-
Ecological Applications : a Publication... Mar 2020As a consequence of the global ubiquity of plastic pollution, scientists, decision-makers, and the public often ask whether macroplastics (>5 mm) and microplastics... (Meta-Analysis)
Meta-Analysis
As a consequence of the global ubiquity of plastic pollution, scientists, decision-makers, and the public often ask whether macroplastics (>5 mm) and microplastics (<5 mm) have a realized ecological threat. In 2016, we conducted a systematic review of the literature and made a call for further research testing hypotheses about ecological effects. In the subsequent years, the amount of relevant research has risen tremendously. Here, we reassess the literature to determine the current weight of evidence about the effects of plastic pollution across all levels of biological organization. Our data spans marine, freshwater, and terrestrial environments. We extracted data from 139 lab and field studies testing 577 independent effects across a variety of taxa and with various types, sizes, and shapes of plastic. Overall, 59% of the tested effects were detected. Of these, 58% were due to microplastics and 42% were due to macroplastics. Of the effects that were not detected, 94% were from microplastics and 6% were from macroplastics. We found evidence that whether or not an effect is detected, as well as the severity and direction of the effect, is driven by dose, particle shape, polymer type, and particle size. Based on our analyses, there is no doubt that macroplastics are causing ecological effects, however, the effects of microplastics are much more complex. We also assessed the environmental relevancy of experimental studies by comparing the doses used in each exposure to the concentrations and sizes of microplastics found in the environment. We determined that only 17% of the concentrations used in experimental studies have been found in nature, and that 80% of particle sizes used in experiments fall below the size range of the majority of environmental sampling. Based on our systematic review and meta-analysis, we make a call for future work that recognizes the complexity of microplastics and designs tests to better understand how different types, sizes, shapes, doses, and exposure durations affect wildlife. We also call for more ecologically and environmentally relevant studies, particularly in freshwater and terrestrial environments.
Topics: Environmental Monitoring; Environmental Pollution; Fresh Water; Microplastics; Plastics; Water Pollutants, Chemical
PubMed: 31758826
DOI: 10.1002/eap.2044 -
Journal of Back and Musculoskeletal... 2023Marathon running is an extreme sport with a distance of about 42 kilometers. Its relationship to high-sensitivity cardiac troponin (hs-cTn) remains controversial. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Marathon running is an extreme sport with a distance of about 42 kilometers. Its relationship to high-sensitivity cardiac troponin (hs-cTn) remains controversial.
OBJECTIVE
As the gold standard for detecting myocardial injury, the trends of hs-cTn before and after a marathon were investigated and analyzed.
METHODS
A literature search was conducted in PubMed, EMBASE, and Cochrane Library databases by combing the keywords marathon and troponin, and studies regarding high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT) concentrations before and after marathon running (not for half-marathon and ultra-marathon) were included. "Quality Assessment Tool for Before-After (Pre-Post) Studies With No Control Group" were used to assess the risk of bias. Statistical analysis was performed using Review Manager, presenting data as mean values and 95% confidence intervals (CIs). Sensitivity analysis and subgroup analysis were performed if there was high heterogeneity among studies based on I2 statistic.
RESULTS
A total of 13 studies involving 824 marathoners were included in this systematic review and meta-analysis. Both hs-cTnI (MD 68.79 ng/L, [95% CI 53.22, 84.37], p< 0.001) and hs-cTnT (MD 42.91 ng/L, [95% CI 30.39, 55.43], p< 0.001) were elevated after running a marathon, but the concentration of hs-cTnT returned to baseline after 72 to 96 h post-race (MD 0.11 ng/L, [95% CI -1.30, 1.52], p= 0.88). The results of subgroup analysis demonstrated that the 99th percentile upper reference limit of hs-cTnT might be the source of heterogeneity.
CONCLUSION
The concentrations of hs-cTnI and hs-cTnT were increased after marathon running, but the change of hs-cTnT is usually not seen as irreversible myocardial injury.
Topics: Humans; Marathon Running; Troponin I; Troponin T; Male; Adult; Middle Aged
PubMed: 37248881
DOI: 10.3233/BMR-220352 -
The Journal of Oral Implantology Dec 2016Polyetheretherketone (PEEK) has been suggested as an alternative to replace titanium as a dental implant material. However, PEEK's bioactivity and osseointegration are... (Comparative Study)
Comparative Study Review
Polyetheretherketone (PEEK) has been suggested as an alternative to replace titanium as a dental implant material. However, PEEK's bioactivity and osseointegration are debatable. This review has systematically analyzed studies that have compared PEEK (or PEEK-based) implants with titanium implants so that its feasibility as a possible replacement for titanium can be determined. The focused question was: "Are the bioactivity and osseointegration of PEEK implants comparable to or better than titanium implants?" Using the key words "dental implant," "implant," "polyetheretherketone," "PEEK," and "titanium" in various combinations, the following databases were searched electronically: PubMED/MEDLINE, Embase, Google Scholar, ISI Web of Knowledge, and Cochrane Database. 5 in vitro and 4 animal studies were included in the review. In 4 out of 5 in vitro studies, titanium exhibited more cellular proliferation, angiogenesis, osteoblast maturation, and osteogenesis compared to PEEK; one in vitro study observed comparable outcomes regardless of the implant material. In all animal studies, uncoated and coated titanium exhibited a more osteogenic behavior than did uncoated PEEK, while comparable bone-implant contact was observed in HA-coated PEEK and coated titanium implants. Unmodified PEEK is less osseoconductive and bioactive than titanium. Furthermore, the majority of studies had multiple sources of bias; hence, in its unmodified form, PEEK is unsuitable to be used as dental implant. Significantly more research and long-term trials must focus on improving the bioactivity of PEEK before it can be used as dental implant. More comparative animal and clinical studies are warranted to ascertain the potential of PEEK as a viable alternative to titanium.
Topics: Animals; Benzophenones; Dental Implants; Ketones; Osseointegration; Polyethylene Glycols; Polymers; Titanium
PubMed: 27560166
DOI: 10.1563/aaid-joi-D-16-00072 -
Chemosphere Sep 2022Single-use plastics (SUPs) have become an essential constituent of our daily life. It is being exploited in numerous pharmaceutical and healthcare applications. Despite... (Review)
Review
Single-use plastics (SUPs) have become an essential constituent of our daily life. It is being exploited in numerous pharmaceutical and healthcare applications. Despite their advantages and widespread use in the pharma and medical sectors, the potential clinical problems of plastics, especially the release of micro-nanoplastics (MNPs) and additives from medical plastics (e.g. bags, containers, and administrative sets) and sorption of drugs remain understudied. Certainly, the MNPs are multifaceted stressors that cause detrimental effects to the ecosystem and human health. The origin and persistence of MNPs in pharmaceutical products, their administration to humans, endurance and possible health implication, translocation, and excretion have not been reviewed in detail. The prime focus of this article is to conduct a systematic review on the leaching of MNPs and additives from pharmaceutical containers/administrative sets and their interaction with the pharmaceutical constituents. This review also explores the primary and secondary routes of MNPs entry from healthcare plastic products and their potential health hazards to humans. Furthermore, the fate of plastic waste generated in hospitals, their disposal, and associated MNPs release to the environment, along with preventive, and alternative measures are discussed herein.
Topics: Ecosystem; Humans; Pharmaceutical Preparations; Plastics; Water Pollutants, Chemical
PubMed: 35671817
DOI: 10.1016/j.chemosphere.2022.135227 -
Journal of the World Federation of... Dec 2021The study evaluated and compared the force decay of orthodontic elastomeric chains/modules in both in vivo and in vitro settings. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The study evaluated and compared the force decay of orthodontic elastomeric chains/modules in both in vivo and in vitro settings.
METHODS
A protocol in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was formulated and registered with the International Prospective Register of Systematic Reviews. A total of 53 articles (44 in vitro and 9 in vivo studies) found via search of the electronic databases of Cochrane and the National Library of Medicine (MEDLINE; PubMed), and manual search of the gray literature from institutional library resources, were selected. Data extraction, quality analysis, risk of bias assessment, and meta-analysis of the level of force decay of elastomeric chains/modules were conducted per standard protocol, and suitable statistical analyses were applied.
RESULTS
The mean force decay in the in vivo setting was 41.9% at 24 hours, 42.6% after 1 week, 46.8% after 2 weeks, and 55.0% after 3 weeks. Similarly, the force decay in the in vitro studies was 38.9% at 24 hours, 42.1% after 1 week, 44.6% after 2 weeks, and 51.1% after 3 weeks. However, at the 95% confidence interval, the force decay rates of in vivo and in vitro studies overlap, with a statistically insignificant difference in force decay observed in the in vivo and in vitro settings.
CONCLUSIONS
This systematic review and meta-analysis observed more force decay in the in vivo studies versus the in vitro studies (although this difference was statistically insignificant), with the maximum force decay occurring during the initial days, with a reduction to approximately 50% within 3 weeks. Hence, change of the elastomeric chains/module, at intervals of 3 weeks, is advised. (PROSPERO registration no. CRD42020209535).
Topics: Elasticity; Elastomers; Mechanical Phenomena; Orthodontic Appliances; United States
PubMed: 34364839
DOI: 10.1016/j.ejwf.2021.07.003 -
Operative Dentistry Jul 2023To evaluate the adhesion of universal adhesive systems to the dentin of noncarious cervical lesions (NCCLs) by comparing the etch-and-rinse and self-etch strategies... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To evaluate the adhesion of universal adhesive systems to the dentin of noncarious cervical lesions (NCCLs) by comparing the etch-and-rinse and self-etch strategies through a systematic review and meta-analysis.
METHODS
Systematic electronic searches were performed by two independent reviewers into the following databases: PubMed/MEDLINE, Scopus, Web of Science, and Cochrane Library until December of 2021. Only randomized clinical trials were selected, comparing etch-and-rinse and self-etch strategies and using universal adhesive systems in NCCLs. This systematic review was conducted according to the PRISMA guidelines and registered into PROSPERO.
RESULTS
After the removal of duplicates, 170 articles were identified. In an initial screening of titles and abstracts, 146 records did not satisfy the inclusion criteria and were, therefore, excluded. Twenty-four studies were eligible for evaluation of the full text, and four were excluded after this step. Finally, 20 randomized clinical trials were included in this systematic review and meta-analysis.
CONCLUSION
This systematic review and meta-analysis revealed that applying universal adhesive systems in the etch-and-rinse strategy could lead to better medium-term (>12 to 36 months) retention of NCCL restorations than the self-etch strategy, as well as resulting in lower percentages of marginal discoloration, marginal adaptation, and secondary caries. However, the use of a self-etching strategy can lead to lower postoperative sensitivity.
Topics: Humans; Dental Cements; Dentin-Bonding Agents; Resin Cements; Composite Resins; Tooth Cervix; Dental Restoration, Permanent; Dental Marginal Adaptation
PubMed: 37352462
DOI: 10.2341/22-067-LIT -
Lancet (London, England) Jan 2014Formation of adhesions after peritoneal surgery results in high morbidity. Barriers to prevent adhesion are seldom applied, despite their ability to reduce the severity... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Formation of adhesions after peritoneal surgery results in high morbidity. Barriers to prevent adhesion are seldom applied, despite their ability to reduce the severity of adhesion formation. We evaluated the benefits and harms of four adhesion barriers that have been approved for clinical use.
METHODS
In this systematic review and meta-analysis, we searched PubMed, CENTRAL, and Embase for randomised clinical trials assessing use of oxidised regenerated cellulose, hyaluronate carboxymethylcellulose, icodextrin, or polyethylene glycol in abdominal surgery. Two researchers independently identified reports and extracted data. We compared use of a barrier with no barrier for nine predefined outcomes, graded for clinical relevance. The primary outcome was reoperation for adhesive small bowel obstruction. We assessed systematic error, random error, and design error with the error matrix approach. This study is registered with PROSPERO, number CRD42012003321.
FINDINGS
Our search returned 1840 results, from which 28 trials (5191 patients) were included in our meta-analysis. The risks of systematic and random errors were low. No trials reported data for the effect of oxidised regenerated cellulose or polyethylene glycol on reoperations for adhesive small bowel obstruction. Oxidised regenerated cellulose reduced the incidence of adhesions (relative risk [RR] 0·51, 95% CI 0·31-0·86). Some evidence suggests that hyaluronate carboxymethylcellulose reduces the incidence of reoperations for adhesive small bowel obstruction (RR 0·49, 95% CI 0·28-0·88). For icodextrin, reoperation for adhesive small bowel obstruction did not differ significantly between groups (RR 0·33, 95% CI 0·03-3·11). No barriers were associated with an increase in serious adverse events.
INTERPRETATION
Oxidised regenerated cellulose and hyaluronate carboxymethylcellulose can safely reduce clinically relevant consequences of adhesions.
FUNDING
None.
Topics: Abdomen; Carboxymethylcellulose Sodium; Cellulose, Oxidized; Glucans; Glucose; Humans; Icodextrin; Polyethylene Glycols; Postoperative Complications; Randomized Controlled Trials as Topic; Tissue Adhesions; Treatment Outcome
PubMed: 24075279
DOI: 10.1016/S0140-6736(13)61687-6 -
Journal of Orthopaedic Research :... Mar 2022Currently, steel implants are used for osteosynthesis of (comminuted) fractures and intra-articular bone defects. These osteosyntheses can sometimes be complicated... (Meta-Analysis)
Meta-Analysis
Currently, steel implants are used for osteosynthesis of (comminuted) fractures and intra-articular bone defects. These osteosyntheses can sometimes be complicated procedures and can have several drawbacks including stress shielding of the bone. A bone glue might be a safe and effective alternative to current materials. Despite numerous animal studies on bone adhesives, no such material is clinically applied yet. We have conducted a systematic review to summarize the evidence in experimental animal models used in research on bone adhesive materials for trauma and orthopedic surgery. Additionally, we analysed the efficacy of the different bone adhesives for different experimental designs. A heterogeneity in experimental parameters including animal species, defect types, and control measurements resulted in a wide variety in experimental models. In addition, no standard outcome measurements could be identified. Meta-analysis on bone regeneration between adhesive treatment and nonadhesive treatment showed a high heterogeneity and no statistically significant overall effect (M: -0.71, 95% confidence interval [CI]: -1.63-0.21, p = 0.13). Besides, currently there is not enough evidence to draw conclusions based on the effectiveness of the individual types of adhesives or experimental models. A positive statistically significant effect was found for the adhesive treatment in comparison with conventional osteosynthesis materials (M: 2.49, 95% CI: 1.20-3.79, p = 0.0002). To enhance progression in bone adhesive research and provide valuable evidence for clinical application, more standard experimental parameters and a higher reporting quality in animal studies are needed. Statement of Clinical Significance: Current materials restoring anatomical alignments of bones have several drawbacks. A (biodegradable) adhesive for fixating bone defects can be a treatment breakthrough. Although numerous bone adhesives have been researched, most seemed to fail at the preclinical stage. An overview in this field is missing. This systematic review highlights the relevant parameters for design of experimental bone adhesive studies. It demonstrates evidence regarding benefit of bone adhesives but also that the quality of reporting and the risk of bias in studies need to be improved. The results will aid in designing better quality animal studies for bone adhesive research with higher translational value.
Topics: Adhesives; Animals; Bone Cements; Bone and Bones; Models, Animal; Orthopedic Procedures
PubMed: 33871061
DOI: 10.1002/jor.25057 -
European Journal of Clinical... Mar 2020Inulin, consisting of repetitive fructosyl units linked by β(2,1) bonds, is a readily fermentable fiber by intestinal bacteria that generates large quantities of... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Inulin, consisting of repetitive fructosyl units linked by β(2,1) bonds, is a readily fermentable fiber by intestinal bacteria that generates large quantities of short-chain fatty acids (SCFA). In individuals with constipation, it was reported that inulin ingestion was associated with a significant increase in stool frequency, suggesting a potential impact of inulin on human gut microbiota composition. Progress in high-throughput technologies allow assessment of human-associated microbiomes in terms of diversity and taxonomic or functional composition, and can identify changes in response to a specific supplementation. Hence, to understand the effects of inulin on the human gut microbiome is pivotal to gain insight into their mechanisms of action.
METHODS
Here, we conducted a systematic review of human studies in adult individuals showing the effects of inulin on the gut microbiome. We searched in MEDLINE, EMBASE, Web of Science, and Scopus databases for articles in English published in peer-reviewed journals and indexed up until March 2019. We used multiple search terms capturing gut microbiome, gut microflora, intestinal microbiota, intestinal flora, gut microbiota, gut flora, microbial gut community, gut microbial composition, and inulin.
RESULTS
Overall, nine original articles reported the effects of inulin on microbiome composition in adult humans, most of them being randomized, double-blind, placebo-controlled trials (n = 7). Studies varied significantly in design (3 studies associated inulin and oligofructose), supplementation protocols (from 5 to 20 gr per day of inulin consumed) and in microbiome assessment methods (16S sequencing, n = 7). The most consistent change was an increase in Bifidobacterium. Other concordant results included an increase in relative abundance of Anaerostipes, Faecalibacterium, and Lactobacillus, and a decrease in relative abundance of Bacteroides after inulin supplementation.
CONCLUSIONS
Our systematic review assessed the evidence for the effects of inulin supplementation on the human gut microbiome. However, these in vivo studies did not confirm in vitro experiments as the taxonomic alterations were not associated with increase in short-chain fatty acids levels.
Topics: Clinical Studies as Topic; Dietary Supplements; Gastrointestinal Microbiome; Humans; Inulin; Microbiota
PubMed: 31707507
DOI: 10.1007/s10096-019-03721-w -
The Journal of Prosthetic Dentistry Sep 2022A consensus that establishes the indications and clinical performance of removable partial denture (RPD) frameworks designed and manufactured with computer-aided design... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
A consensus that establishes the indications and clinical performance of removable partial denture (RPD) frameworks designed and manufactured with computer-aided design and computer-aided manufacturing (CAD-CAM) systems is lacking.
PURPOSE
The purpose of this systematic review and meta-analysis was to evaluate the currently published literature investigating different CAD-CAM methods and techniques for RPD manufacturing and their clinical performance.
MATERIAL AND METHODS
A comprehensive search of studies published up to September 2019 was performed in PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA Statement) criteria and was registered and approved in the International Prospective Register of Systematic Reviews (PROSPERO: CRD42020152197). The population, intervention, comparison, outcome (PICO) question was "Do the CAD-CAM frameworks have similar performances to those fabricated by conventional techniques?" The meta-analysis included clinical and in vitro studies based on the effect size and test of Null (2-Tail) with 95% confidence interval (CI). Clinical and in vitro studies were selected and analyzed separately.
RESULTS
A total of 15 articles out of 358 were selected. For clinical studies, quantitative analysis with a sample of 25 participants showed a mean discrepancy between occlusal rests and rest seats of 184.91 μm (95% CI: 152.6 μm-217.15 μm) and heterogeneity (I) of 0%. Clinical data considered that frameworks were acceptable for continuity of treatment. The predominant materials were cobalt-chromium (Co-Cr) and polyetheretherketone (PEEK), and studies using Co-Cr reported that the structure required adjustments. In addition, it has been reported that the indirect technique was time-consuming and selective laser melting (SLM) can be costly. PEEK structures have been more widely accepted because of improved esthetics. Quantitative data from the in vitro studies revealed that the additive manufacturing technique (2.006 mm: 95% CI: -2.021 mm to 6.032 mm) was not significantly different from the indirect technique (0.026 mm; P=.455; random: I: 98.402%).
CONCLUSIONS
Clinical studies and in vitro research on CAD-CAM planning and manufacturing of removable prosthesis frameworks are still sparse. However, preliminary data indicate a similar fit and esthetic improvement when compared with the conventional technique.
Topics: Benzophenones; Chromium; Cobalt; Computer-Aided Design; Computers; Denture, Partial, Removable; Esthetics, Dental; Humans; Polymers; Technology
PubMed: 33581866
DOI: 10.1016/j.prosdent.2020.06.006