Photodiagnosis and Photodynamic Therapy Jun 2024This study aimed to assess the effectiveness of photobiomodulation therapy (PBM) in enhancing bone integration with dental implants. (Review)
Review
AIM
This study aimed to assess the effectiveness of photobiomodulation therapy (PBM) in enhancing bone integration with dental implants.
METHOD
PubMed, ScienceDirect, the Cochrane Library, Scopus, and Google Scholar were searched. Studies assessing PBM effectiveness with defined intervention/control groups were included, while those lacking specified laser types, involving severe maxillofacial defects or surgery, and not reporting outcomes related to dental implant osseointegration post-PBM therapy were excluded. The studies' risk of bias was assessed using Robvis for randomized controlled trials (RCTs) and ROBINS-I for non-RCTs. The meta-analysis was conducted utilizing a random-effects model at a significance level of 0.01.
RESULTS
The study reviewed 26 papers involving 571 patients undergoing dental implant procedures with PBM/Low-Level Laser Therapy (LLLT) or placebo/control. Implant stability quotients (ISQ) analysis showed a non-significant difference (p=0.06, mean difference: 1.02, 95% CI: 0.28 to 1.75, I=28%), while the Periotest method indicated significant improvement in stability (p<0.01, mean difference: -0.51, 95% CI: -0.78 to -0.24, I=71%). PBM resulted in a significant bone density increase (p<0.01, mean difference: 26, 95% CI: 6.93 to 45.06, I=91%), but marginal bone loss showed no significant difference (p=0.11, mean difference: 0.00, 95% CI: -0.06 to 0.05, I=45%). Implant survival rate did not significantly differ (p=0.73, mean difference: 1.56, 95% CI: 0.38 to 6.46, I=0%). Most studies raised concerns regarding randomization.
CONCLUSION
PBM could improve implant stability, as assessed with Periotest, and increase bone density, enhancing osseointegration. However, implant stability assessed with ISQ, marginal bone loss, and implant survival rate were comparable between the study groups.
PubMed: 38914185
DOI: 10.1016/j.pdpdt.2024.104256 -
Journal of Orthopaedic Surgery and... Jun 2024A systematic review and meta-analysis. (Meta-Analysis)
Meta-Analysis Comparative Study
Accuracy and postoperative assessment of robot-assisted placement of pedicle screws during scoliosis surgery compared with conventional freehand technique: a systematic review and meta-analysis.
STUDY DESIGN
A systematic review and meta-analysis.
BACKGROUND
The complexity of human anatomical structures and the variability of vertebral body structures in patients with scoliosis pose challenges in pedicle screw placement during spinal deformity correction surgery. Through technological advancements, robots have been introduced in spinal surgery to assist with pedicle screw placement.
METHODS
A systematic search was conducted using PubMed, Cochrane, Embase, and CNKI databases and comparative studies assessing the accuracy and postoperative efficacy of pedicle screw placement using robotic assistance or freehand techniques in patients with scoliosis were included. The analysis evaluated the accuracy of screw placement, operative duration, intraoperative blood loss, length of postoperative hospital stay, and complications.
RESULTS
Seven studies comprising 584 patients were included in the meta-analysis, with 282 patients (48.3%) in the robot-assisted group and 320 (51.7%) in the freehand group. Robot-assisted placement showed significantly better clinically acceptable screw placement results compared with freehand placement (odds ratio [OR]: 2.61, 95% confidence interval [CI]: 1.75-3.91, P < 0.0001). However, there were no statistically significant differences in achieving "perfect" screw placement between the two groups (OR: 1.52, 95% CI: 0.95-2.46, P = 0.08). The robot-assisted group had longer operation durations (mean deviation [MD]: 43.64, 95% CI: 22.25-64.74, P < 0.0001) but shorter postoperative hospital stays (MD: - 1.12, 95% CI: - 2.15 to - 0.08, P = 0.03) than the freehand group. There were no significant differences in overall complication rates or intraoperative blood loss between the two groups. There was no significant difference in Cobb Angle between the two groups before and after operation.
CONCLUSION
Robot-assisted pedicle screw placement offers higher accuracy and shorter hospital stay than freehand placement in scoliosis surgery; although the robotics approach is associated with longer operative durations, similar complication rates and intraoperative blood loss.
Topics: Scoliosis; Humans; Pedicle Screws; Robotic Surgical Procedures; Length of Stay; Postoperative Complications; Spinal Fusion; Blood Loss, Surgical; Operative Time; Treatment Outcome; Postoperative Period
PubMed: 38902785
DOI: 10.1186/s13018-024-04848-z -
Maxillofacial Plastic and... Jun 2024Focal and florid cemento-osseous dysplasia are benign fibro-osseous lesions affecting the quality and quantity of the jawbones. This study aimed to determine the... (Review)
Review
BACKGROUND
Focal and florid cemento-osseous dysplasia are benign fibro-osseous lesions affecting the quality and quantity of the jawbones. This study aimed to determine the viability of implant-based approaches in the affected patients.
MAIN TEXT
Different scientific databases, including PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, and Google Scholar, were searched until October 8, 2023, using a pre-determined search strategy. Two reviewers screened the retrieved reports and extracted the required information from the included studies. The eligibility criteria included English-language case reports/series or clinical trials. The JBI critical appraisal checklist for case reports was used to assess the methodological quality of the included studies. Three studies were deemed eligible to be included in this study out of the initial 202 records found. Five implants were placed in three patients, positioned in the proximity of the lesion area, without any additional treatment to remove the pathology. The mandibular posterior area was the affected site in all patients. Only one implant failed in one patient after 16 years, which was attributed to peri-implantitis and not the lesion. Other implants demonstrated successful maintenance over follow-up periods.
CONCLUSIONS
Although the number of the included records was relatively low to draw firm conclusions, it seems that implant-based treatments in patients with focal/florid cemento-osseous dysplasia could be viable, considering a conservative and well-planned approach.
PubMed: 38900334
DOI: 10.1186/s40902-024-00432-x -
Journal of Orthopaedic Surgery and... Jun 2024In recent years, the zero-profile implant (Zero-p) has emerged as a promising internal fixation technique. Although studies have indicated its potential superiority over... (Meta-Analysis)
Meta-Analysis Comparative Study
Comparative efficacy of zero-profile implant and conventional cage-plate implant in the treatment of single-level degenerative cervical spondylosis: a systematic review and meta-analysis.
BACKGROUND
In recent years, the zero-profile implant (Zero-p) has emerged as a promising internal fixation technique. Although studies have indicated its potential superiority over conventional cage-plate implant (Cage-plate) in the treatment of degenerative cervical spondylosis, there remains a lack of definitive comparative reports regarding its indications, safety, and efficacy.
METHODS
A computerized search was conducted on English and Chinese databases, including PubMed, Web of Science, Cochrane Library, EMBASE, CNKI, Wanfang and VIP. Additionally, a manual search was meticulously carried out on Chinese medical journals, spanning from the inception of the respective databases until August 2023. The meta-analysis utilized a case-control study approach and was executed through the utilization of RevMan 5.3 software. Stringent quality evaluation and data extraction procedures were implemented to guarantee the reliability and validity of the findings.
RESULTS
Nine high-quality studies with 808 patients were included. Meta-analysis showed that the operation time (MD = - 13.28; 95% CI (- 17.53, - 9.04), P < 0.00001), intraoperative blood loss (MD = - 6.61; 95% CI (- 10.47, - 2.75), P = 0.0008), incidence of postoperative dysphagia at various time points: within the first month after surgery (OR = 0.36; 95% CI (0.22, 0.58), P < 0.0001), 1-3 months after surgery (OR = 0.20; 95% CI (0.08, 0.49), P = 0.0004), the final follow-up (OR = 0.21; 95% CI (0.05, 0.83), P = 0.003) and the rate of postoperative adjacent disc degeneration (OR = 0.46; 95% CI (0.25, 0.84), P = 0.01) were significantly lower in the Zero-p group than in the Cage-plate group. Additionally, was also significantly lower in the Zero-p group. However, there were no significant differences in the JOA score, the final follow-up NDI score, surgical segmental fusion rate, postoperative height of adjacent vertebrae, or postoperative subsidence rate between the two groups.
CONCLUSION
In summary, when treating single-segment degenerative cervical spondylosis, both internal fixation techniques are reliable and effective. However, Zero-P implant offer several advantages over cage-plate implant, including shorter operation duration, less intraoperative blood loss, reduced postoperative dysphagia, and slower adjacent disc degeneration. Additionally, Zero-P implant has a broader application space, making them a preferred choice in certain cases.
Topics: Humans; Cervical Vertebrae; Spondylosis; Bone Plates; Treatment Outcome; Postoperative Complications; Operative Time; Spinal Fusion; Male; Blood Loss, Surgical; Female; Internal Fixators
PubMed: 38898517
DOI: 10.1186/s13018-024-04729-5 -
Acta Odontologica Scandinavica Jun 2024To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for...
OBJECTIVES
To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for patients with partial or total maxillary and mandibular defects.
MATERIALS AND METHODS
An electronic search was performed in PubMed, SCOPUS, and Web of Science using a combination of relevant keywords: digital workflow, digital designing, computer-assisted design-computer aided manufacturing, 3D printing, maxillectomy, and mandibulectomy. The Joanna Briggs Institute Critical Appraisal Tool was used to assess the quality of evidence in the studies reviewed.
RESULTS
From a total of 542 references, 33 articles were selected, including 25 on maxillary prostheses and 8 on mandibular prostheses. The use of digital workflows was limited to one or two steps of the fabrication of the prostheses, and only four studies described a complete digital workflow. The most preferred method for data acquisition was intraoral scanning with or without a cone beam computed tomography combination.
CONCLUSION
Currently, the fabrication process of maxillofacial prostheses requires combining digital and conventional methods. Simplifying the data acquisition methods and providing user-friendly and affordable software may encourage clinicians to use the digital workflow more frequently for patients requiring maxillofacial prostheses.
Topics: Humans; Workflow; Maxillofacial Prosthesis; Computer-Aided Design; Feasibility Studies; Printing, Three-Dimensional; Software; Prosthesis Design
PubMed: 38895776
DOI: 10.2340/aos.v83.40870 -
Clinical Cardiology Jun 2024Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally,... (Comparative Study)
Comparative Study Meta-Analysis
Temporal Trends in the Outcomes of Percutaneous Coronary Intervention With Zotarolimus Eluting Stents Versus Everolimus Eluting Stents: A Meta-Analysis of Randomized Controlled Trials.
INTRODUCTION
Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally, over the last decade, there have been new trials comparing the ZES with various commercially available EES. We aim to conduct an updated meta-analysis in light of new evidence from randomized controlled trials (RCTs) to provide comprehensive evidence regarding the temporal trends in the clinical outcomes.
METHODS
A comprehensive literature search was conducted across PubMed, Cochrane, and Embase. RCTs comparing ZES with EES for short (<2 years), intermediate (2-3 years), and long-term follow-ups (3-5 years) were included. Relative risk was used to pool the dichotomous outcomes using the random effects model employing the inverse variance method. All statistical analysis was conducted using Revman 5.4.
RESULTS
A total of 18 studies reporting data at different follow-ups for nine trials (n = 14319) were included. At short-term follow-up (<2 years), there were no significant differences between the two types of stents (all-cause death, cardiac death, Major adverse cardiovascular events (MACE), target vessel myocardial infarction, definite or probable stent thrombosis or safety outcomes (target vessel revascularization, target lesion revascularization, target vessel failure, target lesion failure). At intermediate follow-up (2-3 years), EES was superior to ZES for reducing target lesion revascularization (RR = 1.28, 95% CI = 1.05-1.58, p < 0.05). At long-term follow-up (3-5 years), there were no significant differences between the two groups for any of the pooled outcomes (p > 0.05).
CONCLUSION
ZES and EES have similar safety and efficacy at short, intermediate, and long-term follow-ups.
Topics: Humans; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Risk Factors; Sirolimus; Time Factors; Treatment Outcome
PubMed: 38888152
DOI: 10.1002/clc.24306 -
BMC Pulmonary Medicine Jun 2024Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential...
BACKGROUND
Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential harms of rapamycin-eluting stents. Herein, We report a case of eosinophilia and interstitial pneumonia caused by a cobalt-based alloy stent eluted with rapamycin.
CASE PRESENTATION
The patient was admitted due to fever, cough, and expectoration symptoms. Previously, the patient had undergone a procedure of percutaneous coronary stent implantation in our hospital's cardiology department, which led to a gradual rise in blood eosinophil count. This time, the eosinophil count was higher than the previous admission. A chest CT scan revealed multiple flocculent density increases in both lungs and bronchiectasis. The rapamycin-eluting stents may have caused eosinophilia and interstitial pneumonia, which improved after administering corticosteroids. A systematic review of relevant literature was conducted to summarize the characteristics of interstitial pneumonia caused by drug-eluting stents.
CONCLUSION
Paclitaxel, everolimus, zotarolimus, and rapamycin are the types of drugs that can lead to drug-eluting stents, and because of the rarity of their onset, clinical doctors must be precise and prompt in diagnosing suspected cases to avoid misdiagnosis and delayed treatment.
Topics: Humans; Lung Diseases, Interstitial; Drug-Eluting Stents; Sirolimus; Eosinophilia; Male; Tomography, X-Ray Computed; Percutaneous Coronary Intervention; Aged
PubMed: 38886703
DOI: 10.1186/s12890-024-03101-x -
Frontiers in Cardiovascular Medicine 2024In recent years, the use of artificial intelligence (AI) models to generate individualised risk assessments and predict patient outcomes post-Transcatheter Aortic Valve...
OBJECTIVES
In recent years, the use of artificial intelligence (AI) models to generate individualised risk assessments and predict patient outcomes post-Transcatheter Aortic Valve Implantation (TAVI) has been a topic of increasing relevance in literature. This study aims to evaluate the predictive accuracy of AI algorithms in forecasting post-TAVI mortality as compared to traditional risk scores.
METHODS
Following the Preferred Reporting Items for Systematic Reviews and Meta-analyses for Systematic Reviews (PRISMA) standard, a systematic review was carried out. We searched four databases in total-PubMed, Medline, Embase, and Cochrane-from 19 June 2023-24 June, 2023.
RESULTS
From 2,239 identified records, 1,504 duplicates were removed, 735 manuscripts were screened, and 10 studies were included in our review. Our pooled analysis of 5 studies and 9,398 patients revealed a significantly higher mean area under curve (AUC) associated with AI mortality predictions than traditional score predictions (MD: -0.16, CI: -0.22 to -0.10, < 0.00001). Subgroup analyses of 30-day mortality (MD: -0.08, CI: -0.13 to -0.03, = 0.001) and 1-year mortality (MD: -0.18, CI: -0.27 to -0.10, < 0.0001) also showed significantly higher mean AUC with AI predictions than traditional score predictions. Pooled mean AUC of all 10 studies and 22,933 patients was 0.79 [0.73, 0.85].
CONCLUSION
AI models have a higher predictive accuracy as compared to traditional risk scores in predicting post-TAVI mortality. Overall, this review demonstrates the potential of AI in achieving personalised risk assessment in TAVI patients.
REGISTRATION AND PROTOCOL
This systematic review and meta-analysis was registered under the International Prospective Register of Systematic Reviews (PROSPERO), under the registration name "All-Cause Mortality in Transcatheter Aortic Valve Replacement Assessed by Artificial Intelligence" and registration number CRD42023437705. A review protocol was not prepared. There were no amendments to the information provided at registration.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/, PROSPERO (CRD42023437705).
PubMed: 38883982
DOI: 10.3389/fcvm.2024.1343210 -
BMC Cardiovascular Disorders Jun 2024Stent restenosis is a relatively common phenomenon among patients with coronary heart disease undergoing percutaneous coronary intervention (PCI). It seems that a set of...
BACKGROUND
Stent restenosis is a relatively common phenomenon among patients with coronary heart disease undergoing percutaneous coronary intervention (PCI). It seems that a set of clinical, laboratory, and even genetic factors make people susceptible to such a phenomenon and in fact, this is multi-factorial. We aimed to first determine the underlying clinical and laboratory risk factors for the occurrence of stent re-stenosis after PCI based on a systematic review study, and after that, through a bioinformatics study, to evaluate the related genes and microRNAs with the occurrence of stent re-stenosis.
MAIN TEXT
In the first step, the manuscript databases including Medline, Web of Knowledge, Google Scholar, Scopus, and Cochrane were deeply searched by the two blinded investigators for all eligible studies based on the considered keywords to introduce clinical and laboratory determinants of stent re-stenosis. In the bioinformatic phase, and following a review of the literature to identify genes and microRNAs involved in restenosis, the interaction of each gene with other genes associated with stent re-stenosis was determined by GeneMANIA network analysis and Cytoscape software. Overall, 67 articles (including 40,789 patients) on clinical and biochemical predictors for stent restenosis and 25 articles on genetic determinants of this event were eligible for the final analysis. The predictors for this event were categorized into four subgroups patient-based parameters including traditional cardiovascular risk profiles, stent-based parameters including type and diametric characteristics of the stents used, coronary lesion-based parameters including several two target lesions and coronary involvement severity and laboratory-based parameters particularly related to activation of inflammatory processes. In the bioinformatic phase, we uncovered 42 genes that have been described to be involved in such a phenomenon considering a special position for genes encoding inflammatory cytokines. Also, 12 microRNAs have been pointed to be involved in targeting genes involved in stent re-stenosis.
CONCLUSIONS
The incidence of stent re-stenosis will be the result of a complex interaction of clinical risk factors, laboratory factors mostly related to the activation of inflammatory processes, and a complex network of gene-to-gene interactions.
Topics: Humans; Percutaneous Coronary Intervention; Coronary Restenosis; Stents; Risk Factors; Computational Biology; Coronary Artery Disease; MicroRNAs; Risk Assessment; Genetic Predisposition to Disease; Treatment Outcome; Female; Male; Gene Regulatory Networks; Middle Aged; Aged
PubMed: 38877398
DOI: 10.1186/s12872-024-03955-3 -
Cirugia Y Cirujanos 2024The effect of a pre-operative biliary stent on complications after pancreaticoduodenectomy (PD) remains controversial. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
The effect of a pre-operative biliary stent on complications after pancreaticoduodenectomy (PD) remains controversial.
MATERIALS AND METHOD
We conducted a meta-analysis according to the preferred reporting items for systematic reviews and meta-analyses guidelines, and PubMed, Web of Science Knowledge, and Ovid's databases were searched by the end of February 2023. 35 retrospective studies and 2 randomized controlled trials with a total of 12641 patients were included.
RESULTS
The overall complication rate of the pre-operative biliary drainage (PBD) group was significantly higher than the no-PBD group (odds ratio [OR] 1.46, 95% confidence interval [CI] 1.22-1.74; p < 0.0001), the incidence of post-operative delayed gastric emptying was increased in patients with PBD compared those with early surgery (OR 1.21, 95% CI: 1.02-1.43; p = 0.03), and there was a significant increase in post-operative wound infections in patients receiving PBD with an OR of 2.2 (95% CI: 1.76-2.76; p < 0.00001).
CONCLUSIONS
PBD has no beneficial effect on post-operative outcomes. The increase in post-operative overall complications and wound infections urges the exact indications for PBD and against routine pre-operative biliary decompression, especially for patients with total bilirubin < 250 umol/L waiting for PD.
Topics: Humans; Drainage; Pancreaticoduodenectomy; Preoperative Care; Postoperative Complications; Stents; Surgical Wound Infection; Randomized Controlled Trials as Topic; Gastric Emptying; Ampulla of Vater; Pancreatic Neoplasms; Common Bile Duct Neoplasms
PubMed: 38862121
DOI: 10.24875/CIRU.23000318