Bioactive Materials Sep 2024Zirconium-based metallic glasses (Zr-MGs) are demonstrated to exhibit high mechanical strength, low elastic modulus and excellent biocompatibility, making them promising...
Zirconium-based metallic glasses (Zr-MGs) are demonstrated to exhibit high mechanical strength, low elastic modulus and excellent biocompatibility, making them promising materials for endosseous implants. Meanwhile, tantalum (Ta) is also well known for its ideal corrosion resistance and biological effects. However, the metal has an elastic modulus as high as 186 GPa which is not comparable to the natural bone (10-30 GPa), and it also has a relative high cost. Here, to fully exploit the advantages of Ta as endosseous implants, a small amount of Ta (as low as 3 at. %) was successfully added into a Zr-MG to generate an advanced functional endosseous implant, ZrCuAlTa MG, with superior comprehensive properties. Upon carefully dissecting the atomic structure and surface chemistry, the results show that amorphization of Ta enables the uniform distribution in material surface, leading to a significantly improved chemical stability and extensive material-cell contact regulation. Systematical analyses on the immunological, angiogenesis and osteogenesis capability of the material are carried out utilizing the next-generation sequencing, revealing that ZrCuAlTa MG can regulate angiogenesis through VEGF signaling pathway and osteogenesis via BMP signaling pathway. Animal experiment further confirms a sound osseointegration of ZrCuAlTa MG in achieving better bone-implant-contact and inducing faster peri-implant bone formation.
PubMed: 38800719
DOI: 10.1016/j.bioactmat.2024.04.014 -
Materials (Basel, Switzerland) May 2024Titanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to...
Bone-to-Implant Contact in Implants with Plasma-Treated Nanostructured Calcium-Incorporated Surface (XPEEDActive) Compared to Non-Plasma-Treated Implants (XPEED): A Human Histologic Study at 4 Weeks.
Titanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to significantly reduce surface hydrocarbons, thus improving implant hydrophilicity and enhancing the osseointegration process. This study investigates the effect of plasma surface treatment on bone-to-implant contact (BIC) of implants presenting a nanostructured calcium-incorporated surface (XPEED). Following a Randomized Controlled Trial (RCT) design, patients undergoing implant surgery in the posterior maxilla received additional plasma-treated (n = 7) or -untreated (n = 5) 3.5 × 8 mm implants that were retrieved after a 4-week healing period for histological examination. Histomorphometric analysis showed that plasma-treated implants exhibited a 38.7% BIC rate compared to 22.4% of untreated implants ( = 0.002), indicating enhanced osseointegration potential. Histological images also revealed increased bone formation and active osteoblastic activity around plasma-treated implants when compared to untreated specimens. The findings suggest that plasma treatment improves surface hydrophilicity and biological response, facilitating early bone formation around titanium implants. This study underscores the importance of surface modifications in optimizing implant integration and supports the use of plasma treatment to enhance osseointegration, thereby improving clinical outcomes in implant dentistry and offering benefits for immediate and early loading protocols, particularly in soft bone conditions.
PubMed: 38793397
DOI: 10.3390/ma17102331 -
Materials (Basel, Switzerland) May 2024The present study investigated the in vivo bone-forming efficacy of an innovative titanium (Ti) dental implant combined with a collagen sponge containing recombinant...
The present study investigated the in vivo bone-forming efficacy of an innovative titanium (Ti) dental implant combined with a collagen sponge containing recombinant human bone morphogenetic protein-2 (BMP-2) in a pig model. Two different concentrations of BMP-2 (20 and 40 µg/mL) were incorporated into collagen sponges and placed at the bottom of Ti dental implants. The investigated implants were inserted into the edentulous ridge at the canine-premolar regions of Lanyu small-ear pigs, which were then euthanized at weeks 1, 2, 4, 8, and 12 post-implantation. Specimens containing the implants and surrounding bone tissue were collected for histological evaluation of their bone-to-implant contact (BIC) ratios and calculation of maximum torques using removal torque measurement. Analytical results showed that the control and BMP-2-loaded implants presented good implant stability and bone healing for all testing durations. After 1 week of healing, the BMP-2-loaded implants with a concentration of 20 µg/mL exhibited the highest BIC ratios, ranging from 58% to 76%, among all groups ( = 0.034). Additionally, they also possessed the highest removal torque values (50.1 ± 1.3 N-cm) throughout the 8-week healing period. The BMP-2-loaded implants not only displayed excellent in vivo biocompatibility but also presented superior osteoinductive performance. Therefore, these findings demonstrate that BMP-2 delivered through a collagen sponge can potentially enhance the early-stage osseointegration of Ti dental implants.
PubMed: 38793339
DOI: 10.3390/ma17102276 -
Materials (Basel, Switzerland) May 2024The aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and...
The aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy (EDS), Atomic Force Microscopy (AFM), optical profilometer, drop shape analyzer, and a nanoscratch tester. All of the coatings are homogeneous without any agglomerates. When low voltage (10 V) was used, the coatings were uniform and continuous regardless of the deposition time. The increase in voltage resulted in the formation of cracks in the coatings. The wettability test shows the hydrophilic behavior of the coatings and the mean contact angle values are in the range of 20-37°. The coatings showed excellent adhesion to the substrate. The application of a maximum force of 400 mN did not cause delamination in most coatings. It is concluded that the optimal coating for orthopedic implants (such as hip joint implants, knee joint implants or facial elements) is obtained at 10 V and 5 min because of its homogeneity, and a contact angle that promotes osseointegration and great adhesion to the substrate.
PubMed: 38793310
DOI: 10.3390/ma17102242 -
Journal of Clinical Medicine May 2024Although xenografts have shown successful results in GBR procedures due to their osteoconductive properties, many authors have opted to add co-adjuvant drugs to favor...
Although xenografts have shown successful results in GBR procedures due to their osteoconductive properties, many authors have opted to add co-adjuvant drugs to favor osteogenesis and differentiate cells into an osteoblastic lineage. Metformin has been shown to have bone-protective properties, regulating osteoclast differentiation, as well as the ability to promote osteoblast mineralization and differentiation. The present study aimed to evaluate the effect of the local application of a 1% metformin solution on bone neoformation in the treatment of an experimental bone defect in a guided bone regeneration animal model with a particulated bovine hydroxyapatite xenograft with hyaluronate. With this purpose in mind, two critical defects with 8 mm diameter and 0.5 mm depth were created in eight male New Zealand rabbit calvarias. Titanium cylinders were fixed in each defect and filled with particulate hydroxyapatite of bovine origin and sodium hyaluronate, with sterile injectable saline added to the control group and sterile 1% metformin solution added to the test group. At 6 weeks, the animals were euthanized, and samples were obtained and prepared for histomorphometric analysis. A higher percentage of new bone formation was observed in the metformin samples than in the control samples, both in the region closest to the animal's calvaria and in the most distal region analyzed. A higher average bone-biomaterial contact percentage was observed in the samples, with metformin in both the proximal and distal regions. There was no statistically significant difference in the mean value in either region in both parameters. The local application of a 1% metformin solution in an animal model of guided bone regeneration with particulate bovine hydroxyapatite and hyaluronate resulted in greater bone neoformation and xenograft osseointegration than in the control group.
PubMed: 38792514
DOI: 10.3390/jcm13102973 -
Journal of Clinical Medicine May 2024To ensure that implants are able to support prosthetic rehabilitation, a stable and functional union between the bone and the implant surface is crucial to its...
To ensure that implants are able to support prosthetic rehabilitation, a stable and functional union between the bone and the implant surface is crucial to its stability and success. To increase bone volume and density and excel bone-implant contact, a novel drilling method, called osseodensification (OD), was performed. To assess the effectiveness of the osseodensification drilling protocol versus the conventional surgical technique on implant stability. Bone Level Tapered Straumann implants were placed side-by-side with both OD and subtractive conventional drilling (SD) in 90 patients from CESPU-Famalicão clinical unit. IT was measured using a manual torque wrench, and the Implant stability quotient (ISQ) value was registered using the Osstell IDX. According to the multifactorial ANOVA, there were statistically significant differences in the mean IT values due to the arch only (F(1.270) = 4.702, -value = 0.031 < 0.05). Regarding the length of the implant, there were statistically significant differences in the mean IT in the OD group ( = 0.041), with significantly lower mean IT values for the Regular implants compared to the Long. With respect to the arch, the analyses of the overall ISQ values showed an upward trend in both groups in the maxilla and mandible. High levels of IT also showed high ISQ values, which represent good indicators of primary stability. OD does not have a negative influence on osseointegration compared to conventional subtractive osteotomy.
PubMed: 38792453
DOI: 10.3390/jcm13102912 -
An Advanced Human Bone Tissue Culture Model for the Assessment of Implant Osteointegration In Vitro.International Journal of Molecular... May 2024In the field of biomaterials for prosthetic reconstructive surgery, there is the lack of advanced innovative methods to investigate the potentialities of smart...
In the field of biomaterials for prosthetic reconstructive surgery, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials before in vivo tests. Despite the complex osteointegration process being difficult to recreate in vitro, this study proposes an advanced in vitro tissue culture model of osteointegration using human bone. Cubic samples of trabecular bone were harvested, as waste material, from hip arthroplasty; inner cylindrical defects were created and assigned to the following groups: (1) empty defects (CTRneg); (2) defects implanted with a cytotoxic copper pin (CTRpos); (3) defects implanted with standard titanium pins (Ti). Tissues were dynamically cultured in mini rotating bioreactors and assessed weekly for viability and sterility. After 8 weeks, immunoenzymatic, microtomographic, histological, and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, while Ti appears to have a trophic effect on bone. MicroCT and a histological analysis supported the results, with signs of matrix and bone deposition at the Ti implant site. Data suggest the reliability of the tested model in recreating the osteointegration process in vitro with the aim of reducing and refining in vivo preclinical models.
Topics: Humans; Osseointegration; Titanium; Tissue Culture Techniques; X-Ray Microtomography; Bone and Bones; Biocompatible Materials; Prostheses and Implants; Cancellous Bone
PubMed: 38791362
DOI: 10.3390/ijms25105322 -
British Dental Journal May 2024As utilisation of dental implants continues to rise, so does the incidence of biological complications. When peri-implantitis has already caused extensive bone... (Review)
Review
As utilisation of dental implants continues to rise, so does the incidence of biological complications. When peri-implantitis has already caused extensive bone resorption, the dentist faces the dilemma of which therapy is the most appropriate to maintain the implant. Since non-surgical approaches of peri-implantitis have shown limited effectiveness, the present paper describes different surgical treatment modalities, underlining their indications and limitations. The primary goal in the management of peri-implantitis is to decontaminate the surface of the infected implant and to eliminate deep peri-implant pockets. For this purpose, access flap debridement, with or without resective procedures, has shown to be effective in a large number of cases. These surgical treatments, however, may be linked to post-operative recession of the mucosal margin. In addition to disease resolution, reconstructive approaches also seek to regenerate the bone defect and to achieve re-osseointegration.
Topics: Humans; Peri-Implantitis; Surgical Flaps; Dental Implants; Debridement
PubMed: 38789758
DOI: 10.1038/s41415-024-7405-9 -
British Dental Journal May 2024Peri-implant diseases are frequent complications that occur around osseointegrated endosseous implants and are the result of an imbalance between the bacterial challenge... (Review)
Review
Peri-implant diseases are frequent complications that occur around osseointegrated endosseous implants and are the result of an imbalance between the bacterial challenge and host response. Peri-implant diseases may affect the peri-implant mucosa only (peri-implant mucositis) or also involve the supporting bone (peri-implantitis). Early detection of peri-implant diseases and timely treatment is important for the success of dental implant treatment. Peri-implant probing is essential to assess the peri-implant health status and should be done at each recall visit. Dental practitioners should be familiar with the clinical and radiological features of both conditions in order to make an accurate diagnosis and determine the appropriate treatment required. This article aims to provide clinicians with an understanding of the key differences between peri-implant health, peri-implant mucositis and peri-implantitis.
Topics: Humans; Dental Implants; Mucositis; Peri-Implantitis; Stomatitis
PubMed: 38789756
DOI: 10.1038/s41415-024-7402-z -
British Dental Journal May 2024Dental implants are a regular feature in daily clinical practice and there is a need to undertake routine assessment and maintenance of implants and their restorations... (Review)
Review
Dental implants are a regular feature in daily clinical practice and there is a need to undertake routine assessment and maintenance of implants and their restorations on par with that provided for natural teeth. Occlusal checks form an important part of the maintenance regime for preserving the integrity of implants, their restorations, and health of the peri-implant tissues. Implant restorations are subjected to the full characteristics and magnitude of occlusal forces, including those associated with parafunction. Compared with the periodontal ligament around teeth, the biophysical response to occlusal forces of osseointegration is different through the more rigid link of implant to bone and reduced proprioception. Risks attributable to occlusal forces primarily affect implant restorations and they are elevated in the presence of bruxism. The occlusal guidelines recommended by the literature are aimed at reducing these risks and regular assessment and maintenance of the occlusion is essential. A four-step sequence is presented to ensure that the annual occlusal checks include the patient's input and evaluation of restoration integrity, occlusal scheme, additional protection, and spatial changes.
Topics: Humans; Dental Implants; Bite Force; Dental Occlusion; Bruxism
PubMed: 38789754