PloS One 2024Weber Type B fractures often arise from external rotation with the foot supinated or pronated. Altered tibiofibular joint kinematics in Weber B fractures are responsible...
Weber Type B fractures often arise from external rotation with the foot supinated or pronated. Altered tibiofibular joint kinematics in Weber B fractures are responsible for syndesmotic damage seen in Weber B fractures. Weber B fractures are managed using open reduction and internal fixation if displaced. The syndesmosis is injured in up to 40% of cases resulting in an unstable injury with a syndesmotic diastasis. This systematic review aimed to evaluate the current literature on syndesmotic fixation in Weber B fractures, assess the outcomes and complications of syndesmotic fixation and assess the necessity of syndesmotic fixation in Weber B fractures. A search was carried out on the EMBASE, PubMed and CINAHL databases and eight studies assessing the outcomes of syndesmotic fixations versus no syndesmotic fixation with 292 Weber B ankle fractures were included in this systematic review. Results showed significant heterogeneity so a narrative review was conducted. Results of these studies showed that functional, radiological, and quality-of-life outcomes and incidences of post-traumatic osteoarthritis in patients with syndesmotic screws were similar to those of patients not managed with syndesmotic screws. Only one favoured syndesmotic fixation in all cases of diastasis. As such, syndesmotic fixation with screws may not be necessary in the management of Weber B fractures. Screws are also associated with breakage, loosening, local irritation and infections. Suture button devices and antiglide fixation techniques appear to be valid alternatives to syndesmotic screws. It was found that there was no need for routine hardware removal unless the hardware was causing significant side effects for the patient.
Topics: Humans; Ankle Fractures; Fracture Fixation, Internal; Ankle Injuries; Ankle Joint; Bone Screws; Treatment Outcome
PubMed: 38857233
DOI: 10.1371/journal.pone.0304148 -
European Review For Medical and... May 2024Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or environmental factors that modify buccal eutrophism. In daily clinical practice, an increase in the prevalence of PI (8%) determined the need to establish the PI causes and set optimal therapeutic strategies. The interleukin family (IL-1), a group of cytokines, triggers and perpetuates peri-implantitis. Therefore, they could be used as biomarkers for diagnosis and treatment. This systematic review aimed to analyze the correlation between IL-1 allelic polymorphism (IL-1A -889, IL-1β -511, IL-1β +3954) and the PI disease.
MATERIALS AND METHODS
Selected databases were PubMed, Scopus, and Cochrane Library. The search strategy included the following terms: "dental implants"; "periimplantitis"; "interleukin-IL-1"; "polymorphism"; "perimplant bone loss". Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. A meta-analysis was conducted on five of 40 review articles. p-values, confidence intervals (CI), and Odds ratios (OR) were assessed. In 4 articles, the p-value was lower than 0.05, confirming the statistical significance of the result.
RESULTS
The prevalence of the selected studies reported the existence of a causal association between polymorphisms of IL-1 and the onset of peri-implantitis, especially for IL-1 allelic variants associated with further polymorphic genes encoding for IL-6, tumor necrosis factor-alpha (TNF-α), matrix metalloproteinases (MMP)-8, IL-1Na, IL-8, IL-18, osteopontin (OPN). In addition, the presence of the IL-1 polymorphism and PI is particularly higher in smokers, diabetes, and autoimmune disease patients.
CONCLUSIONS
The detection of salivary biomarkers is, therefore, a diagnostic tool with a high potential to intercept the PI early and act with appropriate and non-invasive treatment. Due to the continued technological innovation in biomarkers and diagnostic sciences, further studies are needed to investigate the role of these biochemical mediators. The results of studies and the recent technological innovation in biomarkers and diagnostic sciences will allow further research to investigate the role of these biochemical mediators.
Topics: Humans; Peri-Implantitis; Polymorphism, Genetic; Interleukin-1; Dental Implants
PubMed: 38856132
DOI: 10.26355/eurrev_202405_36293 -
International Journal of Cardiology Jun 2024Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects...
INTRODUCTION
Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects outcomes. Transcatheter aortic valve replacement (TAVR) has shown promise in mitigating PPM compared to surgical aortic valve replacement (SAVR).
METHODS
We conducted a systematic review and meta-analysis following PRISMA guidelines to compare clinical outcomes, mortality, and PPM between SAA patients undergoing TAVR and SAVR. Eligible studies were identified through comprehensive literature searches and assessed for quality and relevance.
RESULTS
Nine studies with a total of 2476 patients were included. There was no significant difference in 30-day Mortality between TAVR vs SAVR groups (OR = 0.65, 95% CI [ 0.09-4.61], P = 0.22). There was no difference between both groups regarding myocardial infarction at 30 days (OR = 0.63, 95% CI [0.1-3.89], P = 0.62). TAVR was associated with a significantly lower 30-day major bleeding and 2-year major bleeding, Pooled studies were homogeneous (OR = 0.44, 95% CI [0.31-0.64], P < 0.01, I2 = 0, P = 0.89), (OR = 0.4 ,95% CI [0.21-0.77], P = 0.03, I2 = 0%, P = 0.62) respectively. TAVR was associated with a lower rate of moderate PPM (OR = 0.6, 95% CI [ 0.44-0.84], p value = 0.01, i2 = 0%, p value = 0.44). The overall effect estimate did not favor any of the two groups regarding short-term Mild AR (OR = 5.44, 95% CI [1.02-28.91], P = 0.05) and Moderate/severe AR (OR = 4.08, 95% CI [ 0.79-21.02], P = 0.08, I2 = 0%, P = 0.59).
CONCLUSION
Our findings suggest that both TAVR and SAVR are viable options for treating AS in patients with a small aortic annulus. TAVR offers advantages in reducing PPM and major bleeding, while SAVR performs better in terms of pacemaker implantation. Future studies should focus on comparing newer generation TAVR techniques and devices with SAVR. Consideration of patient characteristics is crucial in selecting the optimal treatment approach for AS.
PubMed: 38851542
DOI: 10.1016/j.ijcard.2024.132243 -
Journal of Orthopaedic Research :... Jun 2024Revision total hip arthroplasty (rTHA) involving acetabular defects is a complex procedure associated with lower rates of success than primary THA. Computational...
Revision total hip arthroplasty (rTHA) involving acetabular defects is a complex procedure associated with lower rates of success than primary THA. Computational modeling has played a key role in surgical planning and prediction of postoperative outcomes following primary THA, but modeling applications in rTHA for acetabular defects remain poorly understood. This study aimed to systematically review the use of computational modeling in acetabular defect classification, implant selection and placement, implant design, and postoperative joint functional performance evaluation following rTHA involving acetabular defects. The databases of Web of Science, Scopus, Medline, Embase, Global Health and Central were searched. Fifty-three relevant articles met the inclusion criteria, and their quality were evaluated using a modified Downs and Black evaluation criteria framework. Manual image segmentation from computed tomography scans, which is time consuming, remains the primary method used to generate 3D models of hip bone; however, statistical shape models, once developed, can be used to estimate pre-defect anatomy rapidly. Finite element modeling, which has been used to estimate bone stresses and strains, and implant micromotion postoperatively, has played a key role in custom and off-the-shelf implant design, mitigation of stress shielding, and prediction of bone remodeling and implant stability. However, model validation is challenging and requires rigorous evaluation and comparison with respect to mid- to long-term clinical outcomes. Development of fast, accurate methods to model acetabular defects, including statistical shape models and artificial neural networks, may ultimately improve uptake of and expand applications in modeling and simulation of rTHA for the research setting and clinic.
PubMed: 38850264
DOI: 10.1002/jor.25902 -
European Journal of Medical Research Jun 2024Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a... (Review)
Review
Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a potentially infected hip joint have been judged as being only relevant to exclude diagnoses other than infection. Solid data on radiographic presentations of periprosthetic joint infection (PJI) are scarce. As a result, the prognostic value of radiological features in low-grade PJI remains uncertain. The present review article aims to present an overview of the available literature and to develop ideas on future perspectives to define the diagnostic possibilities of radiography in PJIs of the hip. The primary outcome of interest of this systematic review was the radiologic presentation of periprosthetic joint infections of the hip. As secondary outcome of interest served the sensitivity and specificity of the radiologic presentation of periprosthetic joint infections. Of the included articles, 26 were reviews, essays, or case reports and only 18 were clinical studies. Typical radiologic abnormalities of PJI were a periosteal reaction, a wide band of radiolucency at the cement-bone or metal-bone interface, patchy osteolysis, implant loosening, bone resorption around the implant, and transcortical sinus tracts. The frequency of their occurrence is still inadequately defined. A deeper understanding of the underlying causes and the relation between microorganisms to radiologic abnormalities can probably help clinicians in the future to diagnose a PJI. This is why further research shall focus on the radiographic features of PJI.
Topics: Humans; Prosthesis-Related Infections; Prognosis; Arthroplasty, Replacement, Hip; Radiography; Hip Joint; Hip Prosthesis
PubMed: 38849967
DOI: 10.1186/s40001-024-01891-8 -
Frontiers in Endocrinology 2024Various stem cell-loaded scaffolds have demonstrated promising endometrial regeneration and fertility restoration. This study aimed to evaluate the efficacy of stem... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Various stem cell-loaded scaffolds have demonstrated promising endometrial regeneration and fertility restoration. This study aimed to evaluate the efficacy of stem cell-loaded scaffolds in treating uterine injury in animal models.
METHODS
The PubMed, Embase, Scopus, and Web of Science databases were systematically searched. Data were extracted and analyzed using Review Manager version 5.4. Improvements in endometrial thickness, endometrial glands, fibrotic area, and number of gestational sacs/implanted embryos were compared after transplantation in the stem cell-loaded scaffolds and scaffold-only group. The standardized mean difference (SMD) and confidence interval (CI) were calculated using forest plots.
RESULTS
Thirteen studies qualified for meta-analysis. Overall, compared to the scaffold groups, stem cell-loaded scaffolds significantly increased endometrial thickness (SMD = 1.99, 95% CI: 1.54 to 2.44, P < 0.00001; I² = 16%) and the number of endometrial glands (SMD = 1.93, 95% CI: 1.45 to 2.41, P < 0.00001; I² = 0). Moreover, stem cell-loaded scaffolds present a prominent effect on improving fibrosis area (SMD = -2.50, 95% CI: -3.07 to -1.93, P < 0.00001; I² = 36%) and fertility (SMD = 3.34, 95% CI: 1.58 to 5.09, P = 0.0002; I² = 83%). Significant heterogeneity among studies was observed, and further subgroup and sensitivity analyses identified the source of heterogeneity. Moreover, stem cell-loaded scaffolds exhibited lower inflammation levels and higher angiogenesis, and cell proliferation after transplantation.
CONCLUSION
The evidence indicates that stem cell-loaded scaffolds were more effective in promoting endometrial repair and restoring fertility than the scaffold-only groups. The limitations of the small sample sizes should be considered when interpreting the results. Thus, larger animal studies and clinical trials are needed for further investigation.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/PROSPERO, identifier CRD42024493132.
Topics: Female; Endometrium; Regeneration; Tissue Scaffolds; Animals; Humans; Fertility; Stem Cells; Infertility, Female; Stem Cell Transplantation
PubMed: 38846497
DOI: 10.3389/fendo.2024.1397783 -
Medical Science Monitor : International... Jun 2024Prosthodontics is a dental subspecialty that includes the preparation of dental prosthetics for missing or damaged teeth. It increasingly uses computer-assisted... (Review)
Review
Prosthodontics is a dental subspecialty that includes the preparation of dental prosthetics for missing or damaged teeth. It increasingly uses computer-assisted technologies for planning and preparing dental prosthetics. This study aims to present the findings from a systematic review of publications on artificial intelligence (AI) in prosthodontics to identify current trends and future opportunities. The review question was "What are the applications of AI in prosthodontics and how good is their performance in prosthodontics?" Electronic searching in the Web of Science, ScienceDirect, PubMed, and Cochrane Library was conducted. The search was limited to full text from January 2012 to January 2024. Quadas-2 was used for assessing quality and potential risk of bias for the selected studies. A total of 1925 studies were identified in the initial search. After removing the duplicates and applying exclusion criteria, a total of 30 studies were selected for this review. Results of the Quadas-2 assessment of included studies found that a total of 18.3% of studies were identified as low risk of bias studies, whereas 52.6% and 28.9% of included studies were identified as studies with high and unclear risk of bias, respectively. Although they are still developing, AI models have already shown promise in the areas of dental charting, tooth shade selection, automated restoration design, mapping the preparation finishing line, manufacturing casting optimization, predicting facial changes in patients wearing removable prostheses, and designing removable partial dentures.
Topics: Artificial Intelligence; Humans; Prosthodontics; Dental Prosthesis
PubMed: 38840416
DOI: 10.12659/MSM.944310 -
The Journal of Evidence-based Dental... Jun 2024Schiegnitz E, Reinicke K, Sagheb K, König J, Al-Nawas B, Grötz KA. Dental implants in patients with head and neck cancer-A systematic review and meta-analysis of the... (Meta-Analysis)
Meta-Analysis
ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION
Schiegnitz E, Reinicke K, Sagheb K, König J, Al-Nawas B, Grötz KA. Dental implants in patients with head and neck cancer-A systematic review and meta-analysis of the influence of radiotherapy on implant survival. Clinical oral implants research. 2022 Oct;33(10):967-99.
SOURCE OF FUNDING
Open access funding enabled by Project DEAL.
TYPE OF STUDY/DESIGN
Systematic review with meta-analysis of data (SRMA).
Topics: Humans; Head and Neck Neoplasms; Dental Implants; Dental Implantation, Endosseous
PubMed: 38821653
DOI: 10.1016/j.jebdp.2023.101967 -
The International Journal of... May 2024The purpose of this review was to evaluate the periodontal and peri-implant tissue responses to restorative approaches with and without cervical finish line on teeth and...
The purpose of this review was to evaluate the periodontal and peri-implant tissue responses to restorative approaches with and without cervical finish line on teeth and dental implants. An electronic search was performed in PubMed/MEDLINE, Embase, Cochrane Library, LILACS, Web of Science, and Scopus databases, and in the gray literature. Controlled clinical trials and prospective cohort studies were included. Analyzed outcomes included gingival index (GI), bleeding on probing (BOP), probing depth (PD), gingival thickness (GT), marginal stability (MS), and marginal bone loss (MBL). A meta-analysis was then performed in two parts: the first compared results of restorations on teeth with and without cervical finish line, and the second compared results of restorations on implant abutments with and without cervical finish line. Regarding the tooth-based restoration analysis, 7 out of 1,388 selected articles were included in the systematic review, and 2 were selected for the meta-analysis. For implantbased restorations on abutments with and without cervical finish line, 6 out of 707 selected articles were included in the systematic review, and 2 in the meta-analysis. No significant differences in periodontal and peri implant indexes were identified between both prosthetic approaches in situations with and without cervical finish lines.
PubMed: 38820274
DOI: 10.11607/prd.7037 -
The International Journal of... Feb 2024The purpose of this systematic review and meta-analysis was to compare the influence of fabrication method (conventional, subtractive, and additive procedures) and... (Meta-Analysis)
Meta-Analysis
Influence of the Manufacturing Trinomial (Technology, Printer, and Material) on the Marginal and Internal Discrepancies of Printed Metal Frameworks for the Fabrication of Tooth-Supported Prostheses: A Systematic Review and Meta-analysis.
PURPOSE
The purpose of this systematic review and meta-analysis was to compare the influence of fabrication method (conventional, subtractive, and additive procedures) and manufacturing trinomial (technology, printer, and material combination) on the marginal and internal fit of cobaltchromium (Co-Cr) tooth-supported frameworks.
MATERIALS AND METHODS
An electronic systematic review was performed in five data bases: MEDLINE/PubMed, Embase, World of Science, Cochrane, and Scopus. Studies that reported the marginal and internal discrepancies of tooth-supported Co-Cr additive manufacturing (AM) frameworks were included. Two authors independently completed the quality assessment of the studies by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies. A third examiner was consulted to resolve lack of consensus.
RESULTS
A total of 31 articles were included and classified based on the evaluation method: manufacturing accuracy, the dual- or triple-scan method, stereomicroscope, optical coordinate measurement machine, microCT, profilometer, and silicone replica. Six subgroups were created: 3D Systems, Bego, Concept Laser, EOS, Kulzer, and Sisma. Due to the heterogeneity and limited data available, only the silicone replica group was considered for meta-analysis. The metaanalysis showed a mean marginal discrepancy of 91.09 μm (I2 = 95%, P < .001) in the conventional group, 77.48 μm (I2 = 99%, P < .001) in the milling group, and 82.92 μm (I2 = 98%, P < .001) in the printing group. Additionally, a mean internal discrepancy of 111.29 μm (I2 = 94%, P < .001) was obtained in the conventional casting group, 121.96 μm (I2 = 100%, P < .001) in the milling group, and 121.25 μm (I2 = 99%, P < .001) in the printing group.
CONCLUSIONS
Manufacturing method and selective laser melting (SLM) metal manufacturing trinomial did not impact the marginal and internal discrepancies of Co-Cr frameworks for the fabrication of tooth-supported restorations.
Topics: Humans; Computer-Aided Design; Chromium Alloys; Dental Marginal Adaptation; Printing, Three-Dimensional; Denture Design; Dental Prosthesis Design; Technology, Dental; Dental Materials
PubMed: 38819942
DOI: 10.11607/ijp.8830