-
Dentistry Journal Oct 2023Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose... (Review)
Review
Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and determine whether intraoral scanners have clinically acceptable accuracy when recording completely edentulous arches for the fabrication of removable complete dentures. An electronic search in medical databases like PubMed, Scopus, and Web of Science (WOS), using a combination of relevant keywords, retrieved 334 articles. After full-text evaluation, twelve articles fulfilled the inclusion criteria for this review (eight clinical studies and four in vitro studies). A quality analysis of the included studies was carried out using the QUADAS-2 tool. The accuracy values varied between different intraoral scanners. Different regions of the edentulous arches showed differences in trueness and precision values in both in vitro and clinical studies. Peripheral borders, the inner seal, and poorly traceable structures like the soft palate showed maximum discrepancies. The accuracy of intraoral scanners in recording clear anatomic landmarks like hard tissues with attached mucosa was comparable to conventional edentulous arch impressions. However, higher discrepancies were recorded when digitizing mobile and poorly traceable structures. Intraoral scanners can be used to digitize denture-bearing areas, but the interpretation of the peripheral border and the soft palate should be carefully carried out.
PubMed: 37886926
DOI: 10.3390/dj11100241 -
BMC Oral Health Oct 2023To evaluate the clinical efficacy of photodynamic therapy (PDT) as an adjunct or alternative to traditional antifungal drugs in the treatment of oral candidiasis, and to... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To evaluate the clinical efficacy of photodynamic therapy (PDT) as an adjunct or alternative to traditional antifungal drugs in the treatment of oral candidiasis, and to provide evidence-based medical evidence for its use in the treatment of oral candidiasis.
METHODS
Computer combined with manual retrieval of China Academic Journals Full-text Database (CNKI), China Biomedical Literature Database (CBM), Chinese Science and Technology Journal Database (VIP), Wanfang Database, PubMed, Web of Science, Cochrane Library, Embase, Scopus retrieval for articles published before January 2023, basic information and required data were extracted according to the inclusion and exclusion criteria, and the Revman V5.4 software was used to conduct Meta-analysis of the included literature.
RESULTS
A total of 11 articles were included, 7 of which used nystatin as an antifungal drug, 2 of which were combined treatment of PDT and nystatin, 2 of the remaining 4 articles were treated with fluconazole, and 2 were treated with miconazole. Meta results showed that PDT was superior to nystatin in reducing the number of oral candida colonies in the palate of patients MD = -0.87, 95%CI = (-1.52,-0.23), P = 0.008, the difference was statistically significant, and the denture site MD = -1.03, 95%CI = (-2.21, -0.15), P = 0.09, the difference was not statistically significant; compared with the efficacy of fluconazole, RR = 1.01, 95%CI = (0.56,1.83), P = 0.96; compared with miconazole RR = 0.55, 95%CI = (0.38, 0.81), P = 0.002; PDT combined with nystatin RR = 1.27, 95%CI = (1.06, 1.52), P = 0.01; recurrence rate RR = 0.28, 95%CI = (0.09, 0.88), P = 0.03.
CONCLUSIONS
PDT was effective in the treatment of oral candidiasis; PDT was more effective than nystatin for the treatment of denture stomatitis in the palate, while there was no significant difference between the two for the denture site; The efficacy of PDT for oral candidiasis was similar to that of fluconazole; PDT was less effective than miconazole for oral candidiasis; Compared with nystatin alone, the combination of PDT and nystatin is more effective in treating oral candidiasis with less risk of recurrence.
Topics: Humans; Candidiasis, Oral; Antifungal Agents; Nystatin; Fluconazole; Miconazole; Photochemotherapy
PubMed: 37884914
DOI: 10.1186/s12903-023-03484-z -
Journal of Indian Prosthodontic Society 2023Implant-supported prostheses have considerable biomechanical advantages in partially edentulous patients when compared to other prosthetic options. Given the steady drop... (Meta-Analysis)
Meta-Analysis
Implant-supported prostheses have considerable biomechanical advantages in partially edentulous patients when compared to other prosthetic options. Given the steady drop in the frequency of patients reporting with complete edentulism, it is not unusual to see situations where teeth and implants can be splinted to provide support for fixed prostheses. A tooth implant prosthesis differs majorly from an implant-supported prosthesis in terms of force dissipation and design. The aim of this systematic review was to compare the survival rates of tooth-implant-supported prostheses with fully implant-supported and fully tooth-supported prostheses. Using the appropriate search terms, PubMed, Google Scholar, and other indexed journals were used to search the English-language literature. According to the review protocols and the PICOS inclusion criteria, the pertinent studies were chosen. The screening of appropriate studies, evaluation of study quality, and data extraction were carried out independently by two reviewers. The pooling of survival data by prostheses failure, implant failure, and marginal bone loss was used in the meta-analysis. The cumulative data of all included studies indicated that tooth-implant-supported prostheses showed a 5-year survival rate of 77%-84% and a 10-year survival rate of 72%. The pooled risk ratio for prostheses failure and implant failure was 0.99 and 1.76, respectively. These results were not statistically significant (P > 0.05). The pooled standard mean difference for marginal bone loss was 0.59, and the results were statistically significant (P < 0.05). A tooth-implant-supported fixed partial denture (FPD) has a similar survival rate when compared to implant-supported FPD or T-FPD.
Topics: Humans; Dental Implants; Tooth; Dental Implantation; Dental Prosthesis, Implant-Supported
PubMed: 37861608
DOI: 10.4103/jips.jips_161_23 -
Cureus Sep 2023Denture stomatitis (DS), a common oral condition among denture wearers, is frequently associated with () colonization. This systematic review and meta-analysis aimed to... (Review)
Review
Denture stomatitis (DS), a common oral condition among denture wearers, is frequently associated with () colonization. This systematic review and meta-analysis aimed to provide a comprehensive assessment of DS prevalence and its relationship with in the Indian population. We conducted a thorough search of multiple databases for studies without any limitation to the publication timeframe, using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Eligible studies were assessed for quality and included in the meta-analysis. Data regarding DS prevalence, risk factors, and colonization were extracted and analyzed. A total of four studies comprising 415 participants were included in the review. The overall odds ratio (OR) and risk ratio (RR) for the prevalence of in DS patients were 0.75 (95% CI 0.56 to 0.99) and 0.83 (95% CI 0.70 to 1.00), respectively, indicating a statistically significant association between DS and colonization. Several risk factors, including continuous denture wearing, advanced denture age, poor denture hygiene, and high sugar intake, were identified as contributing to DS development. This systematic review and meta-analysis highlight the substantial burden of DS and its association with colonization in the Indian population. The findings emphasize the need for comprehensive oral care, improved denture hygiene, dietary counseling, and interventions to enhance salivary flow in denture wearers to mitigate the risk of DS. These insights can inform healthcare providers and policymakers to develop targeted strategies for DS prevention and management in India. Furthermore, this study emphasizes the significance of oral health awareness and preventive strategies in groups with a high frequency of denture usage in a larger population.
PubMed: 37842362
DOI: 10.7759/cureus.45182 -
Cureus Sep 2023Restoration of hemimandibulectomy defects following tumour extirpation to restore oral function is a herculean task for practitioners. Prosthetic treatment alternatives... (Review)
Review
Restoration of hemimandibulectomy defects following tumour extirpation to restore oral function is a herculean task for practitioners. Prosthetic treatment alternatives available for rehabilitation of acquired hemimandibulectomy defects according to mandibular reconstruction type and extent (Cantor-Curtis classification) are unclear. This systematic review aims to assess the spectrum of prosthodontic rehabilitation approaches with regard to reconstruction type and extent of mandibular surgical defects. The databases incorporated for literature search were Google Scholar and Medline (PubMed). Relevant search terms for hemimandibulectomy and reconstruction with prosthetic rehabilitation were used. Two reviewers independently assessed the articles using eligibility criteria; published case reports and case series in the English language and depicting prosthodontic treatment modality of patients greater than 15 years were included. A total of 202 records were identified from the database search of which 19 duplicates were removed. The remaining articles were assessed for eligibility, and 55 articles (comprising 58 cases) were finally included in the study. This review revealed various prosthetic alternatives ranging from guide flange, twin occlusion, palatal ramp, conventional to hybrid partial and complete dentures to implant-supported prosthesis including a few innovative prosthetic approaches. This systematic review provides a plethora of prosthodontic rehabilitation approaches according to the extent of hemimandibular surgical defect and type of reconstruction. This will facilitate practitioners and prosthodontists in sequential treatment planning and management of hemimandibulectomy cases in their routine practice.
PubMed: 37799255
DOI: 10.7759/cureus.44647 -
Clinical Oral Implants Research Sep 2023To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on dental patient-reported outcomes (dPROs).
MATERIALS AND METHODS
In January 2022, Medline, Embase, CINAHL, Cochrane Library, PubMed Central, Web of Science, and ClinicalTrials.gov were screened for prospective clinical studies on completely edentulous patients treated with IFCDs and/or IODs, reporting pre-treatment and follow-up dPROs. Hedges' g effect sizes (ES) with corresponding 95% confidence intervals (CI) were calculated. Afterward, meta-analyses were conducted using random effect models.
RESULTS
A total number of 1608 records was initially identified. Of those, 28 studies reporting dPROs from 1457 patients were finally included. The applied dental patient-reported outcome measures (dPROMs) included several versions of the Oral Health Impact Profile (OHIP) or specific items assessing satisfaction with Visual Analogue Scales (VAS). The overall ES was large for rehabilitation with IFCDs (1.68 [CI: 1.15, 2.20]) and IODs (1.26 [CI: 0.99, 1.52]) with no significant difference (p = .165) between the two. Denture stability was the only factor rated significantly higher for IFCDs (ES difference: 2.37 [CI: 0.21, 4.54]; p = .032). Subgroup analyses revealed moderately higher ES for IODs on two implants relative to one implant (ES difference: 0.73 [CI: 0.34, 1.12]; p < .001).
CONCLUSIONS
There is a strong positive effect of implant treatment in edentulous patients, independent of the type of prosthetic rehabilitation. In patients seeking high stability, IFCDs may be preferable. In mandibular IODs on a single implant, there was a significantly positive effect of an additional implant on dPROs.
Topics: Humans; Denture, Overlay; Prospective Studies; Dental Implants; Denture, Complete; Mouth, Edentulous; Patient Reported Outcome Measures
PubMed: 37750530
DOI: 10.1111/clr.14065 -
BMC Oral Health Sep 2023Digital technologies have recently been introduced into the fabrication of removable partial dentures (RPDs). However, it is still unclear whether the digitally... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Digital technologies have recently been introduced into the fabrication of removable partial dentures (RPDs). However, it is still unclear whether the digitally fabricated RPDs fit better than conventionally cast ones in the rest region. The aim of this study was to evaluate the fit accuracy in the rest region of RPDs fabricated by digital technologies and compare it to those made by conventional lost-wax (CLW) technique.
METHODS
A comprehensive search was conducted in Cochrane Library, PubMed, EMbase, Web of Science and SpringerLink. Studies published up to August 2022 were collected. Two authors analyzed the studies independently and assessed the risk of bias on the modified methodological index for non-randomized studies (MINORS) scale. The mean values of gap distance between rests and corresponding rest seats of each study were extracted as outcome. A random-effects model at a significance level of P < 0.05 was used in the global comparison and subgroup analysis was carried out.
RESULTS
Overall, 11 articles out of 1214 complied with the inclusion criteria and were selected, including 2 randomized controlled trials (RCTs), 1 non-randomized clinical trial and 8 in vitro studies. Quantitative data from Meta-analysis revealed that fit accuracy in the rest region of RPDs fabricated with CLW showed no statistically significant difference with digital techniques (SMD = 0.33, 95%CI (-0.18, 0.83), P = 0.21). Subgroup analysis revealed a significantly better fit accuracy of CLW-fabricated RPDs in the rest region than either additive manufacturing (AM) groups or indirect groups (P = 0.03, P = 0.00), in which wax or resin patterns are milled or printed before conventional casting. While milled RPDs fit significantly better than cast ones in the rest region (P = 0.00). With digital relief and heat treatment, hybrid manufactured (HM) clasps obtained better fit accuracy in the rest region (P < 0.05). In addition, finishing and polishing procedure had no significant influence in the fit accuracy in all groups (P = 0.83).
CONCLUSIONS
RPDs fabricated by digital technologies exhibit comparable fit accuracy in rest region with those made by CLW. Digital technologies may be a promising alternative to CLW for the fabrication of RPDs and additional studies are recommended to provide stronger evidence.
TRIAL REGISTRATION
CRD42020201313.
Topics: Humans; Denture, Partial, Removable; Digital Technology; Research Design; Rest; Dental Casting Technique
PubMed: 37715159
DOI: 10.1186/s12903-023-03348-6 -
The Journal of Prosthetic Dentistry Sep 2023Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are... (Review)
Review
STATEMENT OF PROBLEM
Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are currently unknown.
PURPOSE
The purpose of this systematic review was to evaluate the clinical and laboratory procedures for digital complete dentures, their outcomes, and associated complications.
MATERIAL AND METHODS
Electronic literature searches were conducted on PubMed/Medline, Embase, and Web of Science for studies published from January 2000 to September 2022 and screened by 2 independent reviewers. Information on digital complete denture procedures, materials, their outcomes, and associated complications was extracted.
RESULTS
Of 266 screened studies, 39 studies were included. While 26 assessed definitive complete dentures, 7 studies assessed denture bases, 2 assessed trial dentures, and 4 assessed the digital images only. Twenty-four studies used border molded impression technique, 3 studies used a facebow record, and 7 studies used gothic arch tracing. Only 13 studies performed trial denture placement. Twenty-one studies used milling, and 17 studies used 3D printing for denture fabrication. One study reported that the retention of maxillary denture bases fabricated from a border-molded impression (14.5 to 16.1 N) was statistically higher than the retention of those fabricated from intraoral scanning (6.2 to 6.6 N). The maximum occlusal force of digital complete denture wearers was similar across different fabrication procedures. When compared with the conventional workflow, digital complete dentures required statistically shorter clinical time with 205 to 233 minutes saved. Up to 37.5% of participants reported loss of retention and up to 31.3% required a denture remake. In general, ≥1 extra visit and 1 to 4 unscheduled follow-up visits were needed. The outcomes for patient satisfaction and oral health-related quality of life were similar between conventional, milled, and 3D-printed complete dentures.
CONCLUSIONS
Making a border-molded impression is still preferred for better retention, and trial denture placement is still recommended to optimize the fabrication of definitive digital complete dentures.
PubMed: 37689573
DOI: 10.1016/j.prosdent.2023.07.027 -
Journal of Applied Oral Science :... 2023Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing... (Meta-Analysis)
Meta-Analysis
UNLABELLED
Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars.
OBJECTIVE
To evaluate the performance of IODs involving CAD-CAM bars.
METHODOLOGY
A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: "How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?" The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI).
RESULTS
Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies.
CONCLUSION
Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.
Topics: Humans; Denture, Overlay; Quality of Life; Titanium; Computer-Aided Design
PubMed: 37646715
DOI: 10.1590/1678-7757-2023-0054 -
Journal of Functional Biomaterials Aug 2023Partial or complete dentures are constructed from thermoplastic resins that are thermally processed and molded. This review examines the presently available evidence for... (Review)
Review
Partial or complete dentures are constructed from thermoplastic resins that are thermally processed and molded. This review examines the presently available evidence for the cytotoxicity of thermoplasticized denture base resins on human gingival epithelial cells, adipose cells, and fibroblasts; human amnion fibroblasts; and mouse fibroblasts. Electronic searches were performed on PubMed, Scopus, Web of Science, and Google Scholar databases to identify relevant articles to be included in the review until September 2022. Clinical, in vivo, and in vitro studies in English language were searched for. The quality of the studies was assessed using the Toxicological data Reliability Assessment tool (ToxRTool) developed by the European Commission's Joint Research Centre. GRADE assessment was used to evaluate the certainty of evidence. Seven in vitro studies were included in the review. The overall risk of bias was determined to be high, with the majority of studies assessed found to be reliable with restrictions or not reliable. Only two studies were considered reliable without restrictions based on ToxRTool assessment. The effect of thermoplastic denture base resins on viability and cell adherence of human gingival or amnion fibroblasts and mouse fibroblasts (L929s) is not significant. Conditioned media from unpolished specimens of resins were significantly more toxic to cultured cells than those from polished specimens. This may be of concern in cases of poor post-processing of dentures. Based on the limited evidence available, there is low-certainty evidence that thermoplastic denture base resins appear to be biocompatible and show insignificant cytotoxicity. Further well-designed trials adhering to standard reporting guidelines and using objective measures are necessary before outlining universal guidelines for best practice. Long-term in vivo and clinical assessment is necessary to corroborate laboratory findings with clinical outcomes. Denture base resins are in constant contact with oral tissues, and cytotoxic components released by the resins may irritate or inflame the tissues or provoke an allergic response.
PubMed: 37623656
DOI: 10.3390/jfb14080411