-
Microorganisms Jun 2024Glucocorticoids may be given prior to major orthopedic surgery to decrease postoperative nausea, vomiting, and pain. Additionally, many orthopedic patients may be on...
Glucocorticoids may be given prior to major orthopedic surgery to decrease postoperative nausea, vomiting, and pain. Additionally, many orthopedic patients may be on chronic glucocorticoid therapy. The aim of our study was to investigate whether glucocorticoid administration influences Orthopedic-Device-Related Infection (ODRI) in a rat model. Screws colonized with were implanted in the tibia of skeletally mature female Wistar rats. The treated groups received either a single shot of dexamethasone in a short-term risk study, or a daily dose of dexamethasone in a longer-term interference study. In both phases, bone changes in the vicinity of the implant were monitored with microCT. There were no statistically significant differences in bacteriological outcome with or without dexamethasone. In the interference study, new bone formation was statistically higher in the dexamethasone-treated group ( = 0.0005) as revealed by CT and histopathological analysis, although with relatively low direct osseointegration of the implant. In conclusion, dexamethasone does not increase the risk of developing periprosthetic osteolysis or infection in a pre-clinical model of ODRI. Long-term administration of dexamethasone seemed to offer a benefit in terms of new bone formation around the implant, but with low osseointegration.
PubMed: 38930516
DOI: 10.3390/microorganisms12061134 -
Journal of Clinical Medicine Jun 2024Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate... (Review)
Review
Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate reconstruction is crucial to address complications such as malocclusion, mandibular deviation, temporomandibular joint (TMJ) changes, and soft tissue retraction. These issues can lead to functional impairments, including difficulties in chewing, swallowing, and speech. The fibula flap is widely used for mandibular reconstruction due to its long bone segment and robust vascular supply, though it may not always provide adequate bone height for optimal dental rehabilitation. This systematic review aims to determine if the double-barreled fibula flap (DBFF) configuration is a viable alternative for mandibular reconstruction and to evaluate the outcomes of dental implants placed in this type of flap. This study adhered to the Cochrane Collaboration criteria and PRISMA guidelines and was registered on the International Platform of Registered Systematic Review and Meta-Analysis Protocols Database (INPLASY2023120026). We included clinical studies published in English, Spanish, or French that focused on adult patients undergoing segmental mandibulectomy followed by DBFF reconstruction and dental rehabilitation. Data sources included Medline/PubMed, the Cochrane Library, EMBASE, Scopus, and manual searches. Two reviewers independently screened and selected studies, with discrepancies resolved by a third reviewer. Data extraction captured variables such as publication year, patient demographics, number of implants, follow-up duration, flap survival, implant failure, and aesthetic outcomes. The risk of bias was assessed using the JBI appraisal tool, and the certainty of evidence was evaluated using the GRADE approach. A total of 17 clinical studies were included, evaluating 245 patients and 402 dental implants. The average patient age was 43.7 years, with a mean follow-up period of 34.3 months. Flap survival was high, with a 98.3% success rate and only four flap losses. The implant failure rate was low at 1.74%. Esthetic outcomes were varied, with only three studies using standardized protocols for evaluation. The overall certainty of evidence for flap survival was moderate, low for implant failure, and very low for aesthetics due to the subjective nature of assessments and variability in reporting. The primary limitations of the evidence included in this review are the observational design of the studies, leading to an inherent risk of bias, inconsistency in reporting methods, and imprecision in outcome measures. Additionally, the subjective nature of aesthetic evaluations and the variability in assessment tools further limit the reliability of the findings. The DBFF technique demonstrates excellent outcomes for mandibular reconstruction, with high flap survival and low implant failure rates, making it a viable option for dental rehabilitation. However, the evidence for aesthetic outcomes is less certain, highlighting the need for more rigorous and standardized research. This review supports the DBFF as a good alternative for mandibular reconstruction with successful dental implant integration, although further studies are needed to enhance the reliability of aesthetic evaluations.
PubMed: 38930078
DOI: 10.3390/jcm13123547 -
Medicina (Kaunas, Lithuania) May 2024: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets... (Meta-Analysis)
Meta-Analysis Comparative Study Review
: The present systematic review and meta-analysis were conducted to evaluate and compare the long-term clinical outcomes of immediate implants placed into fresh sockets with and without periapical pathology. : After the search and review of the literature in the electronic databases, 109 publications were achieved. The titles and abstracts of 66 publications were screened. After the evaluation of the full text of 22 publications, based on the inclusion criteria, six controlled clinical studies were included in this systematic review and meta-analysis. The statistical calculation showed no heterogeneity among the studies included. The implant survival was 99.6% in the test (socket with periapical pathology) and control (socket without periapical pathology) groups of all the clinical trials. The results of the meta-analysis showed no statistically significant difference between test and control groups regarding the marginal bone level and the width of keratinized mucosa in all the studies. Other parameters indicating plaque level, bleeding on probing, and gingival recession also did not differ between test and control groups at the final follow-up in nearly all studies. : Within the limitation of this systemic review and meta-analysis, the obtained data suggest that implants immediately placed into the extraction sockets of teeth exhibiting periapical pathology can be successfully osseointegrated for an extended period.
Topics: Humans; Tooth Socket; Dental Implantation, Endosseous; Dental Implants; Immediate Dental Implant Loading
PubMed: 38929509
DOI: 10.3390/medicina60060893 -
Bioengineering (Basel, Switzerland) Jun 2024(1) Background: When placing implants in the maxillary posterior region with insufficient alveolar bone, a maxillary sinus elevation is necessary. Autogenous bone,...
(1) Background: When placing implants in the maxillary posterior region with insufficient alveolar bone, a maxillary sinus elevation is necessary. Autogenous bone, though biologically ideal, poses risks and discomfort due to donor site harvesting. Block-type autogenous tooth bone graft material, made from the patient's own extracted tooth, offers similar biological stability without these drawbacks. (2) Methods: This study observed the progress of 19 implant patients who were treated with maxillary sinus elevation procedures using block-type autogenous tooth bone graft material at the Daegu Catholic University Medical Center. Extracted teeth were processed into demineralized tooth block bone. After elevating the sinus membrane, implants and the tooth bone graft material were placed in the space, and the bony window was repositioned. Postoperative evaluations through clinical observation and radiographic imaging assessed sinus membrane elevation, alveolar bone height increase, and implant osseointegration. (3) Results: Results showed proportional increases in alveolar bone height to the graft material size, with long-term stability. No postoperative complications occurred, even with sinus membrane perforation, and implants remained stable. (4) Conclusions: The study concludes that maxillary sinus lifts using block-type autogenous tooth bone graft material provide excellent bone induction and biocompatibility, making this a highly beneficial method for both dentists and patients.
PubMed: 38927869
DOI: 10.3390/bioengineering11060633 -
Journal of Applied Oral Science :... 2024to evaluate the morphological and functional characteristics of the peri-implant bone tissue that was formed during the healing process by the placement implants using...
OBJECTIVES
to evaluate the morphological and functional characteristics of the peri-implant bone tissue that was formed during the healing process by the placement implants using two different surface treatments: hydrophilic Acqua™ (ACQ) and rough NeoPoros™ (NEO), in spontaneously hypertensive (SHR) and normotensive rats (Wistar) whether or not treated with losartan.
METHODOLOGY
In total, 96 male rats (48 Wistar and 48 SHR) were divided into eight subgroups: absolute control rough (COA NEO), absolute control hydrophilic (COA ACQ), losartan control rough (COL NEO), losartan control hydrophilic (COL ACQ), SHR absolute rough (SHR NEO), SHR absolute hydrophilic (SHR ACQ), SHR losartan rough (SHRL NEO), and SHR losartan hydrophilic (SHRL ACQ). The rats medicated with losartan received daily doses of the medication. NeoPoros™ and Acqua™ implants were installed in the tibiae of the rats. After 14 and 42 days of the surgery, the fluorochromes calcein and alizarin were injected in the rats. The animals were euthanized 67 days after treatment. The collected samples were analyzed by immunohistochemistry, biomechanics, microcomputerized tomography, and laser confocal scanning microscopy analysis.
RESULTS
The osteocalcin (OC) and vascular endothelium growth factor (VEGF) proteins had moderate expression in the SHRL ACQ subgroup. The same subgroup also had the highest implant removal torque. Regarding microarchitectural characteristics, a greater number of trabeculae was noted in the control animals that were treated with losartan. In the bone mineralization activity, it was observed that the Acqua™ surface triggered higher values of MAR (mineral apposition rate) in the COA, COL, and SHRL groups (p<0.05).
CONCLUSION
the two implant surface types showed similar responses regarding the characteristics of the peri-implant bone tissue, even though the ACQ surface seems to improve the early stages of osseointegration.
Topics: Animals; Losartan; Rats, Inbred SHR; Rats, Wistar; Male; Surface Properties; Dental Implants; Time Factors; X-Ray Microtomography; Reproducibility of Results; Immunohistochemistry; Hydrophobic and Hydrophilic Interactions; Osseointegration; Treatment Outcome; Dental Implantation, Endosseous; Microscopy, Confocal; Tibia; Analysis of Variance; Biomechanical Phenomena; Reference Values; Osteocalcin
PubMed: 38922240
DOI: 10.1590/1678-7757-2023-0374 -
Brazilian Oral Research 2024The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical...
The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography. A significant difference was noted in the ISQ values between t1 and t2 in type III bone for EH and MT implants. No significant difference in bone loss values was observed when comparing bone types for EH or MT in all evaluated sites. Based on marginal bone loss assessed using radiography, there was no significant difference between the MT and EH groups. A positive correlation between torque and ISQ t1 value was observed for MT (correlation: 0.439; p = 0.041) and EH (correlation: 0.461; p = 0.031) implants. For EH and MT implants, the greater the insertion torque, the greater was the ISQ value (moderately positive correlation). A weak negative correlation was found between bone type and ISQ t1 for MT implants. Contrarily, no correlation was observed between bone type and ISQ t1 for EH implants. In all cases, bone loss around the implants was clinically normal.
Topics: Humans; Torque; Male; Female; Alveolar Bone Loss; Osseointegration; Dental Implantation, Endosseous; Middle Aged; Reference Values; Time Factors; Treatment Outcome; Statistics, Nonparametric; Dental Prosthesis Design; Adult; Mandible; Dental Prosthesis Retention; Aged; Resonance Frequency Analysis; Dental Implants; Maxilla; Dental Implants, Single-Tooth; Reproducibility of Results
PubMed: 38922209
DOI: 10.1590/1807-3107bor-2024.vol38.0049 -
Journal of Functional Biomaterials Jun 2024The objective of this work was to analyze the in vitro and in vivo tests of a novel Mg-based biodegradable alloy-Mg-0.5%Ca-with various amounts of Zn (0.5, 1, 1.5, 2.0,...
The objective of this work was to analyze the in vitro and in vivo tests of a novel Mg-based biodegradable alloy-Mg-0.5%Ca-with various amounts of Zn (0.5, 1, 1.5, 2.0, and 3.0 wt.%). In terms of in vitro biocompatibility, MTT and Calcein-AM cell viability assays, performed on the MG-63 cell line through the extract method, revealed that all five alloy extracts are non-cytotoxic at an extraction ratio of 0.025 g alloy per mL of cell culture medium. In the in vivo histological analysis, Mg-0.5Ca-1.5Zn demonstrated exceptional potential for stimulating bone remodeling and showed excellent biocompatibility. It was observed that Mg-0.5Ca-0.5Zn, Mg-0.5Ca-1.5Zn, and Mg-0.5Ca-3Zn displayed good biocompatibility. Furthermore, the histological examination highlighted the differentiation of periosteal cells into chondrocytes and subsequent bone tissue replacement through endochondral ossification. This process highlighted the importance of the initial implant's integrity and the role of the periosteum. In summary, Mg-0.5Ca-1.5Zn stands out as a promising candidate for bone regeneration and osseointegration, supported by both in vitro and in vivo findings.
PubMed: 38921539
DOI: 10.3390/jfb15060166 -
Journal of Functional Biomaterials Jun 2024The advent of three-dimensional (3D) printing technology has revolutionized the field of dentistry, enabling the precise fabrication of dental implants. By utilizing 3D...
BACKGROUND
The advent of three-dimensional (3D) printing technology has revolutionized the field of dentistry, enabling the precise fabrication of dental implants. By utilizing 3D printing, dentists can devise implant plans prior to surgery and accurately translate them into clinical procedures, thereby eliminating the need for multiple surgical procedures, reducing surgical discomfort, and enhancing surgical efficiency. Furthermore, the utilization of digital 3D-printed implant guides facilitates immediate restoration by precisely translating preoperative implant design plans, enabling the preparation of temporary restorations preoperatively.
METHODS
This comprehensive study aimed to assess the postoperative oral health status of patients receiving personalized 3D-printed implants and investigate the advantages and disadvantages between the 3D-printed implant and conventional protocol. Additionally, variance analysis was employed to delve into the correlation between periodontal status and overall oral health. Comparisons of continuous paired parameters were made by -test.
RESULTS
The results of our study indicate a commendable one-year survival rate of over 94% for 3D-printed implants. This finding was corroborated by periodontal examinations and follow-up surveys using the Oral Health Impact Profile-14 (OHIP-14) questionnaire, revealing excellent postoperative oral health status among patients. Notably, OHIP-14 scores were significantly higher in patients with suboptimal periodontal health, suggesting a strong link between periodontal health and overall oral well-being. Moreover, we found that the operating time (14.41 ± 4.64 min) was less statistically significant than for the control group (31.76 ± 6.83 min).
CONCLUSION
In conclusion, personalized 3D-printed implant surgery has emerged as a reliable clinical option, offering a viable alternative to traditional implant methods. However, it is imperative to gather further evidence-based medical support through extended follow-up studies to validate its long-term efficacy and safety.
PubMed: 38921530
DOI: 10.3390/jfb15060156 -
Biomimetics (Basel, Switzerland) May 2024The aging population and increasing incidence of trauma among younger age groups have heightened the increasing demand for reliable implant materials. Effective implant...
The aging population and increasing incidence of trauma among younger age groups have heightened the increasing demand for reliable implant materials. Effective implant materials must demonstrate rapid osseointegration and strong antibacterial properties to ensure optimal patient outcomes and decrease the chance of implant rejection. This study aims to enhance the bone-implant interface by utilizing 45S5 bioglass modified with various concentrations of FeO as a coating material. The effect of the insertion of FeO into the bioglass structure was studied using Raman spectroscopy which shows that with the increase in FeO concentration, new vibration bands associated with Fe-related structural units appeared within the sample. The bioactivity of the prepared glasses was evaluated using immersion tests in simulated body fluid, revealing the formation of a calcium phosphate-rich layer within 24 h on the samples, indicating their potential for enhanced tissue integration. However, the sample modified with 8 mol% of FeO showed low reactivity, developing a calcium phosphate-rich layer within 96 h. All the bioglasses showed antibacterial activity against the and bacteria. The modified bioglass did not present significant antibacterial properties compared to the bioglass base.
PubMed: 38921205
DOI: 10.3390/biomimetics9060325 -
Annals of Translational Medicine Jun 2024
PubMed: 38911558
DOI: 10.21037/atm-24-10