Medicine Mar 2021The aim of this meta-analysis with trial sequential analysis (TSA) was to evaluate the effect of a polyurethane (PU) tracheal tube cuff on the prevention of... (Meta-Analysis)
Meta-Analysis
Comparison of polyurethane tracheal tube cuffs and conventional polyvinyl chloride tube cuff for prevention of ventilator-associated pneumonia: A systematic review with meta-analysis.
BACKGROUND
The aim of this meta-analysis with trial sequential analysis (TSA) was to evaluate the effect of a polyurethane (PU) tracheal tube cuff on the prevention of ventilator-associated pneumonia (VAP).
METHODS
We performed a systematic search using the MEDLINE database through PubMed, Cochrane Central Register of Controlled Trial, SCOPUS, and Web of Science.Randomized controlled trials comparing the incidence of VAP and clinically relevant outcomes between PU cuff tubes and polyvinyl chloride (PVC) cuff tubes in adult patients. Two authors independently extracted study details, patient characteristics, and clinical outcomes such as incidence of VAP, bacterial colonization of tracheal aspirate, duration of mechanical ventilation, ICU stay, and ICU mortality.
RESULTS
From 309 studies identified as potentially eligible, six studies with 1226 patients were included in this meta-analysis. All studies compared the incidence of VAP between PU cuffs and PVC cuffs. Use of a PU cuff was not associated with a reduction in VAP incidence (RR = 0.68; 95% CI, 0.45-1.03) with significant statistical heterogeneity (I2 = 65%). The quality of evidence was "very low." According to the TSA, the actual sample size was only 15.8% of the target sample size, and the cumulative Z score did not cross the trial sequential monitoring boundary for benefit. No positive impact was reported for the other relevant outcomes for PU cuffs.
CONCLUSIONS
The use of a PU cuff for mechanical ventilation did not prevent VAP. Further trials with a low risk of bias need to be performed.
Topics: Equipment Design; Humans; Intensive Care Units; Intubation, Intratracheal; Pneumonia, Ventilator-Associated; Polyurethanes; Polyvinyl Chloride; Respiration, Artificial
PubMed: 33655952
DOI: 10.1097/MD.0000000000024906 -
The Cochrane Database of Systematic... Feb 2021Extracranial carotid artery stenosis is the major cause of stroke, which can lead to disability and mortality. Carotid endarterectomy (CEA) with carotid patch... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Extracranial carotid artery stenosis is the major cause of stroke, which can lead to disability and mortality. Carotid endarterectomy (CEA) with carotid patch angioplasty is the most popular technique for reducing the risk of stroke. Patch material may be made from an autologous vein, bovine pericardium, or synthetic material including polytetrafluoroethylene (PTFE), Dacron, polyurethane, and polyester. This is an update of a review that was first published in 1996 and was last updated in 2010.
OBJECTIVES
To assess the safety and efficacy of different types of patch materials used in carotid patch angioplasty. The primary hypothesis was that a synthetic material was associated with lower risk of patch rupture versus venous patches, but that venous patches were associated with lower risk of perioperative stroke and early or late infection, or both.
SEARCH METHODS
We searched the Cochrane Stroke Group trials register (last searched 25 May 2020); the Cochrane Central Register of Controlled Trials (CENTRAL; 2020, Issue 4), in the Cochrane Library; MEDLINE (1966 to 25 May 2020); Embase (1980 to 25 May 2020); the Index to Scientific and Technical Proceedings (1980 to 2019); the Web of Science Core Collection; ClinicalTrials.gov; and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) portal. We handsearched relevant journals and conference proceedings, checked reference lists, and contacted experts in the field.
SELECTION CRITERIA
Randomised and quasi-randomised trials (RCTs) comparing one type of carotid patch with another for CEA.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed eligibility, risk of bias, and trial quality; extracted data; and determined the quality of evidence using the GRADE approach. Outcomes, for example, perioperative ipsilateral stroke and long-term ipsilateral stroke (at least one year), were collected and analysed.
MAIN RESULTS
We included 14 trials involving a total of 2278 CEAs with patch closure operations: seven trials compared vein closure with PTFE closure, five compared Dacron grafts with other synthetic materials, and two compared bovine pericardium with other synthetic materials. In most trials, a patient could be randomised twice and could have each carotid artery randomised to different treatment groups. Synthetic patch compared with vein patch angioplasty Vein patch may have little to no difference in effect on perioperative ipsilateral stroke between synthetic versus vein materials, but the evidence is very uncertain (odds ratio (OR) 2.05, 95% confidence interval (CI) 0.66 to 6.38; 5 studies, 797 participants; very low-quality evidence). Vein patch may have little to no difference in effect on long-term ipsilateral stroke between synthetic versus vein materials, but the evidence is very uncertain (OR 1.45, 95% CI 0.69 to 3.07; P = 0.33; 4 studies, 776 participants; very low-quality evidence). Vein patch may increase pseudoaneurysm formation when compared with synthetic patch, but the evidence is very uncertain (OR 0.09, 95% CI 0.02 to 0.49; 4 studies, 776 participants; very low-quality evidence). However, the numbers involved were small. Dacron patch compared with other synthetic patch angioplasty Dacron versus PTFE patch materials PTFE patch may reduce the risk of perioperative ipsilateral stroke (OR 3.35, 95% CI 0.19 to 59.06; 2 studies, 400 participants; very low-quality evidence). PTFE patch may reduce the risk of long-term ipsilateral stroke (OR 1.52, 95% CI 0.25 to 9.27; 1 study, 200 participants; very low-quality evidence). Dacron may result in an increase in perioperative combined stroke and transient ischaemic attack (TIA) (OR 4.41 95% CI 1.20 to 16.14; 1 study, 200 participants; low-quality evidence) when compared with PTFE. Early arterial re-stenosis or occlusion (within 30 days) was also higher for Dacron patches. During follow-up for longer than one year, more 'any strokes' (OR 10.58, 95% CI 1.34 to 83.43; 2 studies, 304 participants; low-quality evidence) and stroke/death (OR 6.06, 95% CI 1.31 to 28.07; 1 study, 200 participants; low-quality evidence) were reported with Dacron patch closure, although numbers of outcome events were small. Dacron patch may increase the risk of re-stenosis when compared with other synthetic materials (especially with PTFE), but the evidence is very uncertain (OR 3.73, 95% CI 0.71 to 19.65; 3 studies, 490 participants; low-quality evidence). Bovine pericardium patch compared with other synthetic patch angioplasty Bovine pericardium versus PTFE patch materials Evidence suggests that bovine pericardium patch results in a reduction in long-term ipsilateral stroke (OR 4.17, 95% CI 0.46 to 38.02; 1 study, 195 participants; low-quality evidence). Bovine pericardial patch may reduce the risk of perioperative fatal stroke, death, and infection compared to synthetic material (OR 5.16, 95% CI 0.24 to 108.83; 2 studies, 290 participants; low-quality evidence for PTFE, and low-quality evidence for Dacron; OR 4.39, 95% CI 0.48 to 39.95; 2 studies, 290 participants; low-quality evidence for PTFE, and low-quality evidence for Dacron; OR 7.30, 95% CI 0.37 to 143.16; 1 study, 195 participants; low-quality evidence, respectively), but the numbers of outcomes were small. The evidence is very uncertain about effects of the patch on infection outcomes.
AUTHORS' CONCLUSIONS
The number of outcome events is too small to allow conclusions, and more trial data are required to establish whether any differences do exist. Nevertheless, there is little to no difference in effect on perioperative and long-term ipsilateral stroke between vein and any synthetic patch material. Some evidence indicates that other synthetic patches (e.g. PTFE) may be superior to Dacron grafts in terms of perioperative stroke and TIA rates, and both early and late arterial re-stenosis and occlusion. Pseudoaneurysm formation may be more common after use of a vein patch than after use of a synthetic patch. Bovine pericardial patch, which is an acellular xenograft material, may reduce the risk of perioperative fatal stroke, death, and infection compared to other synthetic patches. Further large RCTs are required before definitive conclusions can be reached.
Topics: Aneurysm, False; Angioplasty; Bias; Bioprosthesis; Blood Vessel Prosthesis; Carotid Stenosis; Endarterectomy, Carotid; Humans; Polyethylene Terephthalates; Polytetrafluoroethylene; Postoperative Complications; Randomized Controlled Trials as Topic; Saphenous Vein; Stroke
PubMed: 33598915
DOI: 10.1002/14651858.CD000071.pub4 -
Neonatal Network : NN Nov 2020The purpose of this article was to determine specific skin injury prevention interventions for neonates in the NICU.
PURPOSE
The purpose of this article was to determine specific skin injury prevention interventions for neonates in the NICU.
DESIGN
The design was a systematic review.
SAMPLE
PubMed, Cumulative Index of Nursing and Allied Health Literature (CINAHL), Embase, and Scopus were systematically searched to identify quantitative studies identifying skin injury preventions for neonates in the NICU.
OUTCOMES
The outcomes included skin integrity or skin condition.
RESULTS
Nineteen studies were included in the review. Twelve studies included a randomized design. Barriers were the main interventions for the prevention of pressure injury, medical adhesive skin injury, diaper dermatitis, and general skin condition. The types of barriers included hydrocolloids, polyurethane-based dressings, film-forming skin protectant, or emollients. Nonbarrier interventions included rotation between a mask and nasal continuous positive airway pressure (NCPAP) interfaces, utilization of prescribed guidelines to decrease pressure injuries, and use of a lower concentration of chlorhexidine gluconate as a disinfectant.
Topics: Bandages; Continuous Positive Airway Pressure; Humans; Infant, Newborn; Intensive Care Units, Neonatal; Skin; Skin Diseases
PubMed: 33318228
DOI: 10.1891/0730-0832/11-T-623 -
Systematic Review of Thumb Carpometacarpal Joint Hemiresection Interposition Arthroplasty Materials.Hand (New York, N.Y.) Sep 2022Osteoarthritis of the first carpometacarpal joint is a common condition. Various management options and surgical procedures have been described to treat symptomatic...
BACKGROUND
Osteoarthritis of the first carpometacarpal joint is a common condition. Various management options and surgical procedures have been described to treat symptomatic cases. Many systematic reviews examine aspects of thumb carpometacarpal joint osteoarthritis treatment, although none solely examines the outcomes of trapezial partial resection and interposition arthroplasty in stage II to III patients in detail, yet this technique is of growing interest as surgeons seek more nuanced, tailored approaches for osteoarthritis of the first carpometacarpal joint.
METHODS
A systematic review of the thumb carpometacarpal joint hemiresection and interposition arthroplasty was performed with pain assessment as a primary outcome measure and patient-reported outcome measures (PROMs) and reoperation rate as secondary outcome measures. A search was performed between 2004 and 2019 using MEDLINE, Embase, and PubMed. Preferred Reporting Items and Systematic Reviews and Meta-Analyses guidelines were used.
RESULTS
Twenty-nine articles met the inclusion criteria and were included in the final review. Pain relief and improved PROMs were described in all the articles using this technique with all the interposition materials. Materials such as polyurethane urea matrix and poly-l/d-lactide scaffold had higher complication rates. Revision rates varied and were highest with the polyurethane urea matrix.
CONCLUSIONS
This review shows that hemiresection interposition arthroplasty is a useful technique and provides symptomatic benefit in patients with Eaton-Littler stage II and III osteoarthritis. Revision surgery rates due to persistent pain and instability were higher with the use of implants. Larger and long-term studies of this technique using autologous or more bioinert materials and implants are required to assess duration of symptomatic benefit.
Topics: Arthroplasty; Carpometacarpal Joints; Humans; Osteoarthritis; Pain; Polyurethanes; Thumb; Urea
PubMed: 33307813
DOI: 10.1177/1558944720974124 -
The Journal of Trauma and Acute Care... Apr 2021Burns cause a huge economic burden to society, and the wounds can be very difficult to manage. Clinical experience suggests that amniotic membrane (AM) is an economical... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Burns cause a huge economic burden to society, and the wounds can be very difficult to manage. Clinical experience suggests that amniotic membrane (AM) is an economical and effective biological dressing for burns. However, few systematic reviews or meta-analyses have been published on such use. We aimed to evaluate the role of AM dressings in burn wounds.
METHODS
A systematic search of the PubMed, Cochrane, Embase, and Web of Science databases was conducted in March 2020. The search was conducted to identify randomized control trials that compared selected features of AM with those of other dressings, such as silver sulfadiazine, polyurethane membrane, and honey. For skin-grafted wounds, we compared AM-covered skin grafts and traditional staple-fixed skin grafts. Outcomes of interest for the efficacy analysis included wound infection, pain, itching, scarring, and healing time. The number of adverse events in each treatment group, the rate of withdrawal because of adverse effects, the cost of treatment, and patient acceptability were assessed for the feasibility analysis.
RESULTS
Eleven randomized controlled trials with 816 participants total were identified in our review. Amniotic membrane treatment was more effective than conventional methods, silver sulfadiazine, and polyurethane membrane in treating burn wounds, but AM appears to be less effective than honey. No reports of AM-related disease transmission or adverse reactions were described in the included articles.
CONCLUSION
Amniotic membrane has beneficial effects in treating burn wounds; however, the evidence needs to be strengthened by further robust randomized controlled trials.
LEVEL OF EVIDENCE
Systematic Review/Meta-analysis, level III.
Topics: Amnion; Biological Dressings; Burns; Humans
PubMed: 33284236
DOI: 10.1097/TA.0000000000003050 -
European Journal of Vascular and... Feb 2021There is discordance between reviews comparing eversion endarterectomy (EvE) with conventional carotid endarterectomy (CEA) mostly because under this term various... (Comparative Study)
Comparative Study Meta-Analysis
OBJECTIVE
There is discordance between reviews comparing eversion endarterectomy (EvE) with conventional carotid endarterectomy (CEA) mostly because under this term various "closure" techniques are included, from direct closure to a wide spectrum of patches with different materials.
DATA SOURCES
MEDLINE (via PubMed) and SCOPUS.
REVIEW METHODS
This was a systematic review of the Medline (via PubMed) and SCOPUS databases for randomised controlled trials (RCTs) comparing different CEA closure techniques. Network meta-analysis (NMA) was performed with a frequentist approach. The primary and the secondary outcome measures were the 30 day combined stroke and death rate and the late restenosis rate, respectively.
RESULTS
Twenty-three RCTs were finally included in the NMA with a total of 4440 patients randomised, representing seven different techniques (primary carotid closure, n = 753; EvE, n = 431; vein patch closure, n = 973; polytetrafluoroethylene [PTFE] patch, n = 948; Dacron patch, n = 828; bovine pericardium patch, n = 249; and polyurethane patch, n = 258). NMA showed that EvE had a decreased 30 day combined stroke and death rate vs. all other methods of arterial closure, with the exception of PTFE and bovine pericardium patching. Additionally, EvE was associated with the lowest restenosis rate vs. all other methods of arterial closure after CEA. EvE was significantly superior to Dacron patches with regard to late restenosis, with the prediction intervals (PIs) lying completely on the beneficial side (risk ratio 0.06; PI 0.01-0.58) and increasing confidence of this comparison. Rare catastrophic complications of vein patch blow out or synthetic patch infection were reported in 0.2% of the total (n = 9/4 400) and no comparisons were made.
CONCLUSION
EvE and patching with bovine pericardium or PTFE is associated with a lower incidence in both short term and late undesired outcomes following CEA and seems to represent the best choice compared with other carotid closure techniques. These results may support the vascular surgeon's choice of technique/patch material.
Topics: Biocompatible Materials; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Carotid Arteries; Endarterectomy, Carotid; Humans; Outcome Assessment, Health Care; Postoperative Complications; Wound Closure Techniques
PubMed: 33257115
DOI: 10.1016/j.ejvs.2020.10.009 -
Dimensions of Critical Care Nursing :... 2020Hemodynamic monitoring, implemented by the placement of peripheral arterial catheters (PACs), is a characterizing aspect of the intensive care units. Peripheral arterial...
BACKGROUND
Hemodynamic monitoring, implemented by the placement of peripheral arterial catheters (PACs), is a characterizing aspect of the intensive care units. Peripheral arterial catheters can continually detect blood pressure and quickly conduct blood sampling. The use of PACs is generally considered safe, without serious complications. Currently, only 25% of the implanted catheters are actually subject to complications, including accidental removal, dislocation, occlusion, and infection. All of these complications arise from inadequate catheter stabilization at the level of the skin. This study aimed to summarize and describe the effectiveness and characteristics of dressings and securement devices for catheter stabilization.
METHODS
A systematic review of literature from the following databases was conducted: MEDLINE, CINAHL, Cochrane, EMBASE, and OvidSP. We used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement to guide article selection and reporting.
RESULTS
Herein 626 articles were referred, with 5 directly related to the topic under discussion. We found 3 studies that describe PAC failure and 4 about dislodgement. We described 6 types of dressings or securement devices and classified them into 3 categories for classifying PAC dressings or securement devices. These were detected and grouped as adhesive tissues, sutureless devices, and transparent polyurethane dressings.
CONCLUSIONS
Current research indicates that transparent polyurethane dressings offer the most effective catheter stabilization, but adhesive tissues may constitute a valid alternative. However, there are limited high-quality studies about effective dressings and securement devices for PACs.
Topics: Bandages; Catheterization, Peripheral; Catheters, Indwelling; Humans; Intensive Care Units; Polyurethanes
PubMed: 32740194
DOI: 10.1097/DCC.0000000000000433 -
Materials (Basel, Switzerland) Jul 2020We conducted a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to ascertain why... (Review)
Review
We conducted a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to ascertain why polyurethanes (PUs) have been used in the manufacture and design of cardiovascular devices. A complete database search was performed with PubMed, Scopus, and Web of Science as the information sources. The search period ranged from 1 January 2005 to 31 December 2019. We recovered 1552 articles in the first stage. After the duplicate selection and extraction procedures, a total of 21 papers were included in the analysis. We concluded that polyurethanes are being applied in medical devices because they have the capability to tolerate contractile forces that originate during the cardiac cycle without undergoing plastic deformation or failure, and the capability to imitate the behaviors of different tissues. Studies have reported that polyurethanes cause severe problems when applied in blood-contacting devices that are implanted for long periods. However, the chemical compositions and surface characteristics of polyurethanes can be modified to improve their mechanical properties, blood compatibility, and endothelial cell adhesion, and to reduce their protein adhesion. These modifications enable the use of polyurethanes in the manufacture and design of cardiovascular devices.
PubMed: 32707852
DOI: 10.3390/ma13153250 -
Journal of Foot and Ankle Research Jun 2020The effect of different orthotic materials on plantar pressures has not been systematically investigated. This study aimed to review and summarise the findings from...
BACKGROUND
The effect of different orthotic materials on plantar pressures has not been systematically investigated. This study aimed to review and summarise the findings from studies that have evaluated the effect of orthotic materials on plantar pressures.
METHODS
We conducted a systematic review of experimental studies that evaluated the effect of foot orthotic materials or shoe insole materials on plantar pressures using in-shoe testing during walking. The following databases were searched: MEDLINE, CINAHL, Embase and SPORTDiscus. Included studies were assessed for methodological quality using a modified Quality Index. Peak pressure, pressure-time integral, maximum force, force-time integral, contact area, and contact time were variables of interest. Data were synthesised descriptively as studies were not sufficiently homogeneous to conduct meta-analysis. Standardised mean differences (Cohen's d) were calculated to provide the size of the effect between materials found in each study.
RESULTS
Five studies were identified as meeting the eligibility criteria. All five studies were laboratory-based and used a repeated measures design. The quality of the studies varied with scores ranging between 20 and 23 on the modified Quality Index (maximum index score 28). The included studies investigated the effects of polyurethane (including PORON®), polyethylene (including Plastazote®), ethyl vinyl acetate (EVA) and carbon graphite on plantar pressures. Polyurethane (including PORON®), polyethylene (including Plastazote®) and EVA were all found to reduce peak pressure.
CONCLUSION
Based on the limited evidence supplied from the five studies included in this review, some orthotic materials can reduce plantar pressures during walking. Polyurethane (including PORON®), polyethylene (including Plastazote®) and EVA reduce peak pressure beneath varying regions of the foot. Future well-designed studies will strengthen this evidence.
Topics: Adult; Aged; Biomechanical Phenomena; Equipment Design; Female; Foot; Foot Orthoses; Humans; Male; Middle Aged; Plantar Plate; Pressure; Walking; Weight-Bearing
PubMed: 32527296
DOI: 10.1186/s13047-020-00401-3 -
Annals of Work Exposures and Health Jul 2020Diisocyanates are a group of chemicals that are widely used in occupational settings. They are known to induce various health effects, including skin- and respiratory...
Diisocyanates are a group of chemicals that are widely used in occupational settings. They are known to induce various health effects, including skin- and respiratory tract sensitization resulting in allergic dermatitis and asthma. Exposure to diisocyanates has been studied in the past decades by using different types of biomonitoring markers and matrices. The aim of this review as part of the HBM4EU project was to assess: (i) which biomarkers and matrices have been used for biomonitoring diisocyanates and what are their strengths and limitations; (ii) what are (current) biomonitoring levels of the major diisocyanates (and metabolites) in workers; and (iii) to characterize potential research gaps. For this purpose we conducted a systematic literature search for the time period 2000-end 2018, thereby focussing on three types of diisocyanates which account for the vast majority of the total isocyanate market volume: hexamethylene diisocyanate (HDI), toluene diisocyanate (TDI), and 4,4'-methylenediphenyl diisocyanate (MDI). A total of 28 publications were identified which fulfilled the review inclusion criteria. The majority of these studies (93%) investigated the corresponding diamines in either urine or plasma, but adducts have also been investigated by several research groups. Studies on HDI were mostly in the motor vehicle repair industry [with urinary hexamethylene diamine result ranging from 0.03 to 146.5 µmol mol-1 creatinine]. For TDI, there is mostly data on foam production [results for urinary toluene diamine ranging from ~0.01 to 97 µmol mol-1 creatinine] whereas the available MDI data are mainly from the polyurethane industry (results for methylenediphenyl diamine range from 0.01 to 32.7 µmol mol-1 creatinine). About half of the studies published were prior to 2010 hence might not reflect current workplace exposure. There is large variability within and between studies and across sectors which could be potentially explained by several factors including worker or workplace variability, short half-lives of biomarkers, and differences in sampling strategies and analytical techniques. We identified several research gaps which could further be taken into account when studying diisocyanates biomonitoring levels: (i) the development of specific biomarkers is promising (e.g. to study oligomers of HDI which have been largely neglected to date) but needs more research before they can be widely applied, (ii) since analytical methods differ between studies a more uniform approach would make comparisons between studies easier, and (iii) dermal absorption seems a possible exposure route and needs to be further investigated. The use of MDI, TDI, and HDI has been recently proposed to be restricted in the European Union unless specific conditions for workers' training and risk management measures apply. This review has highlighted the need for a harmonized approach to establishing a baseline against which the success of the restriction can be evaluated.
Topics: Biological Monitoring; Humans; Occupational Exposure; Polyurethanes; Toluene 2,4-Diisocyanate; Workplace
PubMed: 32313948
DOI: 10.1093/annweh/wxaa038