-
Journal of Pharmacy & Bioallied Sciences Apr 2024Immediate implant placement into a fresh extraction socket has been developed as a consistent treatment, allowing for a reduction in the duration of time necessary for... (Review)
Review
BACKGROUND
Immediate implant placement into a fresh extraction socket has been developed as a consistent treatment, allowing for a reduction in the duration of time necessary for prosthetic rehabilitation. The study will evaluate the clinical and radiologic outcomes of implants placed immediately for a 10-year follow-up period.
AIM
The aim of this systematic review is to evaluate the durability of the immediate implant in periodontally compromised individual placement.
METHODS
Studies reporting clinical and radiologic implant outcomes from periodontally compromised individuals who were treated and followed periodontal and implant maintenance for ≥5 years were considered eligible for the review. Screening of the articles, data extraction, and quality assessment were conducted independently and in duplicate.
RESULTS
There were 99 papers, and of them, 55 were excluded after title/abstract assessment. The full texts of 28 potentially eligible publications were screened, but only seven studies met the inclusion criteria.
CONCLUSIONS
The study confirms that immediate implant therapy is safe, effective, and predictable for successful osseointegration and long-term functioning in periodontally compromised individuals, with minimal differences in clinical and radiographic outcomes.
PubMed: 38882765
DOI: 10.4103/jpbs.jpbs_1115_23 -
L-arginine loading porous PEEK promotes percutaneous tissue repair through macrophage orchestration.Bioactive Materials Oct 2024Infection and poor tissue repair are the key causes of percutaneous implantation failure. However, there is a lack of effective strategies to cope with due to its high...
Infection and poor tissue repair are the key causes of percutaneous implantation failure. However, there is a lack of effective strategies to cope with due to its high requirements of sterilization, soft tissue healing, and osseointegration. In this work, l-arginine (L-Arg) was loaded onto a sulfonated polyetheretherketone (PEEK) surface to solve this issue. Under the infection condition, nitric oxide (NO) and reactive oxygen species (ROS) are produced through catalyzing L-Arg by inducible nitric oxide synthase (iNOS) and thus play a role in bacteria sterilization. Under the tissue repair condition, L-Arg is catalyzed to ornithine by Arginase-1 (Arg-1), which promotes the proliferation and collagen secretion of L929 and rBMSCs. Notably, L-Arg loading samples could polarize macrophages to M1 and M2 in infection and tissue repair conditions, respectively. The results show that the L-Arg loading samples could enhance infected soft tissue sealing and bone regeneration. In summary, L-Arg loading sulfonated PEEK could polarize macrophage through metabolic reprogramming, providing multi-functions of antibacterial abilities, soft tissue repair, and bone regeneration, which gives a new idea to design percutaneous implantation materials.
PubMed: 38882001
DOI: 10.1016/j.bioactmat.2024.05.025 -
Journal of Dental Research, Dental... 2024Modifying the dental implant's surface texture enhances its biological response to the bone and implant‒tissue interface, resulting in the successful support of...
BACKGROUND
Modifying the dental implant's surface texture enhances its biological response to the bone and implant‒tissue interface, resulting in the successful support of forces. This study assessed the impact of sandblasting, sandblasting plus acid etching, Er,Cr:YSGG laser, and propolis implant surface treatments and occlusal load on the osseointegration of titanium dental implants in dogs.
METHODS
Seventy-two titanium dental implants with a diameter of 4 mm and a length of 10 mm were divided into four groups according to implant surface modifications (n=18 for each group): group A: sandblasting plus acid etching, group B: sandblasting with Al O, group C: Er,Cr:YSGG laser, group D: propolis coating. Twenty-four local breed male dogs were used. Premolar teeth (P1, P2, and P3) were extracted on the left side of the mandible, and after 12 weeks of bone healing, implants were unilaterally installed. The osseointegration at three study times from implant installation (14, 90, and 180 days) was evaluated. The dog jaws were scanned using an intraoral scanner for the virtual design of screw-retained three-unit crowns after 90 days of osseointegration. Final radiographs were taken before the animals were sacrificed at 14, 90, and 180 days, and the histological analysis was performed.
RESULTS
Radiographic analysis showed new bone formation (NBF) along and in contact with the implant surface of the treated groups. The histological analysis after 14 days in groups A and B revealed a uniform and ongoing pattern of bone growth and many osteoblasts with few osteocytes within lacunae in new bone trabeculae. Group C showed an increase in the number of osteoblasts lining thin bone trabeculae. Group D showed a generative power concerning bone. At 90 days, there was increased bone ingrowth, and the new bone matured in all the treated implant groups. At 180 days, dense mature bone apposition was in direct contact with delayed-loaded implant surfaces.
CONCLUSION
A radiographic examination revealed that surface modification significantly impacted osseointegration, with a strong bond between the implant surface and the surrounding bone. The histological sections at the 14-day interval revealed obvious bone remodeling activity, especially in sandblasting plus acid etching and sandblasting-modified implant surface groups. At the 90-day interval, bone ingrowth had increased, and the new bone became mature, especially in sandblasting and propolis surface modification groups. After 180 days of the delayed-loaded implant osseointegration, differences were observed between different implant-treated groups with a remarkable remodeling of the bone, especially in the propolis coating group.
PubMed: 38881643
DOI: 10.34172/joddd.41009 -
Bone Jun 2024We evaluated the potential of sclerostin antibody (SclAb) therapy to enhance osseointegration of dental and orthopaedic implants in a mouse model (Brtl/+) mimicking...
We evaluated the potential of sclerostin antibody (SclAb) therapy to enhance osseointegration of dental and orthopaedic implants in a mouse model (Brtl/+) mimicking moderate to severe Osteogenesis Imperfecta (OI). To address the challenges in achieving stable implant integration in compromised bone conditions, our aim was to determine the effectiveness of sclerostin antibody (SclAb) at improving bone-to-implant contact and implant fixation strength. Utilizing a combination of micro-computed tomography, mechanical push-in testing, immunohistochemistry, and Western blot analysis, we observed that SclAb treatment significantly enhances bone volume fraction (BV/TV) and bone-implant contact (BIC) in Brtl/+ mice, suggesting a normalization of bone structure toward WT levels. Despite variations in implant survival rates between the maxilla and tibia, SclAb treatment consistently improved implant stability and resistance to mechanical forces, highlighting its potential to overcome the inherent challenges of OI in dental and orthopaedic implant integration. These results suggest that SclAb could be a valuable therapeutic approach for enhancing implant success in compromised bone conditions.
PubMed: 38876270
DOI: 10.1016/j.bone.2024.117167 -
Nanoscale Jun 2024Titanium-based orthopedic implants are gaining popularity in recent years due to their excellent biocompatibility, superior corrosion resistance and lightweight...
Titanium-based orthopedic implants are gaining popularity in recent years due to their excellent biocompatibility, superior corrosion resistance and lightweight properties. However, these implants often fail to perform effectively due to poor osseointegration. Nanosurface modification approaches may help to resolve this problem. In this work, TiO nanotube (NT) arrays were fabricated on commercially available pure titanium (Ti) surfaces by anodization and annealing. Then, zinc (Zn) and strontium (Sr), important for cell signaling, were doped on the NT surface by hydrothermal treatment. This very simple method of Zn and Sr doping takes less time and energy compared to other complicated techniques. Different surface characterization tools such as scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS), static water contact angle, X-ray diffraction (XRD) and nanoindentation techniques were used to evaluate the modified surfaces. Then, adipose derived stem cells (ADSCs) were cultured with the surfaces to evaluate cell adhesion, proliferation, and growth on the surfaces. After that, the cells were differentiated towards osteogenic lineage to evaluate alkaline phosphatase (ALP) activity, osteocalcin expression, and calcium phosphate mineralization. Results indicate that NT surfaces doped with Zn and Sr had significantly enhanced ADSC adhesion, proliferation, growth, and osteogenic differentiation compared to an unmodified surface, thus confirming the enhanced performance of these surfaces.
PubMed: 38874593
DOI: 10.1039/d4nr01123f -
Cureus May 2024Prosthodontics, which is removable and fixed, is the branch dealing with the replacement of missing teeth. Implant therapy is the popular treatment modality and... (Review)
Review
Prosthodontics, which is removable and fixed, is the branch dealing with the replacement of missing teeth. Implant therapy is the popular treatment modality and commonly preferred treatment option by many patients and clinicians for missing teeth in recent years. Primary implant stability (PIS) is one of the crucial factors for osseointegration. It has been considered a crucial factor in the success of implants. Moreover, several factors influence PIS. On the other hand, both secondary implant stability and osseointegration are influenced by the PIS. Bone density, bone volume, bone-to-implant contact, and other factors that enhance or degrade the primary stability. Certain host sites such as the maxillary posterior region demand more dense bone to achieve desired results as they are the low-density areas of the jaw. So, a new promising and growing innovative concept of osseodensification (OD) offers a great solution with multiple benefits and desirable results. This review article aims to enlighten the multiple benefits of OD technique and their mechanism of action.
PubMed: 38872641
DOI: 10.7759/cureus.60255 -
Clinical Oral Investigations Jun 2024Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols.
Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial : Bioactive implant surfaces in poor density bone.
OBJECTIVES
Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols.
MATERIALS AND METHODS
36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed.
RESULTS
The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 (p = 0.005) and T30-T45 (p = 0.012). Control group showed a significant decrease in ISQ at T30 (p = 0.01) and T45 (p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 (p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG.
CONCLUSIONS
The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).
Topics: Humans; Surface Properties; Male; Female; Bone Density; Torque; Dental Implants; Middle Aged; Dental Implantation, Endosseous; Dental Prosthesis Design; Adult; Treatment Outcome; Osseointegration
PubMed: 38872049
DOI: 10.1007/s00784-024-05747-7 -
Acta Biomaterialia Jun 2024To study in vivo the bioactivity of biodegradable magnesium implants and other possible biomaterials, we are proposing a previously unexplored application of PET-CT...
To study in vivo the bioactivity of biodegradable magnesium implants and other possible biomaterials, we are proposing a previously unexplored application of PET-CT imaging, using available tracers to follow soft tissue and bone remodelling and immune response in the presence of orthopaedic implants. Female Wistar rats received either implants (Ti6Al7Nb titanium or WE43 magnesium) or corresponding transcortical sham defects into the diaphyseal area of the femurs. Inflammatory response was followed with [F]FDG and osteogenesis with [F]NaF, over the period of 1.5 months after surgery. An additional pilot study with [Ga]NODAGA-RGD tracer specific to αβ integrin expression was performed to follow the angiogenesis for one month. [F]FDG tracer uptake peaked on day 3 before declining in all groups, with Mg and Ti groups exhibiting overall higher uptake compared to sham. This suggests increased cellular activity and tissue response in the presence of Mg during the initial weeks, with Ti showing a subsequent increase in tracer uptake on day 45, indicating a foreign body reaction. [F]NaF uptake demonstrated the superior osteogenic potential of Mg compared to Ti, with peak uptake on day 7 for all groups. [Ga]NODAGA-RGD pilot study revealed differences in tracer uptake trends between groups, particularly the prolonged expression of αβ integrin in the presence of implants. Based on the observed differences in the uptake trends of radiotracers depending on implant material, we suggest that PET-CT is a suitable modality for long-term in vivo assessment of orthopaedic biomaterial biocompatibility and underlying tissue reactions. STATEMENT OF SIGNIFICANCE: The study explores the novel use of positron emission tomography for the assessment of the influence that biomaterials have on the surrounding tissues. Previous related studies have mostly focused on material-related effects such as implant-associated infections or to follow the osseointegration in prosthetics, but the use of PET to evaluate the materials has not been reported before. The approach tests the feasibility of using repeated PET-CT imaging to follow the tissue response over time, potentially improving the methodology for adopting new biomaterials for clinical use.
PubMed: 38871201
DOI: 10.1016/j.actbio.2024.06.005 -
Cureus May 2024In the evolving field of orthopedic surgery, the integration of three-dimensional printing (3D printing) has emerged as a transformative technology, particularly in... (Review)
Review
In the evolving field of orthopedic surgery, the integration of three-dimensional printing (3D printing) has emerged as a transformative technology, particularly in addressing the rising incidence of degenerative joint diseases. The integration of 3D printing technology in hip arthroplasty offers substantial advantages throughout the surgical process. In preoperative planning, 3D models enable meticulous assessments, aiding in accurate implant selection and precise surgical strategies. Intraoperatively, the technology contributes to precise prosthesis design, reducing operation duration, X-ray exposures, and blood loss. Beyond surgery, 3D printing revolutionizes medical equipment production, imaging, and implant design, showcasing benefits such as enhanced osseointegration and reduced stress shielding with titanium cups. Challenges include a higher risk of postoperative infection due to the porous surfaces of 3D-printed implants, technical complexities in the printing process, and the need for skilled manpower. Despite these challenges, the evolving nature of 3D printing technologies underscores the importance of relying on existing orthopedic surgical practices while emphasizing the need for standardized guidelines to fully harness its potential in improving patient care.
PubMed: 38868274
DOI: 10.7759/cureus.60201 -
Cureus May 2024Long-term implant rehabilitation is still a problem. After about three months of implantation, the patient should go through rehabilitation to allow for...
Long-term implant rehabilitation is still a problem. After about three months of implantation, the patient should go through rehabilitation to allow for osseointegration. However, poor patient cooperation during lengthy treatments or patient neglect, especially during patient-intensive treatments, can lead to a range of issues that require distinct approaches to solve. A fixed prosthetic is currently the most sought-after course of treatment. Implant misplacement can be a concern, especially during the prosthetic stage. Following the appropriate protocols, one of which has been discussed in this report, makes it possible to achieve prosthetic outcomes for a number of difficult cases. In the case described in this report, resin-retained restoration was used as an alternative to an implant-supported prosthesis because of the non-optimal position of the implant at the time of the prosthetic phase, which was due to discontinuation of treatment on the part of the patient. The conservative preparation of abutment teeth and pontic covering the non-optimally placed implant gave the best outcome and satisfaction on the part of the patient.
PubMed: 38868237
DOI: 10.7759/cureus.60167