-
Infectious Disease Reports Mar 2024Despite the expanding use of orthopedic devices and the application of strict pre- and postoperative protocols, the elimination of postoperative implant-related... (Review)
Review
Current Progress and Future Perspectives in Contact and Releasing-Type Antimicrobial Coatings of Orthopaedic Implants: A Systematic Review Analysis Emanated from In Vitro and In Vivo Models.
Despite the expanding use of orthopedic devices and the application of strict pre- and postoperative protocols, the elimination of postoperative implant-related infections remains a challenge. To identify and assess the in vitro and in vivo properties of antimicrobial-, silver- and iodine-based implants, as well as to present novel approaches to surface modifications of orthopedic implants. A systematic computer-based review on the development of these implants, on PubMed and Web of Science databases, was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Overall, 31 in vitro and 40 in vivo entries were evaluated. Regarding the in vitro studies, antimicrobial-based coatings were assessed in 12 entries, silver-based coatings in 10, iodine-based in 1, and novel-applied coating technologies in 8 entries. Regarding the in vivo studies, antimicrobial coatings were evaluated in 23 entries, silver-coated implants in 12, and iodine-coated in 1 entry, respectively. The application of novel coatings was studied in the rest of the cases (4). Antimicrobial efficacy was examined using different bacterial strains, and osseointegration ability and biocompatibility were examined in eukaryotic cells and different animal models, including rats, rabbits, and sheep. Assessment of both in vivo and in vitro studies revealed a wide antimicrobial spectrum of the coated implants, related to reduced bacterial growth, inhibition of biofilm formation, and unaffected or enhanced osseointegration, emphasizing the importance of the application of surface modification techniques as an alternative for the treatment of orthopedic implant infections in the clinical settings.
PubMed: 38667751
DOI: 10.3390/idr16020025 -
Frontiers in Rehabilitation Sciences 2024Bone-anchored prostheses (BAP) are an advanced reconstructive surgical approach for individuals who had transfemoral amputation and are unable to use the conventional...
INTRODUCTION
Bone-anchored prostheses (BAP) are an advanced reconstructive surgical approach for individuals who had transfemoral amputation and are unable to use the conventional socket-suspension systems for their prostheses. Access to this technology has been limited in part due to the lag between the start of a new procedure and the availability of evidence that is required before making decisions about widespread provision. This systematic review presents as a single resource up-to-date information on aspects most relevant to decision makers, i.e., clinical efficacy, safety parameters, patient experiences, and health economic outcomes of this technology.
METHODS
A systematic search of the literature was conducted by an information specialist in PubMed, MEDLINE, Embase, CINAHL, Cochrane Library, the Core Collection of Web of Science, CADTH's Grey Matters, and Google Scholar up until May 31, 2023. Peer-reviewed original research articles on the outcomes of clinical effectiveness (health-related quality of life, mobility, and prosthesis usage), complications and adverse events, patient experiences, and health economic outcomes were included. The quality of the studies was assessed using the Oxford Centre for Evidence-Based Medicine Levels of Evidence and ROBINS-I, as appropriate.
RESULTS
Fifty studies met the inclusion criteria, of which 12 were excluded. Thirty-eight studies were finally included in this review, of which 21 reported on clinical outcomes and complications, 9 case series and 1 cohort study focused specifically on complications and adverse events, and 2 and 5 qualitative studies reported on patient experience and health economic assessments, respectively. The most common study design is a single-arm trial (pre-/post-intervention design) with varying lengths of follow-up.
DISCUSSION
The clinical efficacy of this technology is evident in selected populations. Overall, patients reported increased health-related quality of life, mobility, and prosthesis usage post-intervention. The most common complication is a superficial or soft-tissue infection, and more serious complications are rare. Patient-reported experiences have generally been positive. Evidence indicates that bone-anchored implants for prosthesis fixation are cost-effective for those individuals who face significant challenges in using socket-suspension systems, although they may offer no additional advantage to those who are functioning well with their socket-suspended prostheses.
PubMed: 38628292
DOI: 10.3389/fresc.2024.1336042 -
Journal of Clinical Medicine Apr 2024This systematic review aimed to evaluate the impact of antiresorptive drug therapy on osseointegrated dental implants and the association with medication-related... (Review)
Review
This systematic review aimed to evaluate the impact of antiresorptive drug therapy on osseointegrated dental implants and the association with medication-related osteonecrosis of the jaw (MRONJ). A systematic search, including a computer search of several databases with specific keywords, a reference search, and a manual search of four key maxillofacial journals were performed. Relevant articles were then evaluated and those that fulfilled the five predetermined criteria were chosen to enter the final review. A total of 445 implants in 135 subjects were included in the eight studies analyzed in the final review. The failure rate of dental implants after antiresorptive medication in the included studies was 23%, with 83% of failures attributed to MRONJ. The average time from antiresorptive drug initiation to MRONJ development was approximately 34 months, ranging from 3 months to 16 years. The majority of MRONJ cases were classified as stage 2, and all sites showed either complete healing or substantial mucosal coverage after treatment. This review highlights the significant impact of antiresorptive drugs on osseo- integrated implants, with MRONJ identified as a leading cause of implant failure. The potential role of peri-implantitis as a trigger for MRONJ is emphasized. Regular monitoring and maintaining good periodontal health, especially within the first three years of antiresorptive drug therapy initiation, are crucial for implant success. Physicians and dentists should provide comprehensive information to patients prescribed with antiresorptive drugs, emphasizing the need for an awareness of the risks of MRONJ in the context of osseointegrated implants. A longer term of follow-up is recommended to identify and manage MRONJ around dental implants in an early manner.
PubMed: 38610856
DOI: 10.3390/jcm13072091 -
The Saudi Dental Journal Mar 2024This review aimed to comprehensively investigate the impact of Hormone Replacement Therapy (HRT) on implant osseointegration and bone loss. The study considered factors... (Review)
Review
BACKGROUND
This review aimed to comprehensively investigate the impact of Hormone Replacement Therapy (HRT) on implant osseointegration and bone loss. The study considered factors such as HRT type, osteoporosis, smoking, and diabetes mellitus, and analysed the available literature to provide insights into the association between HRT and implant outcomes.
METHODS
Multiple databases were utilized, and studies with diverse designs and methodologies were included that examined the relationship between HRT and implant osseointegration. The selected studies were analyzed and relevant data on implant success rates, bone loss, and other correlations was extracted.
RESULTS
The review findings indicate that HRT has a detrimental impact on implant osseointegration, as evidenced by lower implant success rates and increased bone loss in HRT-treated individuals. The odds ratio analysis further strengthens this association, with significant values of 0.59 (95% CI: 0.50-0.70) and 0.64 (95% CI: 0.54-0.76), indicating a higher likelihood of implant failure in HRT-treated patients., highlighting the need for caution when considering HRT as a treatment option in patients undergoing implant procedures. Smoking and diabetes mellitus were also found to significantly affect implant outcomes, emphasizing the importance of addressing these factors in patient management.
CONCLUSION
The assessments demonstrate that HRT adversely affects implant osseointegration and increases bone loss. The results suggest the importance of considering the potential negative impact of HRT on implant outcomes and the need for thorough patient evaluation and management. Further research is warranted to explore the underlying mechanisms, assess the impact of specific HRT types and dosages, and evaluate preventive strategies to mitigate the detrimental effects of HRT on implant success.
PubMed: 38525181
DOI: 10.1016/j.sdentj.2023.10.021 -
International Journal of Implant... Mar 2024To comprehensively assess the existing literature regarding the rapidly evolving in vivo application of magnetic resonance imaging (MRI) for potential applications,... (Review)
Review
PURPOSE
To comprehensively assess the existing literature regarding the rapidly evolving in vivo application of magnetic resonance imaging (MRI) for potential applications, benefits, and challenges in dental implant surgery.
METHODS
Electronic and manual searches were conducted in PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases by two reviewers following the PICOS search strategy. This involved using medical subject headings (MeSH) terms, keywords, and their combinations.
RESULTS
Sixteen studies were included in this systematic review. Of the 16, nine studies focused on preoperative planning and follow-up phases, four evaluated image-guided implant surgery, while three examined artifact reduction techniques. The current literature highlights several MRI protocols that have recently investigated and evaluated the in vivo feasibility and accuracy, focusing on its potential to provide surgically relevant quantitative and qualitative parameters in the assessment of osseointegration, peri-implant soft tissues, surrounding anatomical structures, reduction of artifacts caused by dental implants, and geometric accuracy relevant to implant placement. Black Bone and MSVAT-SPACE MRI, acquired within a short time, demonstrate improved hard and soft tissue resolution and offer high sensitivity in detecting pathological changes, making them a valuable alternative in targeted cases where CBCT is insufficient. Given the data heterogeneity, a meta-analysis was not possible.
CONCLUSIONS
The results of this systematic review highlight the potential of dental MRI, within its indications and limitations, to provide perioperative surgically relevant parameters for accurate placement of dental implants.
Topics: Dental Implants; Dental Implantation, Endosseous; Osseointegration; Magnetic Resonance Imaging; Surgery, Computer-Assisted
PubMed: 38507139
DOI: 10.1186/s40729-024-00532-3 -
Journal of Orthopaedic Translation Mar 2024Fracture-related infection (FRI) remains a major concern in orthopaedic trauma. Functionalizing implants with antibacterial coatings are a promising strategy in... (Review)
Review
OBJECTIVE
Fracture-related infection (FRI) remains a major concern in orthopaedic trauma. Functionalizing implants with antibacterial coatings are a promising strategy in mitigating FRI. Numerous implant coatings have been reported but the preventive and therapeutic effects vary. This systematic review aimed to provide a comprehensive overview of current implant coating strategies to prevent and treat FRI in animal fracture and bone defect models.
METHODS
A literature search was performed in three databases: PubMed, Web of Science and Embase, with predetermined keywords and criteria up to 28 February 2023. Preclinical studies on implant coatings in animal fracture or defect models that assessed antibacterial and bone healing effects were included.
RESULTS
A total of 14 studies were included in this systematic review, seven of which used fracture models and seven used defect models. Passive coatings with bacteria adhesion resistance were investigated in two studies. Active coatings with bactericidal effects were investigated in 12 studies, four of which used metal ions including Ag and Cu; five studies used antibiotics including chlorhexidine, tigecycline, vancomycin, and gentamicin sulfate; and the other three studies used natural antibacterial materials including chitosan, antimicrobial peptides, and lysostaphin. Overall, these implant coatings exhibited promising efficacy in antibacterial effects and bone formation.
CONCLUSION
Antibacterial coating strategies reduced bacterial infections in animal models and favored bone healing . Future studies of implant coatings should focus on optimal biocompatibility, antibacterial effects against multi-drug resistant bacteria and polymicrobial infections, and osseointegration and osteogenesis promotion especially in osteoporotic bone by constructing multi-functional coatings for FRI therapy.
THE TRANSLATIONAL POTENTIAL OF THIS PAPER
The clinical treatment of FRI is complex and challenging. This review summarizes novel orthopaedic implant coating strategies applied to FRI in preclinical studies, and offers a perspective on the future development of orthopaedic implant coatings, which can potentially contribute to alternative strategies in clinical practice.
PubMed: 38495742
DOI: 10.1016/j.jot.2023.12.006 -
Journal of Functional Biomaterials Feb 2024This study aims to evaluate the influence of a nanohydroxyapatite layer applied to the surface of titanium or titanium alloy implants on the intricate process of... (Review)
Review
This study aims to evaluate the influence of a nanohydroxyapatite layer applied to the surface of titanium or titanium alloy implants on the intricate process of osseointegration and its effect on osteoblast cell lines, compared to uncoated implants. Additionally, the investigation scrutinizes various modifications of the coating and their consequential effects on bone and cell line biocompatibility. On the specific date of November 2023, an exhaustive electronic search was conducted in esteemed databases such as PubMed, Web of Science, and Scopus, utilizing the meticulously chosen keywords ((titanium) AND ((osteoblasts) and hydroxyapatite)). Methodologically, the systematic review meticulously adhered to the PRISMA protocol. Initially, a total of 1739 studies underwent scrutiny, with the elimination of 741 duplicate records. A further 972 articles were excluded on account of their incongruence with the predefined subjects. The ultimate compilation embraced 26 studies, with a predominant focus on the effects of nanohydroxyapatite coating in isolation. However, a subset of nine papers delved into the nuanced realm of its modifiers, encompassing materials such as chitosan, collagen, silver particles, or gelatine. Across many of the selected studies, the application of nanohydroxyapatite coating exhibited a proclivity to enhance the osseointegration process. The modifications thereof showcased a positive influence on cell lines, manifesting in increased cellular spread or the attenuation of bacterial activity. In clinical applications, this augmentation potentially translates into heightened implant stability, thereby amplifying the overall procedural success rate. This, in turn, renders nanohydroxyapatite-coated implants a viable and potentially advantageous option in clinical scenarios where non-modified implants may not suffice.
PubMed: 38391898
DOI: 10.3390/jfb15020045 -
National Journal of Maxillofacial... 2023Bone metabolism is a key factor for successful osseointegration, and low vitamin D levels may negatively impact the process of osseointegration after implant placement.... (Review)
Review
Bone metabolism is a key factor for successful osseointegration, and low vitamin D levels may negatively impact the process of osseointegration after implant placement. The study was aimed at evaluating the relation of vitamin D levels with dental implant osseointegration and subsequently the success or failure of the implant. The focused questions were-What is the effect of vitamin D levels on successful dental implant osseointegration and what is the effect of vitamin D supplementation on successful implant osseointegration? A search was conducted on PubMed and Google Scholar using the terms "vitamin D," "cholecalciferol," "1,25(OH) D," "dental implant," "osseointegration," and "bone implant contact" for a period of 10 years from 2011 to 2020. Clinical trials, cross-sectional studies, case series, and case reports were included. A total of ten studies were included after the screening process. Five of these studies evaluated the effect of vitamin D supplementation on osseointegration, whereas five only evaluated the effect of vitamin D deficiency on dental implant osseointegration. Only five of these studies reported dental implant failure varying from 7% to 13% in vitamin D deficient/insufficient groups. Positive relationship exists between serum vitamin D levels and dental implant osseointegration; however, few studies failed to report any relation. More prospective clinical research studies as well as randomized controlled trials are needed to show a significant correlation between decreased serum levels of vitamin D and increased risk of dental implant failure in perspective of vitamin D supplementation which can promote the osseointegration of dental implants.
PubMed: 38273924
DOI: 10.4103/njms.njms_192_22 -
Nutrients Jan 2024This systematic review evaluates the impact of Vitamin D levels on dental implant osseointegration, hypothesizing that optimal Vitamin D enhances success rates, and aims... (Review)
Review
This systematic review evaluates the impact of Vitamin D levels on dental implant osseointegration, hypothesizing that optimal Vitamin D enhances success rates, and aims to synthesize data on its relationship with clinical outcomes in implantology. A comprehensive search across PubMed, Cochrane Library, and Web of Science databases included seven peer-reviewed articles meeting the criteria for the review. These studies, conducted between 2008 and 2021, included human subjects and explicitly correlated serum Vitamin D levels with dental implant outcomes, following PRISMA guidelines. The selected studies involved 1462 participants and examined 4450 dental implants. Key findings included a varied implant loss rate ranging from 3.9% to 11.4% across the studies. One study reported a 9.8% implant loss rate, yet found no significant association between Vitamin D receptor polymorphism and implant success. Another study indicated successful implantation following Vitamin D3 supplementation, even in severe deficiency cases. The highest implant loss rate (11.1%) was observed in severely Vitamin D-deficient patients, particularly when compounded by risk factors such as smoking and periodontal disease. Additionally, one study noted significantly improved bone density following post-surgical Vitamin D supplementation for up to 12 weeks. The review supports a link between sufficient Vitamin D levels and successful dental implant osseointegration, suggesting Vitamin D deficiency as a potential risk factor for increased failure and advocating for Vitamin D evaluations in pre-surgical planning to potentially enhance implantology outcomes.
Topics: Humans; Vitamin D; Dental Implants; Osseointegration; Vitamins; Cholecalciferol
PubMed: 38257102
DOI: 10.3390/nu16020209 -
Revista Espanola de Cirugia Ortopedica... 2024The purpose of this study is to analyse the indications, complications, survivorship and clinical/functional outcome of metaphyseal sleeves as a treatment option in... (Review)
Review
BACKGROUND AND OBJECTIVES
The purpose of this study is to analyse the indications, complications, survivorship and clinical/functional outcome of metaphyseal sleeves as a treatment option in revision total knee arthroplasty.
MATERIAL AND METHOD
A systematic review was made following the PRISMA recommendations on the use of metaphyseal sleeves for revision total knee arthroplasty. We included prospective and retrospective studies published in the last 10 years looking at implant survivorship, clinical and functional outcome with a minimum follow-up of 2 years.
RESULTS
The included studies showed good both functional and clinical outcomes. The overall reoperation rate was 16.2%, with an overall survival rate of 92.2% and aseptic survivorship of 98.2%.
CONCLUSIONS
Metaphyseal sleeves are a good treatment option for this surgery, especially in AORI II or III type bone defects, achieving good intraoperative and primary stability of the implant, with good and rapid osseointegration.
PubMed: 38232929
DOI: 10.1016/j.recot.2024.01.006