Frontiers in Pediatrics 2023This review evaluates the safety and efficacy of submuscular plating (SMP) vs. elastic stable intramedullary nailing (ESIN) in the treatment of pediatric femur shaft... (Review)
Review
OBJECTIVES
This review evaluates the safety and efficacy of submuscular plating (SMP) vs. elastic stable intramedullary nailing (ESIN) in the treatment of pediatric femur shaft fracture.
METHOD
Studies comparing the efficacy and safety of SMP and ESIN in pediatric shaft fracture were retrieved from five databases (PubMed, Embase, Cochrane, OVID, and Web of Science) from inception to March 2023 using a systematic literature search strategy. A total of 13 outcome measures, such as perioperative parameters, clinical outcomes, and radiographic results, were included in the meta-analysis.
RESULTS
Eight eligible studies involving 491 patients were included in the narrative synthesis. There were no significant differences in baseline characteristics between the two groups. Meta-analysis showed reduced radiation time (RT), soft tissue irritation and angular deformation in the SMP group than in the ESIN group. However, the SMP group had greater estimated blood loss (EBL) than the ESIN group. The duration of surgery, length of hospital stay (LOS), implant removal, complications requiring surgery, Flynn score, incidence of infection, fracture healing time, and limb length discrepancy (LLD) were similar between the two groups. Only one study reported higher incidences of fracture nonunion or delayed healing in the ESIN group.
CONCLUSION
SMP is an effective and safe intervention superior to ESIN in reducing soft tissue irritation, angular deformation and radiation time. Given the presence of potential bias and heterogeneity, surgeons should select the treatment that would provide the best outcomes for EBL, LOS, operation time, and bone nonunion or delayed healing based on their experience.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023404118, Identifier PROSPERO (CRD42021228512).
PubMed: 38027269
DOI: 10.3389/fped.2023.1256630 -
Trauma Surgery & Acute Care Open 2023Clavicle fracture (CF) is the tenth most prevalent fracture, accounting for an annual incidence of 37/10,000. This systematic review highlights the factors contributing...
BACKGROUND
Clavicle fracture (CF) is the tenth most prevalent fracture, accounting for an annual incidence of 37/10,000. This systematic review highlights the factors contributing to the nonunion union of the clavicular fracture.
METHOD
A systematic search was conducted using three web-based databases up to August 12, 2022, for conducting qualitative analysis. Articles were screened for relevance, and only studies that met inclusion criteria based on PECOS; P (patients): participants diagnosed with clavicular fracture; E (exposure): nonunion, C (control): not applicable; O (outcomes): factors contributing to nonunion or delayed union; S (studies): trials and observational studies. The Newcastle-Ottawa Scale was used to assess the quality of the cohort studies. The Cochrane risk of bias tool was used to assess the bias in randomized control trials.
RESULTS
Ten studies were selected after the final literature search. Two thousand seven hundred and sixty-six adult participants who were radiologically and clinically diagnosed with nonunion clavicular fracture were included to pool the qualitative results. Fall was the most dominant cause of clavicular fracture, followed by road traffic collisions. Open reduction was widely used to treat nonunion correction. The qualitative results suggested a prominent correlation of nonunion with advancing age, female gender, high energy trauma, high Disabilities of the Arm, Shoulder, and Hand Score, smoking, fracture displacement, clavicular shortening, the callus on radiography, and fracture movement. The mid-shaft fracture was the most dominant type of fracture in the included studies; highly associated with nonunion in comparison to medial or lateral CF. The previous history of operation was an independent factor contributing to nonunion.
CONCLUSION
The results of this systematic review suggested the predictors contributing to nonunion in the CF. Demographic factors such as advancing age with female gender are at higher risk of developing clavicular nonunion. Smoking was the most dominantly highlighted environmental factor contributing to nonunion. Diaphyseal or midshaft fracture was the most common site for nonunion. Therefore, we suggested that patients with the predictors mentioned above require special attention to prevent nonunion of the CFs. More studies should be conducted on this subject to assess the factors that pose a risk associated with the nonunion of the bone for better clinical management and outcomes of the fracture.
PubMed: 38020862
DOI: 10.1136/tsaco-2023-001188 -
Orthopaedics & Traumatology, Surgery &... May 2024Pyrocarbon promises to be an optimal material choice for radial head arthroplasty (RHA) due to an elastic modulus comparable to the radial diaphysis and thus providing... (Review)
Review
INTRODUCTION
Pyrocarbon promises to be an optimal material choice for radial head arthroplasty (RHA) due to an elastic modulus comparable to the radial diaphysis and thus providing higher biocompatibility. Primary objective was to determine the complications and revision rates related to the usage of these prostheses. The secondary objective was to assess the clinical and radiological outcomes of Pyrocarbon RHAs.
HYPOTHESIS
Pyrocarbon RHAs have good clinical and radiological outcomes with low complications and revisions.
METHODS
Ovid MEDLINE and Embase databases were used to search for studies on outcomes and complications of the RHAs using Pyrocarbon radial head prostheses. The systematic review was designed in accordance with the PRISMA guidelines and included studies were appraised using the MINORS tool. Complications and RHA revision rates were assessed. Functional outcomes were reviewed using PROMs (like MEPI, DASH and BMS), post-op range of motion (using goniometer) and grip strength (using the dynamometer). Postoperative radiological outcomes like peri-prosthetic lucency, radial neck osteolysis, radio-capitellar congruence, capitellar erosion, overstuffing/understuffing and osteoarthritis were reported using radiographs.
RESULTS
A total of 12 studies cumulatively reporting 353 patients who underwent Pyrocarbon RHAs were included in the review. The mean age of patients across the studies ranged from 47 to 54 years of which 50.5% were males. The majority of radial head replacements were done for acute trauma (87.5%) with the remainder done for arthritis (1.7%) and trauma sequelae (10.8%). Mean follow-up period in the selected studies ranged from 18 to 110 months with minimum follow-up across all studies being 12 months. Modular Pyrocarbon (MoPyC, Tornier™) was the implant of choice in ten studies while two studies used the Ascension Pyrocarbon radial head (Ascension Orthopaedics™). Ten studies demonstrated mean MEPI ranging from 75.5 to 96. Mean extension deficit ranged from 6 to 19 degrees, mean flexion from 120 to 140 degrees, mean pronation from 71 to 87 degrees and mean supination from 63 to 85 degrees. Relative grip strength ranged from 69 to 96% of the contralateral limb. Revisions due to implant-related reasons (intra-prosthetic dissociation, prosthetic fracture, peri-prosthetic loosening, radio-capitellar subluxation and understuffed/overstuffed elbow) was 6.8% (24/353). Radial stress shielding and peri-prosthetic lucency was reported in 10 to 100% of patients across different studies but symptomatic implant loosening leading to revision remained rare (2%, 7/353). Radio-capitellar congruence was reported in 81% to 100% cases while capitellar erosion ranged from 0% to 89%. Pyrocarbon implants specific complications included head-neck intra-prosthetic decoupling (1.1%) and pyrocarbon head fractures (0.9%). In total, 5.7% cases underwent re-surgery due to non-RHA related reasons.
DISCUSSION
The pyrocarbon RHA shows good functional outcome, range of motion and low revision rates. This aligns with the working hypothesis of this review. However, pyrocarbon radial head implants have implant-specific complications like pyrocarbon radial head fractures and intra-prosthetic decoupling between stem and head. Despite promising in vitro biomechanical properties, capitellar wear is still a common finding with pyrocarbon RHAs. Despite these factors, pyrocarbon radial head implants are a viable option for radial head arthroplasty.
LEVEL OF EVIDENCE
II; Systematic review.
Topics: Humans; Carbon; Reoperation; Arthroplasty, Replacement, Elbow; Prosthesis Design; Elbow Joint; Radius; Elbow Prosthesis; Range of Motion, Articular; Treatment Outcome
PubMed: 37949394
DOI: 10.1016/j.otsr.2023.103750 -
Journal of Children's Orthopaedics Oct 2023Fractures of the femoral diaphysis are associated with a risk of morbidity in children. Various fixation methods have been developed, but with only limited evidence to... (Review)
Review
Plate fixation versus flexible intramedullary nails for management of closed femoral shaft fractures in the pediatric population: A systematic review and meta-analysis of the adverse outcomes.
PURPOSE
Fractures of the femoral diaphysis are associated with a risk of morbidity in children. Various fixation methods have been developed, but with only limited evidence to support their use. This systematic review assesses the evidence regarding clinical outcomes of closed femoral diaphyseal fractures in children treated with plate fixation or flexible intramedullary nails.
METHODS
A PROSPERO-registered, PRISMA-compliant systematic review and meta-analysis were conducted. MEDLINE, Embase, and Web of Science (WoS) databases were searched from inception to February 2023. Inclusion criteria included clinical studies reporting adverse outcomes following surgical treatment of pediatric closed femoral diaphyseal fractures using plate fixation and flexible intramedullary nails. The ROBINS-I and RoB 2 tools evaluated the risk of bias.
RESULTS
Thirteen papers (2 prospective randomized controlled trials and 11 retrospective cohorts) reported 805 closed diaphyseal femoral fractures in 801 children (559 males, 242 females). There were 360 plate fixations and 445 flexible intramedullary nails. Two cases of osteomyelitis and one nonunion were reported. Meta-analysis showed that plate fixation had a lower risk of soft tissue infection (relative risk 0.26 (95% confidence interval 0.07-0.92)). There was no difference in the following outcomes: malunion (relative risk 0.68 (95% confidence interval 0.32-1.44)); unplanned reoperation (relative risk 0.59 (95% confidence interval 0.31-1.14)), and leg-length difference (relative risk 1.58 (95% confidence interval 0.66-3.77)). The risk of bias was high in all studies.
CONCLUSIONS
An analysis of 805 fractures with minimal differences in meta-analyses is considered high quality even when the quality of the evidence is low. The findings are limited by important flaws in the methodology in the published literature. Well-designed multicentre prospective studies using standardized core outcomes are required to advise treatment recommendations.
LEVEL OF EVIDENCE
III.
PubMed: 37799319
DOI: 10.1177/18632521231190713 -
Medicine Sep 2023Wrist pain on the ulnar side is often caused by ulnar impaction syndrome (UIS). Idiopathic UIS requires surgical treatment when conservative treatment fails. The 2 main... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Wrist pain on the ulnar side is often caused by ulnar impaction syndrome (UIS). Idiopathic UIS requires surgical treatment when conservative treatment fails. The 2 main surgical procedures used are the wafer procedure and ulnar shortening osteotomy (USO) of the metaphysis or diaphysis. This review aimed to analyze comparative studies of the 2 procedures in UIS to determine clinical outcomes and complications.
METHODS
One prospective and 5 retrospective comparison trials were retrieved from the PubMed, Embase, and Cochrane Library databases. The primary outcomes were treatment effectiveness; pain visual analog scale (VAS), disabilities of the arm, shoulder, and hand (DASH) score, Mayo wrist, and Darrow scores. The incidence of postoperative complications formed the secondary outcome.
RESULTS
The selected studies included 107 patients who underwent the wafer procedure (G1) and 117 patients who underwent USO (G2). The wafer procedure had the benefits of less postoperative immobilization and an early return to work. However, there were no significant differences in the postoperative pain improvement and functional scores. All 6 studies reported high total complication rates and reoperation with USO. The most frequent complication was implant-related discomfort or irritation; subsequent plate removal was the most common reason for a secondary operation.
CONCLUSIONS
There was no difference in pain improvement or the postoperative functional score between the groups. Nevertheless, postoperative complications were the major pitfalls of USO. As the specialized shortening system advances further, a high-level study will be necessary to determine the surgical option in UIS.
Topics: Humans; Retrospective Studies; Prospective Studies; Joint Diseases; Wrist Joint; Osteotomy; Treatment Outcome; Arthralgia; Postoperative Complications
PubMed: 37773809
DOI: 10.1097/MD.0000000000035141 -
Archives of Orthopaedic and Trauma... Sep 2023Prosthetic joint infection (PJI) is a destructive complication of knee replacement surgery (KR). In two-stage revision a spacer is required to maintain limb length and... (Review)
Review
INTRODUCTION
Prosthetic joint infection (PJI) is a destructive complication of knee replacement surgery (KR). In two-stage revision a spacer is required to maintain limb length and alignment and provide a stable limb on which to mobilise. Spacers may be articulating or static with the gold standard spacer yet to be defined. The aims of this scoping review were to summarise the types of static spacer used to treat PJI after KR, their indications for use and early complication rates.
METHODS
We conducted a scoping review based on the Joanna Briggs Institute's "JBI Manual for Evidence Synthesis" Scoping review reported following Preferred Reporting Items for Systematic Review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist. MEDLINE, EMBASE and CINAHL were searched from 2005 to 2022 for studies on the use of static spacers for PJI after KR.
RESULTS
41 studies (1230 patients/knees) were identified describing 42 static spacer constructs. Twenty-three (23/42 [54.2%]) incorporated cement augmented with metalwork, while nineteen (19/42, [45.9%]) were made of cement alone. Spacers were most frequently anchored in the diaphysis (22/42, [53.3%]), particularly in the setting of extensive bone loss (mean AORI Type = F3/T3; 11/15 studies 78.3% diaphyseal anchoring). 7.1% (79 of 1117 knees) of static spacers had a complication requiring further surgery prior to planned second stage with the most common complication being infection (86.1%).
CONCLUSIONS
This study has summarised the large variety in static spacer constructs used for staged revision KR for PJI. Static spacers were associated with a high risk of complications and further work in this area is required to improve the quality of care in this vulnerable group.
Topics: Humans; Treatment Outcome; Reoperation; Knee Joint; Arthroplasty, Replacement, Knee; Prostheses and Implants; Arthritis, Infectious; Prosthesis-Related Infections; Anti-Bacterial Agents; Knee Prosthesis; Retrospective Studies
PubMed: 37160445
DOI: 10.1007/s00402-023-04893-z