-
Journal of Pharmacy & Bioallied Sciences Feb 2024This systematic review examines the efficacy and biocompatibility of orthodontic clear aligner tooth aligners constructed from polyethylene terephthalate glycol (PeT-G),...
Effectiveness and Biocompatibility of Tooth Aligners Made from Polyethylene Terephthalate Glycol (PeT-G), Polypropylene (PP), Polycarbonate (PC), Thermoplastic Polyurethanes (TPUs), and Ethylene-Vinyl Acetate (EVA): A Systematic Review.
OBJECTIVE
This systematic review examines the efficacy and biocompatibility of orthodontic clear aligner tooth aligners constructed from polyethylene terephthalate glycol (PeT-G), polypropylene (PP), polycarbonate (PC), thermoplastic polyurethanes (TPUs), and ethylene-vinyl acetate (EVA).
MATERIALS AND METHODS
To find relevant papers published through September 2021, PubMed was searched extensively. Randomized clinical trials (RCTs) and observational studies assessing the effectiveness and biocompatibility of the aligner materials were included. Data were extracted independently, and the quality of included research was appraised using relevant procedures. The research variability necessitated a narrative synthesis.
RESULTS
Five studies were included for comparison. All materials were biocompatible; however, PeT-G and EVA aligners caused the least tissue irritation. Patients preferred TPU aligners for initial comfort and PeT-G aligners for transparency and endurance.
CONCLUSION
Biocompatible PeT-G, PP, PC, TPU, and EVA tooth aligners fix malocclusions. Aligner materials should be chosen based on patient preferences, treatment goals, and material qualities. For stronger proof, a longer-term study is needed.
PubMed: 38595485
DOI: 10.4103/jpbs.jpbs_883_23 -
International Journal of Nursing Studies Jan 2024Central venous catheters are commonly used in healthcare, but they come with a range of potential complications. Over the last 15 years, an influx of securement and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Central venous catheters are commonly used in healthcare, but they come with a range of potential complications. Over the last 15 years, an influx of securement and dressing products has been released, with unknown overall effectiveness to prevent these complications.
OBJECTIVE
To compare the effects of dressings and securement devices for central venous catheters on a range of common complications including catheter-related bloodstream infection, catheter tip colonisation, entry/exit-site infection, skin colonisation, skin irritation, failed catheter securement, dressing durability and mortality.
DESIGN
Systematic review with meta-analysis.
METHODS
Following standard Cochrane methods, a systematic search of Cochrane Wounds Trials Register, Cochrane Central Register of Controlled Trials, MEDLINE Ovid, Embase Ovid, EBSCO CINAHL, and multiple clinical trial registries was completed in November 2022. Randomised controlled trials evaluating the effectiveness of dressing and securement devices for all CVC types were included. A random-effects model was used during the meta-analysis. Results were expressed using risk ratio (RR), rate ratio, or mean difference (MD), with 95 % confidence intervals (CIs). Methodological quality and bias were assessed.
RESULTS
We included 46 studies involving 10,054 participants. All studies had either an unclear or high-performance bias. The blinding of outcome assessment was unclear in most studies. Chlorhexidine gluconate-impregnated dressings, compared with standard polyurethane dressings, may reduce the incidence (7 studies; N = 5816; RR 0.60, 95 % CI 0.44-0.83; low certainty evidence) and rate (4 studies; N = 4447; RR 0.51, 95 % CI 0.32-0.79; moderate certainty evidence) of catheter-related bloodstream infection and catheter tip colonisation (8 studies; N = 4788; RR 0.70, 95 % CI 0.52-0.95; very low certainty evidence). Medication-impregnated dressings may reduce the incidence of catheter-related bloodstream infection (6 studies; N = 5687; RR 0.60, 95 % CI 0.39-0.93; low certainty evidence) and catheter-tip colonisation (7 studies; N = 4769; RR 0.60, 95 % CI 0.47-0.76; low certainty evidence) relative to non-impregnated dressing types. Tissue adhesive may increase the risk of skin irritation or damage compared with integrated securement dressings (3 studies; N = 166; RR 1.88, 95 % CI 1.09-3.24; low certainty evidence) or sutureless securement devices (4 studies; N = 241; RR 1.64, 95 % CI 1.10-2.44; moderate certainty evidence). Tissue adhesive increased dressing durability compared with integrated securement dressings (MD 43.03 h, 95 % CI 4.88-81.18; moderate certainty evidence) and sutureless securement devices (MD 42.90 h, 4.64-81.16; moderate certainty evidence). Tissue adhesive increased failed catheter securement rate compared with suture (2 studies; N = 103; RR 9.33, 95 % CI 1.10-79.21; moderate certainty evidence).
CONCLUSIONS
The findings of the review provide insights and guidance for clinicians in selecting the appropriate dressings and securements for catheters. Findings should be interpreted with caution due to heterogeneity in catheters and patient types.
REGISTRATION
#CD010367.
TWEETABLE ABSTRACT
Time to implement chlorhexidine gluconate-impregnated dressings to prevent catheter-related bloodstream infections; a meta-analysis by @GraceNP and team.
Topics: Humans; Central Venous Catheters; Tissue Adhesives; Bandages; Sepsis
PubMed: 37879273
DOI: 10.1016/j.ijnurstu.2023.104620 -
Handchirurgie, Mikrochirurgie,... Aug 2023Breast implant-associated squamous cell carcinoma (BIA-SCC) is being discussed as a distinct malignant tumour entity originating from the implant capsule. The FDA and...
BACKGROUND
Breast implant-associated squamous cell carcinoma (BIA-SCC) is being discussed as a distinct malignant tumour entity originating from the implant capsule. The FDA and the ASPS published a safety communication on BIA-SCC in 2022, with a first case report of BIA-SCC having been published in the 1990s. This manuscript summarises the current scientific data on this rare tumour entity.
MATERIAL AND METHODS
This systematic literature review from two independent databases includes all publications of cases with histopathologically confirmed BIA-SCC. Data extraction included study design, demographic data, implant information and details regarding diagnosis and treatment.
RESULTS
Nineteen cases of BIA-SCC with a mean age of 57±10 years were reported in 16 publications. In most cases, the indication was aesthetic augmentation (n=13). Both silicone (n=11) and saline (n=7) implants with different surfaces (smooth n=3, textured n=3, polyurethane n=1) were used. Symptoms such as unilateral swelling (n=18), pain (n=14) and erythema (n=5) occurred on an average of 23±9 years after implantation. Imaging showed fluid collection (n=8) or a tumour mass (n=4) around the breast implant. The most common surgical treatment was explantation with capsulectomy. Metastasis was described in 6 cases.
CONCLUSIONS
BIA-SCC is a malignant tumour entity associated with breast implant capsules. Based on current low-quality data (level of evidence class V), no definitive conclusion regarding correlation and causality of SCC in patients with breast implants can be drawn. There is an urgent need for national and international breast implant and breast cancer registries to obtain valid data on the incidence, pathogenesis and clinical presentation of rare tumour entities.
Topics: Humans; Middle Aged; Aged; Female; Breast Implants; Breast Neoplasms; Breast Implantation; Device Removal; Carcinoma, Squamous Cell
PubMed: 37473774
DOI: 10.1055/a-2108-9111 -
Breast (Edinburgh, Scotland) Oct 2023Radiation dermatitis (RD) is the most common side effect of adjuvant whole-breast or chest wall irradiation, majorly impacting quality of life in numerous patients. The... (Meta-Analysis)
Meta-Analysis
PURPOSE
Radiation dermatitis (RD) is the most common side effect of adjuvant whole-breast or chest wall irradiation, majorly impacting quality of life in numerous patients. The use of barrier films (polyurethane dressings such as Hydrofilm® and Mepitel® film remaining on the skin for the duration of the radiation treatment) has been investigated as a prophylactic measure in several prospective trials. Here, we critically appraise the available evidence behind preventive barrier film application in the context of breast cancer treatment.
METHODS
International literature was reviewed and high-quality randomised controlled trials (RCTs) were included in this meta-analysis.
RESULTS
The results of 5 RCTs (663 patients; >90% Caucasian) were analysed. Overall, barrier films lead to improved clinician- and patient-reported outcomes: fewer grade ≥2 RD (11% vs. 42%; OR = 0.16; p < 0.001) and moist desquamation (2% vs. 16%; OR = 0.12; p = 0.006), as well as less patient-reported pain (standardised mean difference [SMD] -0.51; p < 0.001), itching (SMD -0.52; p = 0.001), burning (SMD -0.41; p = 0.011), and limitations in daily activities (SMD -0.20; p = 0.007). Furthermore, barrier films have a high acceptance rate among patients, as well as a favourable cost-benefit ratio. Possible side effects due to its application are mild and mostly self-limiting. Overall, there was a lack of information on the radiation treatment techniques used.
CONCLUSION
The evidence presented in this meta-analysis suggests that barrier films are an excellent tool in the prevention of RD among Caucasian patients receiving whole-breast or chest wall irradiation. Its use should therefore be considered routinely in these patients.
Topics: Humans; Female; Breast Neoplasms; Radiodermatitis; Skin; Randomized Controlled Trials as Topic
PubMed: 37473629
DOI: 10.1016/j.breast.2023.07.001 -
EFORT Open Reviews Apr 2023The biomechanical characteristics of different techniques to perform the modified Lapidus procedure are controversial, discussing the issue of stability, rigidity, and... (Review)
Review
PURPOSE
The biomechanical characteristics of different techniques to perform the modified Lapidus procedure are controversial, discussing the issue of stability, rigidity, and compression forces from a biomechanical point of view. The aim of this systematic review was to investigate the available options to identify whether there is a procedure providing superior biomechanical results.
METHODS
A comprehensive literature search was performed by screening PubMed, Embase, and Cochrane databases until September 2021. There was a wide heterogeneity of the available data in the different studies. Load to failure, stiffness, and compression forces were summarized and evaluated.
RESULTS
Seventeen biomechanical studies were retrieved - ten cadaveric and seven polyurethane foam (artificial bone) studies. Fixation methods ranged from the classic crossed screw approach (n = 5) to plates (dorsomedial and plantar) with or without compression screws (n = 11). Newer implants such as intramedullary stabilization screws (n = 1) and memory alloy staples (n = 2) were investigated.
CONCLUSION
The two crossed screws construct is still a biomechanical option; however, according to this systematic review, there is strong evidence that a plate-screw construct provides superior stability especially in combination with a compression screw. There is also evidence about plate position and low evidence about compression screw position. Plantar plates seem to be advantageous from a biomechanical point of view, whereas compression screws could be better when positioned outside the plate. Overall, this review suggests the biomechanical advantages of using a combination of locking plates with a compression screw.
PubMed: 37097047
DOI: 10.1530/EOR-22-0069 -
Medicina Oral, Patologia Oral Y Cirugia... Jan 2023Recurrent Aphtous Stomatitis (RAS) is the most common process affecting the oral mucosa. It is painful, multifactorial and generally recurrent. The aim of this...
BACKGROUND
Recurrent Aphtous Stomatitis (RAS) is the most common process affecting the oral mucosa. It is painful, multifactorial and generally recurrent. The aim of this systematic review is to know the last treatment approaches and their effectivity.
MATERIAL AND METHODS
we compared the outcome of different kind of treatments in terms of the improvement of the lesions, reduction of the size of those lesions and the time needed for their healing. Inclusion criteria were: clinical trials, articles written in English or Spanish and published less than 5 years ago.
RESULTS
we used the following keywords: "treatment", "aphtous stomatitis", "canker sores"; combined with Boolean operators AND y OR. We selected 28 articles for reading the whole text, and after applying the eligibility criteria, we selected 17 articles for our revision. Among all the treatments, we emphasize the barrier method based in compound of cellulose rubber and a calcium/sodium copolymer PVM/MA, with which the difference in the 3rd and 7th day was of -6,29 ± 0,14 points in the pain score. The treatment with insulin and chitosan gel, brought a pain suppression on the third day, with no reactivation of the pain during the whole study. The application of a film composed of polyurethane and sesame oil with chitosan, brought a reduction in the size of the lesions of 4,54 ± 2,84mm on the 6th day compared with the situation before the beginning of the treatment. The different kinds of laser, which produced a reduction in the pain score just at the beginning of the treatment up to 8,1 ± 1,6 points, and a reduction of the size of the lesions of 4,42 ± 1,02mm on the 7th day.
CONCLUSIONS
Besides the classic treatments for RAS, we have to take into account other treatment modalities, above all the different kinds of laser.
Topics: Humans; Chitosan; Stomatitis, Aphthous; Stomatitis; Mouth Mucosa; Pain
PubMed: 36173717
DOI: 10.4317/medoral.25604 -
Polymers Jul 2022Flame-retardant science and technology are sciences developed to prevent the occurrence of fire, meet the needs of social safety production, and protect people's lives... (Review)
Review
Flame-retardant science and technology are sciences developed to prevent the occurrence of fire, meet the needs of social safety production, and protect people's lives and property. Rigid polyurethane (PU) is a polymer formed by the additional polymerization reaction of a molecule with two or more isocyanate functional groups with a polyol containing two or more reactive hydroxyl groups under a suitable catalyst and in an appropriate ratio. Rigid polyurethane foam (RPUF) is a foam-like material with a large contact area with oxygen when burning, resulting in rapid combustion. At the same time, RPUF produces a lot of toxic gases when burning and endangers human health. Improving the flame-retardant properties of RPUF is an important theme in flame-retardant science and technology. This review discusses the development of flame-retardant RPUF through the lens of bibliometrics. A total of 194 articles are analyzed, spanning from 1963 to 2021. We describe the development and focus of this theme at different stages. The various directions of this theme are discussed through keyword co-occurrence and clustering analysis. Finally, we provide reasonable perspectives about the future research direction of this theme based on the bibliometric results.
PubMed: 35893975
DOI: 10.3390/polym14153011 -
Polymers Jul 2022Dressings made with polyurethanes have been found to exhibit good and varied biological properties that make them good candidates for this application. However, as has... (Review)
Review
Dressings made with polyurethanes have been found to exhibit good and varied biological properties that make them good candidates for this application. However, as has been seen, the wound-healing process is complex, which includes four different stages. So far, the design and evaluation of polyurethane for wound dressing has focused on achieving good properties (mechanical, physicochemical, and biological), but each of them separates from the others or even directed at only one of the stages of skin wound-healing. Therefore, the aim of this systematic review is to explore the applications of polyurethanes in wound dressings and to determine whether could be designed to cover more than one stage of skin wound-healing. The PRISMA guidelines were followed. The current research in this field does not consider each stage separately, and the design of polyurethane dressings is focused on covering all the stages of wound healing with a single material but is necessary to replace polyurethanes in short periods of time. Additionally, little emphasis is placed on the hemostasis stage and further characterization of polyurethanes is still needed to correlate mechanical and physicochemical properties with biological properties at each stage of the wound-healing. Current research demonstrates an effort to characterize the materials physiochemically and mechanically, but in terms of their biological properties, most of the literature is based on the performance of histological tests of explants morphologically probing the compromised tissues, which give an indication of the potential use of polyurethanes in the generation of wound-healing dressings.
PubMed: 35893955
DOI: 10.3390/polym14152990 -
The Cochrane Database of Systematic... May 2022Sacrococcygeal pilonidal sinus disease is a common debilitating condition that predominantly affects young adults, with a profound impact on their activities of daily... (Review)
Review
BACKGROUND
Sacrococcygeal pilonidal sinus disease is a common debilitating condition that predominantly affects young adults, with a profound impact on their activities of daily living. The condition is treated surgically, and in some cases the wound in the natal cleft is left open to heal by itself. Many dressings and topical agents are available to aid healing of these wounds.
OBJECTIVES
To assess the effects of dressings and topical agents for the management of open wounds following surgical treatment for sacrococcygeal pilonidal sinus in any care setting.
SEARCH METHODS
In March 2021, we searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase and EBSCO CINAHL Plus. We also searched clinical trials registries for ongoing and unpublished studies, and we scanned reference lists of included studies, reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting.
SELECTION CRITERIA
We included parallel-group randomised controlled trials (RCTs) only. We included studies with participants who had undergone any type of sacrococcygeal pilonidal sinus disease surgery and were left with an open wound.
DATA COLLECTION AND ANALYSIS
We used the standard methodological procedures expected by Cochrane. We used GRADE to assess the certainty of the evidence for each outcome.
MAIN RESULTS
We included 11 RCTs comprising 932 participants. Two studies compared topical negative pressure wound therapy (TNPWT) with conventional open wound healing, two studies compared platelet-rich plasma with sterile absorbent gauze, and the other seven studies compared various dressings and topical agents. All studies were at high risk of bias in at least one domain, whilst one study was judged to be at low risk of bias in all but one domain. All studies were conducted in secondary care. Mean participant ages were between 20 and 30 years, and nearly 80% of participants were male. No studies provided data on quality of life, cost-effectiveness, pain at first dressing change or proportion of wounds healed at 6 or 12 months, and very few adverse effects were recorded in any study. It is unclear whether TNPWT reduces time to wound healing compared with conventional open wound healing (comparison 1), as the certainty of evidence is very low. The two studies provided conflicting results, with one study showing benefit (mean difference (MD) -24.01 days, 95% confidence interval (CI) -35.65 to -12.37; 19 participants), whilst the other reported no difference. It is also unclear whether TNPWT has any effect on the proportion of wounds healed by 30 days (risk ratio (RR) 3.60, 95% CI 0.49 to 26.54; 19 participants, 1 study; very low-certainty evidence). Limited data were available for our secondary outcomes time to return to normal daily activities and recurrence rate; we do not know whether TNPWT has any effect on these outcomes. Lietofix cream may increase the proportion of wounds that heal by 30 days compared with an iodine dressing (comparison 4; RR 8.06, 95% CI 1.05 to 61.68; 205 participants, 1 study; low-certainty evidence). The study did not provide data on time to wound healing. We do not know whether hydrogel dressings reduce time to wound healing compared with wound cleaning with 10% povidone iodine (comparison 5; MD -24.54 days, 95% CI -47.72 to -1.36; 31 participants, 1 study; very low-certainty evidence). The study did not provide data on the proportion of wounds healed. It is unclear whether hydrogel dressings have any effect on adverse effects as the certainty of the evidence is very low. Platelet-rich plasma may reduce time to wound healing compared with sterile absorbent gauze (comparison 6; MD -19.63 days, 95% CI -34.69 to -4.57; 210 participants, 2 studies; low-certainty evidence). No studies provided data on the proportion of wounds healed. Platelet-rich plasma may reduce time to return to normal daily activities (MD -15.49, 95% CI -28.95 to -2.02; 210 participants, 2 studies; low-certainty evidence). Zinc oxide mesh may make little or no difference to time to wound healing compared with placebo (comparison 2; median 54 days in the zinc oxide mesh group versus 62 days in the placebo mesh group; low-certainty evidence). We do not know whether zinc oxide mesh has an effect on the proportion of wounds healed by 30 days as the certainty of the evidence is very low (RR 2.35, 95% CI 0.49 to 11.23). It is unclear whether gentamicin-impregnated collagen sponge reduces time to wound healing compared with no dressing (comparison 7; MD -1.40 days, 95% CI -5.05 to 2.25; 50 participants, 1 study; very low-certainty evidence). The study did not provide data on the proportion of wounds healed. Dialkylcarbamoyl chloride (DACC)-coated dressings may make little or no difference to time to wound healing compared with alginate dressings (comparison 8; median 69 (95% CI 62 to 72) days in the DACC group versus 71 (95% CI 69 to 85) days in the alginate group; 1 study, 246 participants; low-certainty evidence). One study compared a polyurethane foam hydrophilic dressing with an alginate dressing (comparison 3) whilst another study compared a hydrocolloid dressing with an iodine dressing (comparison 9). It is unclear whether either intervention has any effect on time to wound healing as the certainty of evidence is very low.
AUTHORS' CONCLUSIONS
At present, the evidence that any of the dressings or topical agents contained in this review have a benefit on time to wound healing, the proportion of wounds that heal at a specific time point or on any of the secondary outcomes of our review ranges from low certainty to very low certainty. There is low-certainty evidence on the benefit on wound healing of platelet-rich plasma from two studies and of Lietofix cream and hydrogel dressings from single studies. Further studies are required to investigate these interventions further.
Topics: Adult; Alginates; Bandages; Female; Humans; Hydrogels; Iodine; Male; Pilonidal Sinus; Young Adult; Zinc Oxide
PubMed: 35593897
DOI: 10.1002/14651858.CD013439.pub2 -
Cureus Nov 2021Herein, we compare the outcomes of polyurethane and calcium alginate dressings for split-thickness skin graft (STSG) donor sites. A systematic review and meta-analysis... (Review)
Review
Herein, we compare the outcomes of polyurethane and calcium alginate dressings for split-thickness skin graft (STSG) donor sites. A systematic review and meta-analysis were conducted with a search of electronic databases to identify all randomised controlled trials (RCTs) and observational studies comparing the outcomes of polyurethane dressing versus calcium alginate for STSG donor sites. Primary outcomes were pain intensity, convenience for staff and patients, and adverse effects (namely, excessive exudate, infection rate, and hematoma). Secondary outcome measures included the assessment of healing, dressing changes, cosmetic appearance, and cost. Fixed and random-effect models were used for the analysis. Four RCTs enrolling 127 subjects were identified. There was no significant difference between polyurethane and calcium alginate in terms of pain intensity on Day 1 (mean difference (MD) 0.13, P = 0.80) and Day 5 (MD = 0.20, P = 0.38), as well as the ease of application (odds ratio (OR) = 3.08, P = 0.47). However, there was a statistically significant improvement in patient comfort, favouring the polyurethane group (OR = 44.11, P < 0.00001). In addition, no statistically significant differences were noted in terms of adverse effects between the two dressings. In terms of cost, the calcium gluconate dressing had an overall higher cost compared to polyurethane. Polyurethane is a more favourable dressing compared to calcium alginate for STSG donor sites in terms of patient comfort, healing, and cosmetic outcomes. However, comparable results were noted in terms of pain intensity, ease of application, and adverse effects profile. Cost-effectiveness analysis studies are required to justify its routine use.
PubMed: 34987912
DOI: 10.7759/cureus.20027