Annals of Vascular Diseases Jun 2024: In patients with abdominal aortic aneurysm (AAA), early detection and optimal elective treatment before rupture are desirable. In the absence of an established public...
: In patients with abdominal aortic aneurysm (AAA), early detection and optimal elective treatment before rupture are desirable. In the absence of an established public screening system, opportunistic screening during ultrasound examination for another purpose might be efficacious. The aim of this study was to evaluate the efficacy of opportunistic screening for AAA. : This prospective multicenter observational study enrolled patients who were scheduled to undergo ultrasound for reasons other than AAA. After the ultrasound for the original purpose, evaluation of the abdominal aorta was added. If the abdominal aorta was clear enough for measurement, its diameter and shape were recorded. Furthermore, information on comorbidities was collected for each patient. : A total of 10325 patients (echocardiography: 6150; abdominal ultrasound: 4162) from 16 institutions were enrolled. The abdominal aorta was well visualized in 92.9% of patients who underwent echocardiography. Among 9791 patients, AAA was diagnosed in 122 (1.3%) (107 fusiform and 15 saccular), with a diameter range of 30-63 mm. The diagnostic rate increased with age. On multivariate analysis, older age, male sex, coronary artery disease, peripheral arterial disease, and smoking habituation were the risk factors for AAA. : Opportunistic screening for AAA was efficacious.
PubMed: 38919325
DOI: 10.3400/avd.oa.23-00110 -
Indian Journal of Thoracic and... Jul 2024In today's era, cardiac catheterization procedures are becoming increasingly safe, but they are still fraught with complications. We aimed to study the outcomes of...
BACKGROUND
In today's era, cardiac catheterization procedures are becoming increasingly safe, but they are still fraught with complications. We aimed to study the outcomes of patients who underwent emergency surgical intervention for complications in the cardiac catheterization laboratory.
METHODS
A retrospective analysis of patients who required emergency surgical management following a complication in the cardiac catheterization laboratory in our institute from July 2017 to July 2022 was done.
RESULT
A total of 57 patients out of a total of 52,326 patients (0.1%) were included. The average age of presentation was 10.4 years. Congenital heart disease (CHD) constituted the majority of the cases (28/57-49.1%), coronary artery disease (CAD) constituted 19.3% (11/57), and rheumatic heart disease (RHD) constituted 8.8% (5/57) of the cases. Apart from this, 22.80% patients (13/57) were grouped together in the miscellaneous group. In total, 76.9% (10/13) of these patients had pericardial effusion and they developed a right ventricular (RV) rent following an attempted pigtail drainage. Also, one patient each had a RV rent following an attempted permanent pacemaker implantation for heart block and an endocardial biopsy respectively. One patient had a left bronchial rupture following thoracic endovascular aortic repair (TEVAR) for descending thoracic aorta (DTA) aneurysm. Thirty-day mortality was 7% (4/57), and the mean time of shifting the patients from the catheterization laboratory to the operating room was 8.3 h.
CONCLUSION
Cardiac catheterization procedures have become increasingly safe, but complications can still occur, for which the cardiac surgeon should be briefed in a Heart Team meeting before taking up such cases. Even though these complications form a small percentage, the cardiologist should exercise some caution in attempting cases which could have a relatively easier surgical correction.
PubMed: 38919180
DOI: 10.1007/s12055-024-01722-9 -
Aging and Disease Jun 2024Abdominal aortic aneurysm (AAA) is a potentially life-threatening vascular disease primarily in the male elderly population, but there is a lack of approved medical...
Abdominal aortic aneurysm (AAA) is a potentially life-threatening vascular disease primarily in the male elderly population, but there is a lack of approved medical therapies to prevent the progression and rupture of AAA. Activating Transcription Factor 4 (ATF4) has been established to be involved in cardiovascular diseases, such as heart failure and calcific aortic valve disease. However, the role of ATF4 in the pathogenesis of AAA remains unclear. We found that ATF4 expression was significantly increased in patients with AAA and mouse models of AAA and was mainly confined to macrophages in arteries. ATF4 knockdown significantly attenuated aneurysm formation in experimental mouse model of AAA, while ATF4 overexpression promoted the development of AAA. RNA sequencing suggested that ATF4 was strongly related to the biological function of acute inflammatory response. Macrophages-specific ATF4 knockout significantly reduced the incidence and development of AAA, and decreased M1 polarization of macrophages in mice. Sphingomyelin phosphodiesterase 3 (SMPD3), a regulator of inflammatory responses in monocytes/macrophages, has been identified as a target gene of ATF4 through RNA sequencing, ChIP sequencing, and standard ChIP analyses. ATF4 induces M1 polarization of macrophages through the activation of SMPD3, thereby promoting inflammatory responses. Together, these results suggest that ATF4 mediated macrophage M1 polarization by regulating the expression of target genes SMPD3, leading to an increased inflammatory response, which further promotes the formation and development of AAA. These findings suggest ATF4 may be a new therapeutic target for AAA.
PubMed: 38913045
DOI: 10.14336/AD.2024.0116 -
Journal of Vascular Surgery Jun 2024To report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside, Artivion - Kennesaw,...
OBJECTIVES
To report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside, Artivion - Kennesaw, GA - USA).
METHODS
Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED) were prospectively collected (2020-2024); only urgent cases were included in this study. Primary outcomes were technical success and mortality at 30 days. Secondary outcomes were spinal cord ischemia rate, stroke rate, major adverse events (MAE) as also branch instability at 12 months.
RESULTS
Of 185 patients enrolled in the INBREED, 64 (34.5%) were treated in a urgent setting and were included in the study. Reason for urgent repair was presence of aneurysm-related symptoms in 31 (48.4%) patients, a contained rupture in 8 (12.5%), and a large aneurysm >80 mm in 25 (39.1%). Extent of repair was I-III in 32 patients (50% and IV in 32 (50%); 18 (28%) had a narrow (<25 mm) paravisceral aortic lumen. An adjunctive proximal thoracic endograft was deployed in 29 patients (45.3%); a distal bifurcated abdominal endograft was used in 33 (51.5%). Two-hundred-forty-nine (97.2%) target vessels were successfully incorporated through an inner branch from an upper arm (81.2%) or femoral (18.8%) access. A balloon expandable stent was used in 184 (75.7%) target vessels, a self expandable stent in 59 (24.3%). Mean time for target vessel bridging was 39.9±28.4 min per target vessel. Thirty-days cumulative MAE rate was 28% and mortality occurred in 5 patients (9.1%). There were 1 postoperative stroke (1.6%) and SCI rate was 8% (n=5). For the 249 target vessels successfully incorporated through an inner branch, one-year freedom from target vessel instability was 93±3% after 1 year.
CONCLUSION
The E-nside represents a valid solution for the urgent treatment of TAAAs, including symptomatic and ruptured TAAAs, as well as large asymptomatic TAAAs that cannot wait for a custom-made device. The preloaded inner branches and available proximal and distal graft diameters might be useful in urgent settings, and provided satisfactory early and 1-year results, in terms of both endograft and target vessel stability. Further studies are required to assess the clinical role of E-nside for urgent TAAA repair.
PubMed: 38908806
DOI: 10.1016/j.jvs.2024.05.056 -
Journal of Vascular Surgery Jun 2024Type B intramural hematoma (IMH) is often managed medically, yet may progress to dissection, aneurysmal dilation, or rupture. The aim of this study was to report the...
OBJECTIVE
Type B intramural hematoma (IMH) is often managed medically, yet may progress to dissection, aneurysmal dilation, or rupture. The aim of this study was to report the natural history of medically managed Type B IMH, and factors associated with progression.
METHODS
We reviewed patients with medically managed Type B IMH between January 1995 to December 2022 at a single center. Any patients with immediate surgical or endovascular intervention were excluded. Demographic profiles, comorbidities, imaging, and follow-up details were reviewed. Patients were divided into two groups: Group 1 had isolated IMH, and Group 2 had IMH along with aneurysm or dissection at the time of presentation. On follow-up, progression was defined as degeneration to aneurysm/dissection or increase in the thickness of IMH in Group 1. In Group 2, progression was an increase in the size of aneurysm or development of new dissection.
RESULTS
Of 104 patients with Type B IMH during the study period, 92 were medically managed. The median age was 77 years, and 45 (48.9%) were females. Comorbidities included hypertension (83.7%), hypercholesterolemia (44.6%), and active smoking (47.8%). Mean Society for Vascular Surger comorbidity score was 6.3. Mean IMH thickness and aortic diameter at presentation were 8.9 mm and 38.3 mm, respectively. Median follow-up was 55 months. Overall survival at 1 year and 5 years was 85.8% and 61.9%, respectively. During follow-up, 19 patients (20.7%) required intervention, more common in Group 2 (Group 1, 8/66; 12.3% vs Group 2, 11/26; 42.3%; P = .001). This resulted in higher freedom from intervention in Group 1 at 1 year (93.5% vs 62.7%) and 5 years (87.5% vs 51.1%; P < .001). Indication for intervention was dissection (n = 4), aneurysm (n = 12), and progression of IMH (n = 3). In Group 1, progression was seen in 25 (37.9%), three (4.5%) remained stable, 29 (43.9%) had complete resolution of IMH, and nine patients were lost to follow-up. In Group 2, 11 patients (42.3%) had progression, seven (26.9%) remained stable, and eight were lost to follow-up. IMH thickness at presentation >7.2 mm is associated with both increased odds of progression (odds ratio, 3.3; 95% confidence interval, 1.2-11.1; P = .03) and intervention (odds ratio, 5.5; 95% confidence interval, 1.3-36.9; P = .03) during the follow-up.
CONCLUSIONS
Although many patients with Type B IMH managed medically stabilize or regress, progression or need for intervention can occur in up to 40% of cases. This is associated with the presence of aneurysm, dissection, and IMH thickness. Long-term follow-up is mandatory as late interventions occur, particularly for higher risk patients.
PubMed: 38904581
DOI: 10.1016/j.jvs.2024.04.069 -
Journal of Vascular Surgery Jun 2024This study reports the 30-day outcomes of the primary arm of the GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE) pivotal trial for complex abdominal aortic...
BACKGROUND
This study reports the 30-day outcomes of the primary arm of the GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE) pivotal trial for complex abdominal aortic aneurysm repair.
METHODS
This multicenter, nonrandomized, prospective study of the TAMBE device included patients enrolled in the primary study arm of extent IV thoracoabdominal aortic aneurysms and pararenal aneurysms. Technical success and major adverse events were analyzed per the Society for Vascular Surgery guidelines.
RESULTS
The 102 patients of the primary arm who underwent endovascular repair using the TAMBE device were a mean age of 73 ± 6.4 years (range, 58-82 years) and 84 (84.2%) were male. The mean body mass index was 28.3 ± 5.0 kg/m. Fifty-nine patients (57.8%) were treated for extent IV and 43 (42.2%) pararenal aneurysms; the mean maximum diameter of the aneurysms was 59.4 ± 7.8 mm. A prophylactic cerebral spinal fluid drain was used in 10 patients (9.8%). Technical success was achieved in 99% of patients, with the single failure owing to unsuccessful cannulation of the left renal artery. Mean procedure time was 315 ± 103 minutes (range, 163-944 minutes), estimated blood loss was 300 ± 296 mL (range, 10-2000 mL), and contrast administration was 153.6 ± 73.5 mL (range, 16-420 mL). The intensive care unit length of stay was 58.7 ± 52.7 hours (range, 1-288 mL). In 28 patients (27.5%), a total of 32 additional endovascular components were deployed to manage procedural complications including aortic and target vessel dissections and injuries not related to access. Bridging stent grafts were deployed to incorporate 407 target vessels (mean 1.6/per vessel; range, 1-4). Postoperative transfusion was required in 14 patients (13.7%). Major adverse events occurred in seven patients (6.9%) through 30 days. Events included respiratory failure (n = 2), disabling stroke (n = 1), new-onset renal failure requiring dialysis (n = 2), and paraplegia (n = 2). At 30 days, there was one patient with intraoperative rupture; no severe bowel ischemia or lesion-related/all-cause mortality were reported. The Core lab-reported patency was 100% in the aortic component, superior mesenteric artery, and celiac artery, and 95.9% in the left renal and 99.0% in the right renal branch components through 30 days of follow-up. Reinterventions through 30 days were performed in 9 of 96 patients (9.4%) and were all minor.
CONCLUSIONS
Early TAMBE device outcomes demonstrate a high technical success rate, no 30-day lesion-related mortality, and a low rate of safety events within 30 days of the index procedure.
PubMed: 38904579
DOI: 10.1016/j.jvs.2024.05.020 -
Frontiers in Cardiovascular Medicine 2024Behcet's disease (BD) is a systematic vasculitis that affects vessels with various sizes, presenting as venous thrombosis and arterial pseudoaneurysms. The most severe...
BACKGROUND
Behcet's disease (BD) is a systematic vasculitis that affects vessels with various sizes, presenting as venous thrombosis and arterial pseudoaneurysms. The most severe manifestation in BD is ascending aortic pseudoaneurysm, which is associated with high risks of rupture and mortality.
CASE PRESENTATION
We present a case of ascending aortic pseudoaneurysm in a 50-year-old patient with BD. After preoperative evaluation, coil embolization was successfully performed to treat the pseudoaneurysm, resulting in a satisfactory outcome at the 1-year follow-up.
CONCLUSION
Coil embolization serves as an effective treatment option for ascending aortic pseudoaneurysm in BD when open surgical repair and stent graft placement are unsuitable.
PubMed: 38903968
DOI: 10.3389/fcvm.2024.1392236 -
Journal of Medical Case Reports Jun 2024An aortoesophageal fistula can prove to be fatal. Salvage thoracic endovascular aortic repair as a bridging therapy and radical surgery with thoracotomy should be...
BACKGROUND
An aortoesophageal fistula can prove to be fatal. Salvage thoracic endovascular aortic repair as a bridging therapy and radical surgery with thoracotomy should be considered while treating aortoesophageal fistula without spontaneous closure. Moreover, it is essential to select a technique that reduces the risk of reinfection. Here we report a rare case of a ruptured thoracic aortic aneurysm related to esophageal perforation by a fish bone that led to massive hematemesis and shock, and the surgical treatment of an aortoesophageal fistula that developed after salvage thoracic endovascular aortic repair.
CASE PRESENTATION
A 70-year-old Japanese female patient was admitted with hematemesis, thoracic pain, and shock related to esophageal perforation of a ruptured descending aortic aneurysm caused by fish bone aspiration and esophageal perforation 1 month previously. An emergency thoracic endovascular aortic repair was performed. Postoperatively, an aortoesophageal fistula that remained open and a food intake-related increase in the inflammatory response was noted. Radical blood-vessel prosthesis implantation and fistula closure were performed. The patient's postoperative course was favorable and the patient was discharged 22 days after the blood vessel prosthesis implantation.
CONCLUSION
Such a case of rupture of a descending aortic aneurysm related to perforation by a fish bone and an aortoesophageal fistula is considerably rare. Thus, we report the therapeutic strategy of this particular case and review the relevant literature.
Topics: Humans; Female; Esophageal Fistula; Aged; Endovascular Procedures; Aortic Aneurysm, Thoracic; Aortic Rupture; Esophageal Perforation; Vascular Fistula; Blood Vessel Prosthesis Implantation; Salvage Therapy; Animals; Hematemesis; Aortic Diseases; Aorta, Thoracic; Treatment Outcome; Fishes; Endovascular Aneurysm Repair
PubMed: 38902817
DOI: 10.1186/s13256-024-04605-0 -
Npj Aging Jun 2024Aortic aneurysms are dilatations of the aorta that can rupture when left untreated. We used the aneurysmal Fibulin-4 mouse model to further unravel the underlying...
Aortic aneurysms are dilatations of the aorta that can rupture when left untreated. We used the aneurysmal Fibulin-4 mouse model to further unravel the underlying mechanisms of aneurysm formation. RNA sequencing of 3-month-old Fibulin-4 aortas revealed significant upregulation of senescence-associated secretory phenotype (SASP) factors and key senescence factors, indicating the involvement of senescence. Analysis of aorta histology and of vascular smooth muscle cells (VSMCs) in vitro confirmed the senescent phenotype of Fibulin-4 VSMCs by revealing increased SA-β-gal, p21, and p16 staining, increased IL-6 secretion, increased presence of DNA damage foci and increased nuclei size. Additionally, we found that p21 luminescence was increased in the dilated aorta of Fibulin-4|p21-luciferase mice. Our studies identify a cellular aging cascade in Fibulin-4 aneurysmal disease, by revealing that Fibulin-4 aortic VSMCs have a pronounced SASP and a senescent phenotype that may underlie aortic wall degeneration. Additionally, we demonstrated the therapeutic effect of JAK/STAT and TGF-β pathway inhibition, as well as senolytic treatment on Fibulin-4 VSMCs in vitro. These findings can contribute to improved therapeutic options for aneurysmal disease aimed at reducing senescent cells.
PubMed: 38902222
DOI: 10.1038/s41514-024-00154-4 -
Computers in Biology and Medicine Jun 2024Thoracic endovascular aortic repair (TEVAR) is a minimally invasive procedure involving the placement of an endograft inside the dissection or an aneurysm to direct...
Thoracic endovascular aortic repair (TEVAR) is a minimally invasive procedure involving the placement of an endograft inside the dissection or an aneurysm to direct blood flow and prevent rupture. A significant challenge in endovascular surgery is the geometrical mismatch between the endograft and the artery, which can lead to endoleak formation, a condition where blood leaks between the endograft and the vessel wall. This study uses computational modeling to investigate the effects of artery curvature and endograft oversizing, the selection of an endograft with a larger diameter than the artery, on endoleak creation. Finite element analysis is employed to simulate the deployment of endografts in arteries with varying curvature and diameter. Numerical simulations are conducted to assess the seal zone and to quantify the potential endoleak volume as a function of curvature and oversizing. A theoretical framework is developed to explain the mechanisms of endoleak formation along with proof-of-concept experiments. Two main mechanisms of endoleak creation are identified: local buckling due to diameter mismatch and global buckling due to centerline curvature mismatch. Local buckling, characterized by excess graft material buckling and wrinkle formation, increases with higher levels of oversizing, leading to a larger potential endoleak volume. Global buckling, where the endograft bends or deforms to conform to the centerline curvature of the artery, is observed to require a certain degree of oversizing to bridge the curvature mismatch. This study highlights the importance of considering both curvature and diameter mismatch in the design and clinical use of endografts. Understanding the mechanisms of endoleak formation can provide valuable insights for optimizing endograft design and surgical planning, leading to improved clinical outcomes in endovascular aortic procedures.
PubMed: 38901185
DOI: 10.1016/j.compbiomed.2024.108745