Plastic and Reconstructive Surgery.... May 2024Implant-based breast reconstruction after nipple-sparing mastectomy (NSM) presents unique benefits and challenges. The literature has compared outcomes among total...
BACKGROUND
Implant-based breast reconstruction after nipple-sparing mastectomy (NSM) presents unique benefits and challenges. The literature has compared outcomes among total submuscular (TSM), dual-plane (DP), and prepectoral (PP) planes; however, a dedicated meta-analysis relevant to NSM is lacking.
METHODS
We conducted a systematic review of studies on immediate breast reconstruction after NSM using TSM, DP, or PP prosthesis placement in PubMed, Embase, and Cochrane databases. In total, 1317 unique articles were identified, of which 49 were included in the systematic review and six met inclusion criteria for meta-analysis. Pooled descriptive outcomes were analyzed for each cohort for all 49 studies. Fixed-effects meta-analytic methods were used to compare PP with subpectoral (TSM and DP) reconstructions.
RESULTS
A total of 1432 TSM, 1546 DP, and 1668 PP reconstructions were identified for descriptive analysis. Demographics were similar between cohorts. Pooled descriptive outcomes demonstrated overall similar rates of reconstructive failure (3.3%-5.1%) as well as capsular contracture (0%-3.9%) among cohorts. Fixed-effects meta-analysis of six comparative studies demonstrated a significantly lower rate of mastectomy flap necrosis in the PP cohort compared with the subpectoral cohort (relative risk 0.24, 95% confidence interval [0.08-0.74]). All other consistently reported outcomes, including, hematoma, seroma, infection, mastectomy flap necrosis, nipple -areola complex necrosis, and explantation were comparable.
CONCLUSIONS
A systematic review of the literature and meta-analysis demonstrated the safety of immediate prepectoral breast reconstruction after NSM, compared with submuscular techniques. Submuscular reconstruction had a higher risk of mastectomy flap necrosis, though potentially influenced by selection bias.
PubMed: 38746948
DOI: 10.1097/GOX.0000000000005808 -
Current Problems in Cardiology Aug 2024Despite recent advancements, challenges persist in determining the optimal stenting strategy for LM bifurcation disease. Hence, this systematic review aims to compare... (Meta-Analysis)
Meta-Analysis Comparative Study Review
Despite recent advancements, challenges persist in determining the optimal stenting strategy for LM bifurcation disease. Hence, this systematic review aims to compare single provisional and systematic dual stenting for managing LM bifurcation disease. A systematic search was performed until January 14, 2024. For the effect measure, risk ratios (RRs) was calculated. This study included 22 studies with 10776 participants. The all-cause mortality and cardiovascular mortality revealed comparable outcomes between provisional and dual-systematic stenting (RR 1.13, CI95 %: 0.87-1.47, p 0.36, I 59 %; RR 1.16, CI95 %: 0.73-1.84, p 0.63, I 80 %). In addition, MACE, MI, TLR, TVR, and in stent thrombosis also showed similar findings. Subgroup analysis revealed that cohort studies was the source of heterogeneity in all-cause mortality, stent thrombosis, and TLR. This meta-analysis suggests comparable outcomes between provisional and dual-systematic stenting in managing LM bifurcation disease. Further study is needed to validate the outcomes of novel techniques.
Topics: Humans; Coronary Artery Disease; Percutaneous Coronary Intervention; Stents; Drug-Eluting Stents; Treatment Outcome
PubMed: 38744356
DOI: 10.1016/j.cpcardiol.2024.102633 -
Current Problems in Cardiology Jul 2024The ideal surgical intervention for secondary mitral regurgitation (SMR), a disease of the left ventricle not the mitral valve itself, is still debated. We performed an... (Meta-Analysis)
Meta-Analysis Comparative Study Review
Long-term outcomes comparison of mitral valve repair or replacement for secondary mitral valve regurgitation. An updated systematic review and reconstructed time-to-event study-level meta-analysis.
BACKGROUND AND AIM
The ideal surgical intervention for secondary mitral regurgitation (SMR), a disease of the left ventricle not the mitral valve itself, is still debated. We performed an updated systematic review and study-level meta-analysis investigating mitral valve repair (MVr) versus mitral valve replacement (MVR) for adult patients with SMR, with or without coronary artery disease (CAD).
METHODS
PubMed, CENTRAL and EMBASE were searched for studies comparing MVr versus MVR. Randomized trial or observational studies were considered eligible. Primary endpoint was long-term mortality for any cause. Kaplan-Meier survival curves were reconstructed and compared with Cox linear regression. Landmark analysis and time-varying hazard ratio (HR) were analyzed. Sensitivity analyses included meta-regression and separate sub-analysis. A random effects model was used.
RESULTS
Twenty-three studies (MVr=3,727 and MVR=2,839) were included. One study was a randomized trial, and 19 studies were adjusted. The mean weighted follow-up was 3.7±2.8 years. MVR was associated with significative greater late mortality (HR=1.26; 95 % CI, 1.14-1.39; P<0.0001) at 10-year follow-up. There was a time-varying trend showing an increased risk of mortality in the first 2 years after MVR (HR=1.38; 95 % CI, 1.21-1.56; P<0.0001), after which this difference dissipated (HR=0.94; 95 % CI, 0.81-1.09; P=0.41). Separate sub-analyses showed comparable long-term mortality in patients with concomitant coronary surgery ≥90 %, left ventricle ejection fraction ≤40 %, and sub-valvular apparatus preservation rate of 100 %.
CONCLUSIONS
Compared to repair, MVR is associated with higher probability of mortality in the first 2 years following surgery, after which the two procedures showed comparable late mortality rate.
Topics: Humans; Mitral Valve Insufficiency; Heart Valve Prosthesis Implantation; Mitral Valve; Treatment Outcome; Mitral Valve Annuloplasty; Time Factors
PubMed: 38735348
DOI: 10.1016/j.cpcardiol.2024.102636 -
Journal of Dentistry Jul 2024This systematic review evaluated the occlusal changes after loading with implant-supported single crowns. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
This systematic review evaluated the occlusal changes after loading with implant-supported single crowns.
SOURCES
An electronic literature search was conducted in PubMed, Embase and Cochrane library for randomized (RCTs) or non-randomized controlled clinical trials (CCTs), with a minimum of 10 patients.
STUDY SELECTION
Studies reporting the occlusal force changes on implant-supported single crowns - with natural teeth as antagonist - measured at baseline and after loading periods were included. 4 CCTs including 133 ISCs in posterior sites were included for meta-analysis. All analyzed ISCs had no contact at a light bite and a light contact at a heavy bite in MIP at loading (baseline).
DATA
The relative occlusal forces (ROFs) of each implant-supported single crown (ISC) or control tooth (CT) were extracted. ROFs were defined as percentage of the total occlusal force of the entire dentition at maximum intercuspal position (MIP). A meta-analysis was conducted to compare the ROF changes at different follow-up periods and the weighted mean differences in ROF between ISCs and CTs were pooled and analyzed. The amount of change in ROF was significantly lower in 6 to 12 months after loading comparing the follow-up period between baseline and 6 month (p < 0.05). At baseline and 3-month follow-up, CTs presented significant higher ROF than ISCs (p < 0.05), while no significant difference was found after half year following.
CONCLUSIONS
This study showed that the ROF changes significantly over time after loading of ISCs. It might prove that the occlusal concept defined at the time of prosthetic delivery changes or adapts naturally over time.
CLINICAL SIGNIFICANCE
The function of specific implant occlusal concept (no contact at a light bite and a light contact at a heavy bite in MIP) is limited over time and careful monitoring and occlusal adjustments should be recommendable during the first-year follow-up.
Topics: Humans; Crowns; Bite Force; Dental Prosthesis, Implant-Supported; Dental Implants, Single-Tooth; Follow-Up Studies; Dental Occlusion
PubMed: 38734300
DOI: 10.1016/j.jdent.2024.105000 -
BMC Musculoskeletal Disorders May 2024This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or... (Meta-Analysis)
Meta-Analysis
BACKGROUND
This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation.
METHODS
The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected.
RESULTS
Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score.
CONCLUSION
In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique.
TRIAL REGISTRATION
The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).
Topics: Humans; Bone Plates; Shoulder Fractures; Fracture Fixation, Internal; Bone Cements; Aged; Treatment Outcome; Aged, 80 and over; Postoperative Complications; Reoperation
PubMed: 38730497
DOI: 10.1186/s12891-024-07502-1 -
Translational Andrology and Urology Apr 2024Penile prosthetic devices are the standard treatment for erectile dysfunction (ED) after failure of maximum medical therapy and conservative options. Several penile... (Review)
Review
BACKGROUND
Penile prosthetic devices are the standard treatment for erectile dysfunction (ED) after failure of maximum medical therapy and conservative options. Several penile lengthening procedures (PLPs) can be performed concurrently with penile prosthesis (PP) insertion in patients with severe ED, penile shortening, and/or Peyronie's disease to help combat negative emotional and psychological concerns from penile length loss with penile prosthetic device placement.
METHODS
An extensive, systematic literature review of the various pre-, intra-, and post-operative techniques that can be applied to preserve, restore or enhance penile length at the time of penile prosthetic implantation.
RESULTS
Numerous pre-operative and post-operative inflation protocols exists with vacuum erection devices and penile traction therapy. Intraoperative surgical techniques include cavernosal sparing and channeling without dilatation, subcoronal incision with circumferential penile degloving and grafting, the sliding technique, the modified sliding technique, the multiple-slit technique, the tunical expansion procedure (TEP), modified TEP, and the auxetic expansion procedure. These approaches can be meaningful to restore and/or preserve length for patients undergoing PP insertion.
CONCLUSIONS
PLPs can be performed by surgeons who have extensive penile reconstruction experience and have been trained to do these procedures, as there is significant risk to the patient and limitations to what can be expected. Each patient must be counseled in detail about the risks and benefits of these procedures and have their expectations managed as the average postoperative penile length recovery is around 3 cm and can range from 0-4.0 cm. Future research is needed to identify the appropriate candidate for each approach, and how much length gain the patient can expect.
PubMed: 38721300
DOI: 10.21037/tau-23-354 -
Translational Andrology and Urology Apr 2024Priapism is a rare condition characterized by persistent erection of the penis that lasts more than 4 hours in the absence of sexual stimulation and is associated with... (Review)
Review
BACKGROUND
Priapism is a rare condition characterized by persistent erection of the penis that lasts more than 4 hours in the absence of sexual stimulation and is associated with significant morbidity and complications, including erectile dysfunction and penile fibrosis. Surgical management of priapism can be extremely challenging. We herein provide a comprehensive review that aims to evaluate the role of penile prosthesis (PP) implantation in the management of priapism.
METHODS
A systematic literature search was performed using the following databases: PubMed, Embase, and Scopus to identify studies that evaluated the effectiveness of PP implantation in treating priapism and the long-term complications, outcomes, and patients' satisfaction rate.
RESULTS
Out of 717 English-language studies published between 2002 and 2022, 17 were chosen for this review. Majority of patients had a malleable PP (MPP) implant, either early or delayed after the priapism episode. Early placement (EP) of PP is widely defined between studies ranging from less than 72 hours, within 1 week, and within 3 weeks. Most common causes of priapism were sickle cell anemia (SCA), medication-induced, and idiopathic. Studies show a higher satisfaction rate ranging between 80% and 100%, with sexual intercourse achievement ranging between 64.2% and 100%. Based on the GRADE system, included studies rated as very low quality of evidence. Commonly reported complications that arise after PP procedures, include device infection, erosion, curvature, and mechanical malfunction, such as auto-inflation.
CONCLUSIONS
PP can be an effective treatment option for priapism, particularly in cases of ischemic priapism lasting more than 36 hours or recurrent priapism that is medically refractory. However, due to the very low quality of evidence, larger, well-designed studies are warranted where long-term outcomes, patients' satisfaction, and complications following priapism-related PP implantation are measured as endpoints.
PubMed: 38721288
DOI: 10.21037/tau-23-224 -
BMC Cardiovascular Disorders May 2024Cerebral malperfusion (CM) is a common comorbidity in acute type A aortic dissection (ATAAD), which is associated with high mortality and poor neurological prognosis.... (Meta-Analysis)
Meta-Analysis
Two surgical strategies (early carotid reperfusion vs. Central aortic repair-first) of acute type a aortic dissection complicated with cerebral malperfusion syndrome: a meta-analysis and systematic review.
OBJECTIVE
Cerebral malperfusion (CM) is a common comorbidity in acute type A aortic dissection (ATAAD), which is associated with high mortality and poor neurological prognosis. This meta-analysis investigated the surgical strategy of ATAAD patients with CM, aiming to compare the difference in therapeutic effectiveness between the central repair-first and the early reperfusion-first according to clinical outcomes.
METHODS
The meta-analysis and systematic review was conducted based on studies sourced from the PubMed, Embase, and Cochrane literature database, in which cases of ATAAD with CM underwent surgical repair were included. Data for baseline characteristics, mortality, survival were extracted, and risk ratio (RR) values and the pooled mortality were calculated.
RESULTS
A total of 17 retrospective studies were analyzed, including 1010 cases of ATAAD with CM underwent surgical repair. The pooled early mortality in early reperfusion group was lower (8.1%; CI, 0.02 to 0.168) than that in the central repair group (16.2%; CI, 0.115 to 0.216). The pooled long-term mortality was 7.9% in the early reperfusion cohort and 17.4% the central repair-first cohort, without a statistically significant heterogeneity (I [2] = 51.271%; p = 0.056). The mean time of symptom-onset-to-the-operation-room in all the reports was 8.87 ± 12.3 h.
CONCLUSION
This meta-analysis suggested that early reperfusion-first may achieved better outcomes compared to central repair-first in ATAAD patients complicated with CM to some extent. Early operation and early restoration of cerebral perfusion may reduce the occurrence of some neurological complications.
TRIAL REGISTRATION
The meta-analysis was registered in the International Prospective Register of Systematic Reviews database (No. CRD CRD42023475629) on Nov. 8th, 2023.
Topics: Humans; Aortic Dissection; Treatment Outcome; Cerebrovascular Circulation; Risk Factors; Time Factors; Aortic Aneurysm; Female; Male; Middle Aged; Aged; Acute Disease; Cerebrovascular Disorders; Adult; Blood Vessel Prosthesis Implantation; Risk Assessment; Reperfusion; Time-to-Treatment
PubMed: 38714966
DOI: 10.1186/s12872-024-03910-2 -
Dental Materials : Official Publication... Jun 2024Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental implants is electrochemical anodization, which may generate a nanotubular surface (TiO nanotubes) with antibacterial potential and osteoinductive features. This systematic review and meta-analysis aims to elucidate the possible antibacterial properties of the surface in question compared to the untreated titanium surface.
SOURCES
For that purpose, was performed a systematic search on the bases PubMed, Lilacs, Embase, Web Of Science, Cinahl, and Cochrane Central, as well as, manual searches and gray literature.
STUDY SELECTION
The searches resulted in 742 articles, of which 156 followed for full-text reading. Then, 37 were included in the systematic review and 8 were included in meta-analysis.
RESULTS
Fifteen studies revealed significant antibacterial protection using TiO nanotube surfaces, while 15 studies found no statistical difference between control and nanotextured surfaces. Meta-analysis of in vitro studies demonstrated relevant bacterial reduction only for studies investigating Staphylococcus aureus in a period of 6 h. Meta-analysis of in vivo studies revealed three times lower bacterial adhesion and proliferation on TiO nanotube surfaces.
CONCLUSIONS
TiO nanotube topography as a surface for dental implants in preclinical research has demonstrated a positive relationship with antibacterial properties, nevertheless, factors such as anodization protocols, bacteria strains, and mono-culture methods should be taken into consideration, consequently, further studies are necessary to promote clinical translatability.
Topics: Titanium; Nanotubes; Dental Implants; Surface Properties; Anti-Bacterial Agents; Bacterial Adhesion; Humans; Staphylococcus aureus
PubMed: 38714394
DOI: 10.1016/j.dental.2024.04.009 -
Forensic Science International Jun 2024Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions.
METHODS
A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I statistic was used to assess heterogeneity.
RESULTS
A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases.
CONCLUSIONS
Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.
Topics: Humans; Arrhythmias, Cardiac; Defibrillators, Implantable; Equipment Failure; Pacemaker, Artificial; Cause of Death; Guidelines as Topic; Autopsy
PubMed: 38714107
DOI: 10.1016/j.forsciint.2024.112001