function very successfully and significantly improve patients' oral health related quality of life.
Topics: Aged; Denture, Partial; Denture, Partial, Removable; Humans; Mouth, Edentulous; Quality of Life; Tooth Loss
PubMed: 32940586
DOI: 10.1177/2050168420943435 -
Hua Xi Kou Qiang Yi Xue Za Zhi = Huaxi... Feb 2021Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which... (Review)
Review
Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which can produce restorations with reliable precision and suitable function. However, the development of digital technologies in the field of complete denture restoration has been slow due to the complexity of prosthesis. This review article introduces the current research status and clinical applications of digital complete dentures in prosthodontic clinics and dental laboratories to provide beneficial references to prosthodontists and dental technicians.
Topics: Computer-Aided Design; Denture, Complete; Printing, Three-Dimensional
PubMed: 33723930
DOI: 10.7518/hxkq.2021.01.001 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
BioMed Research International 2021The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures... (Review)
Review
The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures (RPDs) and how to optimize it. A literature survey was conducted for the English full-text articles, which used only FEA to estimate the stress developed in RPDs from Jan 2000 to May 2021. In RPDs, the retaining and supporting structures are subjected to dynamic loads during insertion and removal of the prosthesis as well as during function. The majority of stresses in free-end saddle (FES) RPDs are concentrated in the shoulder of the clasp, the horizontal curvature of the gingival approaching clasp, and the part of the major connector next to terminal abutments. Clasps fabricated from flexible materials were beneficial to eliminate the stress in the abutment, while rigid materials were preferred for major connectors to eliminate the displacement of the prosthesis. In implant-assisted RPD, the implant receive the majority of the load, thereby reducing the stress on the abutment and reducing the displacement of the prosthesis. The amount of stress in the implant decreases with zero or minimal angulation, using long and wide implants, and when the implants are placed in the first molar area.
Topics: Algorithms; Biomechanical Phenomena; Dental Abutments; Dental Implants; Denture Design; Denture, Partial, Removable; Finite Element Analysis; Humans; Stress, Mechanical
PubMed: 34485518
DOI: 10.1155/2021/5699962 -
The Cochrane Database of Systematic... Apr 2018Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life.
OBJECTIVES
To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people.
SEARCH METHODS
Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the same material and different techniques, or different materials and the same technique. In tooth- and tissue-supported RPD, we included trials comparing the same material and different dual-impression techniques, and different materials with different dual-impression techniques.
DATA COLLECTION AND ANALYSIS
Two review authors independently, and in duplicate, screened studies for eligibility, extracted data, and assessed the risk of bias for each included trial. We expressed results as risk ratios (RR) for dichotomous outcomes, and as mean differences (MD) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CI), using the random-effects model. We constructed 'Summary of findings' tables for the main comparisons and outcomes (participant-reported oral health-related quality of life, quality of the denture, and denture border adjustments).
MAIN RESULTS
We included nine studies in this review. Eight studies involved 485 participants with CD. We assessed six of the studies to be at high risk of bias, and two to be at low risk of bias. We judged one study on RPD with 72 randomised participants to be at high risk of bias.Overall, the quality of the evidence for each comparison and outcome was either low or very low, therefore, results should be interpreted with caution, as future research is likely to change the findings.Complete denturesTwo studies compared the same material and different techniques (one study contributed data to a secondary outcome only); two studies compared the same technique and different materials; and four studies compared different materials and techniques.One study (10 participants) evaluated two stage-two step, Biofunctional Prosthetic system (BPS) using additional silicone elastomer compared to conventional methods, and found no evidence of a clear difference for oral health-related quality of life, or quality of the dentures (denture satisfaction). The study reported that BPS required fewer adjustments. We assessed the quality of the evidence as very low.One study (27 participants) compared selective pressure final-impression technique using wax versus polysulfide elastomeric (rubber) material. The study did not measure quality of life or dentures, and found no evidence of a clear difference between interventions in the need for adjustments (RR 0.81, 95% CI 0.38 to 1.70). We assessed the quality of the evidence as very low.One study compared two stage-two step final impression with alginate versus silicone elastomer. Oral health-related quality of life measured by the OHIP-EDENT seemed to be better with silicone (MD 7.20, 95% CI 2.71 to 11.69; 144 participants). The study found no clear differences in participant-reported quality of the denture (comfort) after a two-week 'confirmation' period, but reported that silicone was better for stability and chewing efficiency. We assessed the quality of the evidence as low.Three studies compared single-stage impressions with alginate versus two stage-two step with elastomer (silicone, polysulfide, or polyether) impressions. There was no evidence of a clear difference in the OHIP-EDENT at one month (MD 0.05, 95% CI -2.37 to 2.47; two studies, 98 participants). There was no evidence of a clear difference in participant-rated general satisfaction with dentures at six months (MD 0.00, 95% CI -8.23 to 8.23; one study, 105 participants). We assessed the quality of the evidence as very low.One study compared single-stage alginate versus two stage-two step using zinc-oxide eugenol, and found no evidence of a clear difference in OHIP-EDENT (MD 0.50, 95% CI -2.67 to 3.67; 39 participants), or general satisfaction (RR 3.15, 95% CI 0.14 to 72.88; 39 participants) at six months. We assessed the quality of the evidence as very low.Removable partial denturesOne study randomised 72 participants and compared altered-cast technique versus one-piece cast technique. The study did not measure quality of life, but reported that most participants were satisfied with the dentures and there was no evidence of any clear difference between groups for general satisfaction at one-year follow-up (low-quality evidence). There was no evidence of a clear difference in number of intaglio adjustments at one year (RR 1.43, 95% CI 0.61 to 3.34) (very low-quality evidence).
AUTHORS' CONCLUSIONS
We conclude that there is no clear evidence that one technique or material has a substantial advantage over another for making complete dentures and removable partial dentures. Available evidence for the relative benefits of different denture fabrication techniques and final-impression materials is limited and is of low or very low quality. More high-quality RCTs are required.
Topics: Dental Impression Materials; Dental Impression Technique; Denture Design; Denture Retention; Denture, Partial, Removable; Dentures; Humans; Mouth, Edentulous; Quality of Life; Randomized Controlled Trials as Topic
PubMed: 29617037
DOI: 10.1002/14651858.CD012256.pub2 -
Letters in Applied Microbiology Aug 2022The United Nations suggests the global population of denture wearers (an artificial device that acts as a replacement for teeth) is likely to rise significantly by the... (Review)
Review
The United Nations suggests the global population of denture wearers (an artificial device that acts as a replacement for teeth) is likely to rise significantly by the year 2050. Dentures become colonized by microbial biofilms, the composition of which is influenced by complex factors such as patient's age and health, and the nature of the denture material. Since colonization (and subsequent biofilm formation) by some micro-organisms can significantly impact the health of the denture wearer, the study of denture microbiology has long been of interest to researchers. The specific local and systemic health risks of denture plaque are different from those of dental plaque, particularly with respect to the presence of the opportunist pathogen Candida albicans and various other nonoral opportunists. Here, we reflect on advancements in our understanding of the relationship between micro-organisms, dentures, and the host, and highlight how our growing knowledge of the microbiome, biofilms, and novel antimicrobial technologies may better inform diagnosis, treatment, and prevention of denture-associated infections, thereby enhancing the quality and longevity of denture wearers.
Topics: Anti-Infective Agents; Biofilms; Candida albicans; Dentures; Humans; Microbiota
PubMed: 35634756
DOI: 10.1111/lam.13751 -
British Dental Journal Jul 2022Dentures are an excellent treatment modality for partial and edentate patients; however, improper denture care and hygiene can result in both decreased longevity of the...
Dentures are an excellent treatment modality for partial and edentate patients; however, improper denture care and hygiene can result in both decreased longevity of the prosthesis and increased risk of developing dental caries, periodontal disease and oral candidosis. Previously, it has been shown that patients and dental professionals are unaware of the different materials and methods available for optimum denture care and hygiene. This article provides an overview of the key legislation and main commercially available methods for denture cleanliness and hygiene, and serves as a basis for providing tailored denture hygiene for denture wearers.
Topics: Dental Caries; Dentures; Humans; Hygiene; Periodontal Diseases
PubMed: 35804119
DOI: 10.1038/s41415-022-4397-1 -
Dental Materials Journal Jan 2009In this article, we review the recent history of the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures (FPDs), based on our... (Review)
Review
In this article, we review the recent history of the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures (FPDs), based on our 20 years of experience in this field. The current status of commercial dental CAD/CAM systems developed around the world is evaluated, with particular focus on the field of ceramic crowns and FPDs. Finally, we discuss the future perspectives applicable to dental CAD/CAM. The use of dental CAD/CAM systems is promising not only in the field of crowns and FPDs but also in other fields of dentistry, even if the contribution is presently limited. CAD/CAM technology will contribute to patients' health and QOL in the aging society.
Topics: Computer-Aided Design; Crowns; Dental Porcelain; Dental Prosthesis Design; Dental Restoration, Permanent; Denture Design; Denture, Partial, Fixed; Equipment Design; Forecasting; Humans; Laboratories, Dental; Technology, Dental
PubMed: 19280967
DOI: 10.4012/dmj.28.44 -
BioMed Research International 2021Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional...
OBJECTIVE
Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques.
MATERIALS AND METHODS
The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included.
RESULTS
Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast (41.677 ± 15.546 m) were found in RPDs constructed through digital CAD/CAM systems.
CONCLUSION
A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.
Topics: Computer-Aided Design; Denture Design; Denture, Partial; Denture, Partial, Removable; Humans; Lasers; Workflow
PubMed: 34532499
DOI: 10.1155/2021/3194433