-
Cancers Aug 2023Prostate motion (standard deviation, range of motion, and diffusion coefficient) was calculated from 4D ultrasound data of 1791 fractions of radiation therapy in N = 100...
Prostate motion (standard deviation, range of motion, and diffusion coefficient) was calculated from 4D ultrasound data of 1791 fractions of radiation therapy in N = 100 patients. The inner diameter of the lesser pelvis was obtained from transversal slices through the pubic symphysis in planning CTs. On the lateral and craniocaudal axes, motility increases significantly (-test, < 0.005) with the inner diameter of the lesser pelvis. A diameter of >106 mm (ca. 6th decile) is a good predictor for high prostate intrafraction motion (ca. 9th decile). The corresponding area under the receiver operator curve (AUROC) is 80% in the lateral direction, 68% to 80% in the craniocaudal direction, and 62% to 70% in the vertical direction. On the lateral x-axis, the proposed test is 100% sensitive and has a 100% negative predictive value for all three characteristics (standard deviation, range of motion, and diffusion coefficient). On the craniocaudal z-axis, the proposed test is 79% to 100% sensitive and reaches 95% to 100% negative predictive value. On the vertical axis, the proposed test still delivers 98% negative predictive value but is not particularly sensitive. Overall, the proposed predictor is able to help identify patients at risk of high prostate motion based on a single planning CT.
PubMed: 37627131
DOI: 10.3390/cancers15164103 -
Research and Reports in Urology 2023The vascular supply of the pelvic structures and the external genitalia can be easily injured during the one-stage delayed bladder closure and radical soft-tissue...
Indocyanine Green (ICG)-Guided One-Stage Delayed Bladder Closure and Radical Soft-Tissue Mobilization (Kelly Procedure) For Bladder Exstrophy Repair: The First Experience.
The vascular supply of the pelvic structures and the external genitalia can be easily injured during the one-stage delayed bladder closure and radical soft-tissue mobilization (Kelly procedure) for bladder exstrophy surgical repair. Aiming to help surgeons assessing and confirming tissue perfusion and viability, indocyanine green (ICG)-based laser angiography was incorporated into the operative approach to reduce the risk of ischemic injuries. The EleVision IR system (Medtronic Ltd) was adopted to confirm the identification of the vascular pedicles and assess the tissue perfusion in real-time in a 5-month-old with bladder exstrophy undergoing the one-stage delayed bladder closure and radical soft-tissue mobilization (Kelly procedure). ICG (0.15 mg/kg) was intravenously administered at 6 key steps during surgery with the ability to be re-dosed every 15 minutes. ICG-based laser angiography helped to confirm the correct identification of the vascular structures during surgery and to assess tissue perfusion in real-time. Blood flow did not change considerably after initial dissection or upon approximating the pubis symphysis. At the end of the procedure, good penile perfusion was shown, proving that no direct injury or substantial compression of the pudendal vessels had occurred following the mobilization and the reconstructive phase. ICG-based laser angiography proved to be safe, effective, and easy to employ and should be considered as a reasonable adjunct for tissue perfusion assessment and operative decision-making in patients undergoing bladder exstrophy Kelly repair.
PubMed: 37581016
DOI: 10.2147/RRU.S423521 -
Journal of Clinical Medicine Jul 2023Open reduction and reconstruction plate and screws fixation (RPSF) is considered the gold standard for the treatment of traumatic symphysis pubis diastasis (SPD).... (Review)
Review
Percutaneous Fixation for Traumatic Symphysis Pubis Disruption-Are the Results Superior Compared to Open Techniques? A Systematic Review and Meta-Analysis of Clinical and Biomechanical Outcomes.
INTRODUCTION
Open reduction and reconstruction plate and screws fixation (RPSF) is considered the gold standard for the treatment of traumatic symphysis pubis diastasis (SPD). Percutaneous cannulated screw fixation (PCSF) has recently gained popularity as it may reduce operative time and morbidity. The current systematic review aims to compare the clinical and radiological outcomes of PCSF and RPSF in traumatic SPD and analyze the biomechanical effectiveness of PCSF.
MATERIAL AND METHODS
The Medline, Scopus, and Cochrane databases were searched until February 2023. The primary outcomes were the incidence of implant failure and revision surgery and the amount of displacement of symphysis pubis. Secondary outcomes were the intraoperative blood loss, the scar length, the operative time, the wound infection, and the patients' functional improvement.
RESULTS
Six clinical trial studies with a total of 184 patients and nine biomechanical studies were included. There was no significant difference between the two groups regarding the incidence of implant failure, the prevalence of revision surgery, and the amount of postoperative loss of reduction ( > 0.05 for all outcomes). The intraoperative blood loss (14.9 ± 4.2 mL for PCSF versus 162.7 ± 47.6 mL for PCSF, < 0.001) and the incision length (1.7 ± 0.9 mL for PCSF versus 8 ± 1.4 mL for PCSF, < 0.001) were significantly lower after PCSF. The mean operative time was 37 ± 19.1 min for PCSF and 68.9 ± 13.6 min for RPSF ( < 0.001). The infection rate was less frequent in the PCSF group (3% for PCSF versus 14.3% for RPSF, = 0.01). One clinical trial reported better functional recovery after PCSF. In all biomechanical studies, the threshold for implant failure was beyond the applied forces corresponding to daily activities.
CONCLUSIONS
PCSF for traumatic SPD is associated with less operative time, less blood loss, and a lower infection rate when compared to conventional plate techniques without increasing the incidence of postoperative fixation failure and revision surgery. Moreover, PCSF has been proven to be biomechanically sufficient for stabilization. Therefore, it should be considered an efficient and viable alternative for the reconstruction of SPD when closed reduction can be adequately achieved.
PubMed: 37568389
DOI: 10.3390/jcm12154988 -
European Journal of Trauma and... Dec 2023The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring....
BACKGROUND/PURPOSE
The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring. Currently, open reduction and internal fixation (ORIF) by means of plating represents the gold standard treatment. Advances in percutaneous fixation techniques have shown improvements in blood loss, surgery time, and scar length. Therefore, this approach should also be adopted for treatment of symphyseal injuries. The technique could be important since failure rates, following ORIF at the symphysis, remain unacceptably high. The aim of this biomechanical study was to assess a semi-rigid fixation technique for treatment of such anterior pelvic ring injuries versus current gold standards of plate osteosynthesis.
METHODS
An anterior pelvic ring injury type III APC according to the Young and Burgess classification was simulated in eighteen composite pelvises, assigned to three groups (n = 6) for fixation with either a single plate, two orthogonally positioned plates, or the semi-rigid technique using an endobutton suture implant. Biomechanical testing was performed in a simulated upright standing position under progressively increasing cyclic loading at 2 Hz until failure or over 150,000 cycles. Relative movements between the bone segments were captured by motion tracking.
RESULTS
Initial quasi-static and dynamic stiffness, as well as dynamic stiffness after 100,000 cycles, was not significantly different among the fixation techniques (p ≥ 0.054).). The outcome measures for total displacement after 20,000, 40,000, 60,000, 80,000, and 100,000 cycles were associated with significantly higher values for the suture technique versus double plating (p = 0.025), without further significant differences among the techniques (p ≥ 0.349). Number of cycles to failure and load at failure were highest for double plating (150,000 ± 0/100.0 ± 0.0 N), followed by single plating (132,282 ± 20,465/91.1 ± 10.2 N), and the suture technique (116,088 ± 12,169/83.0 ± 6.1 N), with significantly lower values in the latter compared to the former (p = 0.002) and no further significant differences among the techniques (p ≥ 0.329).
CONCLUSION
From a biomechanical perspective, the semi-rigid technique for fixation of unstable pubic symphysis injuries demonstrated promising results with moderate to inferior behaviour compared to standard plating techniques regarding stiffness, cycles to failure and load at failure. This knowledge could lay the foundation for realization of further studies with larger sample sizes, focusing on the stabilization of the anterior pelvic ring.
Topics: Humans; Pubic Symphysis; Biomechanical Phenomena; Fracture Fixation, Internal; Fractures, Bone; Pelvis; Bone Plates
PubMed: 37555991
DOI: 10.1007/s00068-023-02333-6 -
Frontiers in Surgery 2023Stress urinary incontinence (SUI) that has been associated with abnormal pelvic floor muscle function or morphology is a common condition. This research aimed to study...
BACKGROUND
Stress urinary incontinence (SUI) that has been associated with abnormal pelvic floor muscle function or morphology is a common condition. This research aimed to study the impact of the four-dimensional (4D) pelvic floor ultrasound on the treatment of female patients with clinical diagnosis of SUI and to evaluate its clinical significance on SUI.
METHODS
We enrolled 51 women with SUI. Before transobturator suburethral tape procedures, the patients underwent 4D pelvic floor ultrasonography. The measurements include residual urine volume, bladder detrusor thickness in resting state, the vertical distance from the bladder neck to the posterior inferior edge of pubic symphysis at rest and Valsalva movement, posterior angle of bladder urethra, and urethral rotation angle. The degree of movement of the bladder neck (the difference between the vertical distance from the bladder neck to the posterior inferior edge of the pubic symphysis under the resting state and the maximum Valsalva movement) and the formation of a funnel at the internal orifice of the urethra were calculated.
RESULTS
The mean bladder detrusor thickness was 2.6 ± 0.9 mm, the vertical distance from the bladder neck to the posterior inferior edge of pubic symphysis was 27.7 ± 4.5 mm, the posterior angle of the bladder was 122.7 ± 18.9°, the vertical distance from the rectal ampulla to the posterior inferior edge of pubic symphysis was 18.5 ± 4.6 mm, and the mean area of hiatus of the levator ani muscle was 22.1 ± 6.0 cm. The mean posterior angle of the bladder on Valsalva was 159.3 ± 23.1°, and the mean urethral rotation angle was 67.2 ± 21.4°.
CONCLUSIONS
The 4D pelvic floor ultrasound is a reliable method in evaluating preoperational morphological characteristics of patients with SUI. With the help of the 4D pelvic floor ultrasound, the individualized treatment regimen can be developed and, more importantly, the inappropriate surgical decision can be avoided.
PubMed: 37545841
DOI: 10.3389/fsurg.2023.1126293