-
BMC Public Health Mar 2020The effectiveness of female condoms for preventing HIV and sexually transmitted infections (STIs) remains inconclusive. We examined the effects of female condoms on the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The effectiveness of female condoms for preventing HIV and sexually transmitted infections (STIs) remains inconclusive. We examined the effects of female condoms on the acquisition of HIV and STIs.
METHODS
We searched four databases, two trial registries, and reference lists of relevant publications in October 2018 and updated our search in February 2020. We screened search output, evaluated study eligibility, and extracted data in duplicate; resolving differences through discussion. We calculated the effective sample size of cluster randomised trials using an intra-cluster correlation coefficient of 0·03. Data from similar studies were combined in a meta-analysis. We performed a non-inferiority analysis of new condoms relative to marketed ones using a non-inferiority margin of 3%. We assessed the certainty of evidence using GRADE.
RESULTS
We included fifteen studies of 6921 women. We found that polyurethane female condoms (FC1) plus male condoms may be as effective as male condoms only in reducing HIV acquisition (1 trial, n = 149 women, RR 0.07, 95%CI 0.00-1.38; low-certainty evidence). However, the use of FC1 plus male condoms is superior to male condoms alone in reducing the acquisition of gonorrhoea (2 trials, n = 790, RR 0.59, 95%CI 0.41-0.86; high-certainty evidence) and chlamydia (2 trials, n = 790, RR 0.67, 95%CI 0.47-0.94; high-certainty evidence). Adverse events and failure rates of FC1 were very low and decreased during follow up. Although the functionality of newer female condoms (Woman's, Cupid, Pheonurse, Velvet, and Reddy) may be non-inferior to FC2, there were no available studies assessing their efficacy in preventing HIV and STIs.
CONCLUSION
The use of female plus male condoms is more effective than use of male condoms only in preventing STIs and may be as effective as the male condom only in preventing HIV. There is a need for well conducted studies assessing the effects of newer female condoms on HIV and STIs.
PROSPERO REGISTRATION NUMBER
CRD42018090710.
Topics: Condoms, Female; Female; HIV Infections; Humans; Randomized Controlled Trials as Topic; Sexually Transmitted Diseases
PubMed: 32164652
DOI: 10.1186/s12889-020-8384-7 -
The Cochrane Database of Systematic... Feb 2021Extracranial carotid artery stenosis is the major cause of stroke, which can lead to disability and mortality. Carotid endarterectomy (CEA) with carotid patch... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extracranial carotid artery stenosis is the major cause of stroke, which can lead to disability and mortality. Carotid endarterectomy (CEA) with carotid patch angioplasty is the most popular technique for reducing the risk of stroke. Patch material may be made from an autologous vein, bovine pericardium, or synthetic material including polytetrafluoroethylene (PTFE), Dacron, polyurethane, and polyester. This is an update of a review that was first published in 1996 and was last updated in 2010.
OBJECTIVES
To assess the safety and efficacy of different types of patch materials used in carotid patch angioplasty. The primary hypothesis was that a synthetic material was associated with lower risk of patch rupture versus venous patches, but that venous patches were associated with lower risk of perioperative stroke and early or late infection, or both.
SEARCH METHODS
We searched the Cochrane Stroke Group trials register (last searched 25 May 2020); the Cochrane Central Register of Controlled Trials (CENTRAL; 2020, Issue 4), in the Cochrane Library; MEDLINE (1966 to 25 May 2020); Embase (1980 to 25 May 2020); the Index to Scientific and Technical Proceedings (1980 to 2019); the Web of Science Core Collection; ClinicalTrials.gov; and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) portal. We handsearched relevant journals and conference proceedings, checked reference lists, and contacted experts in the field.
SELECTION CRITERIA
Randomised and quasi-randomised trials (RCTs) comparing one type of carotid patch with another for CEA.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed eligibility, risk of bias, and trial quality; extracted data; and determined the quality of evidence using the GRADE approach. Outcomes, for example, perioperative ipsilateral stroke and long-term ipsilateral stroke (at least one year), were collected and analysed.
MAIN RESULTS
We included 14 trials involving a total of 2278 CEAs with patch closure operations: seven trials compared vein closure with PTFE closure, five compared Dacron grafts with other synthetic materials, and two compared bovine pericardium with other synthetic materials. In most trials, a patient could be randomised twice and could have each carotid artery randomised to different treatment groups. Synthetic patch compared with vein patch angioplasty Vein patch may have little to no difference in effect on perioperative ipsilateral stroke between synthetic versus vein materials, but the evidence is very uncertain (odds ratio (OR) 2.05, 95% confidence interval (CI) 0.66 to 6.38; 5 studies, 797 participants; very low-quality evidence). Vein patch may have little to no difference in effect on long-term ipsilateral stroke between synthetic versus vein materials, but the evidence is very uncertain (OR 1.45, 95% CI 0.69 to 3.07; P = 0.33; 4 studies, 776 participants; very low-quality evidence). Vein patch may increase pseudoaneurysm formation when compared with synthetic patch, but the evidence is very uncertain (OR 0.09, 95% CI 0.02 to 0.49; 4 studies, 776 participants; very low-quality evidence). However, the numbers involved were small. Dacron patch compared with other synthetic patch angioplasty Dacron versus PTFE patch materials PTFE patch may reduce the risk of perioperative ipsilateral stroke (OR 3.35, 95% CI 0.19 to 59.06; 2 studies, 400 participants; very low-quality evidence). PTFE patch may reduce the risk of long-term ipsilateral stroke (OR 1.52, 95% CI 0.25 to 9.27; 1 study, 200 participants; very low-quality evidence). Dacron may result in an increase in perioperative combined stroke and transient ischaemic attack (TIA) (OR 4.41 95% CI 1.20 to 16.14; 1 study, 200 participants; low-quality evidence) when compared with PTFE. Early arterial re-stenosis or occlusion (within 30 days) was also higher for Dacron patches. During follow-up for longer than one year, more 'any strokes' (OR 10.58, 95% CI 1.34 to 83.43; 2 studies, 304 participants; low-quality evidence) and stroke/death (OR 6.06, 95% CI 1.31 to 28.07; 1 study, 200 participants; low-quality evidence) were reported with Dacron patch closure, although numbers of outcome events were small. Dacron patch may increase the risk of re-stenosis when compared with other synthetic materials (especially with PTFE), but the evidence is very uncertain (OR 3.73, 95% CI 0.71 to 19.65; 3 studies, 490 participants; low-quality evidence). Bovine pericardium patch compared with other synthetic patch angioplasty Bovine pericardium versus PTFE patch materials Evidence suggests that bovine pericardium patch results in a reduction in long-term ipsilateral stroke (OR 4.17, 95% CI 0.46 to 38.02; 1 study, 195 participants; low-quality evidence). Bovine pericardial patch may reduce the risk of perioperative fatal stroke, death, and infection compared to synthetic material (OR 5.16, 95% CI 0.24 to 108.83; 2 studies, 290 participants; low-quality evidence for PTFE, and low-quality evidence for Dacron; OR 4.39, 95% CI 0.48 to 39.95; 2 studies, 290 participants; low-quality evidence for PTFE, and low-quality evidence for Dacron; OR 7.30, 95% CI 0.37 to 143.16; 1 study, 195 participants; low-quality evidence, respectively), but the numbers of outcomes were small. The evidence is very uncertain about effects of the patch on infection outcomes.
AUTHORS' CONCLUSIONS
The number of outcome events is too small to allow conclusions, and more trial data are required to establish whether any differences do exist. Nevertheless, there is little to no difference in effect on perioperative and long-term ipsilateral stroke between vein and any synthetic patch material. Some evidence indicates that other synthetic patches (e.g. PTFE) may be superior to Dacron grafts in terms of perioperative stroke and TIA rates, and both early and late arterial re-stenosis and occlusion. Pseudoaneurysm formation may be more common after use of a vein patch than after use of a synthetic patch. Bovine pericardial patch, which is an acellular xenograft material, may reduce the risk of perioperative fatal stroke, death, and infection compared to other synthetic patches. Further large RCTs are required before definitive conclusions can be reached.
Topics: Aneurysm, False; Angioplasty; Bias; Bioprosthesis; Blood Vessel Prosthesis; Carotid Stenosis; Endarterectomy, Carotid; Humans; Polyethylene Terephthalates; Polytetrafluoroethylene; Postoperative Complications; Randomized Controlled Trials as Topic; Saphenous Vein; Stroke
PubMed: 33598915
DOI: 10.1002/14651858.CD000071.pub4 -
The Cochrane Database of Systematic... May 2022Sacrococcygeal pilonidal sinus disease is a common debilitating condition that predominantly affects young adults, with a profound impact on their activities of daily... (Review)
Review
BACKGROUND
Sacrococcygeal pilonidal sinus disease is a common debilitating condition that predominantly affects young adults, with a profound impact on their activities of daily living. The condition is treated surgically, and in some cases the wound in the natal cleft is left open to heal by itself. Many dressings and topical agents are available to aid healing of these wounds.
OBJECTIVES
To assess the effects of dressings and topical agents for the management of open wounds following surgical treatment for sacrococcygeal pilonidal sinus in any care setting.
SEARCH METHODS
In March 2021, we searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase and EBSCO CINAHL Plus. We also searched clinical trials registries for ongoing and unpublished studies, and we scanned reference lists of included studies, reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting.
SELECTION CRITERIA
We included parallel-group randomised controlled trials (RCTs) only. We included studies with participants who had undergone any type of sacrococcygeal pilonidal sinus disease surgery and were left with an open wound.
DATA COLLECTION AND ANALYSIS
We used the standard methodological procedures expected by Cochrane. We used GRADE to assess the certainty of the evidence for each outcome.
MAIN RESULTS
We included 11 RCTs comprising 932 participants. Two studies compared topical negative pressure wound therapy (TNPWT) with conventional open wound healing, two studies compared platelet-rich plasma with sterile absorbent gauze, and the other seven studies compared various dressings and topical agents. All studies were at high risk of bias in at least one domain, whilst one study was judged to be at low risk of bias in all but one domain. All studies were conducted in secondary care. Mean participant ages were between 20 and 30 years, and nearly 80% of participants were male. No studies provided data on quality of life, cost-effectiveness, pain at first dressing change or proportion of wounds healed at 6 or 12 months, and very few adverse effects were recorded in any study. It is unclear whether TNPWT reduces time to wound healing compared with conventional open wound healing (comparison 1), as the certainty of evidence is very low. The two studies provided conflicting results, with one study showing benefit (mean difference (MD) -24.01 days, 95% confidence interval (CI) -35.65 to -12.37; 19 participants), whilst the other reported no difference. It is also unclear whether TNPWT has any effect on the proportion of wounds healed by 30 days (risk ratio (RR) 3.60, 95% CI 0.49 to 26.54; 19 participants, 1 study; very low-certainty evidence). Limited data were available for our secondary outcomes time to return to normal daily activities and recurrence rate; we do not know whether TNPWT has any effect on these outcomes. Lietofix cream may increase the proportion of wounds that heal by 30 days compared with an iodine dressing (comparison 4; RR 8.06, 95% CI 1.05 to 61.68; 205 participants, 1 study; low-certainty evidence). The study did not provide data on time to wound healing. We do not know whether hydrogel dressings reduce time to wound healing compared with wound cleaning with 10% povidone iodine (comparison 5; MD -24.54 days, 95% CI -47.72 to -1.36; 31 participants, 1 study; very low-certainty evidence). The study did not provide data on the proportion of wounds healed. It is unclear whether hydrogel dressings have any effect on adverse effects as the certainty of the evidence is very low. Platelet-rich plasma may reduce time to wound healing compared with sterile absorbent gauze (comparison 6; MD -19.63 days, 95% CI -34.69 to -4.57; 210 participants, 2 studies; low-certainty evidence). No studies provided data on the proportion of wounds healed. Platelet-rich plasma may reduce time to return to normal daily activities (MD -15.49, 95% CI -28.95 to -2.02; 210 participants, 2 studies; low-certainty evidence). Zinc oxide mesh may make little or no difference to time to wound healing compared with placebo (comparison 2; median 54 days in the zinc oxide mesh group versus 62 days in the placebo mesh group; low-certainty evidence). We do not know whether zinc oxide mesh has an effect on the proportion of wounds healed by 30 days as the certainty of the evidence is very low (RR 2.35, 95% CI 0.49 to 11.23). It is unclear whether gentamicin-impregnated collagen sponge reduces time to wound healing compared with no dressing (comparison 7; MD -1.40 days, 95% CI -5.05 to 2.25; 50 participants, 1 study; very low-certainty evidence). The study did not provide data on the proportion of wounds healed. Dialkylcarbamoyl chloride (DACC)-coated dressings may make little or no difference to time to wound healing compared with alginate dressings (comparison 8; median 69 (95% CI 62 to 72) days in the DACC group versus 71 (95% CI 69 to 85) days in the alginate group; 1 study, 246 participants; low-certainty evidence). One study compared a polyurethane foam hydrophilic dressing with an alginate dressing (comparison 3) whilst another study compared a hydrocolloid dressing with an iodine dressing (comparison 9). It is unclear whether either intervention has any effect on time to wound healing as the certainty of evidence is very low.
AUTHORS' CONCLUSIONS
At present, the evidence that any of the dressings or topical agents contained in this review have a benefit on time to wound healing, the proportion of wounds that heal at a specific time point or on any of the secondary outcomes of our review ranges from low certainty to very low certainty. There is low-certainty evidence on the benefit on wound healing of platelet-rich plasma from two studies and of Lietofix cream and hydrogel dressings from single studies. Further studies are required to investigate these interventions further.
Topics: Adult; Alginates; Bandages; Female; Humans; Hydrogels; Iodine; Male; Pilonidal Sinus; Young Adult; Zinc Oxide
PubMed: 35593897
DOI: 10.1002/14651858.CD013439.pub2 -
The Cochrane Database of Systematic... Jan 2020It is estimated that up to 1% of people in high-income countries suffer from a leg ulcer at some time in their life. The majority of leg ulcers are associated with... (Meta-Analysis)
Meta-Analysis
BACKGROUND
It is estimated that up to 1% of people in high-income countries suffer from a leg ulcer at some time in their life. The majority of leg ulcers are associated with circulation problems; poor blood return in the veins causes venous ulcers (around 70% of ulcers) and poor blood supply to the legs causes arterial ulcers (around 22% of ulcers). Treatment of arterial leg ulcers is directed towards correcting poor arterial blood supply, for example by correcting arterial blockages (either surgically or pharmaceutically). If the blood supply has been restored, these arterial ulcers can heal following principles of good wound-care. Dressings and topical agents make up a part of good wound-care for arterial ulcers, but there are many products available, and it is unclear what impact these have on ulcer healing. This is the third update of a review first published in 2003.
OBJECTIVES
To determine whether topical agents and wound dressings affect healing in arterial ulcers. To compare healing rates and patient-centred outcomes between wound dressings and topical agents.
SEARCH METHODS
The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, Cochrane Central Register of Controlled Trials, MEDLINE, Embase, Cumulative Index to Nursing and Allied Health Literature and Allied and Complementary Medicine databases, the World Health Organization International Clinical Trials Registry Platform and ClinicalTrials.gov trials register to 28 January 2019.
SELECTION CRITERIA
Randomised controlled trials (RCTs), or controlled clinical trials (CCTs) evaluating dressings and topical agents in the treatment of arterial leg ulcers were eligible for inclusion. We included participants with arterial leg ulcers irrespective of method of diagnosis. Trials that included participants with mixed arterio-venous disease and diabetes were eligible for inclusion if they presented results separately for the different groups. All wound dressings and topical agents were eligible for inclusion in this review. We excluded trials which did not report on at least one of the primary outcomes (time to healing, proportion completely healed, or change in ulcer area).
DATA COLLECTION AND ANALYSIS
Two review authors independently extracted information on the participants' characteristics, the interventions, and outcomes using a standardised data extraction form. Review authors resolved any disagreements through discussion. We presented the data narratively due to differences in the included trials. We used GRADE to assess the certainty of the evidence.
MAIN RESULTS
Two trials met the inclusion criteria. One compared 2% ketanserin ointment in polyethylene glycol (PEG) with PEG alone, used twice a day by 40 participants with arterial leg ulcers, for eight weeks or until healing, whichever was sooner. One compared topical application of blood-derived concentrated growth factor (CGF) with standard dressing (polyurethane film or foam); both applied weekly for six weeks by 61 participants with non-healing ulcers (venous, diabetic arterial, neuropathic, traumatic, or vasculitic). Both trials were small, reported results inadequately, and were of low methodological quality. Short follow-up times (six and eight weeks) meant it would be difficult to capture sufficient healing events to allow us to make comparisons between treatments. One trial demonstrated accelerated wound healing in the ketanserin group compared with the control group. In the trial that compared CGF with standard dressings, the number of participants with diabetic arterial ulcers were only reported in the CGF group (9/31), and the number of participants with diabetic arterial ulcers and their data were not reported separately for the standard dressing group. In the CGF group, 66.6% (6/9) of diabetic arterial ulcers showed more than a 50% decrease in ulcer size compared to 6.7% (2/30) of non-healing ulcers treated with standard dressing. We assessed this as very-low certainty evidence due to the small number of studies and arterial ulcer participants, inadequate reporting of methodology and data, and short follow-up period. Only one trial reported side effects (complications), stating that no participant experienced these during follow-up (six weeks, low-certainty evidence). It should also be noted that ketanserin is not licensed in all countries for use in humans. Neither study reported time to ulcer healing, patient satisfaction or quality of life.
AUTHORS' CONCLUSIONS
There is insufficient evidence to determine whether the choice of topical agent or dressing affects the healing of arterial leg ulcers.
Topics: Administration, Topical; Arteries; Bandages, Hydrocolloid; Humans; Leg Ulcer; Occlusive Dressings; Ointments; Randomized Controlled Trials as Topic; Varicose Ulcer; Wound Healing
PubMed: 31978262
DOI: 10.1002/14651858.CD001836.pub4 -
Evidence-based Dentistry Mar 2024The clinical effectiveness of clear aligners depends on the material properties both physical and mechanical. The purpose of this systematic review is to evaluate the...
INTRODUCTION
The clinical effectiveness of clear aligners depends on the material properties both physical and mechanical. The purpose of this systematic review is to evaluate the physical and mechanical properties of different clear aligner materials and changes in the same during and after intra-oral use.
METHODS
Search was done in five electronic databases: Pubmed, Embase, Scopus, Web of Science and Ovid individually by two reviewers. In vivo, Ex vivo and In vitro studies that evaluated the physical and mechanical properties of clear aligner materials were selected. The risk of bias assessment was performed using a modified Cochrane risk of bias tool.
RESULTS
From the 24 articles selected, 19 evaluated a single physical property and 23 articles evaluated a single mechanical property of clear aligner materials. All domains in the risk of bias assessment showed low risk of bias except for 'blinding of outcome' which was unclear in almost all the selected studies. Properties such as hardness, optical properties, stiffness, and yield strength were found to be different for different clear aligner materials and were found to change with thermoforming, with intra-oral aging, and in simulated intraoral conditions. Due to heterogenicity in the parameters used to assess physical or mechanical properties a meta-analysis could not be done.
CONCLUSIONS
Properties like hardness, color, stiffness, stress relaxation and creep behavior were different for various clear aligner materials and were found to deteriorate with thermoforming and intra-oral aging. Polyurethane-based materials have a higher level of hardness and stiffness but exhibit increased creep and stress relaxation properties.
PROSPERO REGISTRATION NUMBER
CRD42021269597.
Topics: Humans; Tooth Movement Techniques; Polyurethanes; Treatment Outcome; Physical Examination; Orthodontic Appliances, Removable
PubMed: 38017152
DOI: 10.1038/s41432-023-00937-w -
Medicine Mar 2021The aim of this meta-analysis with trial sequential analysis (TSA) was to evaluate the effect of a polyurethane (PU) tracheal tube cuff on the prevention of... (Meta-Analysis)
Meta-Analysis
Comparison of polyurethane tracheal tube cuffs and conventional polyvinyl chloride tube cuff for prevention of ventilator-associated pneumonia: A systematic review with meta-analysis.
BACKGROUND
The aim of this meta-analysis with trial sequential analysis (TSA) was to evaluate the effect of a polyurethane (PU) tracheal tube cuff on the prevention of ventilator-associated pneumonia (VAP).
METHODS
We performed a systematic search using the MEDLINE database through PubMed, Cochrane Central Register of Controlled Trial, SCOPUS, and Web of Science.Randomized controlled trials comparing the incidence of VAP and clinically relevant outcomes between PU cuff tubes and polyvinyl chloride (PVC) cuff tubes in adult patients. Two authors independently extracted study details, patient characteristics, and clinical outcomes such as incidence of VAP, bacterial colonization of tracheal aspirate, duration of mechanical ventilation, ICU stay, and ICU mortality.
RESULTS
From 309 studies identified as potentially eligible, six studies with 1226 patients were included in this meta-analysis. All studies compared the incidence of VAP between PU cuffs and PVC cuffs. Use of a PU cuff was not associated with a reduction in VAP incidence (RR = 0.68; 95% CI, 0.45-1.03) with significant statistical heterogeneity (I2 = 65%). The quality of evidence was "very low." According to the TSA, the actual sample size was only 15.8% of the target sample size, and the cumulative Z score did not cross the trial sequential monitoring boundary for benefit. No positive impact was reported for the other relevant outcomes for PU cuffs.
CONCLUSIONS
The use of a PU cuff for mechanical ventilation did not prevent VAP. Further trials with a low risk of bias need to be performed.
Topics: Equipment Design; Humans; Intensive Care Units; Intubation, Intratracheal; Pneumonia, Ventilator-Associated; Polyurethanes; Polyvinyl Chloride; Respiration, Artificial
PubMed: 33655952
DOI: 10.1097/MD.0000000000024906 -
Journal of Pharmacy & Bioallied Sciences Feb 2024This systematic review examines the efficacy and biocompatibility of orthodontic clear aligner tooth aligners constructed from polyethylene terephthalate glycol (PeT-G),...
Effectiveness and Biocompatibility of Tooth Aligners Made from Polyethylene Terephthalate Glycol (PeT-G), Polypropylene (PP), Polycarbonate (PC), Thermoplastic Polyurethanes (TPUs), and Ethylene-Vinyl Acetate (EVA): A Systematic Review.
OBJECTIVE
This systematic review examines the efficacy and biocompatibility of orthodontic clear aligner tooth aligners constructed from polyethylene terephthalate glycol (PeT-G), polypropylene (PP), polycarbonate (PC), thermoplastic polyurethanes (TPUs), and ethylene-vinyl acetate (EVA).
MATERIALS AND METHODS
To find relevant papers published through September 2021, PubMed was searched extensively. Randomized clinical trials (RCTs) and observational studies assessing the effectiveness and biocompatibility of the aligner materials were included. Data were extracted independently, and the quality of included research was appraised using relevant procedures. The research variability necessitated a narrative synthesis.
RESULTS
Five studies were included for comparison. All materials were biocompatible; however, PeT-G and EVA aligners caused the least tissue irritation. Patients preferred TPU aligners for initial comfort and PeT-G aligners for transparency and endurance.
CONCLUSION
Biocompatible PeT-G, PP, PC, TPU, and EVA tooth aligners fix malocclusions. Aligner materials should be chosen based on patient preferences, treatment goals, and material qualities. For stronger proof, a longer-term study is needed.
PubMed: 38595485
DOI: 10.4103/jpbs.jpbs_883_23 -
Supportive Care in Cancer : Official... Feb 2020To identify the most effective dressing for covering long-term central venous catheter exit site to prevent catheter-related infections and skin irritation in patients...
PURPOSE
To identify the most effective dressing for covering long-term central venous catheter exit site to prevent catheter-related infections and skin irritation in patients undergoing hematopoietic stem cell transplantation.
METHODS
Systematic Review. The search was performed in the following electronic databases: CINAHL, Cochrane Library CENTRAL, EMBASE, LILACS, PubMed, Scopus, and Web of Science. Google Scholar was used for the gray literature search.
RESULTS
Seven studies were included which tested different arrangements of dressings: sterilized gauze and adhesive tape with a transparent polyurethane film (n = 2), transparent polyurethane film with a different replacement interval frequency (n = 2), transparent polyurethane film with and without chlorhexidine released continuously by the dressing at the site of intravascular catheter insertion (n = 2), and dressings vs. no dressings (n = 1). The meta-analysis for catheter-related infection prevention showed no difference between type of dressing (RR 1.76, [95% CI 0.82; 3.75], I 0%) and for the replacement frequency at different intervals (RR 1.04, [95% CI 0.67; 1.61], I 0%). The meta-analysis for skin irritation evaluated the transparent polyurethane film replacement frequency and indicated that a longer dressing replacement interval (10 to 15 days) reduces the risk of developing this outcome (RR 0.71, 0.52; 0.96, 95% CI, I 24%).
CONCLUSIONS
Regarding the type of the dressing, there is no evidence indicating the best dressing. Although there is no evidence available for the ideal replacement frequency, the risk to develop skin irritation is reduced in longer dressing replacements intervals.
Topics: Bandages; Catheter-Related Infections; Central Venous Catheters; Hematopoietic Stem Cell Transplantation; Humans; Polyurethanes
PubMed: 31493134
DOI: 10.1007/s00520-019-05065-9 -
The Cochrane Database of Systematic... May 2024Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection.
OBJECTIVES
To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people.
SEARCH METHODS
We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people.
DATA COLLECTION AND ANALYSIS
Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence).
AUTHORS' CONCLUSIONS
There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.
Topics: Humans; Randomized Controlled Trials as Topic; Catheterization, Peripheral; Bandages; Catheter-Related Infections; Polyurethanes; Bias; Equipment Failure
PubMed: 38780138
DOI: 10.1002/14651858.CD013023.pub2 -
Critical Reviews in Analytical Chemistry 2024Knowing the impacts of bisphenol A (BPA) on human health, this systematic review aimed to gather the analytical methods for the quantification of BPA release of BPA in... (Review)
Review
Knowing the impacts of bisphenol A (BPA) on human health, this systematic review aimed to gather the analytical methods for the quantification of BPA release of BPA in dental materials in and (biological fluids) studies. A brief critical discussion of the impacts of BPA on human health and the possible association with BPA in dental materials was also presented. The research was carried out by three independent researchers, (according to PRISMA guidelines) in PUBMED and SCOPUS databases, by searching for specific keywords and articles published between January 2011 and February 2022. Seventeen articles met the eligibility criteria and were included in this systematic review: 10 and 7 . In studies, the highest amounts of BPA released were from flowable to conventional resins, followed by resin-modified glass ionomer. In contrast, the smallest amount was released from "BPA-free" composites and CAD-CAM blocks. Regarding studies, a higher concentration of BPA were found in saliva than urine or blood. The best analytical method for trace quantifying BPA is LC-MS/MS (Liquid Chromatography with Tandem Mass Spectrometry) due to its selectivity, low quantification limits, and the unequivocal identification. However, further studies are required to develop faster and more sensitive methods, in order to obtain more reliable results.
Topics: Benzhydryl Compounds; Phenols; Composite Resins; Humans; Tandem Mass Spectrometry; Dental Materials; Chromatography, Liquid; Acrylic Resins; Polyurethanes
PubMed: 35776702
DOI: 10.1080/10408347.2022.2093097