Biofouling 2023This study aimed to review systematically the literature about the antimicrobial action of evaluated cleansers on the Co-Cr alloy of RPD. The search was conducted in... (Review)
Review
This study aimed to review systematically the literature about the antimicrobial action of evaluated cleansers on the Co-Cr alloy of RPD. The search was conducted in MEDLINE/PubMed, Scopus, Lilacs, Embase and Science Direct May, 2022. The review was performed based on PRISMA guidelines and recorded in Open Science Framework. Independent reviewers performed the search, selection, extraction, and analysis of the data. The risk of bias of the and clinical trials studies was analyzed by the Joanna Briggs Institute tool. A total of 187 articles were found and 9 were included. The cleansers that showed antimicrobial action were 2% and 5.25% sodium hypochlorite, 0.12% chlorhexidine and NitrAdine effervescent tablet. Polident, Corega Tabs effervescent tablets and 5 mg/mL chitosan solution showed intermediate effects. Propolis and green tea toothpaste were not effective. Three articles presented a high risk of bias and 6, low risk. The cleansers that showed the highest antimicrobial efficacy on Co-Cr alloy were 0.12% chlorhexidine digluconate and NitrAdine and can be safely used on RPD framework.
Topics: Chromium; Cobalt; Denture, Partial, Removable; Surface Properties; Biofilms; Anti-Infective Agents; Alloys
PubMed: 38047547
DOI: 10.1080/08927014.2023.2290120 -
Cureus Oct 2023The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not... (Review)
Review
The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not been extensively compared in prior studies. Moreover, there is no agreement on the more accurate method that entails less time in the laboratory and during the clinical phases of fabrication and delivery of the prosthesis, respectively. This review aimed to assess the precision of the imaging procedure and overall fabrication time of the DIT and CIT for the implant-supported FPDs. An electronic search was performed using PubMed, Scopus, EMBASE, Cochrane Oral Health Group, and Dentistry and Oral Science Source databases through EBSCO for relevant studies from January 2014 to April 2023. Following the preliminary screening, the studies that met the inclusion criteria underwent full-text review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Cochrane Collaboration risk of bias appraisal tool and Newcastle-Ottawa scale were applied to assess the quality of randomized controlled trials (RCTs) and non-randomized prospective clinical studies, respectively. The initial search yielded 332 studies, and after excluding duplicates, 241 papers were available for screening. Titles and abstracts were reviewed, and 97 articles were chosen for full-text review by two authors independently. Furthermore, 89 articles were excluded in compliance with the PICOS question, and eight studies were chosen for qualitative analysis. Hence, the review comprised two RCTs and six prospective clinical studies. The time efficiency of the implant-supported FPDs was examined in four investigations, three of which used the Trios 3 scanner and one used the Intero scanner. The three-dimensional accuracy of DIT and CIT was compared in six clinical comparative studies. One of the RCTs was rated to have a high risk of bias and the other with a moderate quality of evidence. The six prospective studies were rated to have high-quality of evidence. The findings of this review indicate the prospective applicability of future intraoral scanning systems. The DIT was reported to be outstanding in terms of patient preferences and total fabrication time efficiency. Additional in vivo studies are needed to establish the therapeutic usefulness and time efficiency of integrating DIT in more comprehensive settings.
PubMed: 38034200
DOI: 10.7759/cureus.48027 -
International Journal of Nanomedicine 2023The main objective of this systematic review was to evaluate the effect of coating with titanium dioxide nanoparticles (TiO nanoparticle) on the surface condition of... (Review)
Review
BACKGROUND
The main objective of this systematic review was to evaluate the effect of coating with titanium dioxide nanoparticles (TiO nanoparticle) on the surface condition of removable acrylic resin prosthetic base materials.
METHODS
Our review is registered in the PROSPERO database under the identification code CRD42023397170. Electronic database searches of PubMed, Scopus and Science Direct including studies from January 2009 to January 2023 were conducted and supplemented with manual searches. Research questions were generated in accordance with the PICO strategy. The modified Consolidated Standards of Reporting Trials (CONSORT) checklist was used to evaluate the quality of the selected studies.
RESULTS
Since the included studies were variable in design, a meta-analysis was not performed. The electronic searches retrieved 29 references that met the eligibility criteria, among which 5 studies matched the inclusion criteria for this review. Significant differences were detected between the TiO NP-coated and uncoated groups. The available data indicate that TiO NP coating elicits antimicrobial activity and improves the wear resistance of polymethylmethacrylate (PMMA) surfaces. Moreover, the nanoparticles provide high levels of glossiness and decelerate the process of color change of heat-cured acrylic resin, thus increasing the lifespan of dentures.
CONCLUSION
The collective results clearly indicate that TiO nanoparticle coating induces alterations in the surface properties of pure PMMA, enhancing the mechanical, physical and biological characteristics of the denture base material. Further studies are essential to identify the optimal thickness of coating and concentrations of nanoparticles for clinical applications.
Topics: Polymethyl Methacrylate; Denture Bases; Surface Properties; Acrylic Resins; Titanium; Materials Testing
PubMed: 38026530
DOI: 10.2147/IJN.S425702 -
The Journal of Prosthetic Dentistry Nov 2023Reports on digitally fabricated complete dentures are increasing. However, comprehensive evidence-based research on their cost-efficiency and patient-reported outcome... (Review)
Review
STATEMENT OF PROBLEM
Reports on digitally fabricated complete dentures are increasing. However, comprehensive evidence-based research on their cost-efficiency and patient-reported outcome measures (PROMs) is lacking.
PURPOSE
The purpose of this systematic review was to compare the cost-effectiveness and PROMs between digitally and conventionally fabricated complete dentures.
MATERIAL AND METHODS
An electronic search of publications from 2011 to mid-2023 was established using PubMed/Medline, EBSCOhost, and Google Scholar. Retrospective, prospective, randomized controlled, and randomized crossover clinical studies on at least 10 participants were included. A total of 540 articles were identified and assessed at the title, abstract, and full article level, resulting in the inclusion of 14 articles. Data on cost, number of visits, patient satisfaction, and oral health-related quality of life were examined and reported.
RESULTS
The systematic review included 572 digitally fabricated complete dentures and 939 conventionally fabricated complete dentures inserted in 1300 patients. Digitally fabricated complete dentures require less clinical time with a lower total cost, despite higher material costs compared with the conventional fabrication technique. Digitally and conventionally fabricated complete dentures were found to have significant effects on mastication efficiency, comfort, retention, stability, ease of cleaning, phonetics, and overall patient satisfaction, as well as social disability, functional limitation, psychological discomfort, physical pain, and handicap.
CONCLUSIONS
Digitally fabricated complete dentures are more cost-effective than conventionally fabricated dentures. There are various impacts of conventionally and digitally fabricated complete dentures on PROMs, and they are not better than one another.
PubMed: 38000966
DOI: 10.1016/j.prosdent.2023.10.028 -
The Journal of Prosthetic Dentistry Nov 2023The union of the metal removable partial denture framework to the heat polymerized acrylic resin is related to prosthesis longevity. However, methods to enhance this... (Review)
Review
STATEMENT OF PROBLEM
The union of the metal removable partial denture framework to the heat polymerized acrylic resin is related to prosthesis longevity. However, methods to enhance this bond are not clear to clinicians and dental laboratory technicians.
PURPOSE
The purpose of this systematic review was to identify which metal surface treatments best increase the bond strength between heat polymerized acrylic resin and removable partial denture alloys.
MATERIAL AND METHODS
This review was carried out following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and registered in the International Prospective Registry of Systematic Reviews (PROSPERO) database (CRD42022384926). Electronic searches were carried out independently, by 3 examiners in Medline/PubMed, Scopus, and Web of Science databases, and in the nonpeer-reviewed literature via ProQuest.
RESULTS
The electronic searches resulted in 4143 articles, with 4055 after removing duplicates. After reading the titles and abstracts, 37 articles were selected for reading in full-text version, from which 6 articles were included. All studies evaluated materials for conventional acrylic resin denture base (heat polymerized), processed by water bath, bonded to metal. For the metal framework alloys, cobalt chromium (Co-Cr) alloys were used in 2 studies, titanium (Ti) in 2 studies, and Co-Cr and Ti in the other 2 studies. Different metal surface treatments were used as airborne-particle abrasion with aluminum oxide (particle sizes of 50 µm, 110 µm, and 250 µm) followed by the primer application and the isolated use of the primer, compared to the absence of isolated intervention or airborne-particle abrasion of the metal surface. Among the different primers used, those based on 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) showed the highest acrylic resin-to-metal bond strength values.
CONCLUSIONS
Airborne-particle abrading the metal with AlO followed by applying a 10-MDP-based primer, increased the bond strength between metal framework alloys and heat polymerized acrylic resin denture base material.
PubMed: 37978008
DOI: 10.1016/j.prosdent.2023.10.009 -
Journal of Prosthodontics : Official... Jun 2024This systematic review and meta-analysis aimed to investigate the prevalence of opportunistic respiratory pathogens colonizing removable dental prostheses in older... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
This systematic review and meta-analysis aimed to investigate the prevalence of opportunistic respiratory pathogens colonizing removable dental prostheses in older adults without respiratory diseases.
METHODS
This review was registered with PROSPERO and conducted in accordance with the principles formed by the working group of the Joanna Briggs Institute (JBI) to evaluate systematic reviews of prevalence data. Literature searches were conducted across five electronic databases. Quality assessments were determined according to a revised JBI critical appraisal checklist across nine criteria. Comparison between fixed- and random-effects meta-analyses were performed for sensitivity analysis. Prediction intervals were also presented when three or more studies were included in the meta-analysis.
RESULTS
Across the databases, 1091 articles were identified, and 591 articles remained after the removal of duplicates. Twenty "potentially effective" studies were identified. Ultimately eight studies informed this review and meta-analyses were performed for 13 known respiratory pathogens. The meta-analyses identified the top three common respiratory pathogens residing on the removable prostheses were, in descending order: Staphylococcus aureus: 31.81% (95% CI: 13.34%-48.24%); Staphylococcus epidermidis: 14.07% (95% CI: 7.88%-21.48%); Klebsiella pneumoniae: 10.50% (95% CI: 2.55%-22.30%). The heterogeneity scores for nine respiratory pathogen analyses were classified as "unimportant inconsistency", I = 0% (p > 0.1). For sensitivity analysis, there was no difference between the random- and fixed-effects models.
CONCLUSION
The existing evidence demonstrated a high burden of certain opportunistic respiratory pathogens, which may be considered a major potential cause of respiratory infections in older adults wearing removable prostheses.
Topics: Humans; Aged; Prevalence; Respiratory Tract Infections; Staphylococcus aureus; Prosthesis-Related Infections; Staphylococcus epidermidis
PubMed: 37970708
DOI: 10.1111/jopr.13802 -
Journal of Prosthodontics : Official... Nov 2023This review aimed to summarize the evidence on patient-reported outcomes and clinical performance of digitally fabricated removable partial dentures (RPDs) compared to... (Review)
Review
PURPOSE
This review aimed to summarize the evidence on patient-reported outcomes and clinical performance of digitally fabricated removable partial dentures (RPDs) compared to traditionally fabricated dentures.
METHODS
Three databases were systematically searched (PubMed, CENTRAL, and Wiley online library) for clinical studies comparing digitally and conventionally fabricated RPDs regardless of data acquisition methods used for fabrication. The Cochrane Collaboration risk of bias assessment tool 2 and the Oxford Center for Evidence-based Medicine tool were used to assess risk of bias, and level of evidence, respectively. Descriptive narrative analysis was used to summarize data on patient-reported outcomes, as there were inadequate studies to pool data in a meta-analysis. A random-effects model was used to analyze the data of framework fit accuracy.
RESULTS
Ten randomized controlled trials were included in the systematic review, and 4 were included in the meta-analysis. Two studies showed that digitally fabricated RPDs are associated with higher patient satisfaction than conventionally fabricated RPDs (with a mean difference of 12.5 mm on a 100-satisfaction scale, p = .008). The pooled standardized mean difference for framework fit accuracy was 0.49 (p = 0.02) in favor of conventionally fabricated RPDs, which showed that conventionally fabricated RPDs have a quantitatively better fit compared to digitally fabricated RPDs. However, clinical evaluation studies showed that both frameworks have clinically acceptable fit.
CONCLUSIONS
Current evidence shows that digitally fabricated RPDs are associated with higher patient satisfaction compared to conventionally fabricated RPDs. However, the scarcity of literature here warrants the generalization of this conclusion. Both digitally and conventionally fabricated metal RPD frameworks showed acceptable fit clinically.
PubMed: 37930081
DOI: 10.1111/jopr.13786 -
Photobiomodulation, Photomedicine, and... Nov 2023This systematic review and meta-analysis aimed to assess the influence of laser treatment on adhesive bonding of liners to polymethyl methacrylate (PMMA) denture base... (Meta-Analysis)
Meta-Analysis
This systematic review and meta-analysis aimed to assess the influence of laser treatment on adhesive bonding of liners to polymethyl methacrylate (PMMA) denture base resins. The focused question was: "Does the application of laser treatment (Intervention) influence the adhesive bonding strength (Outcome) of liners to PMMA denture base resins (Population) as compared with untreated or unconditioned surfaces (Control)?" and clinical reports as well as reports on influence of laser treatments on bonding strength of liners to PMMA denture resins in comparison with untreated surfaces were included. Reports without any control group[s], without any application of laser[s] for PMMA denture bases that did not utilize PMMA denture bases, and not evaluate bond strength of PMMA denture base resins were excluded. An electronic search was conducted on PubMed, Scopus, and Web of Science. Meta-analyses were performed for calculating the standard mean difference (SMD) with a 95% confidence interval (95% CI). Nine of the 12 included studies found that laser irradiation treatment produced significant surface texture alterations of the PMMA denture base and improved the adhesion between the PMMA denture base and soft lining. According to the meta-analysis, tensile bond strength showed an SMD of -2.49% (95% CI: -3.89 to -1.08; = 0.0005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Regarding shear bond strength scores, the outcomes showed an SMD of -2.24% (95% CI: -3.79 to -0.69; = 0.005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Despite the high heterogeneity among the included studies, it can be concluded that laser treatment might improve the bonding strengths of liners to PMMA denture base resins as compared with untreated surfaces. To validate the aforementioned conclusions, further verification is required through the implementation of well-designed randomized controlled trials with large sample sizes.
Topics: Polymethyl Methacrylate; Denture Liners; Adhesives; Acrylic Resins; Materials Testing; Denture Bases
PubMed: 37910776
DOI: 10.1089/photob.2023.0066 -
Dentistry Journal Oct 2023Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose... (Review)
Review
Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and determine whether intraoral scanners have clinically acceptable accuracy when recording completely edentulous arches for the fabrication of removable complete dentures. An electronic search in medical databases like PubMed, Scopus, and Web of Science (WOS), using a combination of relevant keywords, retrieved 334 articles. After full-text evaluation, twelve articles fulfilled the inclusion criteria for this review (eight clinical studies and four in vitro studies). A quality analysis of the included studies was carried out using the QUADAS-2 tool. The accuracy values varied between different intraoral scanners. Different regions of the edentulous arches showed differences in trueness and precision values in both in vitro and clinical studies. Peripheral borders, the inner seal, and poorly traceable structures like the soft palate showed maximum discrepancies. The accuracy of intraoral scanners in recording clear anatomic landmarks like hard tissues with attached mucosa was comparable to conventional edentulous arch impressions. However, higher discrepancies were recorded when digitizing mobile and poorly traceable structures. Intraoral scanners can be used to digitize denture-bearing areas, but the interpretation of the peripheral border and the soft palate should be carefully carried out.
PubMed: 37886926
DOI: 10.3390/dj11100241 -
BMC Oral Health Oct 2023To evaluate the clinical efficacy of photodynamic therapy (PDT) as an adjunct or alternative to traditional antifungal drugs in the treatment of oral candidiasis, and to... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To evaluate the clinical efficacy of photodynamic therapy (PDT) as an adjunct or alternative to traditional antifungal drugs in the treatment of oral candidiasis, and to provide evidence-based medical evidence for its use in the treatment of oral candidiasis.
METHODS
Computer combined with manual retrieval of China Academic Journals Full-text Database (CNKI), China Biomedical Literature Database (CBM), Chinese Science and Technology Journal Database (VIP), Wanfang Database, PubMed, Web of Science, Cochrane Library, Embase, Scopus retrieval for articles published before January 2023, basic information and required data were extracted according to the inclusion and exclusion criteria, and the Revman V5.4 software was used to conduct Meta-analysis of the included literature.
RESULTS
A total of 11 articles were included, 7 of which used nystatin as an antifungal drug, 2 of which were combined treatment of PDT and nystatin, 2 of the remaining 4 articles were treated with fluconazole, and 2 were treated with miconazole. Meta results showed that PDT was superior to nystatin in reducing the number of oral candida colonies in the palate of patients MD = -0.87, 95%CI = (-1.52,-0.23), P = 0.008, the difference was statistically significant, and the denture site MD = -1.03, 95%CI = (-2.21, -0.15), P = 0.09, the difference was not statistically significant; compared with the efficacy of fluconazole, RR = 1.01, 95%CI = (0.56,1.83), P = 0.96; compared with miconazole RR = 0.55, 95%CI = (0.38, 0.81), P = 0.002; PDT combined with nystatin RR = 1.27, 95%CI = (1.06, 1.52), P = 0.01; recurrence rate RR = 0.28, 95%CI = (0.09, 0.88), P = 0.03.
CONCLUSIONS
PDT was effective in the treatment of oral candidiasis; PDT was more effective than nystatin for the treatment of denture stomatitis in the palate, while there was no significant difference between the two for the denture site; The efficacy of PDT for oral candidiasis was similar to that of fluconazole; PDT was less effective than miconazole for oral candidiasis; Compared with nystatin alone, the combination of PDT and nystatin is more effective in treating oral candidiasis with less risk of recurrence.
Topics: Humans; Candidiasis, Oral; Antifungal Agents; Nystatin; Fluconazole; Miconazole; Photochemotherapy
PubMed: 37884914
DOI: 10.1186/s12903-023-03484-z