European Respiratory Review : An... Sep 2022Respiratory oscillometry is gaining global attention over traditional pulmonary function tests for its sensitivity in detecting small airway obstructions. However, its... (Review)
Review
Respiratory oscillometry is gaining global attention over traditional pulmonary function tests for its sensitivity in detecting small airway obstructions. However, its use in clinical settings as a diagnostic tool is limited because oscillometry lacks globally accepted reference values. In this scoping review, we systematically assessed the differences between selected oscillometric reference equations with the hypothesis that significant heterogeneity existed between them. We searched bibliographic databases, registries and references for studies that developed equations for healthy adult populations according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A widely used Caucasian model was used as the standard reference and compared against other models using Bland-Altman and Lin's concordance correlational analyses. We screened 1202 titles and abstracts, and after a full-text review of 67 studies, we included 10 in our analyses. Of these, three models had a low-to-moderate agreement with the reference model, particularly those developed from non-Caucasian populations. Although the other six models had a moderate-to-high agreement with the standard model, there were still significant sex-specific variations. This is the first systematic analysis of the heterogeneity between oscillometric reference models and warrants the validation of appropriate equations in clinical applications of oscillometry to avoid diagnostic errors.
Topics: Female; Humans; Male; Oscillometry; Reference Values; Respiratory Function Tests
PubMed: 35831009
DOI: 10.1183/16000617.0021-2022 -
Anaesthesiology Intensive Therapy 2022Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP)... (Meta-Analysis)
Meta-Analysis Review
Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP) measurement are its easy and fast methodology; however, the accuracy and the precision of this measurement in critically ill patients is constantly debated. We performed a systematic review and meta-analysis of observational studies comparing oscillometric NIBP methods with invasive arterial pressure (IAP) measurements. We included studies of adult critically ill patients, which evaluated MAP in the same patient by both NIBP and IAP at any site. We included only studies comparing simultaneous measurements of arterial pressure by NIBP and IAP, reporting their results using mean difference and SD of agreement. The main outcome was to define the bias of the MAP measured by NIBP over the IAP measurement. The quality of the studies was analysed by the QUADAS 2 tool. Seven studies and 1593 patients were included in the main analysis. The oscillometric NIBP method had a mean value of -1.50 mmHg when compared with IAP (95% CI: -3.34 to 0.35; I2 = 96% for random effects model, P < 0.01). The limits of agreement for MAP varied between -14.6 mmHg and +40.3 mmHg. NIBP had an adequate accuracy regarding MAP measurements by oscillometry. Limits of agreement may thus narrow the clinical applicability in scenarios in which there is a need for a more precise management of blood pressure.
Topics: Adult; Humans; Blood Pressure; Blood Pressure Determination; Oscillometry; Critical Illness; Arterial Pressure
PubMed: 36734453
DOI: 10.5114/ait.2022.123120 -
Children (Basel, Switzerland) Sep 2021Spirometry is considered the gold standard method for monitoring lung function of patients with cystic fibrosis (CF) but it requires patients' cooperation and therefore... (Review)
Review
Spirometry is considered the gold standard method for monitoring lung function of patients with cystic fibrosis (CF) but it requires patients' cooperation and therefore it is not useful for the majority of preschool-aged children. Oscillometry is an alternative modality for lung function monitoring that requires minimal cooperation and can be applied in children as young as 3 years of age. Furthermore, it generates lesser aerosol compared to spirometry, an issue that is of considerable importance in the COVID-19 era. The aim of this review was to present the existing clinical data regarding the application of oscillometry in children and adolescents with CF. The method seems to have acceptable feasibility and repeatability. However, there is conflicting data regarding the correlation of oscillometry values with the clinical symptoms of CF patients either in clinically stable or in exacerbation periods. Furthermore, it is not clear to what extent oscillometry measurements correlate with the spirometry indices. Based on current evidence, spirometry cannot be substituted by oscillometry in the monitoring of the respiratory status of children and adolescents with CF.
PubMed: 34682122
DOI: 10.3390/children8100857 -
International Journal of Chronic... 2021Bronchodilator responsiveness (BDR) is commonly used in the diagnosis of lung disease. Although small airways dysfunction is a feature of asthma and COPD, physiological...
BACKGROUND
Bronchodilator responsiveness (BDR) is commonly used in the diagnosis of lung disease. Although small airways dysfunction is a feature of asthma and COPD, physiological tests of small airways are not included in guidelines for BDR testing. This systematic review assessed the current evidence of BDR using small airways function in asthma and COPD.
METHODS
The systematic review used standard methodology with the protocol prospectively registered on PROSPERO (CRD42020164140). Electronic medical databases (EMBASE and Medline) were searched using related keywords. Abstracts and full texts were screened independently by two reviewers. Studies that reported the change of physiological small airways function and FEV were included in the review. The revised Cochrane risk of bias tool for RCT and NIH quality assessment tool for cohort and cross-sectional studies were used to evaluate the studies.
RESULTS
A total of 934 articles were identified, with 12 meeting the inclusion criteria. Ten studies included asthma patients, 1 study included COPD patients and 1 study included both asthma and COPD. A total of 1104 participants were included, of whom 941 were asthmatic, 64 had COPD and 109 were healthy controls. Studies were heterogeneous in design including the device, dose and time intervals for BDR assessment. A small airway BDR was seen for most tests in asthma and COPD, including oscillometry (R5-20, reactance (X5), area of reactance (AX) and resonant frequency (Fres)) and Maximal Mid Expiratory Flow.
CONCLUSION
There is a measurable BDR in the small airways. However, with no consensus on how to assess BDR, studies were heterogeneous. Further research is needed to inform how BDR should be assessed, its clinical impact and place in routine clinical practice.
Topics: Adult; Asthma; Bronchodilator Agents; Cross-Sectional Studies; Forced Expiratory Volume; Humans; Pulmonary Disease, Chronic Obstructive; Spirometry
PubMed: 34795479
DOI: 10.2147/COPD.S331995 -
BMJ Open Respiratory Research Dec 2020Asthma is a common, heterogeneous disease that is characterised by chronic airway inflammation and variable expiratory airflow limitation. Current guidelines use...
BACKGROUND
Asthma is a common, heterogeneous disease that is characterised by chronic airway inflammation and variable expiratory airflow limitation. Current guidelines use spirometric measures for asthma assessment. This systematic review aimed to assess whether the most commonly reported tests of small airways function could contribute to the diagnosis of asthma.
METHODS
Standard systematic review methodology was used, and a range of electronic databases was searched (Embase, MEDLINE, CINAHL, CENTRAL, Web of Science, DARE). Studies that included physiological tests of small airways function to diagnose asthma in adults were included, with no restrictions on language or date. The risk of bias and quality assessment tools used were Agency for Healthcare Research and Quality tool for cross-sectional studies and Quality Assessment of Diagnostic Accuracy Studies 2 for diagnostic test accuracy (DTA) studies.
RESULTS
7072 studies were identified and 10 studies met review criteria. 7 included oscillation techniques and 5 included maximal mid-expiratory flow (MMEF). Studies were small and of variable quality. In oscillometry, total resistance (R5) and reactance at 5 Hz (X5) was altered in asthma compared with healthy controls. The percentage predicted of MMEF was lower in patients with asthma compared with controls in all studies and lower than the % predicted forced expiratory volume in 1 s. In DTA of oscillometry, R5 showed a sensitivity between 69% and 72% and specificity between 61% and 86%.
CONCLUSION
There were differences in the results of physiological tests of small airway function in patients with asthma compared with controls. However, studies are small and heterogeneous. Further studies are needed to assess the effectiveness of these tests on a larger scale, including studies to determine which test methodology is the most useful in asthma.
Topics: Adult; Asthma; Cross-Sectional Studies; Diagnostic Tests, Routine; Forced Expiratory Volume; Humans; Spirometry; United States
PubMed: 33371011
DOI: 10.1136/bmjresp-2020-000770 -
Pediatric Pulmonology Jul 2021Several studies have explored the predictive value of impulse oscillometry (IOS) for asthma exacerbations in childhood, but its specific parameters are still unclear.... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Several studies have explored the predictive value of impulse oscillometry (IOS) for asthma exacerbations in childhood, but its specific parameters are still unclear. Therefore, we designed this meta-analysis to determine the related indicators of acute asthma attacks.
METHODS
A comprehensive literature search was performed on July 9, 2020 based on PubMed, Embase, and Web of Science database. Weighted mean differences (WMDs) were calculated using fixed- or random-effects models.
RESULTS
A total of 615 patients from six trials were included in this analysis. IOS may be a useful tool to predict asthma exacerbations. And the results showed that R5 (WMD = -1.21, 95% CI: -1.55 to -0.87, p < .001), Fres (WMD = -1.34, 95% CI: -2.03 to -0.65, p = .018), and AX (WMD = -7.35, 95% CI: -9.94 to -4.76, p < .001) had significant correlation with asthma exacerbations. In addition, X5 may also predict the acute attack of asthma (WMD = 0.81, 95% CI: 0.56 to 1.01, p < .001).
CONCLUSIONS
R5, AX, Fres, and X5 may be able to identify the risk of an acute attack of asthma. Besides, our research further demonstrated that peripheral airway injury may play an important role in the acute attack of asthma.
Topics: Asthma; Databases, Factual; Humans; Oscillometry; Respiratory Function Tests; Retrospective Studies; Spirometry
PubMed: 33756052
DOI: 10.1002/ppul.25374