Brazilian Journal of Otorhinolaryngology 2022To present scientific evidence, based on a systematic review of the literature, on the benefit of brainstem implants in auditory rehabilitation and language development... (Review)
Review
OBJECTIVE
To present scientific evidence, based on a systematic review of the literature, on the benefit of brainstem implants in auditory rehabilitation and language development in children.
METHODS
A systematic search was used to identify studies that contain information about the benefit of brainstem implants in the auditory rehabilitation and language development of children. The review was conducted based on a structured literature search, following the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) checklist. The search was carried out in the PubMed, Web of Science and Scopus databases, using the combination "Auditory brainstem implants" AND "Pediatric", without restriction of language, period, and location. The quality assessment of the articles was performed using the Study Quality Assessment Tools.
RESULTS
Regarding hearing, children with brainstem implants showed sound detection, access to most speech sounds, basic auditory perception skills, recognition of ambient sounds, recognition of some frequently used words and phrases, in addition to some closed-set word discrimination capability. Expressive and comprehensive language were identified in children using auditory brainstem implants, increasing significantly in the short and long terms in most cases; however, in some of the children, such skills remained stable.
CONCLUSION
The auditory brainstem implant can be considered an effective alternative for children with cochlear malformation and/or auditory nerve deficiency and for those who cannot benefit from cochlear implant surgery.
Topics: Child; Humans; Deafness; Auditory Brain Stem Implants; Cochlear Implantation; Language Development; Cochlear Implants; Hearing; Brain Stem; Speech Perception
PubMed: 36088255
DOI: 10.1016/j.bjorl.2022.07.004 -
BMC Urology Mar 2021Infection is the most feared complication of a penile prosthesis. Diabetes mellitus (DM) is widely known to increase the risk of several infections, but its role in the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Infection is the most feared complication of a penile prosthesis. Diabetes mellitus (DM) is widely known to increase the risk of several infections, but its role in the penile prosthesis is still controversial. This systematic review aims to show the contemporary scenario of penile prosthesis infection and present a meta-analysis about DM contribution to penile prosthesis infection.
METHODS
The review was performed with no language or time limitation, including ten databases. The included articles were about the male population who received a penile prosthesis with no model restriction, with a minimum follow up of 1 year, and outcomes adequately reported.
RESULTS
The mean infection incidence of penile prosthesis ranged from 0.33 to 11.4%. In early 2000, the general incidence of infection was 3 to 5%, then, the introduction of coated materials decreased it to 0.3 to 2.7%. The meta-analysis showed that diabetes mellitus is related to an increased risk of penile prosthesis infection with an odds ratio of 1.53 (95% CI 1.15-2.04).
CONCLUSIONS
Penile prosthesis infection decreased in the last decades but remains a significant cause of reoperation, and it is related to lower prosthesis survival. Meta-analysis concludes that diabetes mellitus is related to a higher risk of penile prosthesis infection.
Topics: Diabetes Complications; Humans; Male; Penile Prosthesis; Prosthesis-Related Infections
PubMed: 33691670
DOI: 10.1186/s12894-020-00730-2 -
Medicine Mar 2023Lisfranc and Chopart amputations are historically controversial procedures. To obtain evidence for the pros and cons we performed a systematic review to analyze wound...
BACKGROUND
Lisfranc and Chopart amputations are historically controversial procedures. To obtain evidence for the pros and cons we performed a systematic review to analyze wound healing, the need for re-amputation at a higher level, and ambulation after a Lisfranc or Chopart amputation.
METHODS
A literature search was performed in 4 databases (Cochrane, Embase, Medline, and PsycInfo), using database-specific search strategies. Reference lists were studied to include relevant studies that were missed in the search. Of the 2881 publications found, 16 studies could be included in this review. Excluded publications concerned editorials, reviews, letters to the editor, no full text available, case reports, not meeting the topic, and written in a language other than English, German, or Dutch.
RESULTS
Failed wound healing occurred in 20% after Lisfranc amputation, in 28% after modified Chopart amputation, and 46% after conventional Chopart amputation. After Lisfranc amputation, 85% of patients were able to ambulate without prosthesis for short distances, and after modified Chopart 74%. After a conventional Chopart amputation, 26% (10/38) had unlimited household ambulation.
CONCLUSIONS
The need for re-amputation because wound healing problems occurred most frequently after conventional Chopart amputation. All 3 types of amputation levels do, however, provide a functional residual limb, with the remaining ability to ambulate without prosthesis for short distances. Lisfranc and modified Chopart amputations should be considered before proceeding to a more proximal level of amputation. Further studies are needed to identify patient characteristics to predict favorable outcomes of Lisfranc and Chopart amputations.
Topics: Humans; Foot; Amputation, Surgical; Diabetic Foot; Walking; Artificial Limbs
PubMed: 36897730
DOI: 10.1097/MD.0000000000033188 -
Current Cardiology Reviews 2022Paravalvular Leak (PVL) refers to the retrograde flow of blood in the space between an implanted cardiac valve and native tissue. These are unfortunately but luckily...
BACKGROUND
Paravalvular Leak (PVL) refers to the retrograde flow of blood in the space between an implanted cardiac valve and native tissue. These are unfortunately but luckily relatively uncommon complications of prosthetic valve replacement that, especially when moderate or severe, have important clinical consequences.
OBJECTIVE
Addressing PVL requires a multidisciplinary team to properly diagnose this process and choose the corrective option most likely to result in success.
METHODS
A comprehensive literature search was undertaken to formulate this narrative review.
RESULTS
This review highlights the complex nature of PVL and the promising contemporary treatments available.
CONCLUSION
Clinicians should be adept at recognizing PVL and characterizing it using multimodality imaging. Using the many available tools and a multidisciplinary approach should lead to favorable outcomes in patients with PVL.
Topics: Humans; Aortic Valve; Aortic Valve Insufficiency; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Retrospective Studies; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 35546743
DOI: 10.2174/1573403X18666220511113310 -
Minerva Urology and Nephrology Dec 2023Inflatable penile prosthesis are the definitive treatment for erectile dysfunction. The two most used surgical approaches to position the implants are the penoscrotal... (Review)
Review
INTRODUCTION
Inflatable penile prosthesis are the definitive treatment for erectile dysfunction. The two most used surgical approaches to position the implants are the penoscrotal and the infrapubic. Current trends showed that the penoscrotal approach is extensively preferred however, there is not conclusive evidence demonstrating the superiority of one technique over the other. The aim of this review is to summarize the scientific evidence available and to underline strengths and weaknesses of the two techniques.
EVIDENCE ACQUISITION
We conducted a comprehensive search of MEDLINE, Cochrane Library, and National Center for Biotechnology Information PubMed to identify relevant published articles. The included studies had to explicitly examine the use of three-piece inflatable penile prosthesis with a focus on the surgical access method and complications.
EVIDENCE SYNTHESIS
Twenty-six articles were included in the review: seven narrative reviews, five retrospective observational studies, five prospective observational studies, and nine mixed methodology studies. The most frequent approach was the penoscrotal, which was also found more comfortable (RG1) by the operators in one study. The infrapubic approach lasts less and one study demonstrated higher satisfaction by the patients.
CONCLUSIONS
There is no evidence of significant differences in complications among the penoscrotal and infrapubic approaches. While the infrapubic approach is faster and patients were more satisfied, the penoscrotal approach is the most used by far. This is likely related to the more straightforward procedure through this access and the excellent surgical field exposure. For these reasons, it is also preferred in the most complex cases.
Topics: Humans; Male; Observational Studies as Topic; Patient Satisfaction; Penile Implantation; Penile Prosthesis; Penis; Retrospective Studies
PubMed: 38126284
DOI: 10.23736/S2724-6051.23.05475-7 -
Journal of Cardiothoracic Surgery Apr 2023Post-pneumonectomy syndrome (PPS) is rare and predominantly characterised by dynamic airway obstruction due to mediastinal rotation at any time point following... (Review)
Review
OBJECTIVES
Post-pneumonectomy syndrome (PPS) is rare and predominantly characterised by dynamic airway obstruction due to mediastinal rotation at any time point following pneumonectomy. The objective of this systematic review was to identify the optimal treatment strategy for PPS based on subjective symptomatic relief, objective radiological imaging, and treatment durability.
METHODS
A systematic review was performed up to and including February 2022 based on the "Preferred Reporting Items for Systematic Reviews and Meta-Analyses" guidelines. All studies that presented the management of symptomatic patients > 16 years of age with radiologically confirmed PPS were included. The primary outcome was the identification of the optimal treatment strategy and the secondary outcome was durability of the treatment. The Oxford Centre for Evidence Based Medicine level was assigned to each study.
RESULTS
A total of 330 papers were identified and reviewed; 41 studies met the inclusion criteria. Data including patient demographics, indication for initial pneumonectomy, presenting symptoms, management approach, outcomes, and follow-up were assessed and analysed. Management approaches were divided into three categories: (a) mediastinal repositioning using implant prostheses; (b) endobronchial stenting; (c) other corrective procedures. One hundred and four patients were identified in total and of those, 87 underwent mediastinal repositioning with insertion of a prosthetic implant. Complications included over- or under-filling of the prosthesis (8.5%) and implant leakage (8.9%).
CONCLUSION
Management of PPS using a prosthetic implant to reposition the mediastinum is the treatment of choice. Key adjuncts to optimise surgical approach and minimise complications include pre-operative CT volumetric analysis to guide implant size and intra-operative transoesophageal echocardiography to guide mediastinal repositioning.
Topics: Humans; Pneumonectomy; Mediastinum; Thorax; Prostheses and Implants; Prosthesis Implantation; Syndrome
PubMed: 37038182
DOI: 10.1186/s13019-023-02278-2 -
Evidence-based Dentistry Sep 2023A systematic appraisal and statistical aggregation of primary studies in humans. (Meta-Analysis)
Meta-Analysis
DESIGN
A systematic appraisal and statistical aggregation of primary studies in humans.
DATA SOURCES
The researchers utilized PubMed (Medline) and Scopus databases as the primary data sources for this study. They performed a comprehensive literature search based on free keywords and Medical Subject Heading (MeSH) terms to enhance the search accuracy. The database search was concluded on November 13, 2022. Furthermore, a meticulous examination of the references cited in the selected studies was conducted to identify additional relevant articles that could be incorporated into the analysis.
STUDY SELECTION
The systematic review focused on partially or fully edentulous patients receiving dental implants and aimed to determine if the lack of keratinized mucosa at the implant site increased the risk of peri-implantitis compared to patients with adequate keratinized mucosa. Human studies with a minimum of 100 implants, cross-sectional, cohort, or case-control designs, and a follow-up period of at least one year were included. Studies lacking a clear case definition or information on peri-implantitis and those that did not investigate keratinized mucosa as a risk indicator were excluded.
DATA EXTRACTION AND SYNTHESIS
Two reviewers independently utilized a systematic review screening website (Rayyan, Qatar Computing Research Institute, Qatar Foundation) to select potential articles, and conflicts were resolved through discussion or consultation with a third reviewer. The data extraction process involved recording information from the included articles, such as study design, patient and implant numbers, prosthesis type (fixed or removable), follow-up duration, peri-implantitis case definition, prevalence at patient and implant levels, keratinized mucosa cutoff value, odds ratio (OR) of peri-implantitis considering keratinized mucosa, and conclusions on the potential effect of keratinized mucosa from each study. The Newcastle Ottawa scale (NOS) and a modified version of NOS were used, respectively, to assess the quality of cohort and cross-sectional studies. Studies scoring below 6 out of 9 points were classified as low quality. For the meta-analysis, the relationship between peri-implantitis and keratinized mucosa was evaluated using the odds ratio (OR) and standard error (SE). Heterogeneity was assessed through the Chi test and I index, determining whether a random-effects or fixed-effects model should be applied. Subgroup and cluster analyses were conducted based on specific criteria, and forest plots and funnel plots were generated to visualize results and identify potential study bias. Sensitivity analysis was performed to verify the robustness of the meta-analysis, with statistical significance set at p < 0.05. The Review Manager (RevMan) software facilitated data analysis. The GRADE rating system was used to determine the level of evidence, considering factors such as bias risk, imprecision, inconsistency, indirectness, and publication bias. The certainty of the evidence was evaluated based on the overall outcomes of analyzed subgroups.
RESULTS
Twenty-two primary studies were identified, and a meta-analysis was conducted on 16 cross-sectional studies. The prevalence of peri-implantitis ranged from 6.68% to 62.3% at the patient level and from 4.5% to 58.1% at the implant level. The overall analysis revealed a significant association between the lack of keratinized mucosa and a higher prevalence of peri-implantitis (OR = 2.78, 95% CI 2.07-3.74, p < 0.00001). Subgroup analyses with a consistent case definition of peri-implantitis (MBL ≥ 2 mm) showed similar results (OR = 1.96, 95% CI 1.41-2.73, p < 0.0001). Studies focusing on fixed prostheses only demonstrated that the lack of keratinized mucosa was associated with an increased prevalence of peri-implantitis (OR = 2.82, 95% CI 1.85-4.28, p < 0.00001). Among patients under regular implant maintenance, the absence of keratinized mucosa significantly raised the occurrence of peri-implantitis (OR = 2.08, 95% CI 1.41-3.08, p = 0.0002). Studies adjusting for other variables also confirmed a higher risk of peri-implantitis with inadequate keratinized mucosa (OR = 3.68, 95% CI 2.32-5.82, p = 0.007). Although some publication bias was observed, the certainty of evidence based on the GRADE system was judged to be "moderate."
CONCLUSIONS
The lack of keratinized mucosa increased the risk of peri-implantitis, emphasizing the need to consider it during dental implant placement. Inadequate data on patient-specific factors and the predominance of cross-sectional studies influenced the evidence quality (i.e., moderate). Future studies with consistent methodologies shall confirm these findings and identify additional risk indicators to improve implant dentistry practices.
Topics: Humans; Peri-Implantitis; Dental Implants; Cross-Sectional Studies; Mucous Membrane; Risk Factors
PubMed: 37537217
DOI: 10.1038/s41432-023-00913-4 -
Journal of Shoulder and Elbow Surgery May 2022The use of reverse total shoulder arthroplasty and stemless anatomic total shoulder replacement has been increasing in the United States every year. Stemless humeral... (Review)
Review
BACKGROUND
The use of reverse total shoulder arthroplasty and stemless anatomic total shoulder replacement has been increasing in the United States every year. Stemless humeral components in reverse total shoulder arthroplasty are only approved for clinical trials in the United States with an investigational device exception with limited data.
METHODS
A systematic review on stemless reverse total shoulder arthroplasty was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. A search was conducted on November 25, 2020, using the MEDLINE/PubMed, Cochrane, and Embase databases. All articles were reviewed by 2 independent evaluators, with any conflicts or issues resolved by consensus or a final decision by the senior author. The primary outcomes extracted were complications, radiographic results, and outcome scores.
RESULTS
We evaluated 10 studies that used either the Total Evolutive Shoulder System (TESS) or Verso implant. There were 430 total patients and 437 total procedures; 266 patients in the TESS group underwent a total of 272 procedures, and 164 patients in the Verso group underwent a total of 165 procedures. The mean age at the time of surgery was 73.8 years (range, 38-93 years). The mean follow-up period ranged from 6.4 to 101.6 months per study. There was an overall trend of improved clinical outcome scores, a 0.2% humeral component loosening rate, and an 11.2% complication rate.
CONCLUSIONS
This review shows that the clinical and functional outcomes following stemless or metaphyseal reverse total shoulder arthroplasty are quite promising, especially with the low rate of humeral-sided complications. There continues to be a need for additional long-term studies and randomized clinical trials.
Topics: Arthroplasty, Replacement, Shoulder; Humans; Prosthesis Design; Shoulder Joint; Shoulder Prosthesis; Treatment Outcome
PubMed: 35051541
DOI: 10.1016/j.jse.2021.12.017 -
Nigerian Journal of Clinical Practice Sep 2023Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients.... (Review)
Review
Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients. Recently, immediate loading of implants has gained much importance as it helps hasten the procedure and provides more comfort to patients. A previous systematic review published 5 years ago compared the success rates between immediate and conventional loading. There are several factors that influence the success rate of implants that were not discussed in detail in the previous review. Hence, the present systematic review is done to report differences in the outcomes from single implant restorations of missing teeth in the posterior region in patients who were subjected to immediate loading and conventional loading. A follow up for 1 year was done. Electronic databases of Medline, Scopus, and Web of Science were searched for publications in the English Language during May 2021. The search results yielded 306 articles, out of which 225 were excluded based on title and abstract screening. Screening of the remaining 81 full text articles yielded 14 original research articles that satisfied the predefined inclusion criteria. Meta analysis was not possible due to the heterogeneity of the data. The overall success rate of the immediate loading of a single implant is 94.31%. Implants in the maxillary region had a higher survival rate than those in the mandibular region. The age range between 18 and 80 years showed good prognosis and outcomes in older individuals. Good oral hygiene was emphasized for all patients to prevent any secondary conditions or delays in healing.
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Humans; Middle Aged; Young Adult; Anodontia; Dental Implants; Dental Prosthesis, Implant-Supported; Immediate Dental Implant Loading; Tooth Loss
PubMed: 37794532
DOI: 10.4103/njcp.njcp_884_22 -
Journal of Orthopaedic Surgery and... Dec 2023Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extended reality (XR), including virtual reality, augmented reality (AR), and mixed reality, has been used to help achieve accurate acetabular cup placement in total hip arthroplasty (THA). This study aimed to compare the differences between XR-assisted and conventional THA.
METHODS
In this systematic review and meta-analysis, electronic databases including PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials (CENTRAL), and clinicaltrials.gov were searched for studies from inception to September 10, 2023. The outcomes were accuracy of inclination and anteversion, duration of surgery, and intraoperative blood loss. Meta-analysis was performed using Review Manager 5.4 software.
RESULTS
A total of five studies with 396 patients were included in our study. The pooled results indicated AR-assisted THA had better accuracy of inclination and anteversion than conventional THA (SMD = - 0.51, 95% CI [- 0.96 to - 0.07], P = 0.02; SMD = - 0.96, 95% CI [- 1.19 to - 0.72], P < 0.00001), but duration of surgery and intraoperative blood loss were similar in the two groups.
CONCLUSION
This systematic review and meta-analysis found that AR-assisted THA had better accuracy of inclination and anteversion than conventional THA, but the duration of surgery and intraoperative blood loss were similar in the two groups. Based on the pooled results, we suggested that AR can provide more precise acetabular cup placement than conventional methods in THA.
Topics: Humans; Arthroplasty, Replacement, Hip; Augmented Reality; Blood Loss, Surgical; Acetabulum; Surgery, Computer-Assisted; Hip Prosthesis
PubMed: 38042852
DOI: 10.1186/s13018-023-04421-0