ACS Biomaterials Science & Engineering Jun 2024In addition to transmitting and carrying genetic information, RNA plays an important abiotic role in the world of nanomaterials. RNA is a natural polyanionic...
In addition to transmitting and carrying genetic information, RNA plays an important abiotic role in the world of nanomaterials. RNA is a natural polyanionic biomacromolecule, and its ability to promote osteogenesis by binding with other inorganic materials as an osteogenic induction agent was discovered only recently. However, whether it can promote osseointegration on implants has not been reported. Here, we investigated the effect of the RNA-containing coating materials on peri-implant osseointegration. Total RNA extracted from rat muscle tissue was used as an osteogenic induction agent, and hyaluronic acid (HA) was used to maintain its negative charge. In simulated body fluids (SBF), in vitro studies demonstrated that the resulting material encouraged calcium salt deposition. Cytological experiments showed that the RNA-containing coating induced greater cell adhesion and osteogenic differentiation in comparison to the control. The results of animal experiments showed that the RNA-containing coating had osteoinductive and bone conduction activities, which are beneficial for bone formation and osseointegration. Therefore, the RNA-containing coatings are useful for the surface modification of titanium implants to promote osseointegration.
PubMed: 38943625
DOI: 10.1021/acsbiomaterials.4c00133 -
Journal of Biomechanics Jun 2024For some individuals with severe socket-related problems, prosthesis osseointegration directly connects a prosthesis to the residual limb creating a bone-anchored limb...
For some individuals with severe socket-related problems, prosthesis osseointegration directly connects a prosthesis to the residual limb creating a bone-anchored limb (BAL). We compared dynamic gait stability and between-limb stability symmetry, as measured by the Margin of Stability (MoS) and the Normalized Symmetry Index (NSI), for people with unilateral transfemoral amputation before and one-year after BAL implantation. The MoS provides a mechanical construct to assess dynamic gait stability and infer center of mass and limb control by relating the center of mass and velocity to the base of support. Before and one-year after BAL implantation, 19 participants walked overground at self-selected speeds. We quantified dynamic gait stability anteriorly and laterally at foot strike and at the minimum lateral MoS value. After implantation, we observed decreased lateral MoS at foot strike for the amputated (MoS mean(SD) %height; pre: 6.6(2.3), post: 5.9(1.3), d = 0.45) and intact limb (pre: 6.2(1.2), post: 5.8(1.0), d = 0.38) and increased between-limb MoS symmetry at foot strike (NSI mean(SD) %; anterior-pre: 10.3(7.3), post: 8.4(3.6), d = 0.23; lateral-pre: 18.8(12.4), post: 12.4(4.9), d = 0.47) and at minimum lateral stability (pre: 28.1(18.1), post: 19.2(6.8), d = 0.50). Center of mass control using a BAL resulted in dynamic gait stability more similar between limbs and may have reduced the adoption of functional asymmetries. We suggest that improved between-limb MoS symmetry after BAL implantation is likely due to subtle changes in individual limb MoS values at self-selected walking speeds resulting in an overall positive impact on fall risk through improved center of mass and prosthetic limb control.
PubMed: 38941842
DOI: 10.1016/j.jbiomech.2024.112208 -
The International Journal of Oral &... Jun 2024As the population gets older, the prevalence of complete or partial tooth loss is increasing, significantly impacting people's quality of life. Scientific research...
PURPOSE
As the population gets older, the prevalence of complete or partial tooth loss is increasing, significantly impacting people's quality of life. Scientific research demonstrates that implant-fixed complete dentures offer high levels of satisfaction. In certain cases, tooth loss can lead to significant bone atrophy, necessitating pre-implant bone reconstruction. We conducted a retrospective cohort study involving 43 arches, including or not bone grafts, rehabilitated using a stackable guided approach, which included an immediate loading protocol. The primary outcome measure was the survival rate of the implant at 4 months.
MATERIAL AND METHODS
The digital workflow helps the design of the provisional prothesis before the implant surgery, which will be loaded immediately after the implant's placement. The stacked guides integrate both surgical and prosthetic considerations into a digital workflow.
RESULT
A total of 284 implants were placed. After a 4-month follow-up period, 10 implants (3.5%) exhibited no osseointegration and were subsequently replaced, resulting in an overall success rate of 96.5%. After 1 year of follow-up, a prosthetic success rate of 100% was observed, with all patients being able to progress to the stages for the permanent fixed dentures.
CONCLUSION
Our findings support the use of this protocol for all patients, whether they require bone grafts or not. However, a long-term follow-up is essential for a comprehensive evaluation of these treatment outcomes.
PubMed: 38941165
DOI: 10.11607/jomi.10998 -
Clinical Oral Investigations Jun 2024The aim of this study was to evaluate whether thermal implant removal of osseointegrated implants is possible using a diode laser with an specific temperature-time...
OBJECTIVES
The aim of this study was to evaluate whether thermal implant removal of osseointegrated implants is possible using a diode laser with an specific temperature-time interval.
MATERIALS AND METHODS
First, tooth extraction of the first three premolars was performed in the maxilla and mandible on both sides of 10 pig. After 3 months, implants were inserted into the upper and lower jaws of 10 pigs. After 3 more months, osseointegrated implants were heated with a laser device to a temperature of 50 °C for 1 min. After 14 days, the implant stability quotient (ISQ), torque-out values, and bone-to-implant contact (BIC) ratio were assessed using resonance frequency analysis.
RESULTS
ISQ values showed no significant differences within each group or between the control and test groups. Furthermore, torque-out and BIC value measurements presented no significant differences between the groups.
CONCLUSIONS
At 50°C, changes in the BIC values were noticeably smaller; however, these differences were not significant. Future studies should evaluate the same procedures at either a higher temperature or longer intervals.
CLINICAL RELEVANCE
With only 50 °C for 1 min, a dental implant will not de-integrate predictably.
Topics: Animals; Swine; Dental Implants; Device Removal; Proof of Concept Study; Hot Temperature; Resonance Frequency Analysis; Dental Implantation, Endosseous; Torque; Osseointegration
PubMed: 38937381
DOI: 10.1007/s00784-024-05619-0 -
International Journal of Biological... Jun 2024Polyether-ether-ketone (PEEK) is clinically used as a bio-implant for the healing of skeletal defects. However, the osseointegration of clinical-sized bone grafts...
Polyether-ether-ketone (PEEK) is clinically used as a bio-implant for the healing of skeletal defects. However, the osseointegration of clinical-sized bone grafts remains limited. In this study, surface-porous PEEK was created by using a sulfonation method and a metal-polysaccharide complex MgCS was introduced on the surface of sulfonated PEEK to form MgCS@SPEEK. The as-prepared MgCS@SPEEK was found to have a porous surface with good hydrophilicity and bioactivity. This was followed by an investigation into whether MgCS loaded onto sulfonated PEEK surfaces could promote osseointegration and angiogenesis. The in vitro results showed that MgCS@SPEEK had a positive effect on reducing the expression levels of inflammatory genes and promoting osteogenesis and angiogenesis-related genes expression levels. Furthermore, porous MgCS@SPEEK was implanted in critical-sized rat tibiae defects for in vivo evaluation of osseointegration. The microcomputed tomography evaluation results revealed substantial bone formation at 4 and 8 weeks. Collectively, these findings indicate that MgCS@SPEEK could provide improved osseointegration and an attractive strategy for orthopedic applications.
PubMed: 38936580
DOI: 10.1016/j.ijbiomac.2024.133435 -
Cureus May 2024Dental implantology is continually evolving in its quest to discover new biomaterials to improve dental implant success rates. The study explored the potential of...
BACKGROUND
Dental implantology is continually evolving in its quest to discover new biomaterials to improve dental implant success rates. The study explored the potential of innovative biomaterials for dental implant surfaces, including titanium-zirconium (Ti-Zr) alloy, hydroxyapatite-coated titanium (HA-Ti), and porous polyetheretherketone (PEEK), in comparison to conventional commercially pure titanium (CP Ti).
MATERIALS AND METHODS
A total of 186 samples were harvested for the analysis. Biomaterials were thoroughly evaluated in terms of surface topography, chemical composition, biocompatibility, mechanical properties, osseointegration performance, and bacterial adhesion. Study methods and techniques included scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), cell culture variants, tensile tests, hardness measurements, histological analysis, and microbiological testing.
RESULTS
Surface topography examination showed significant disparities between the biomaterials: Ti-Zr had a better roughness of 1.23 μm, while HA-Ti demonstrated a smoother surface at 0.98 μm. Chemical composition evaluation indicated the presence of a Ti-Zr alloy in Ti-Zr, calcium-phosphorus richness in HA-Ti, and high titanium amounts in CP Ti. The mechanical properties assessment showed that Ti-Zr and CP Ti had good tensile strengths of 750 MPa and 320 HV. In addition, bacterial adhesion tests showed low propensities for Ti-Zr and HA-Ti at 1200 and 800 cfu/cm, respectively.
CONCLUSION
Ti-Zr and HA-Ti performed better than the other biomaterials in surface topography and mechanical properties and against bacterial adhesion. This study emphasizes that multi-parameter analysis is critical for clinical decision-making, allowing for the selection of the currently available biomaterial, which could be conducive to the long-term success of the implant.
PubMed: 38933613
DOI: 10.7759/cureus.61175 -
Microorganisms Jun 2024Glucocorticoids may be given prior to major orthopedic surgery to decrease postoperative nausea, vomiting, and pain. Additionally, many orthopedic patients may be on...
Glucocorticoids may be given prior to major orthopedic surgery to decrease postoperative nausea, vomiting, and pain. Additionally, many orthopedic patients may be on chronic glucocorticoid therapy. The aim of our study was to investigate whether glucocorticoid administration influences Orthopedic-Device-Related Infection (ODRI) in a rat model. Screws colonized with were implanted in the tibia of skeletally mature female Wistar rats. The treated groups received either a single shot of dexamethasone in a short-term risk study, or a daily dose of dexamethasone in a longer-term interference study. In both phases, bone changes in the vicinity of the implant were monitored with microCT. There were no statistically significant differences in bacteriological outcome with or without dexamethasone. In the interference study, new bone formation was statistically higher in the dexamethasone-treated group ( = 0.0005) as revealed by CT and histopathological analysis, although with relatively low direct osseointegration of the implant. In conclusion, dexamethasone does not increase the risk of developing periprosthetic osteolysis or infection in a pre-clinical model of ODRI. Long-term administration of dexamethasone seemed to offer a benefit in terms of new bone formation around the implant, but with low osseointegration.
PubMed: 38930516
DOI: 10.3390/microorganisms12061134 -
Journal of Clinical Medicine Jun 2024Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate... (Review)
Review
Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate reconstruction is crucial to address complications such as malocclusion, mandibular deviation, temporomandibular joint (TMJ) changes, and soft tissue retraction. These issues can lead to functional impairments, including difficulties in chewing, swallowing, and speech. The fibula flap is widely used for mandibular reconstruction due to its long bone segment and robust vascular supply, though it may not always provide adequate bone height for optimal dental rehabilitation. This systematic review aims to determine if the double-barreled fibula flap (DBFF) configuration is a viable alternative for mandibular reconstruction and to evaluate the outcomes of dental implants placed in this type of flap. This study adhered to the Cochrane Collaboration criteria and PRISMA guidelines and was registered on the International Platform of Registered Systematic Review and Meta-Analysis Protocols Database (INPLASY2023120026). We included clinical studies published in English, Spanish, or French that focused on adult patients undergoing segmental mandibulectomy followed by DBFF reconstruction and dental rehabilitation. Data sources included Medline/PubMed, the Cochrane Library, EMBASE, Scopus, and manual searches. Two reviewers independently screened and selected studies, with discrepancies resolved by a third reviewer. Data extraction captured variables such as publication year, patient demographics, number of implants, follow-up duration, flap survival, implant failure, and aesthetic outcomes. The risk of bias was assessed using the JBI appraisal tool, and the certainty of evidence was evaluated using the GRADE approach. A total of 17 clinical studies were included, evaluating 245 patients and 402 dental implants. The average patient age was 43.7 years, with a mean follow-up period of 34.3 months. Flap survival was high, with a 98.3% success rate and only four flap losses. The implant failure rate was low at 1.74%. Esthetic outcomes were varied, with only three studies using standardized protocols for evaluation. The overall certainty of evidence for flap survival was moderate, low for implant failure, and very low for aesthetics due to the subjective nature of assessments and variability in reporting. The primary limitations of the evidence included in this review are the observational design of the studies, leading to an inherent risk of bias, inconsistency in reporting methods, and imprecision in outcome measures. Additionally, the subjective nature of aesthetic evaluations and the variability in assessment tools further limit the reliability of the findings. The DBFF technique demonstrates excellent outcomes for mandibular reconstruction, with high flap survival and low implant failure rates, making it a viable option for dental rehabilitation. However, the evidence for aesthetic outcomes is less certain, highlighting the need for more rigorous and standardized research. This review supports the DBFF as a good alternative for mandibular reconstruction with successful dental implant integration, although further studies are needed to enhance the reliability of aesthetic evaluations.
PubMed: 38930078
DOI: 10.3390/jcm13123547 -
Medicina (Kaunas, Lithuania) May 2024: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets... (Meta-Analysis)
Meta-Analysis Comparative Study Review
: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets with and without periapical pathology. : After the search and review of the literature in the electronic databases, 109 publications were achieved. The titles and abstracts of 66 publications were screened. After the evaluation of the full text of 22 publications, based on the inclusion criteria, six controlled clinical studies were included in this systematic review and meta-analysis. The statistical calculation showed no heterogeneity among the studies included. The implant survival was 99.6% in the test (socket with periapical pathology) and control (socket without periapical pathology) groups of all the clinical trials. The results of the meta-analysis showed no statistically significant difference between test and control groups regarding the marginal bone level and the width of keratinized mucosa in all the studies. Other parameters indicating plaque level, bleeding on probing, and gingival recession also did not differ between test and control groups at the final follow-up in nearly all studies. : Within the limitation of this systemic review and meta-analysis, the obtained data suggest that implants immediately placed into the extraction sockets of teeth exhibiting periapical pathology can be successfully osseointegrated for an extended period.
Topics: Humans; Tooth Socket; Dental Implantation, Endosseous; Dental Implants; Immediate Dental Implant Loading
PubMed: 38929509
DOI: 10.3390/medicina60060893 -
Bioengineering (Basel, Switzerland) Jun 2024(1) Background: When placing implants in the maxillary posterior region with insufficient alveolar bone, a maxillary sinus elevation is necessary. Autogenous bone,...
(1) Background: When placing implants in the maxillary posterior region with insufficient alveolar bone, a maxillary sinus elevation is necessary. Autogenous bone, though biologically ideal, poses risks and discomfort due to donor site harvesting. Block-type autogenous tooth bone graft material, made from the patient's own extracted tooth, offers similar biological stability without these drawbacks. (2) Methods: This study observed the progress of 19 implant patients who were treated with maxillary sinus elevation procedures using block-type autogenous tooth bone graft material at the Daegu Catholic University Medical Center. Extracted teeth were processed into demineralized tooth block bone. After elevating the sinus membrane, implants and the tooth bone graft material were placed in the space, and the bony window was repositioned. Postoperative evaluations through clinical observation and radiographic imaging assessed sinus membrane elevation, alveolar bone height increase, and implant osseointegration. (3) Results: Results showed proportional increases in alveolar bone height to the graft material size, with long-term stability. No postoperative complications occurred, even with sinus membrane perforation, and implants remained stable. (4) Conclusions: The study concludes that maxillary sinus lifts using block-type autogenous tooth bone graft material provide excellent bone induction and biocompatibility, making this a highly beneficial method for both dentists and patients.
PubMed: 38927869
DOI: 10.3390/bioengineering11060633