Journal of Prosthodontic Research Feb 2024This systematic review examined the effectiveness of soft denture relining (SDR) materials.
PURPOSE
This systematic review examined the effectiveness of soft denture relining (SDR) materials.
STUDY SELECTION
A comprehensive search of MEDLINE, Cochrane Library, and ICHUSHI was conducted up to July 26, 2020. Target outcomes were patient satisfaction, oral health-related quality of life (OHRQOL), masticatory ability (MA), denture functional duration, residual ridge resorption (RRR), and microbial contamination. An organization specializing in literature searches performed the reference searches, and two reviewers independently selected the literature sources, extracted the data, and assessed the risk of bias. The reviewers resolved any disagreements concerning the assortment of literature sources through discussion. SDR included acrylic- and silicone-based materials, which were evaluated separately.
RESULTS
Reviewers selected 7, 5, 11, 1, 4, and 6 studies to assess patient satisfaction, OHRQOL, MA, functional duration, RRR, and microbial contamination, respectively. The results confirmed that SDR improved patient satisfaction, OHRQOL, MA, and RRR. However, the functional duration of SDR material is shorter than that of hard denture relining (HDR) or acrylic resin material. Furthermore, SDR material is more susceptible to microbial contamination in the long term. The risk of bias for the included studies tended to be high because of specific issues (difficulty in blinding SDR versus HDR).
CONCLUSIONS
For patients who wear complete dentures, SDR often provides beneficial outcomes such as pain reduction and recovery from MA. However, caution should be exercised regarding their use owing to insufficient functional duration and the possibility of microbial contamination during long-term use.
PubMed: 38382972
DOI: 10.2186/jpr.JPR_D_23_00067 -
Cureus Jan 2024Removable partial dentures (RPDs) offer a broad range of aesthetics and restorative functions for partially edentulous patients. This systematic review examines... (Review)
Review
Removable partial dentures (RPDs) offer a broad range of aesthetics and restorative functions for partially edentulous patients. This systematic review examines patients' satisfaction rates and the factors that influence RPD satisfaction. This systematic review was conducted according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and the Cochrane Handbook for Systematic Reviews. A systematic literature search was done on PubMed, Scopus, and Google Scholar using preset inclusion criteria. A total of 923 non-duplicate articles were screened, and 35 were included in this review. Among the included studies, RPDs generally exhibited high satisfaction rates, with reported rates ranging between 50% and 81%. Several factors influenced satisfaction. Age played a major role, with older adults expressing higher satisfaction. Gender differences were also noted, especially in appearance satisfaction where women were more satisfied with RPDs than men. Prior experience with RPDs correlated positively with overall satisfaction. The number and location of missing teeth, as well as the type of RPD (metal vs. flexible), significantly influenced satisfaction levels. Flexible dentures were more satisfactory than metal RPDs. Attachments, such as magnetic attachments and implants, increased satisfaction. Patient complaints, encompassing pain, aesthetics, and cleanliness, were identified as common sources of dissatisfaction. The results underscore the significance of customizing RPD treatment to individual needs, considering factors that influence RPD satisfaction. Recognizing the importance of influential factors such as age, gender RPD experience, etc., for clinicians seeking to optimize patient outcomes in RPD therapy is crucial.
PubMed: 38322077
DOI: 10.7759/cureus.51793 -
Heliyon Feb 2024To investigate whether the clinical and radiographical outcomes are affected when four or six implants support the maxillary fixed complete denture (FCD).
Outcomes that may affect implant and prosthesis survival and complications in maxillary fixed prosthesis supported by four or six implants: A systematic review and meta-analysis.
OBJECTIVE
To investigate whether the clinical and radiographical outcomes are affected when four or six implants support the maxillary fixed complete denture (FCD).
MATERIALS AND METHODS
This study was registered on PROSPERO (CRD42021226432) and followed the PRISMA guidelines. The focused PICO question was, "For an edentulous maxillary patient rehabilitated with an implant-supported fixed prosthesis, do the clinical and radiographical outcomes differ when four or six implants support the prosthesis ". A thorough search of the relevant studies was designed and performed electronically. The survival rate of implant and prosthesis, marginal bone loss, and complications (mechanical and biological) were the primary outcomes, whereas implant distribution and using the surgical guide, follow-up, and framework material were evaluated as secondary outcomes.
RESULTS
Out of 1099 articles initially retrieved, 53 clearly stated the outcomes of interest and were included in this study. There were no significant differences in implant and prosthesis survival, technical/mechanical complications, and biological complications between the 4-implant group (4-IG) and the 6-implant group (6-IG). However, marginal bone loss (MBL) was significantly higher in the 4-IG (p < 0.01). The surgical guide and follow-up period did not significantly affect implant/prosthesis survival. Additionally, using the CAD/CAM milled framework and anteroposterior implant distribution were associated with significantly higher implant survival in the 6-IG (p < 0.01).
CONCLUSION
The findings of this study indicated that having a greater number of implants, as seen in the 6-implant group, can lead to a decrease in technical and biological complications and reduce marginal bone loss. It is worth noting that factors such as using CAD/CAM frameworks and the anteroposterior distribution of implants were recognized as important in improving implant survival rates when more implants are present.
PubMed: 38317918
DOI: 10.1016/j.heliyon.2024.e24365 -
The Journal of Prosthetic Dentistry Jan 2024Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is... (Review)
Review
STATEMENT OF PROBLEM
Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is more rapid and less costly than the conventional process.
PURPOSE
The purpose of this systematic review was to analyze and compare the duration and cost of fixed dental prostheses fabricated using digital and conventional methods from scanning or impression making to delivery of the prosthesis.
MATERIAL AND METHODS
A systematic review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol (PRISMA-P 2015) guidelines. The analysis methods and inclusion criteria were documented in a protocol registered in the Prospective International Register of Systematic Reviews (PROSPERO) (CRD42023458734). The bibliographic search was carried out using PubMed, Cochrane, and PROSPERO databases. The main keywords used were (Prosthodontic OR restorative dentistry OR denture) AND (CAD CAM OR Digital workflow OR Computer Dentistry OR Digital Design) AND (Economic OR cost OR Financial OR time efficiency). Two investigators undertook the different steps of article selection.
RESULTS
A total of 8 articles published between 2010 and 2023 were found for the qualitative synthesis by using the search criteria. Two studies showed that conventional impressions took more time than digital scans for the fabrication of a single crown, and 1 study showed the opposite. One study found that a digital scan was faster than conventional impression making for the fabrication of a 3-unit fixed partial denture, and another study showed the opposite. The dental laboratory technician spent more time on the conventional workflow than the digital workflow for the 3-unit framework and veneering process. No difference was found between conventional and digital workflows for clinical evaluation and chairside adjustment for the fabrication of a single crown. No articles have compared the cost of fixed prostheses.
CONCLUSIONS
The digital pathway can shorten the laboratory process. However, the duration of the impression or scan may vary depending on the technique used. Studies are needed to analyze the cost-effectiveness of the fabrication of tooth-supported restorations.
PubMed: 38302291
DOI: 10.1016/j.prosdent.2024.01.003 -
BMC Oral Health Jan 2024Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants...
Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants and peri-implant tissues.Aim: To evaluate the impact of implant-supported removable prostheses bar designs in fully edentulous arch (in the maxilla and/or mandibula), with 4 implants or more, on the peri-implant soft and hard tissues.Two reviewers searched for observational studies, RCT and in vitro studies, published on five main databases and three from the grey literature, without restrictions on November 2023.Of the 3049 selected articles, four met the inclusion criteria. Four RCT evaluated peri-implant health tissues in full edentulous arches with 4 or 6 implants rehabilitated with implant bar overdentures. One prospective study with 5 years follow-up evaluated the success/survival rate of implants and implant bar overdentures. Overall, 261 subjects were enrolled in our systematic review with 1176 implants. Overdentures' survival rate was 100%. There was a trend that plaque indices and gingival indices were low in all of the studies, however no statistical analysis was done due to the lack of information.Due to the lack of information in the included studies, we cannot confirm if bar characteristics affect the peri-implant tissues health.
Topics: Humans; Dental Implants; Prospective Studies; Jaw, Edentulous; Dental Prosthesis, Implant-Supported; Mouth, Edentulous; Mandible; Denture, Overlay; Denture Retention
PubMed: 38281916
DOI: 10.1186/s12903-024-03915-5 -
BMC Oral Health Jan 2024Photodynamic therapy (PDT) has been recently proposed as a promising alternative therapy for Denture Stomatitis (DS). The present systematic review and meta-analysis... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Photodynamic therapy (PDT) has been recently proposed as a promising alternative therapy for Denture Stomatitis (DS). The present systematic review and meta-analysis investigated the current available evidence regarding the efficacy of PDT in the management of DS.
MATERIALS AND METHODS
PubMed, Scopus, Web of Science, Google Scholar, and ProQuest were searched up to June 7, 2023. All relevant clinical trials were included. RevMan software was used for the statistical analyses.
RESULTS
Elven randomized clinical trials (460 DS patients) were included. Eight studies assessed the efficacy of PDT vs. topical antifungal therapy, while three studies assessed the adjunctive use of PDT (PDT + antifungal therapy) vs. topical antifungal therapy alone. The results revealed comparable efficacy of PDT and conventional antifungal therapy on candida colonization at 15 days (MD: 0.95, 95% CI: -0.28, 2.19, p = 0.13) and at the end of follow-up (MD: -0.17, 95% CI: -1.33, 0.98, p = 0.77). The pooled two studies revealed relatively better efficacy of adjunctive use of PDT with antifungal therapy on candida colonization compared to antifungal therapy alone at 15 days (MD: -6.67, 95% CI: -15.15, 1.82, p = 0.12), and at the end of follow-up (MD: -7.14, 95% CI: -19.78, 5.50, p = 0.27). Additionally, the results revealed comparable efficacy of PDT and topical antifungal therapy on the clinical outcomes.
CONCLUSIONS
PDT might be considered a viable option for DS either as an adjunct or as an alternative to the topical antifungal medications. Further studies with adequate sample sizes and standardized PDT parameters are warranted.
Topics: Humans; Antifungal Agents; Candida; Photochemotherapy; Stomatitis, Denture
PubMed: 38229054
DOI: 10.1186/s12903-023-03789-z -
BMC Oral Health Dec 2023Ameloblastoma (AM), the benign counterpart of ameloblastic carcinoma, is a benign odontogenic tumor of epithelial origin, naturally aggressive, with unlimited growth...
BACKGROUND
Ameloblastoma (AM), the benign counterpart of ameloblastic carcinoma, is a benign odontogenic tumor of epithelial origin, naturally aggressive, with unlimited growth potential and a high tendency to relapse if not adequately removed. Patients with AM treated surgically can benefit from dental implant therapy, promoting oral rehabilitation and improving their quality of life. The present study aimed to determine the survival rate of dental implants placed after surgical treatment of patients affected by AM. In addition, there were two secondary objectives: 1) To evaluate which dental implant loading protocols are most frequently used and 2) To determine the type of prosthetic restoration most commonly used in these patients.
METHODS
The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines were followed during the study. Searches were performed in three databases (PubMed/MEDLINE, Scopus, and Google Scholar) until November 2023. Additionally, the electronic search was enriched by an iterative hand search of journals related to oral pathology and medicine, maxillofacial surgery, and oral prosthodontics and implantology. Only reports and case series in English from January 2003 to date were included. The Joanna Briggs Institute tool (JBI-Case Reports/Case Series) was used for the study quality assessment.
RESULTS
The total number of patients and implants studied were 64 and 271, respectively, all with surgically treated AM. The patient's ages ranged from 8 to 79 years, with a mean (SD) age of 37.3 ± 16.4. Fifty-three percent were male and 47% were female. The range of follow-up duration was 1 to 22 years. An implant survival/success rate of 98.1% was reported. In addition, most of them were conventionally loaded (38.3%). Hybrid implant-supported fixed dentures were the most commonly used by prosthodontists (53%).
CONCLUSIONS
Oral rehabilitation with dental implants inserted in free flaps for orofacial reconstruction in surgically treated patients with AM can be considered a safe and successful treatment modality.
Topics: Adolescent; Adult; Aged; Child; Female; Humans; Male; Middle Aged; Young Adult; Ameloblastoma; Dental Implantation, Endosseous; Dental Implants; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Neoplasm Recurrence, Local; Odontogenic Tumors; Quality of Life; Treatment Outcome
PubMed: 38110933
DOI: 10.1186/s12903-023-03765-7 -
BMC Oral Health Dec 2023The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications... (Meta-Analysis)
Meta-Analysis
PURPOSE OF THE STUDY
The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications using conventional impression methods improve the marginal and internal fit?
BACKGROUND
The incorporation of digital technology in the fabrication of fixed partial dentures (FPDs) has accelerated over the past decade. This study is directed at evaluating the marginal and internal fit of FPDs manufactured using digital approaches compared to conventional techniques. The need for updated data has encouraged this review.
MATERIALS AND METHODS
An electronic search was conducted in PubMed, Scopus, Web of Science, and the Grey Database to identify relevant studies. The Modified Methodological Index for Non-Randomized Studies (MINORS) was used to assess the risk of bias in in vitro experiments. The key results of this meta-analysis were the standard mean differences (SMDs) and 95% confidence intervals (CI) of each main variance, marginal fit, and internal fit between the digital and conventional techniques. Additional analyses were performed to assess the significance of three subgroup parameters: method of digitalization, cement spacer thickness, and span length, and their influence on the fit of the FPDs.
RESULTS
Based on predefined criteria, of the seven articles included in this systematic review, only five were selected for the quantitative data analysis. The marginal fit results were (P = 0.06; SMD: -1.88; 95% CI: - 3.88, 0.11) (P > 0.05) and the internal fit results were (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.10) (P < 0.05). Regarding the subgroup analyses, the method of digitalization subgroup results were (P = 0.35; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.80; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively. The span length results were (P = 0.10; SMD: -1.89; 95% CI: - 3.89, 0.11) for marginal fit and (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.11) for internal fit. The cement spacer thickness (P = 0.01; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.04; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively.
CONCLUSION
Tooth-retained fixed partial dentures FPDs produced by digital scanning and computer-aided design/computer-aided manufacturing (CAD/CAM) systems can significantly enhance the internal fit compared with those manufactured by traditional methods. Intraoral scanners can replace conventional impressions for the fabrication of FPDs because they minimize the operating time and reduce patient pain. Further clinical studies are required to obtain more conclusive results.
SYSTEMATIC REVIEW REGISTRATION
This systematic review and meta-analysis was registered in the International Prospective Register of Systematic Reviews (PROSPERO), registration number CRD42021261397.
Topics: Humans; Dental Marginal Adaptation; Denture, Partial, Fixed; Computer-Aided Design; Research Design; Dental Prosthesis Design
PubMed: 38049754
DOI: 10.1186/s12903-023-03628-1 -
Cureus Oct 2023The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not... (Review)
Review
The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not been extensively compared in prior studies. Moreover, there is no agreement on the more accurate method that entails less time in the laboratory and during the clinical phases of fabrication and delivery of the prosthesis, respectively. This review aimed to assess the precision of the imaging procedure and overall fabrication time of the DIT and CIT for the implant-supported FPDs. An electronic search was performed using PubMed, Scopus, EMBASE, Cochrane Oral Health Group, and Dentistry and Oral Science Source databases through EBSCO for relevant studies from January 2014 to April 2023. Following the preliminary screening, the studies that met the inclusion criteria underwent full-text review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Cochrane Collaboration risk of bias appraisal tool and Newcastle-Ottawa scale were applied to assess the quality of randomized controlled trials (RCTs) and non-randomized prospective clinical studies, respectively. The initial search yielded 332 studies, and after excluding duplicates, 241 papers were available for screening. Titles and abstracts were reviewed, and 97 articles were chosen for full-text review by two authors independently. Furthermore, 89 articles were excluded in compliance with the PICOS question, and eight studies were chosen for qualitative analysis. Hence, the review comprised two RCTs and six prospective clinical studies. The time efficiency of the implant-supported FPDs was examined in four investigations, three of which used the Trios 3 scanner and one used the Intero scanner. The three-dimensional accuracy of DIT and CIT was compared in six clinical comparative studies. One of the RCTs was rated to have a high risk of bias and the other with a moderate quality of evidence. The six prospective studies were rated to have high-quality of evidence. The findings of this review indicate the prospective applicability of future intraoral scanning systems. The DIT was reported to be outstanding in terms of patient preferences and total fabrication time efficiency. Additional in vivo studies are needed to establish the therapeutic usefulness and time efficiency of integrating DIT in more comprehensive settings.
PubMed: 38034200
DOI: 10.7759/cureus.48027 -
International Journal of Nanomedicine 2023The main objective of this systematic review was to evaluate the effect of coating with titanium dioxide nanoparticles (TiO nanoparticle) on the surface condition of... (Review)
Review
BACKGROUND
The main objective of this systematic review was to evaluate the effect of coating with titanium dioxide nanoparticles (TiO nanoparticle) on the surface condition of removable acrylic resin prosthetic base materials.
METHODS
Our review is registered in the PROSPERO database under the identification code CRD42023397170. Electronic database searches of PubMed, Scopus and Science Direct including studies from January 2009 to January 2023 were conducted and supplemented with manual searches. Research questions were generated in accordance with the PICO strategy. The modified Consolidated Standards of Reporting Trials (CONSORT) checklist was used to evaluate the quality of the selected studies.
RESULTS
Since the included studies were variable in design, a meta-analysis was not performed. The electronic searches retrieved 29 references that met the eligibility criteria, among which 5 studies matched the inclusion criteria for this review. Significant differences were detected between the TiO NP-coated and uncoated groups. The available data indicate that TiO NP coating elicits antimicrobial activity and improves the wear resistance of polymethylmethacrylate (PMMA) surfaces. Moreover, the nanoparticles provide high levels of glossiness and decelerate the process of color change of heat-cured acrylic resin, thus increasing the lifespan of dentures.
CONCLUSION
The collective results clearly indicate that TiO nanoparticle coating induces alterations in the surface properties of pure PMMA, enhancing the mechanical, physical and biological characteristics of the denture base material. Further studies are essential to identify the optimal thickness of coating and concentrations of nanoparticles for clinical applications.
Topics: Polymethyl Methacrylate; Denture Bases; Surface Properties; Acrylic Resins; Titanium; Materials Testing
PubMed: 38026530
DOI: 10.2147/IJN.S425702