Annals of Vascular Surgery May 2024The early postoperative benefits of endovascular aneurysm repair (EVAR) have been well established but questions remain regarding its durability at mid-term and...
Five-Year Results for Abdominal Aortic Aneurysm Repair with the GORE® EXCLUDER® Device: Insights from the Gore Global Registry for Endovascular Aortic Treatment (GREAT).
BACKGROUND
The early postoperative benefits of endovascular aneurysm repair (EVAR) have been well established but questions remain regarding its durability at mid-term and long-term time points. Long-term results in real-world use of EVAR outside of randomized trial data are limited. This study used the Global Registry for Endovascular Aortic Treatment registry to explore the 5-year outcomes with the GORE EXCLUDER device in real-world clinical circumstances.
METHODS
All patients within the Global Registry for Endovascular Aortic Treatment registry who underwent an infrarenal abdominal aortic aneurysm repair with the GORE EXCLUDER device were included in this study. Baseline characteristics and demographic information of the cohort were collected. End points included mortality (all-cause and aneurysm-related), serious endoleaks, aneurysm sac diameter, endograft integrity (fracture, compression, migration), post-EVAR aortic rupture, device-related reintervention, conversion to open repair, graft explantation, and major adverse cardiovascular events.
RESULTS
A total of 3,216 patients were included in this analysis. The cohort reflected a significantly comorbid population with 46% of patients reaching a Charlson Comorbidity Index score of ≥5. Follow-up at 5 years was 60% of eligible participants. The freedom from aortic-related mortality was at 98.8% and overall survival was 71.2%. Postoperative major adverse cardiovascular events occurred in 49 (1.5%) patients. Device-related intervention through 5 years was 7.2% and the overall serious endoleak rate was 6.8%. Less than 1% of patients required an open conversion/revision and aortic rupture following device placement occurred in 15 (0.5%) patients. Aneurysm sac regression was achieved in 58.1% of patients at 5 years, and stability/absence of growth was observed in 83.6% at 5 years.
CONCLUSIONS
This study supports the durability of the GORE EXCLUDER device through 5 years with negligible incidence of graft integrity compromise and low aortic/device-related reintervention rates. Furthermore, the efficacy of the device is highlighted with low aortic-related mortality and high sac regression/stability diameter through 5 years.
PubMed: 38815908
DOI: 10.1016/j.avsg.2024.03.016 -
Journal of Vascular Surgery Cases and... Aug 2024
PubMed: 38812727
DOI: 10.1016/j.jvscit.2024.101501 -
Annals of Vascular Surgery May 2024Endovascular aortic repair (EVAR) has become the standard of care for patients with infrarenal aortic aneurysms over the last 2 decades. Endograft technology and...
BACKGROUND
Endovascular aortic repair (EVAR) has become the standard of care for patients with infrarenal aortic aneurysms over the last 2 decades. Endograft technology and treatment of complications like endoleaks, graft migration, or graft occlusion developed over time. However, sometimes open surgical conversion maybe required. Our aim was to analyze the indications, the technical aspects and outcomes in patients who underwent open conversion after EVAR with different types and generations of endografts.
METHODS
This retrospective single-center study reviewed all patients who underwent EVAR from 2004 to 2020. Open surgical conversions >1 month post EVAR were identified. Conversions for graft infection were excluded. Indications for conversion and operative technique were analyzed. Primary endpoint of the study was 30-day mortality. Secondary endpoints were re-interventions and follow-up mortality.
RESULTS
During 2004 and 2020, 443 consecutive EVARs were performed, and 28 patients required open surgical conversion, with an additional 3 referred from other hospitals (N = 31). The median age was 75 (range 58-93); 94% were male. Conversion was performed after a median time of 55 months (range 16-209). Twenty patients underwent elective and 11 emergency conversion. Indications for open conversion were graft migration, respectively, disease progression with endoleak type Ia and/or Ib in 52% (16/31) and sac expansion due to endoleak type II in 26% (8/31). Of the 31 patients, 17 (55%) had at least one previous endovascular re-intervention. All patients met the device-specific instructions for use for each implanted endograft. In-hospital intervention rate was 16% (5/31). Thirty-day mortality rate was 3% (1/31) with one patient died due to multiorgan failure after rupture with complete endograft replacement. Five patients (16%) died during follow-up. Mid-term follow-up was 47.5 months (range 24-203) with estimated cumulative survival rates of 97%, 89%, and 84%, at 1, 3, and 5 years, respectively.
CONCLUSIONS
Late open conversion remains a valuable treatment option and can be performed safely in elective and emergency setting with a low early mortality. Lifelong surveillance and prompt intervention when necessary are essential in ensuring optimal outcomes after EVAR and preventing the need for emergent conversions.
PubMed: 38810725
DOI: 10.1016/j.avsg.2024.02.028 -
British Journal of Cardiac Nursing Oct 2023Abdominal aortic aneurysm (AAA) is a condition in which the abdominal aorta becomes enlarged, posing a risk of rupture and life-threatening haemorrhage. Abdominal aortic...
Abdominal aortic aneurysm (AAA) is a condition in which the abdominal aorta becomes enlarged, posing a risk of rupture and life-threatening haemorrhage. Abdominal aortic aneurysm accounts for a substantial number of fatalities worldwide, with mortality rates of up to 80 percent. Abdominal aortic aneurysms are often asymptomatic and are frequently discovered incidentally during tests for unrelated conditions. Surgery is required for aneurysms exceeding 5.5cm in men and 5cm in women, but post-surgical complications such as intra-abdominal adhesions, limb ischaemia and renal failure are common. There is some evidence showing that exercise, including prehabilitation, may be effective in improving patient outcomes post-surgery. However, there is a dearth of literature that has synthesised existing evidence related to the effectiveness of prehabilitation on patient outcomes post-surgery, and which has expanded upon its implications for clinical practise. This commentary aims to critically appraise the most recent Cochrane review in this area, and expand upon these findings to inform clinical practice.
PubMed: 38808305
DOI: 10.12968/bjca.2023.0078 -
European Heart Journal. Case Reports May 2024
Branch retinal artery occlusion with non-obstructive general angioscopy confirmed puff-chandelier rupture releasing cholesterol crystals in the aortic arch: a case report.
PubMed: 38807941
DOI: 10.1093/ehjcr/ytae238 -
European Journal of Vascular and... Apr 2024Open abdomen therapy (OAT) is commonly used to prevent or treat abdominal compartment syndrome (ACS) in patients with ruptured abdominal aortic aneurysms (rAAAs). This... (Observational Study)
Observational Study
Increasing Use of Prophylactic Open Abdomen Therapy With Vacuum Assisted Wound Closure and Mesh Mediated Fascial Traction After Repair of Ruptured Abdominal Aortic Aneurysm.
OBJECTIVE
Open abdomen therapy (OAT) is commonly used to prevent or treat abdominal compartment syndrome (ACS) in patients with ruptured abdominal aortic aneurysms (rAAAs). This study aimed to evaluate the incidence, treatment, and outcomes of OAT after rAAA from 2006 to 2021. Investigating data on resuscitation fluid, weight gain, and cumulative fluid balance could provide a more systematic approach to determining the timing of safe abdominal closure.
METHODS
This was a single centre observational cohort study. The study included all patients treated for rAAA followed by OAT from October 2006 to December 2021.
RESULTS
Seventy-two of the 244 patients who underwent surgery for rAAA received OAT. The mean age was 72 ± 7.85 years, and most were male (n = 61, 85%). The most frequent comorbidities were cardiac disease (n = 31, 43%) and hypertension (n = 31, 43%). Fifty-two patients (72%) received prophylactic OAT, and 20 received OAT for ACS (28%). There was a 25% mortality rate in the prophylactic OAT group compared with the 50% mortality in those who received OAT for ACS (p = .042). The 58 (81%) patients who survived until closure had a median of 12 (interquartile range [IQR] 9, 16.5) days of OAT and 5 (IQR 4, 7) dressing changes. There was one case of colocutaneous fistula and two cases of graft infection. All 58 patients underwent successful abdominal closure, with 55 (95%) undergoing delayed primary closure. In hospital survival was 85%. Treatment trends over time showed the increased use of prophylactic OAT (p ≤ .001) and fewer ACS cases (p = .03) assessed by Fisher's exact test. In multivariable regression analysis fluid overload and weight reduction predicted 26% of variability in time to closure.
CONCLUSION
Prophylactic OAT after rAAA can be performed safely, with a high rate of delayed primary closure even after long term treatment.
Topics: Humans; Aortic Aneurysm, Abdominal; Male; Aged; Female; Negative-Pressure Wound Therapy; Aortic Rupture; Intra-Abdominal Hypertension; Surgical Mesh; Aged, 80 and over; Treatment Outcome; Retrospective Studies; Traction; Time Factors; Middle Aged; Open Abdomen Techniques; Risk Factors; Abdominal Wound Closure Techniques; Fasciotomy; Postoperative Complications
PubMed: 38805011
DOI: 10.1016/j.ejvs.2023.10.032 -
Cureus Apr 2024We sought to determine whether there is a relationship between the fluoroscopic working angle used to achieve a co-planar view during the deployment of the prosthesis...
BACKGROUND
We sought to determine whether there is a relationship between the fluoroscopic working angle used to achieve a co-planar view during the deployment of the prosthesis during transcatheter aortic valve implantation (TAVI) and rates of complications, including paravalvular leaks, complete heart block, annular rupture, stroke, valve embolization, discharge to a skilled nursing facility and death within thirty days.
METHODS
All patients undergoing TAVI at our institution from 2015 to 2022 were retrospectively analyzed. Images were reviewed to determine the fluoroscopic working angle during deployment, and medical records were used to determine the incidence and type of complication. A multilayer perceptron was employed to evaluate the predictive ability of the fluoroscopic working angle during deployment on complications of one-day and 30-day paravalvular leak, 30-day mortality, the need for a new pacemaker, discharge to a skilled nursing facility, stroke and the requirement for emergency intervention.
RESULTS
Eight hundred and thirty-four patients were included in the study. Fluoroscopic working angle had excellent predictive value for stroke (area under the receiver operating characteristic curve (AUROC) of 0.812), one-day (AUROC 0.850), and 30-day paravalvular leak (AUROC 0.801). However, feature importance and scaled weighting analysis indicated that only a working angle in the left anterior oblique/cranial quadrant was informative for the development of an outcome of interest specific to a working angle quadrant (30-day paravalvular leak).
CONCLUSION
Fluoroscopic working angle may be a useful way to further refine well-established risk calculi during TAVI.
PubMed: 38803728
DOI: 10.7759/cureus.59144 -
Cureus Apr 2024Abdominal aortic aneurysm, characterized by a persistent dilation exceeding 3 cm or 50% of the aortic diameter, poses a substantial risk, particularly in males over 65....
Abdominal aortic aneurysm, characterized by a persistent dilation exceeding 3 cm or 50% of the aortic diameter, poses a substantial risk, particularly in males over 65. Despite its potentially asymptomatic nature, early detection is imperative due to the elevated mortality rates, reaching 90% following rupture. The presented case involves a 60-year-old male with progressively worsening abdominal pain, a history of cardiovascular disease, hypertension, and smoking. Initial examinations were inconclusive, requiring advanced imaging that revealed a large aneurysmal dilation. Therapeutic measures included endovascular aneurysm repair (EVAR), highlighting the significance of timely intervention. Despite elective surgery risks, mortality rates decrease significantly when the aneurysm diameter surpasses 43 mm. This report stresses the need for primary care physicians to conduct thorough screenings, recognize risk factors, and facilitate prompt referrals for advanced imaging. The case's pivotal lesson lies in the comprehensive management of abdominal aortic aneurysm, showcasing the potential for life-saving interventions and the critical role of early detection in mitigating the severe consequences associated with its rupture.
PubMed: 38800210
DOI: 10.7759/cureus.58894 -
FASEB Journal : Official Publication of... May 2024Distinguishing quiescent from rupture-prone atherosclerotic lesions has significant translational and clinical implications. Electrochemical impedance spectroscopy (EIS)...
Distinguishing quiescent from rupture-prone atherosclerotic lesions has significant translational and clinical implications. Electrochemical impedance spectroscopy (EIS) characterizes biological tissues by assessing impedance and phase delay responses to alternating current at multiple frequencies. We evaluated invasive 6-point stretchable EIS sensors over a spectrum of experimental atherosclerosis and compared results with intravascular ultrasound (IVUS), molecular positron emission tomography (PET) imaging, and histology. Male New Zealand White rabbits (n = 16) were placed on a high-fat diet, with or without endothelial denudation via balloon injury of the infrarenal abdominal aorta. Rabbits underwent in vivo micro-PET imaging of the abdominal aorta with Ga-DOTATATE, F-NaF, and F-FDG, followed by invasive interrogation via IVUS and EIS. Background signal-corrected values of impedance and phase delay were determined. Abdominal aortic samples were collected for histology. Analyses were performed blindly. EIS impedance was associated with markers of plaque activity including macrophage infiltration (r = .813, p = .008) and macrophage/smooth muscle cell (SMC) ratio (r = .813, p = .026). Moreover, EIS phase delay correlated with anatomic markers of plaque burden, namely intima/media ratio (r = .883, p = .004) and %stenosis (r = .901, p = .002), similar to IVUS. Ga-DOTATATE correlated with intimal macrophage infiltration (r = .861, p = .003) and macrophage/SMC ratio (r = .831, p = .021), F-NaF with SMC infiltration (r = -.842, p = .018), and F-FDG correlated with macrophage/SMC ratio (r = .787, p = .036). EIS with phase delay integrates key atherosclerosis features that otherwise require multiple complementary invasive and non-invasive imaging approaches to capture. These findings indicate the potential of invasive EIS to comprehensively evaluate human coronary artery disease.
Topics: Animals; Rabbits; Dielectric Spectroscopy; Male; Atherosclerosis; Aorta, Abdominal; Plaque, Atherosclerotic; Positron-Emission Tomography; Phenotype; Disease Models, Animal; Macrophages
PubMed: 38787606
DOI: 10.1096/fj.202302544RR -
Cardiology in Review May 2024Both types of aortic dissection (AD), Stanford type A and type B, can result in complications such as acute kidney injury (AKI) and aortic rupture. Renal complications...
Exploring Acute Kidney Injury Following Aortic Dissection: A Comprehensive Review of Machine Learning Models for Predicting Risk, Management Strategies, Complications, and Racial and Gender Disparities.
Both types of aortic dissection (AD), Stanford type A and type B, can result in complications such as acute kidney injury (AKI) and aortic rupture. Renal complications in AD arise from compromised renal perfusion affecting the renal arteries. Understanding the intricate connection between AD and AKI is crucial for navigating the complexities of tailored treatment and formulating specific management plans. Concerning machine learning models, in patients with type A aortic dissection, factors such as decreased platelet count on admission, increased D-dimer level, longer cardiopulmonary bypass duration, elevated white blood cell levels, the need for blood transfusion, longer aortic clamp time, extended surgery duration, advanced age, and an elevated body mass index were positively associated with the development of AKI. For the risk of AKI after type B aortic dissection, elevated Nt-pro brain natriuretic peptide, prolonged activated partial thromboplastin time, elevated admission systolic blood pressure, and a higher contrast agent requirement during operative repair were found to predict the risk. Male gender was associated with a higher risk of AKI, and nonwhite race was linked to a higher risk of AKI, a greater likelihood of requiring more urgent procedures, and lower levels of insurance coverage. The treatment of AKI following AD requires a multifaceted approach. Identifying and addressing the underlying cause, such as low blood pressure, renal artery involvement, or medication-induced injury, is crucial for effective management and preventing further kidney damage. Maintaining proper fluid balance is essential for improving renal perfusion, but careful monitoring is necessary to avoid complications. The evolving landscape of research, particularly in biomarkers and AI programs, reveals a promising role in predicting the risk for and managing AKI post-AD.
PubMed: 38785437
DOI: 10.1097/CRD.0000000000000717