Journal of Orthopaedic Surgery and... Jun 2024In recent years, the zero-profile implant (Zero-p) has emerged as a promising internal fixation technique. Although studies have indicated its potential superiority over... (Meta-Analysis)
Meta-Analysis Comparative Study
Comparative efficacy of zero-profile implant and conventional cage-plate implant in the treatment of single-level degenerative cervical spondylosis: a systematic review and meta-analysis.
BACKGROUND
In recent years, the zero-profile implant (Zero-p) has emerged as a promising internal fixation technique. Although studies have indicated its potential superiority over conventional cage-plate implant (Cage-plate) in the treatment of degenerative cervical spondylosis, there remains a lack of definitive comparative reports regarding its indications, safety, and efficacy.
METHODS
A computerized search was conducted on English and Chinese databases, including PubMed, Web of Science, Cochrane Library, EMBASE, CNKI, Wanfang and VIP. Additionally, a manual search was meticulously carried out on Chinese medical journals, spanning from the inception of the respective databases until August 2023. The meta-analysis utilized a case-control study approach and was executed through the utilization of RevMan 5.3 software. Stringent quality evaluation and data extraction procedures were implemented to guarantee the reliability and validity of the findings.
RESULTS
Nine high-quality studies with 808 patients were included. Meta-analysis showed that the operation time (MD = - 13.28; 95% CI (- 17.53, - 9.04), P < 0.00001), intraoperative blood loss (MD = - 6.61; 95% CI (- 10.47, - 2.75), P = 0.0008), incidence of postoperative dysphagia at various time points: within the first month after surgery (OR = 0.36; 95% CI (0.22, 0.58), P < 0.0001), 1-3 months after surgery (OR = 0.20; 95% CI (0.08, 0.49), P = 0.0004), the final follow-up (OR = 0.21; 95% CI (0.05, 0.83), P = 0.003) and the rate of postoperative adjacent disc degeneration (OR = 0.46; 95% CI (0.25, 0.84), P = 0.01) were significantly lower in the Zero-p group than in the Cage-plate group. Additionally, was also significantly lower in the Zero-p group. However, there were no significant differences in the JOA score, the final follow-up NDI score, surgical segmental fusion rate, postoperative height of adjacent vertebrae, or postoperative subsidence rate between the two groups.
CONCLUSION
In summary, when treating single-segment degenerative cervical spondylosis, both internal fixation techniques are reliable and effective. However, Zero-P implant offer several advantages over cage-plate implant, including shorter operation duration, less intraoperative blood loss, reduced postoperative dysphagia, and slower adjacent disc degeneration. Additionally, Zero-P implant has a broader application space, making them a preferred choice in certain cases.
Topics: Humans; Cervical Vertebrae; Spondylosis; Bone Plates; Treatment Outcome; Postoperative Complications; Operative Time; Spinal Fusion; Male; Blood Loss, Surgical; Female; Internal Fixators
PubMed: 38898517
DOI: 10.1186/s13018-024-04729-5 -
Acta Odontologica Scandinavica Jun 2024To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for...
OBJECTIVES
To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for patients with partial or total maxillary and mandibular defects.
MATERIALS AND METHODS
An electronic search was performed in PubMed, SCOPUS, and Web of Science using a combination of relevant keywords: digital workflow, digital designing, computer-assisted design-computer aided manufacturing, 3D printing, maxillectomy, and mandibulectomy. The Joanna Briggs Institute Critical Appraisal Tool was used to assess the quality of evidence in the studies reviewed.
RESULTS
From a total of 542 references, 33 articles were selected, including 25 on maxillary prostheses and 8 on mandibular prostheses. The use of digital workflows was limited to one or two steps of the fabrication of the prostheses, and only four studies described a complete digital workflow. The most preferred method for data acquisition was intraoral scanning with or without a cone beam computed tomography combination.
CONCLUSION
Currently, the fabrication process of maxillofacial prostheses requires combining digital and conventional methods. Simplifying the data acquisition methods and providing user-friendly and affordable software may encourage clinicians to use the digital workflow more frequently for patients requiring maxillofacial prostheses.
Topics: Humans; Workflow; Maxillofacial Prosthesis; Computer-Aided Design; Feasibility Studies; Printing, Three-Dimensional; Software; Prosthesis Design
PubMed: 38895776
DOI: 10.2340/aos.v83.40870 -
Clinical Cardiology Jun 2024Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally,... (Comparative Study)
Comparative Study Meta-Analysis
Temporal Trends in the Outcomes of Percutaneous Coronary Intervention With Zotarolimus Eluting Stents Versus Everolimus Eluting Stents: A Meta-Analysis of Randomized Controlled Trials.
INTRODUCTION
Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally, over the last decade, there have been new trials comparing the ZES with various commercially available EES. We aim to conduct an updated meta-analysis in light of new evidence from randomized controlled trials (RCTs) to provide comprehensive evidence regarding the temporal trends in the clinical outcomes.
METHODS
A comprehensive literature search was conducted across PubMed, Cochrane, and Embase. RCTs comparing ZES with EES for short (<2 years), intermediate (2-3 years), and long-term follow-ups (3-5 years) were included. Relative risk was used to pool the dichotomous outcomes using the random effects model employing the inverse variance method. All statistical analysis was conducted using Revman 5.4.
RESULTS
A total of 18 studies reporting data at different follow-ups for nine trials (n = 14319) were included. At short-term follow-up (<2 years), there were no significant differences between the two types of stents (all-cause death, cardiac death, Major adverse cardiovascular events (MACE), target vessel myocardial infarction, definite or probable stent thrombosis or safety outcomes (target vessel revascularization, target lesion revascularization, target vessel failure, target lesion failure). At intermediate follow-up (2-3 years), EES was superior to ZES for reducing target lesion revascularization (RR = 1.28, 95% CI = 1.05-1.58, p < 0.05). At long-term follow-up (3-5 years), there were no significant differences between the two groups for any of the pooled outcomes (p > 0.05).
CONCLUSION
ZES and EES have similar safety and efficacy at short, intermediate, and long-term follow-ups.
Topics: Humans; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Risk Factors; Sirolimus; Time Factors; Treatment Outcome
PubMed: 38888152
DOI: 10.1002/clc.24306 -
BMC Pulmonary Medicine Jun 2024Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential...
BACKGROUND
Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential harms of rapamycin-eluting stents. Herein, We report a case of eosinophilia and interstitial pneumonia caused by a cobalt-based alloy stent eluted with rapamycin.
CASE PRESENTATION
The patient was admitted due to fever, cough, and expectoration symptoms. Previously, the patient had undergone a procedure of percutaneous coronary stent implantation in our hospital's cardiology department, which led to a gradual rise in blood eosinophil count. This time, the eosinophil count was higher than the previous admission. A chest CT scan revealed multiple flocculent density increases in both lungs and bronchiectasis. The rapamycin-eluting stents may have caused eosinophilia and interstitial pneumonia, which improved after administering corticosteroids. A systematic review of relevant literature was conducted to summarize the characteristics of interstitial pneumonia caused by drug-eluting stents.
CONCLUSION
Paclitaxel, everolimus, zotarolimus, and rapamycin are the types of drugs that can lead to drug-eluting stents, and because of the rarity of their onset, clinical doctors must be precise and prompt in diagnosing suspected cases to avoid misdiagnosis and delayed treatment.
Topics: Humans; Lung Diseases, Interstitial; Drug-Eluting Stents; Sirolimus; Eosinophilia; Male; Tomography, X-Ray Computed; Percutaneous Coronary Intervention; Aged
PubMed: 38886703
DOI: 10.1186/s12890-024-03101-x -
Frontiers in Cardiovascular Medicine 2024In recent years, the use of artificial intelligence (AI) models to generate individualised risk assessments and predict patient outcomes post-Transcatheter Aortic Valve...
OBJECTIVES
In recent years, the use of artificial intelligence (AI) models to generate individualised risk assessments and predict patient outcomes post-Transcatheter Aortic Valve Implantation (TAVI) has been a topic of increasing relevance in literature. This study aims to evaluate the predictive accuracy of AI algorithms in forecasting post-TAVI mortality as compared to traditional risk scores.
METHODS
Following the Preferred Reporting Items for Systematic Reviews and Meta-analyses for Systematic Reviews (PRISMA) standard, a systematic review was carried out. We searched four databases in total-PubMed, Medline, Embase, and Cochrane-from 19 June 2023-24 June, 2023.
RESULTS
From 2,239 identified records, 1,504 duplicates were removed, 735 manuscripts were screened, and 10 studies were included in our review. Our pooled analysis of 5 studies and 9,398 patients revealed a significantly higher mean area under curve (AUC) associated with AI mortality predictions than traditional score predictions (MD: -0.16, CI: -0.22 to -0.10, < 0.00001). Subgroup analyses of 30-day mortality (MD: -0.08, CI: -0.13 to -0.03, = 0.001) and 1-year mortality (MD: -0.18, CI: -0.27 to -0.10, < 0.0001) also showed significantly higher mean AUC with AI predictions than traditional score predictions. Pooled mean AUC of all 10 studies and 22,933 patients was 0.79 [0.73, 0.85].
CONCLUSION
AI models have a higher predictive accuracy as compared to traditional risk scores in predicting post-TAVI mortality. Overall, this review demonstrates the potential of AI in achieving personalised risk assessment in TAVI patients.
REGISTRATION AND PROTOCOL
This systematic review and meta-analysis was registered under the International Prospective Register of Systematic Reviews (PROSPERO), under the registration name "All-Cause Mortality in Transcatheter Aortic Valve Replacement Assessed by Artificial Intelligence" and registration number CRD42023437705. A review protocol was not prepared. There were no amendments to the information provided at registration.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/, PROSPERO (CRD42023437705).
PubMed: 38883982
DOI: 10.3389/fcvm.2024.1343210 -
BMC Cardiovascular Disorders Jun 2024Stent restenosis is a relatively common phenomenon among patients with coronary heart disease undergoing percutaneous coronary intervention (PCI). It seems that a set of...
BACKGROUND
Stent restenosis is a relatively common phenomenon among patients with coronary heart disease undergoing percutaneous coronary intervention (PCI). It seems that a set of clinical, laboratory, and even genetic factors make people susceptible to such a phenomenon and in fact, this is multi-factorial. We aimed to first determine the underlying clinical and laboratory risk factors for the occurrence of stent re-stenosis after PCI based on a systematic review study, and after that, through a bioinformatics study, to evaluate the related genes and microRNAs with the occurrence of stent re-stenosis.
MAIN TEXT
In the first step, the manuscript databases including Medline, Web of Knowledge, Google Scholar, Scopus, and Cochrane were deeply searched by the two blinded investigators for all eligible studies based on the considered keywords to introduce clinical and laboratory determinants of stent re-stenosis. In the bioinformatic phase, and following a review of the literature to identify genes and microRNAs involved in restenosis, the interaction of each gene with other genes associated with stent re-stenosis was determined by GeneMANIA network analysis and Cytoscape software. Overall, 67 articles (including 40,789 patients) on clinical and biochemical predictors for stent restenosis and 25 articles on genetic determinants of this event were eligible for the final analysis. The predictors for this event were categorized into four subgroups patient-based parameters including traditional cardiovascular risk profiles, stent-based parameters including type and diametric characteristics of the stents used, coronary lesion-based parameters including several two target lesions and coronary involvement severity and laboratory-based parameters particularly related to activation of inflammatory processes. In the bioinformatic phase, we uncovered 42 genes that have been described to be involved in such a phenomenon considering a special position for genes encoding inflammatory cytokines. Also, 12 microRNAs have been pointed to be involved in targeting genes involved in stent re-stenosis.
CONCLUSIONS
The incidence of stent re-stenosis will be the result of a complex interaction of clinical risk factors, laboratory factors mostly related to the activation of inflammatory processes, and a complex network of gene-to-gene interactions.
Topics: Humans; Percutaneous Coronary Intervention; Coronary Restenosis; Stents; Risk Factors; Computational Biology; Coronary Artery Disease; MicroRNAs; Risk Assessment; Genetic Predisposition to Disease; Treatment Outcome; Female; Male; Gene Regulatory Networks; Middle Aged; Aged
PubMed: 38877398
DOI: 10.1186/s12872-024-03955-3 -
Cirugia Y Cirujanos 2024The effect of a pre-operative biliary stent on complications after pancreaticoduodenectomy (PD) remains controversial. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
The effect of a pre-operative biliary stent on complications after pancreaticoduodenectomy (PD) remains controversial.
MATERIALS AND METHOD
We conducted a meta-analysis according to the preferred reporting items for systematic reviews and meta-analyses guidelines, and PubMed, Web of Science Knowledge, and Ovid's databases were searched by the end of February 2023. 35 retrospective studies and 2 randomized controlled trials with a total of 12641 patients were included.
RESULTS
The overall complication rate of the pre-operative biliary drainage (PBD) group was significantly higher than the no-PBD group (odds ratio [OR] 1.46, 95% confidence interval [CI] 1.22-1.74; p < 0.0001), the incidence of post-operative delayed gastric emptying was increased in patients with PBD compared those with early surgery (OR 1.21, 95% CI: 1.02-1.43; p = 0.03), and there was a significant increase in post-operative wound infections in patients receiving PBD with an OR of 2.2 (95% CI: 1.76-2.76; p < 0.00001).
CONCLUSIONS
PBD has no beneficial effect on post-operative outcomes. The increase in post-operative overall complications and wound infections urges the exact indications for PBD and against routine pre-operative biliary decompression, especially for patients with total bilirubin < 250 umol/L waiting for PD.
Topics: Humans; Drainage; Pancreaticoduodenectomy; Preoperative Care; Postoperative Complications; Stents; Surgical Wound Infection; Randomized Controlled Trials as Topic; Gastric Emptying; Ampulla of Vater; Pancreatic Neoplasms; Common Bile Duct Neoplasms
PubMed: 38862121
DOI: 10.24875/CIRU.23000318 -
PloS One 2024Weber Type B fractures often arise from external rotation with the foot supinated or pronated. Altered tibiofibular joint kinematics in Weber B fractures are responsible...
Weber Type B fractures often arise from external rotation with the foot supinated or pronated. Altered tibiofibular joint kinematics in Weber B fractures are responsible for syndesmotic damage seen in Weber B fractures. Weber B fractures are managed using open reduction and internal fixation if displaced. The syndesmosis is injured in up to 40% of cases resulting in an unstable injury with a syndesmotic diastasis. This systematic review aimed to evaluate the current literature on syndesmotic fixation in Weber B fractures, assess the outcomes and complications of syndesmotic fixation and assess the necessity of syndesmotic fixation in Weber B fractures. A search was carried out on the EMBASE, PubMed and CINAHL databases and eight studies assessing the outcomes of syndesmotic fixations versus no syndesmotic fixation with 292 Weber B ankle fractures were included in this systematic review. Results showed significant heterogeneity so a narrative review was conducted. Results of these studies showed that functional, radiological, and quality-of-life outcomes and incidences of post-traumatic osteoarthritis in patients with syndesmotic screws were similar to those of patients not managed with syndesmotic screws. Only one favoured syndesmotic fixation in all cases of diastasis. As such, syndesmotic fixation with screws may not be necessary in the management of Weber B fractures. Screws are also associated with breakage, loosening, local irritation and infections. Suture button devices and antiglide fixation techniques appear to be valid alternatives to syndesmotic screws. It was found that there was no need for routine hardware removal unless the hardware was causing significant side effects for the patient.
Topics: Humans; Ankle Fractures; Fracture Fixation, Internal; Ankle Injuries; Ankle Joint; Bone Screws; Treatment Outcome
PubMed: 38857233
DOI: 10.1371/journal.pone.0304148 -
European Review For Medical and... May 2024Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Periimplantitis (PI) is a complex multifactorial chronic disease caused by interactions between bacteria, host immune-inflammatory responses, and genetic or environmental factors that modify buccal eutrophism. In daily clinical practice, an increase in the prevalence of PI (8%) determined the need to establish the PI causes and set optimal therapeutic strategies. The interleukin family (IL-1), a group of cytokines, triggers and perpetuates peri-implantitis. Therefore, they could be used as biomarkers for diagnosis and treatment. This systematic review aimed to analyze the correlation between IL-1 allelic polymorphism (IL-1A -889, IL-1β -511, IL-1β +3954) and the PI disease.
MATERIALS AND METHODS
Selected databases were PubMed, Scopus, and Cochrane Library. The search strategy included the following terms: "dental implants"; "periimplantitis"; "interleukin-IL-1"; "polymorphism"; "perimplant bone loss". Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. A meta-analysis was conducted on five of 40 review articles. p-values, confidence intervals (CI), and Odds ratios (OR) were assessed. In 4 articles, the p-value was lower than 0.05, confirming the statistical significance of the result.
RESULTS
The prevalence of the selected studies reported the existence of a causal association between polymorphisms of IL-1 and the onset of peri-implantitis, especially for IL-1 allelic variants associated with further polymorphic genes encoding for IL-6, tumor necrosis factor-alpha (TNF-α), matrix metalloproteinases (MMP)-8, IL-1Na, IL-8, IL-18, osteopontin (OPN). In addition, the presence of the IL-1 polymorphism and PI is particularly higher in smokers, diabetes, and autoimmune disease patients.
CONCLUSIONS
The detection of salivary biomarkers is, therefore, a diagnostic tool with a high potential to intercept the PI early and act with appropriate and non-invasive treatment. Due to the continued technological innovation in biomarkers and diagnostic sciences, further studies are needed to investigate the role of these biochemical mediators. The results of studies and the recent technological innovation in biomarkers and diagnostic sciences will allow further research to investigate the role of these biochemical mediators.
Topics: Humans; Peri-Implantitis; Polymorphism, Genetic; Interleukin-1; Dental Implants
PubMed: 38856132
DOI: 10.26355/eurrev_202405_36293 -
European Journal of Medical Research Jun 2024Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a... (Review)
Review
Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a potentially infected hip joint have been judged as being only relevant to exclude diagnoses other than infection. Solid data on radiographic presentations of periprosthetic joint infection (PJI) are scarce. As a result, the prognostic value of radiological features in low-grade PJI remains uncertain. The present review article aims to present an overview of the available literature and to develop ideas on future perspectives to define the diagnostic possibilities of radiography in PJIs of the hip. The primary outcome of interest of this systematic review was the radiologic presentation of periprosthetic joint infections of the hip. As secondary outcome of interest served the sensitivity and specificity of the radiologic presentation of periprosthetic joint infections. Of the included articles, 26 were reviews, essays, or case reports and only 18 were clinical studies. Typical radiologic abnormalities of PJI were a periosteal reaction, a wide band of radiolucency at the cement-bone or metal-bone interface, patchy osteolysis, implant loosening, bone resorption around the implant, and transcortical sinus tracts. The frequency of their occurrence is still inadequately defined. A deeper understanding of the underlying causes and the relation between microorganisms to radiologic abnormalities can probably help clinicians in the future to diagnose a PJI. This is why further research shall focus on the radiographic features of PJI.
Topics: Humans; Prosthesis-Related Infections; Prognosis; Arthroplasty, Replacement, Hip; Radiography; Hip Joint; Hip Prosthesis
PubMed: 38849967
DOI: 10.1186/s40001-024-01891-8