International Journal of Ophthalmology 2024To compare the efficacy of pars plana vitrectomy (PPV) combined with internal limiting membrane (ILM) and silicone oil or sterile air tamponade for the treatment of...
AIM
To compare the efficacy of pars plana vitrectomy (PPV) combined with internal limiting membrane (ILM) and silicone oil or sterile air tamponade for the treatment of myopic foveoschisis (MF) in highly myopic eyes.
METHODS
This retrospective study included 48 myopic eyes of 40 patients with MF and axial lengths (ALs) ranging from 26-32 mm treated between January 2020 and January 2022. All patients were underwent PPV combined with ILM peeling followed by sterile air or silicone oil tamponade and followed up at least 12mo. Based on the features on spectral-domain optical coherence tomography (SD-OCT), the eyes were divided into the MF-only group (Group A, =15 eyes), MF with central foveal detachment group (Group B, =20 eyes), and MF with lamellar macular hole group (Group C, =13 eyes). According to AL, eyes were further divided into three groups: Group D (26.01-28.00 mm, =12 eyes), Group E (28.01-30.00 mm, =26 eyes), and Group F (30.01-32.00 mm, =10 eyes). The best-corrected visual acuity (BCVA), central foveal thickness (CFT), and complications were recorded.
RESULTS
The patients included 16 males and 24 females with the mean age of 56±9.82y. The BCVA and CFT improved in all groups after surgery (<0.01), while there was no significant difference of the CFT in Group A, B, and C postoperatively (>0.05). The intergroup differences of BCVA and CFT postoperatively were statistically significant in Group D, E, and F. Twenty eyes were injected with sterile air, and 28 eyes were injected with silicone oil for tamponade based on the AL. However, there was no statistically significant difference among Groups D, E, and F in terms of the results of sterile air or silicone oil tamponade. The mean recovery time was 5.9mo for MF patients subjected to silicone oil tamponade and 7.7mo for patients subjected to sterile air tamponade, and the difference was not statistically significant.
CONCLUSION
PPV and ILM peeling combined with silicone oil or sterile air tamponade can achieve good results for MF in highly myopic eyes with ALs≤32 mm.
PubMed: 38895672
DOI: 10.18240/ijo.2024.06.13 -
RSC Advances Jun 2024Borohydride crossover in anion exchange membrane (AEM) based direct borohydride fuel cells (DBFCs) impairs their performance and induces cathode catalyst poisoning. This...
Borohydride crossover in anion exchange membrane (AEM) based direct borohydride fuel cells (DBFCs) impairs their performance and induces cathode catalyst poisoning. This study evaluates three non-precious metal catalysts, namely LaMnCoO (LMCO) perovskite, MnCoO (MCS) spinel, and Fe-N-C, for their application as cathode catalysts in DBFCs. The rotating disk electrode (RDE) testing shows significant borohydride tolerance of MCS. Moreover, MCS has exhibited exceptional stability in accelerated durability tests (ADTs), with a minimal reduction of 10 mV in half-wave potential. DFT calculations further reveal that these catalysts predominantly adsorb over , unlike commercial Pt/C which preferentially adsorbs . In DBFCs, MCS can deliver a peak power density of 1.5 W cm, and a 3% voltage loss after a 5 hours durability test. In contrast, LMCO and Fe-N-C have exhibited significantly lower peak power density and stability. The analysis of the TEM, XRD, and XPS results before and after the single-cell stability tests suggests that the diminished stability of LMCO and Fe-N-C catalysts is due to catalyst detachment from carbon supports, resulting from the nanoparticle aggregation during the high-temperature preparation process. Such findings suggest that MCS can effectively mitigate the fuel crossover challenge inherent in DBFCs, thus enhancing its viability for practical application.
PubMed: 38895534
DOI: 10.1039/d4ra02767a -
Materials (Basel, Switzerland) May 2024In this paper, the stress-strain curves of TiAlNb are established based on uniaxial impact tests over wide ranges of temperature and strain rate. The TiAlNb exhibited...
In this paper, the stress-strain curves of TiAlNb are established based on uniaxial impact tests over wide ranges of temperature and strain rate. The TiAlNb exhibited the work hardening effect but did not show an obvious yield stage during a quasi-static compression test. In the SHPB test, an obvious temperature softening effect was found, the strain rate strengthening effect was detected when the strain rate was 4000-8000 s, and the strain rate softening effect was detected in the range of 8000-12,000 s. A function describing the effect of strain rate on the strain rate strengthening parameters under various temperatures was proposed to modify the basic J-C constitutive model. The relative errors between the experimental measured value and predicted values in various experimental conditions with a modified J-C model were less than 5.0%. The results verified that the modified J-C model could accurately describe the dynamic mechanical properties of TiAlNb at high temperatures and strain rates. The research could help to illustrate the cutting mechanism and finite element simulation of TiAlNb alloy.
PubMed: 38893836
DOI: 10.3390/ma17112572 -
Materials (Basel, Switzerland) May 2024Traditional ACSR overhead wires, which consist of a high-strength steel core and several layers of aluminium wires, are currently the most popular overhead line...
Traditional ACSR overhead wires, which consist of a high-strength steel core and several layers of aluminium wires, are currently the most popular overhead line conductor (OHL) design globally. Operating conditions, particularly operating under varying stresses from Karman vortices, lead to the fatigue cracking of wires of the outer layer, followed by wires of the inner layers. Karman vortices are formed by the detachment of a laminar wind stream flowing around the conductor, which causes vibrations in the conductor called wind or aeolian oscillations. Aluminium wires are manufactured using standard batch material drawing technology. Although the fatigue strength of such wires is not standardised, there are various criteria for evaluating this characteristic, as well as established limits on the number of cycles needed to break the first wires of the outer layer. Fatigue strength also strongly depends on the geometric structure of the wire and its operating conditions. The article analyses the influence of the mechanical condition of aluminium wires used in ACSR cables on their fatigue strength. We then present results from aluminium wire fatigue tests conducted on a specially constructed test rig. In addition, fatigue cracks were interpreted using scanning microscopy.
PubMed: 38893802
DOI: 10.3390/ma17112537 -
Diagnostics (Basel, Switzerland) May 2024In the original publication [...].
Correction: Díaz-Aljaro et al. Quantitative Microvascular Change Analysis Using a Semi-Automated Algorithm in Macula-on Rhegmatogenous Retinal Detachment Assessed by Swept-Source Optical Coherence Tomography Angiography. 2024, , 750.
In the original publication [...].
PubMed: 38893733
DOI: 10.3390/diagnostics14111107 -
Journal of Clinical Medicine May 2024: Swept-source anterior segment optical coherence tomography (SS-AS-OCT) is a suitable examination for the vitreolenticular interface. : In a prospective study using...
: Swept-source anterior segment optical coherence tomography (SS-AS-OCT) is a suitable examination for the vitreolenticular interface. : In a prospective study using Anterion (Heidelberg Engineering, Heidelberg, Germany), 102 eyes of 102 patients were examined in pupil dilation, preoperatively and 6 times over 1-year follow-up. Preoperatively anterior hyaloid membrane (AHM) visibility was determined with Imaging App with high reliability. Postoperatively capsular bag-AHM distance was measured on six points by using Metrics App. : The AHM was visible in 18.6% preoperatively and postoperatively as well (Group 1), 49% of the preoperatively adherent AHMs became visible (Group 2A), 32.4% remained attached (Group 2B). Group 1: the average deepest point on the first day was 782.5 ± 324.1 microns, and it significantly differed from the later follow-up values. Group 2A: the average deepest value was 184.1 ± 220.1 microns, and there was no statistically significant difference between the postoperative visit values. The difference between the groups was statistically significant at every location and at each time point. : AS-SS-OCT can be used to check BS both preoperatively (with limitations) and postoperatively.
PubMed: 38892935
DOI: 10.3390/jcm13113219 -
Journal of Clinical Medicine May 2024Ophthalmic three-dimensional (3D) digital surgery can reproduce high-definition surgical images; however, 3D digital surgery is limited by recording capacities. We...
Ophthalmic three-dimensional (3D) digital surgery can reproduce high-definition surgical images; however, 3D digital surgery is limited by recording capacities. We examined the relationship between the minimum image quality required to reproduce surgical images and recording capacity. Patients who underwent simultaneous vitrectomy and cataract surgery by the same surgeon using a 3D digital surgery system at Juntendo University Urayasu Hospital between February and October 2021 were evaluated. Various quality (Q) and frame rate (FR) settings were used for each case. Four vitreous surgeons evaluated the reproducibility of recorded images of macular manipulation for epiretinal membrane (ERM) and macular hole (MH) cases and those of peripheral retinal manipulation for rhegmatogenous retinal detachment (RRD) cases. The video bitrate and minimum settings required to reproduce surgical images and factors affecting surgical image reproducibility were examined. A total of 129 eyes of 129 patients were observed. The minimum image quality required to reproduce surgical images was 11.67 Mbps. The Q and FR for periretinal processing and Q for macular manipulation affected surgical image reproducibility ( = 0.025, = 0.019, and = 0.07, respectively). The minimum recording settings required to obtain highly reproducible images were Q = 3 and FR = 40. The total file size for vitrectomy video recordings with these settings was as compact as 3.17 GB for 28 min. During 3D digital surgery, highly reproducible surgical images can be obtained with a small storage capacity using settings of at least Q = 3 and FR = 40.
PubMed: 38892762
DOI: 10.3390/jcm13113051 -
International Journal of Molecular... May 2024Approximately 30% of steroid-resistant nephrotic syndromes are attributed to monogenic disorders that involve 27 genes. Mutations in family members have also been...
Approximately 30% of steroid-resistant nephrotic syndromes are attributed to monogenic disorders that involve 27 genes. Mutations in family members have also been linked to nephrotic syndrome; however, the precise mechanism remains elusive. To investigate this, podocyte-specific knockout mice were generated to examine phenotypic changes. In the initial assessment under normal conditions, knockout mice showed no significant differences in the urinary albumin-creatinine ratio, blood urea nitrogen, serum creatinine levels, or histological features compared to controls. However, following kidney injury with adriamycin, podocyte-specific knockout mice exhibited a significantly higher albumin-creatinine ratio and a significantly greater sclerotic index than control mice. Electron microscopy revealed more extensive foot process effacement in the knockout mice than in control mice. In addition, -deficient human podocytes showed increased detachment and apoptosis following adriamycin exposure. These findings suggest that KANK1 may play a protective role in mitigating podocyte damage under pathological conditions.
Topics: Podocytes; Animals; Mice; Humans; Mice, Knockout; Doxorubicin; Cytoskeletal Proteins; Adaptor Proteins, Signal Transducing; Apoptosis; Nephrotic Syndrome; Male; Tumor Suppressor Proteins
PubMed: 38891998
DOI: 10.3390/ijms25115808 -
International Journal of Molecular... May 2024Anoikis, a form of apoptosis resulting from the loss of cell-extracellular matrix interaction, is a significant barrier to cancer cell metastasis. However, the...
Anoikis, a form of apoptosis resulting from the loss of cell-extracellular matrix interaction, is a significant barrier to cancer cell metastasis. However, the epigenetic regulation of this process remains to be explored. Here, we demonstrate that the histone deacetylase sirtuin 6 (SIRT6) plays a pivotal role in conferring anoikis resistance to colorectal cancer (CRC) cells. The protein level of SIRT6 is negatively correlated with anoikis in CRC cells. The overexpression of SIRT6 decreases while the knockdown of SIRT6 increases detachment-induced anoikis. Mechanistically, SIRT6 inhibits the transcription of N-myc downstream-regulated gene 1 (), a negative regulator of the AKT signaling pathway. We observed the up-regulation of SIRT6 in advanced-stage CRC samples. Together, our findings unveil a novel epigenetic program regulating the anoikis of CRC cells.
Topics: Humans; Anoikis; Colorectal Neoplasms; Sirtuins; Gene Expression Regulation, Neoplastic; Cell Cycle Proteins; Cell Line, Tumor; Intracellular Signaling Peptides and Proteins; Down-Regulation; Signal Transduction; Epigenesis, Genetic
PubMed: 38891773
DOI: 10.3390/ijms25115585 -
Polymers May 2024The immobilization of gold nanoparticle (AuNP) linear surface assemblies on polycarbonate (PC) melt surface via molding is investigated. The order of the particle...
The immobilization of gold nanoparticle (AuNP) linear surface assemblies on polycarbonate (PC) melt surface via molding is investigated. The order of the particle assemblies is preserved during the molding process. The assemblies on PC exhibit plasmonic coupling features and dichroic properties. The structure of the assemblies is quantified based on Scanning Electron Microscopy (SEM) and image analysis data using an orientational order parameter. The transfer process from mold to melt shows high structural fidelity. The order parameter of around 0.98 reflects the orientation of the lines and remains unaffected, independent of the injection direction of the melt relative to the particle lines. This is discussed in the frame of fountain flow during injection molding. The particles were permanently fixed and withstood the injection molding process, detachment of the substrate, and extraction in boiling ethanol. The plasmonic particles coupled strongly within the dense nanoparticle lines to produce anisotropic optical properties, as quantified by dichroic ratios of 0.28 and 0.52 using ultraviolet-visible-near-infrared (UV-Vis-NIR) spectroscopy. AuNP line assemblies on a polymer surface may be a basis for plasmonic devices like surface-enhanced Raman scattering (SERS) sensors or a precursor for nanowires. Their embedding via injection molding constitutes an important link between particle-self-assembly approaches for optically functional surfaces and polymer processing techniques.
PubMed: 38891499
DOI: 10.3390/polym16111553