Journal of Clinical Hypertension... Jun 2024The aim of this study was to evaluate the accuracy of the single upper-arm cuff oscillometric blood pressure (BP) monitor RBP-9801 developed for office and home BP...
Validation of the RBP-9801 oscillometric blood pressure monitor in the general population according to the association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard.
The aim of this study was to evaluate the accuracy of the single upper-arm cuff oscillometric blood pressure (BP) monitor RBP-9801 developed for office and home BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. A total of 105 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.3 ± 6.4/3.1 ± 5.8 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.24/5.03 mmHg (systolic/diastolic). The conclusion is that the RBP-9801 oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in the general population and can be recommended for clinic and self-use at home.
Topics: Humans; Male; Female; Middle Aged; Oscillometry; Hypertension; Blood Pressure Determination; Adult; Blood Pressure Monitors; Blood Pressure; Aged; Blood Pressure Monitoring, Ambulatory; Reproducibility of Results
PubMed: 38650108
DOI: 10.1111/jch.14812 -
The Lancet. Child & Adolescent Health Jun 2024Early life is a key period that determines long-term health. Lung development in childhood predicts lung function attained in adulthood and morbidity and mortality...
BACKGROUND
Early life is a key period that determines long-term health. Lung development in childhood predicts lung function attained in adulthood and morbidity and mortality across the life course. We aimed to assess the effect of early-life lower respiratory tract infection (LRTI) and associated risk factors on lung development from birth to school age in a South African birth cohort.
METHODS
We prospectively followed children enrolled in a population-based cohort from birth (between March 5, 2012 and March 31, 2015) to age 5 years with annual lung function assessment. Data on multiple early-life exposures, including LRTI, were collected. The effect of early-life risk factors on lung function development from birth to age 5 years was assessed using the Generalised Additive Models for Location, Scale and Shape and Interrupted Time Series approach.
FINDINGS
966 children (475 [49·2%] female, 491 [50·8%] male) had lung function measured with oscillometry, tidal flow volume loops, and multiple breath washout. LRTI occurred in 484 (50·1%) children, with a median of 2·0 LRTI episodes (IQR 1·0-3·0) per child. LRTI was independently associated with altered lung function, as evidenced by lower compliance (0·959 [95% CI 0·941-0·978]), higher resistance (1·028 [1·016-1·041]), and higher respiratory rate (1·018 [1·063-1·029]) over 5 years. Additional impact on lung function parameters occurred with each subsequent LRTI. Respiratory syncytial virus (RSV) LRTI was associated with lower expiratory flow ratio (0·97 [0·95-0·99]) compared with non-RSV LRTI. Maternal factors including allergy, smoking, and HIV infection were also associated with altered lung development, as was preterm birth, low birthweight, female sex, and coming from a less wealthy household.
INTERPRETATION
Public health interventions targeting LRTI prevention, with RSV a priority, are vital, particularly in low-income and middle-income settings.
FUNDING
UK Medical Research Council Grant, The Wellcome Trust, The Bill & Melinda Gates Foundation, US National Institutes of Health Human Heredity and Health in Africa, South African Medical Research Council, Hungarian Scientific Research Fund, and European Respiratory Society.
Topics: Humans; Female; South Africa; Male; Child, Preschool; Lung; Infant; Infant, Newborn; Risk Factors; Respiratory Function Tests; Respiratory Tract Infections; Prospective Studies; Interrupted Time Series Analysis; Birth Cohort
PubMed: 38621408
DOI: 10.1016/S2352-4642(24)00072-5 -
Journal of Clinical Medicine Mar 2024: Oscillometry allows for the non-invasive measurements of lung mechanics. In COVID-19 ARDS patients treated with Non-Invasive Oxygen Support (NI-OS), we aimed to (1)...
: Oscillometry allows for the non-invasive measurements of lung mechanics. In COVID-19 ARDS patients treated with Non-Invasive Oxygen Support (NI-OS), we aimed to (1) observe lung mechanics at the patients' admission and their subsequent changes, (2) compare lung mechanics with clinical and imaging data, and (3) evaluate whether lung mechanics helps to predict clinical outcomes. : We retrospectively analyzed the data from 37 consecutive patients with moderate-severe COVID-19 ARDS. Oscillometry was performed on their 1st, 4th, and 7th day of hospitalization. Resistance (R5), reactance (X5), within-breath reactance changes (ΔX5), and the frequency dependence of the resistance (R5-R19) were considered. Twenty-seven patients underwent computed tomographic pulmonary angiography (CTPA): collapsed, poorly aerated, and normally inflated areas were quantified. Adverse outcomes were defined as intubation or death. : Thirty-two patients were included in this study. At the first measurement, only 44% of them had an abnormal R5 or X5. In total, 23 patients had measurements performed on their 3rd day and 7 on their 7th day of hospitalization. In general, their R5, R5-R19, and ΔX decreased with time, while their X5 increased. Collapsed areas on the CTPA correlated with the X5 z-score (ρ = -0.38; = 0.046), while poorly aerated areas did not. Seven patients had adverse outcomes but did not present different oscillometry parameters on their 1st day of hospitalization. : Our study confirms the feasibility of oscillometry in critically ill patients with COVID-19 pneumonia undergoing NI-OS. The X5 z-scores indicates collapsed but not poorly aerated lung areas in COVID-19 pneumonia. Our data, which show a severe impairment of gas exchange despite normal reactance in most patients with COVID-19 ARDS, support the hypothesis of a composite COVID-19 ARDS physiopathology.
PubMed: 38610633
DOI: 10.3390/jcm13071868 -
Journal of Veterinary Internal Medicine 2024Salbutamol and hyoscine butylbromide (HBB) are commonly used bronchodilators in horses with severe asthma (SA). (Comparative Study)
Comparative Study
BACKGROUND
Salbutamol and hyoscine butylbromide (HBB) are commonly used bronchodilators in horses with severe asthma (SA).
OBJECTIVE
To compare the bronchodilation potency, duration, and adverse effects of salbutamol and HBB in SA.
ANIMALS
Six horses in exacerbation of SA.
METHODS
The effects of inhaled salbutamol (1000 μg) and HBB (150 mg, IV) were compared in a randomized, blinded, crossover experiment. Lung function, intestinal borborygmi and heart rate were assessed before and sequentially until 180 minutes after drug administration, and analyzed with 2-way repeated-measures ANOVA and Dunnett's multiple comparison tests.
RESULTS
Both treatments caused a similar improvement in lung function. Pulmonary resistance and reactance returned to baseline values within 30 minutes after HBB administration, whereas salbutamol improved reactance until 180 minutes (mean improvement at 180 minutes of 0.040 Kpa/L/s, 95% CI = 0.004 to 0.076; P = .02 for salbutamol and of 0.009 Kpa/L/s, 95% CI = -0.028 to 0.045; P = .98 for HBB for the resistance at 3 Hz and of 0.040 Kpa/L/s, 95% CI = 0.007 to 0.074; P = .01 for salbutamol and of 0.009 Kpa/L/s, 95% CI = -0.024 to 0.042; P = .97 for HBB for the reactance at 7 Hz). From 5 to 30 minutes after HBB administration, the heart rate accelerated (mean increase of 3.3 beats per minute, 95% CI = -6.6 to 13.1; P = .92 for salbutamol, and of 13.0 beats per minute, 95% CI = 3.6 to 22.4; P = .002 for HBB at 30 minutes) and the gut sounds decreased (mean reduction of 1.3, 95% CI = -0.1 to 2.8; P = .09 for salbutamol and of 2.8 for the gastrointestinal auscultation score, 95% CI = 1.4 to 4.3; P < .0001 for HBB at 30 minutes).
CONCLUSIONS AND CLINICAL IMPORTANCE
Both drugs have a similar bronchodilator potency but with a longer duration for salbutamol. Gastrointestinal and cardiovascular effects were noted only with HBB, suggesting the preferential use of salbutamol to relieve bronchoconstriction in horses with asthma.
Topics: Animals; Horses; Albuterol; Asthma; Horse Diseases; Bronchodilator Agents; Cross-Over Studies; Butylscopolammonium Bromide; Male; Female; Heart Rate; Administration, Inhalation
PubMed: 38609079
DOI: 10.1111/jvim.17057 -
Respiratory Medicine Case Reports 2024Oscillometry is an emerging pulmonary function testing tool that is conducted during tidal breaths with minimal patient effort. It is highly sensitive to changes in lung...
Oscillometry is an emerging pulmonary function testing tool that is conducted during tidal breaths with minimal patient effort. It is highly sensitive to changes in lung mechanics. Oscillometry was recently shown to be highly associated with disease severity in idiopathic pulmonary fibrosis (IPF). The usefulness of oscillometry after single lung transplant in IPF patients is not well understood. Our study demonstrated that oscillometry can detect changes in the graft despite presence of a native fibrotic lung to provide useful information to complement spirometry.
PubMed: 38559325
DOI: 10.1016/j.rmcr.2024.102016 -
Clinical Hypertension Apr 2024Hypertension is the leading cause of morbidity and mortality worldwide. Hypertension mostly accompanies no symptoms, and therefore blood pressure (BP) measurement is the... (Review)
Review
Hypertension is the leading cause of morbidity and mortality worldwide. Hypertension mostly accompanies no symptoms, and therefore blood pressure (BP) measurement is the only way for early recognition and timely treatment. Methods for BP measurement have a long history of development and improvement. Invasive method via arterial cannulation was first proven possible in the 1800's. Subsequent scientific progress led to the development of the auscultatory method, also known as Korotkoff' sound, and the oscillometric method, which enabled clinically available BP measurement. However, hypertension management status is still poor. Globally, less than half of adults are aware of their hypertension diagnosis, and only one-third of them being treated are under control. Novel methods are actively investigated thanks to technological advances such as sensors and machine learning in addition to the clinical needs for easier and more convenient BP measurement. Each method adopts different technologies with its own specific advantages and disadvantages. Promises of novel methods include comprehensive information on out-of-office BP capturing dynamic short-term and long-term fluctuations. However, there are still pitfalls such as the need for regular calibration since most novel methods capture relative BP changes rather than an absolute value. In addition, there is growing concern on their accuracy and precision as conventional validation protocols are inappropriate for cuffless continuous methods. In this article, we provide a comprehensive overview of the past and present of BP measurement methods. Novel and emerging technologies are also introduced with respect to their potential applications and limitations.
PubMed: 38556854
DOI: 10.1186/s40885-024-00268-7 -
Respiratory Research Mar 2024The clinical significance of the impulse oscillometry-defined small airway bronchodilator response (IOS-BDR) is not well-known. Accordingly, this study investigated the...
BACKGROUND
The clinical significance of the impulse oscillometry-defined small airway bronchodilator response (IOS-BDR) is not well-known. Accordingly, this study investigated the clinical characteristics of IOS-BDR and explored the association between lung function decline, acute respiratory exacerbations, and IOS-BDR.
METHODS
Participants were recruited from an Early Chronic Obstructive Pulmonary Disease (ECOPD) cohort subset and were followed up for two years with visits at baseline, 12 months, and 24 months. Chronic obstructive pulmonary disease (COPD) was defined as a post-bronchodilator forced expiratory volume in 1 s (FEV)/forced vital capacity (FVC) ratio < 0.70. IOS-BDR was defined as meeting any one of the following criteria: an absolute change in respiratory system resistance at 5 Hz ≤ - 0.137 kPa/L/s, an absolute change in respiratory system reactance at 5 Hz ≥ 0.055 kPa/L/s, or an absolute change in reactance area ≤ - 0.390 kPa/L. The association between IOS-BDR and a decline in lung function was explored with linear mixed-effects model. The association between IOS-BDR and the risk of acute respiratory exacerbations at the two-year follow-up was analyzed with the logistic regression model.
RESULTS
This study involved 466 participants (92 participants with IOS-BDR and 374 participants without IOS-BDR). Participants with IOS-BDR had higher COPD assessment test and modified Medical Research Council dyspnea scale scores, more severe emphysema, air trapping, and rapid decline in FVC than those without IOS-BDR over 2-year follow-up. IOS-BDR was not associated with the risk of acute respiratory exacerbations at the 2-year follow-up.
CONCLUSIONS
The participants with IOS-BDR had more respiratory symptoms, radiographic structural changes, and had an increase in decline in lung function than those without IOS-BDR.
TRIAL REGISTRATION
Chinese Clinical Trial Registry, ChiCTR1900024643. Registered on 19 July, 2019.
Topics: Humans; Asthma; Bronchodilator Agents; Forced Expiratory Volume; Oscillometry; Pulmonary Disease, Chronic Obstructive; Respiratory Function Tests; Spirometry
PubMed: 38555433
DOI: 10.1186/s12931-024-02765-7 -
Journal of Clinical Hypertension... May 2024This study evaluated an oscillometric device (OD), Microlife WatchBP Office AFIB, and a hybrid manual auscultatory device (AD), Greenlight 300TM, to determine a suitable... (Comparative Study)
Comparative Study
This study evaluated an oscillometric device (OD), Microlife WatchBP Office AFIB, and a hybrid manual auscultatory device (AD), Greenlight 300TM, to determine a suitable blood pressure (BP) measurement device for the Korea National Health and Nutrition Examination Survey in a mercury-free context. Adhering to the 2018 Universal Standard's suggested consensus, the study involved 800 subjects (mean age 51.2 ± 17.5 years; 44.3% male), who underwent triplicate BP measurements following 5 min of rest in a randomized order (OD-first: 398 participants; AD-first: 402 participants). BP difference was calculated as OD value minus AD value, with results stratified by measurement sequence. The overall BP difference and tolerable error probability were -1.1 ± 6.5/-2.6 ± 4.9 mmHg and 89.2%/92.5% for systolic/diastolic BP (SBP/DBP), respectively. Lin's concordance correlation coefficient was 0.907/0.844 for SBP/DBP (OD-first/AD-first: 0.925/0.892 for SBP, 0.842/0.845 for DBP). The overall agreement for hypertension (BP ≥ 140 and/or 90 mmHg) was 0.71 (p < 0.0001), and the OD underestimated the overall hypertension prevalence by 5.1%. Analysis of the AD-first data revealed a lower level of agreement compared to the OD-first data; however, the observed blood pressure difference adhered to Criterion 1 of the 2018 Universal Standard. Microlife met the Criterion 1 of 2018 Universal Standard but underestimated the prevalence of hypertension. The BP discrepancy increased with higher BP levels, male sex, and smaller AC. With increasing age, the discrepancy decreased for SBP and increased for DBP.
Topics: Humans; Male; Middle Aged; Female; Republic of Korea; Nutrition Surveys; Blood Pressure Determination; Adult; Oscillometry; Aged; Auscultation; Hypertension; Blood Pressure; Reproducibility of Results
PubMed: 38552166
DOI: 10.1111/jch.14805 -
Journal of Feline Medicine and Surgery Mar 2024Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are...
OBJECTIVES
Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats.
METHODS
In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed.
RESULTS
There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP.
CONCLUSIONS AND RELEVANCE
Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.
Topics: Cats; Animals; Blood Pressure; Ultrasonics; Oscillometry; Prospective Studies; Blood Pressure Determination
PubMed: 38546192
DOI: 10.1177/1098612X241231471 -
The Journal of Allergy and Clinical... May 2024Disease of the peripheral (or small) airways is fundamental in asthma, being closely related to symptoms (or lack of control of them), airway hyperresponsiveness,...
Disease of the peripheral (or small) airways is fundamental in asthma, being closely related to symptoms (or lack of control of them), airway hyperresponsiveness, spirometric abnormalities, risk of loss of control, or exacerbations and inflammation. Current technology now allows routine measurement of peripheral airway function. Having a working concept of peripheral airways disease in asthma is arguably very useful to clinicians and beneficial to patients because it allows a more comprehensive assessment of asthma severity (rather than just symptoms alone, which is the norm), tracking of progress or deterioration, and assessing response to treatment. Oscillometry is a sensitive way to monitor the peripheral airways, whereas multiple breath nitrogen washout parameters are excellent measures of future risk. In the longer term, physiologic measurements will be crucial in research to define causes and find new disease-modifying treatments.
PubMed: 38544576
DOI: 10.1016/j.jacig.2024.100228