-
European Radiology Jun 2024Recent studies have shown the potential of fibroblast activating protein inhibitor (FAPI) PET imaging for pancreatic cancer assessment.
BACKGROUND
Recent studies have shown the potential of fibroblast activating protein inhibitor (FAPI) PET imaging for pancreatic cancer assessment.
PURPOSE
This article is dedicated to comparing the diagnostic efficacy of FAPI PET and [F]fluorodeoxyglucose (FDG) PET in the evaluation of primary tumors, lymph nodes, and distant metastases in pancreatic cancer.
METHODS
In this review, we conducted a systematic search of studies published in PubMed and Web of Science databases up to September 18, 2023. All included studies used radionuclide labeled FAPI and FDG as PET diagnostic tracers to evaluate their applicability in patients with pancreatic cancer.
RESULTS
The FAPI PET imaging group showed significantly higher sensitivity in the detection of primary lesions (1.000, [95% CI: 0.999-1.000]), lymph node metastases (0.624 [95% CI: 0.391-0.834]) and distant metastatic (0.965 [95% CI: 0.804-1.000]) in pancreatic cancer compared to the FDG PET imaging group (0.889 [95% CI: 0.788-0.966], 0.373 [95% CI: 0.163-0.606] and 0.889 [95% CI: 0.689-0.999], respectively). Furthermore, the maximum standardized uptake value (SUVmax) in FAPI PET imaging is significantly higher than that in FDG imaging for primary lesions (mean difference (MD) = 7.51, 95% CI: 5.34-9.67).
CONCLUSION
Compared with [F]FDG PET/CT, FAPI PET imaging showed higher sensitivity, SUVmax. This method can be effectively utilized for the evaluation of pancreatic cancer.
CLINICAL RELEVANCE STATEMENT
Fibroblast activating protein inhibitor PET may be a better alternative to [F]FDG in evaluating primary pancreatic cancer, lymph node metastases, and distant metastases.
KEY POINTS
Fibroblast activating protein inhibitor (FAPI) PET is compared with FDG PET for evaluating pancreatic cancer. Multiple radiolabeled FAPI variants have shown promising results in the diagnosis of pancreatic cancer. FAPI PET imaging effectively helps clinicians diagnose and stage pancreatic cancer.
PubMed: 38907099
DOI: 10.1007/s00330-024-10843-z -
PloS One 2024To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome (AAS) in patients presenting with symptoms suggestive of AAS.
METHODS
We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test (e.g. computer tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models.
RESULTS
We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer>500ng/L. Summary sensitivities and specificities (95% credible interval) were: ADD-RS>0 94.6% (90%, 97.5%) and 34.7% (20.7%, 51.2%), ADD-RS>1 43.4% (31.2%, 57.1%) and 89.3% (80.4%, 94.8%); ADD RS>0 or D-Dimer>500ng/L 99.8% (98.7%, 100%) and 21.8% (12.1%, 32.6%); ADD RS>1 or D-Dimer>500ng/L 98.3% (94.9%, 99.5%) and 51.4% (38.7%, 64.1%); ADD RS>1 or ADD RS = 1 with D-dimer>500ng/L 93.1% (87.1%, 96.3%) and 67.1% (54.4%, 77.7%).
CONCLUSIONS
Combinations of ADD-RS and D-dimer can be used to select patients with suspected AAS for imaging with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%).
Topics: Humans; Fibrin Fibrinogen Degradation Products; Aortic Dissection; Syndrome; Sensitivity and Specificity; Acute Disease; Computed Tomography Angiography; Acute Aortic Syndrome
PubMed: 38905181
DOI: 10.1371/journal.pone.0304401 -
World Journal of Urology Jun 2024Current potential living kidney donor's assessment includes functional and anatomical evaluation. Scintigraphy is recommended in some cases and some centers include this...
BACKGROUND
Current potential living kidney donor's assessment includes functional and anatomical evaluation. Scintigraphy is recommended in some cases and some centers include this test in the donor's protocol. Recent studies advocate for the avoidance of this test as CT or MRI volumetry showed to accurately assess donor's renal function.
OBJECTIVE
To summarize scientific evidence on image tests for pre-donation and/or post-nephrectomy renal function evaluation.
EVIDENCE ACQUISITION
This review followed the guidelines set by the European Association of Urology and adhered to PRISMA 2020 recommendations. The protocol was registered in PROSPERO on 10th December 2022 (ID: CRD42022379273).
EVIDENCE SYNTHESIS
Twenty-one studies met the inclusion criteria after thorough screening and eligibility assessment. According to QUADAS-2, patient selection and flow/timing domains showed a predominant low risk of bias. The correlation between split renal function (SRF) using CT and scintigraphy varied from weak (r = 0.21) to remarkably strong (r = 0.949). Bland-Altman agreement demonstrated moderate to excellent results, with mean differences ranging from -0.06% to 1.76%. The correlation between split renal volume (CT) and estimated glomerular filtration rate (eGFR) at 6 months or 1 year after nephrectomy showed a moderate correlation, with coefficients ranging from 0.708 to 0.83. The correlation between SRF (MRI) and renal scintigraphy reported a moderate correlation, with correlation coefficients of 0.58 and 0.84. MRI and scintigraphy displayed a good agreement, with a 66% agreement observed and mean differences of ± 0.3%.
CONCLUSIONS
Despite study heterogeneity, MRI or CT-based renal volumetry appears promising compared to scintigraphy, with favorable correlations and agreement.
Topics: Humans; Living Donors; Magnetic Resonance Imaging; Tomography, X-Ray Computed; Radionuclide Imaging; Kidney Transplantation; Nephrectomy; Kidney; Kidney Function Tests; Tissue and Organ Harvesting
PubMed: 38904679
DOI: 10.1007/s00345-024-05024-y -
Frontiers in Neuroanatomy 2024Literature suggests a common pathophysiological ground between carotid atherosclerosis (CAS) and white matter alterations in the brain. However, the association between...
INTRODUCTION
Literature suggests a common pathophysiological ground between carotid atherosclerosis (CAS) and white matter alterations in the brain. However, the association between carotid intima-media thickness (CIMT) and white matter hyperintensities (WMH) has not been conclusively reported. The current systematic review explores and reports the relationship between CIMT and WMH among asymptomatic/non-stroke adults.
METHODS
A recent literature search on PubMed, SCOPUS, and Web of Science databases was conducted in compliance with the PRISMA protocol. The pre-defined Population-Intervention-Comparison-Outcome-Study (PICOS) criteria included observational studies investigating the CIMT-WMH association among non-stroke adults undergoing magnetic resonance imaging and carotid ultrasound.
RESULTS
Out of 255 potential results, 32 studies were critically assessed for selection, and finally, 10 articles were included, comprising 5,116 patients (females = 60.2%; males = 39.8%) aged between 36-71 years. The included studies earned high quality ratings (6-9) based on the Newcastle-Ottawa-Scale criteria. Qualitative synthesis showed a significantly parallel relationship between increased CIMT and greater WMH burden in 50% of the studies. In addition, significant risk factors related to the CIMT-WMH association included older age, hypertension, depression, migraine, Hispanic ethnicity, and apolipoprotein E (ɛ4) in postmenopausal women.
CONCLUSION
Overall, the cumulative evidence showed a consistent CIMT-WMH association in asymptomatic middle-aged and older non-stroke adults, indicating that CAS may contribute to the progression of pathologically hyperintense white matter in the brain. However, further research is warranted to infer the plausible relationship between CIMT and WMH in the absence of stroke.
PubMed: 38903057
DOI: 10.3389/fnana.2024.1394766 -
Journal of Orthopaedic Surgery and... Jun 2024A systematic review and meta-analysis. (Meta-Analysis)
Meta-Analysis Comparative Study
Accuracy and postoperative assessment of robot-assisted placement of pedicle screws during scoliosis surgery compared with conventional freehand technique: a systematic review and meta-analysis.
STUDY DESIGN
A systematic review and meta-analysis.
BACKGROUND
The complexity of human anatomical structures and the variability of vertebral body structures in patients with scoliosis pose challenges in pedicle screw placement during spinal deformity correction surgery. Through technological advancements, robots have been introduced in spinal surgery to assist with pedicle screw placement.
METHODS
A systematic search was conducted using PubMed, Cochrane, Embase, and CNKI databases and comparative studies assessing the accuracy and postoperative efficacy of pedicle screw placement using robotic assistance or freehand techniques in patients with scoliosis were included. The analysis evaluated the accuracy of screw placement, operative duration, intraoperative blood loss, length of postoperative hospital stay, and complications.
RESULTS
Seven studies comprising 584 patients were included in the meta-analysis, with 282 patients (48.3%) in the robot-assisted group and 320 (51.7%) in the freehand group. Robot-assisted placement showed significantly better clinically acceptable screw placement results compared with freehand placement (odds ratio [OR]: 2.61, 95% confidence interval [CI]: 1.75-3.91, P < 0.0001). However, there were no statistically significant differences in achieving "perfect" screw placement between the two groups (OR: 1.52, 95% CI: 0.95-2.46, P = 0.08). The robot-assisted group had longer operation durations (mean deviation [MD]: 43.64, 95% CI: 22.25-64.74, P < 0.0001) but shorter postoperative hospital stays (MD: - 1.12, 95% CI: - 2.15 to - 0.08, P = 0.03) than the freehand group. There were no significant differences in overall complication rates or intraoperative blood loss between the two groups. There was no significant difference in Cobb Angle between the two groups before and after operation.
CONCLUSION
Robot-assisted pedicle screw placement offers higher accuracy and shorter hospital stay than freehand placement in scoliosis surgery; although the robotics approach is associated with longer operative durations, similar complication rates and intraoperative blood loss.
Topics: Scoliosis; Humans; Pedicle Screws; Robotic Surgical Procedures; Length of Stay; Postoperative Complications; Spinal Fusion; Blood Loss, Surgical; Operative Time; Treatment Outcome; Postoperative Period
PubMed: 38902785
DOI: 10.1186/s13018-024-04848-z -
Neuroradiology Jun 2024Meningioma is the most common intracranial tumor, graded on pathology using WHO criteria to predict tumor course and treatment. However, pathological grading via biopsy...
PURPOSE
Meningioma is the most common intracranial tumor, graded on pathology using WHO criteria to predict tumor course and treatment. However, pathological grading via biopsy may not be possible in cases with poor surgical access due to tumor location. Therefore, our systematic review aims to evaluate whether diagnostic imaging features can differentiate high grade (HG) from low grade (LG) meningiomas as an alternative to pathological grading.
METHODS
Three databases were searched for primary studies that either use routine magnetic resonance imaging (MRI) or computed tomography (CT) to assess pathologically WHO-graded meningiomas. Two investigators independently screened and extracted data from included studies.
RESULTS
24 studies met our inclusion criteria with 12 significant (p < 0.05) CT and MRI features identified for differentiating HG from LG meningiomas. Cystic changes in the tumor had the highest specificity (93.4%) and irregular tumor-brain interface had the highest positive predictive value (65.0%). Mass effect had the highest sensitivity (81.0%) and negative predictive value (90.7%) of all imaging features. Imaging feature with the highest accuracy for identifying HG disease was irregular tumor-brain interface (79.7%). Irregular tumor-brain interface and heterogenous tumor enhancement had the highest AUC values of 0.788 and 0.703, respectively.
CONCLUSION
Our systematic review highlight imaging features that can help differentiate HG from LG meningiomas.
PubMed: 38902484
DOI: 10.1007/s00234-024-03404-0 -
The Journal of International Medical... Jun 2024Bizarre parosteal osteochondromatous proliferation (BPOP), also termed Nora lesion, is a rare, benign tumor most often located in the hands and feet. We herein present...
Bizarre parosteal osteochondromatous proliferation (BPOP), also termed Nora lesion, is a rare, benign tumor most often located in the hands and feet. We herein present the second reported case of BPOP affecting the spine, an uncommon location. One year after surgical excision, the patient was pain-free and showed no evidence of recurrence. We reviewed a total of 323 cases of BPOP among 101 articles, providing the first systematic update on the latest knowledge of BPOP. The age of patients with BPOP ranges from 3 months to 87 years, peaking in the second and third decades of life. The hands are the most common location of BPOP (58.39%), followed by the feet (20.81%). Imaging features play a key role in the diagnosis of BPOP, but histopathologic diagnosis remains the gold standard. Differential diagnosis of BPOP should be based on the epidemiologic and clinical features as well as clinical examination findings. Surgical resection is the most extensively used treatment for BPOP. Recurrence is common (37.44%) and can be treated with re-excision. This article can deepen our understanding of BPOP and will be helpful for the diagnosis and treatment of BPOP in clinical practice.
Topics: Humans; Osteochondroma; Male; Female; Adult; Spinal Neoplasms; Magnetic Resonance Imaging; Middle Aged; Diagnosis, Differential
PubMed: 38901838
DOI: 10.1177/03000605241259752 -
International Journal of Medical... Jun 2024The surge in emergency head CT imaging and artificial intelligence (AI) advancements, especially deep learning (DL) and convolutional neural networks (CNN), have... (Review)
Review
BACKGROUND
The surge in emergency head CT imaging and artificial intelligence (AI) advancements, especially deep learning (DL) and convolutional neural networks (CNN), have accelerated the development of computer-aided diagnosis (CADx) for emergency imaging. External validation assesses model generalizability, providing preliminary evidence of clinical potential.
OBJECTIVES
This study systematically reviews externally validated CNN-CADx models for emergency head CT scans, critically appraises diagnostic test accuracy (DTA), and assesses adherence to reporting guidelines.
METHODS
Studies comparing CNN-CADx model performance to reference standard were eligible. The review was registered in PROSPERO (CRD42023411641) and conducted on Medline, Embase, EBM-Reviews and Web of Science following PRISMA-DTA guideline. DTA reporting were systematically extracted and appraised using standardised checklists (STARD, CHARMS, CLAIM, TRIPOD, PROBAST, QUADAS-2).
RESULTS
Six of 5636 identified studies were eligible. The common target condition was intracranial haemorrhage (ICH), and intended workflow roles auxiliary to experts. Due to methodological and clinical between-study variation, meta-analysis was inappropriate. The scan-level sensitivity exceeded 90 % in 5/6 studies, while specificities ranged from 58,0-97,7 %. The SROC 95 % predictive region was markedly broader than the confidence region, ranging above 50 % sensitivity and 20 % specificity. All studies had unclear or high risk of bias and concern for applicability (QUADAS-2, PROBAST), and reporting adherence was below 50 % in 20 of 32 TRIPOD items.
CONCLUSION
0.01 % of identified studies met the eligibility criteria. The evidence on the DTA of CNN-CADx models for emergency head CT scans remains limited in the scope of this review, as the reviewed studies were scarce, inapt for meta-analysis and undermined by inadequate methodological conduct and reporting. Properly conducted, external validation remains preliminary for evaluating the clinical potential of AI-CADx models, but prospective and pragmatic clinical validation in comparative trials remains most crucial. In conclusion, future AI-CADx research processes should be methodologically standardized and reported in a clinically meaningful way to avoid research waste.
PubMed: 38901270
DOI: 10.1016/j.ijmedinf.2024.105523 -
Radiography (London, England : 1995) Jun 2024Delivering 24 h healthcare requires rotational shift work from doctors and the medical imaging team, while contributing to safe and timely care of patients. Additional... (Review)
Review
INTRODUCTION
Delivering 24 h healthcare requires rotational shift work from doctors and the medical imaging team, while contributing to safe and timely care of patients. Additional service pressure and staff shortfall leads to workload pressures, adjusted shift patterns and risk of burnout. Evidence should be sought to the effects of this work on staff.
METHODS
This systematic review followed PRISMA reporting guidelines, using a convergent mixed methods approach according to Guidance from Joanna Briggs International. Quantitative trends and results were qualified in order to thematically analyse in conjunction with qualitative data and discussed together in context. Following initial searching, returned articles were screened by title and abstract. A team of 3 reviewers undertook blinded critical appraisal of those suitable, with quality assurance from a 4th team member. Papers passing a threshold of 75% on JBI appraisal tools were accepted for synthesis. Data extraction of appropriate articles retrieved was undertaken in parallel.
RESULTS
Following screening and critical appraisal, 13 studies were returned focusing exclusively on Non Consultant Doctors. No studies investigated diagnostic radiographers. 85% (n = 11) reported negative association between shift work and the three themes of sleep/fatigue, burnout and wellbeing: including after the introduction of shift pattern control or adjusted shift patterns. The remainder showed no change, or any improvement nullified by countermeasures to maintain service delivery.
CONCLUSION
Current working practices and shift plans in the target population showed detrimental effects on the participants - this can be suggested that Diagnostic Radiographers may suffer fatigue, burnout and poor mental health from stretched shift working patterns.
IMPLICATIONS FOR PRACTICE
Further study into the effects of shift work on Diagnostic Radiographers and other allied health professionals is indicated - relating to the above themes in the context of errors and patient safety. Additional research into Non Consultant Doctors, shift work effects and the context of wider service delivery required; with suitable interventions and education to maximise understanding of legal working practices, monitoring and self-management of symptoms.
PubMed: 38901073
DOI: 10.1016/j.radi.2024.05.016 -
Nuclear Medicine Communications Jun 2024The aim of this study was to quantify the diagnostic value of dual-tracer PET/computed tomography (CT) with 11C-acetate and fluorodeoxyglucose (FDG) in per-lesion and...
The aim of this study was to quantify the diagnostic value of dual-tracer PET/computed tomography (CT) with 11C-acetate and fluorodeoxyglucose (FDG) in per-lesion and per-patient and its effect on clinical decision-making for choosing the most appropriate management. The study protocol is registered a priori at https://osf.io/rvm75/. PubMed, Web of Science, Embase, and Cochrane Library were searched for relevant studies until 1 June 2023. Studies regarding the review question were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to assess bias risk. Per-lesion and per-patient diagnostic performance were calculated for: (1) 11C-acetate alone; (2) FDG alone; and (3) dual tracer of 11C-acetate and FDG. A direct comparison of these three combinations was made. The possible sources of statistical heterogeneity were also examined. We also calculated the percentage change in clinical decision-making when dual-tracer PET/CT was added to conventional imaging routinely used for metastatic evaluation (CT/MRI). Grading of Recommendations, Assessment, Development, and Evaluations tool was used to evaluate the certainty of evidence. Eight studies including 521 patients and 672 metastatic lesions were included. Dual-tracer PET/CT had a per-lesion sensitivity of 96.3% [95% confidence interval (CI), 91.8-98.4%] and per-patient sensitivity of 95.5% (95% CI, 89.1-98.2%) which were highly superior to either of tracers alone. Per-patient specificity was 98.5% (84.1-99.9%) which was similar to either of tracers alone. Overall, 9.3% (95% CI, 4.7-13.9%) of the patients had their management beneficially altered by adding dual-tracer PET/CT to their conventional CT/MRI results. Dual-tracer PET/CT substantially outperforms single-tracer methods in detecting extrahepatic hepatocellular carcinoma metastases, evidencing its reliability and significant role in refining clinical management strategies based on robust diagnostic performance.
PubMed: 38899958
DOI: 10.1097/MNM.0000000000001870