Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668 -
The Lancet. Global Health Jun 2024Early detection and diagnosis of acute rheumatic fever and rheumatic heart disease are key to preventing progression, and echocardiography has an important diagnostic... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Early detection and diagnosis of acute rheumatic fever and rheumatic heart disease are key to preventing progression, and echocardiography has an important diagnostic role. Standard echocardiography might not be feasible in high-prevalence regions due to its high cost, complexity, and time requirement. Handheld echocardiography might be an easy-to-use, low-cost alternative, but its performance in screening for and diagnosing acute rheumatic fever and rheumatic heart disease needs further investigation.
METHODS
In this systematic review and meta-analysis, we searched Embase, MEDLINE, LILACS, and Conference Proceedings Citation Index-Science up to Feb 9, 2024, for studies on the screening and diagnosis of acute rheumatic fever and rheumatic heart disease using handheld echocardiography (index test) or standard echocardiography or auscultation (reference tests) in high-prevalence areas. We included all studies with useable data in which the diagnostic performance of the index test was assessed against a reference test. Data on test accuracy in diagnosing rheumatic heart disease, acute rheumatic fever, or carditis with acute rheumatic fever (primary outcomes) were extracted from published articles or calculated, with authors contacted as necessary. Quality of evidence was appraised using GRADE and QUADAS-2 criteria. We summarised diagnostic accuracy statistics (including sensitivity and specificity) and estimated 95% CIs using a bivariate random-effects model (or univariate random-effects models for analyses including three or fewer studies). Area under the curve (AUC) was calculated from summary receiver operating characteristic curves. Heterogeneity was assessed by visual inspection of plots. This study was registered with PROSPERO (CRD42022344081).
FINDINGS
Out of 4868 records we identified 11 studies, and two additional reports, comprising 15 578 unique participants. Pooled data showed that handheld echocardiography had high sensitivity (0·87 [95% CI 0·76-0·93]), specificity (0·98 [0·71-1·00]), and overall high accuracy (AUC 0·94 [0·84-1·00]) for diagnosing rheumatic heart disease when compared with standard echocardiography (two studies; moderate certainty of evidence), with better performance for diagnosing definite compared with borderline rheumatic heart disease. High sensitivity (0·79 [0·73-0·84]), specificity (0·85 [0·80-0·89]), and overall accuracy (AUC 0·90 [0·85-0·94]) for screening rheumatic heart disease was observed when pooling data of handheld echocardiography versus standard echocardiography (seven studies; high certainty of evidence). Most studies had a low risk of bias overall. Some heterogeneity was observed for sensitivity and specificity across studies, possibly driven by differences in the prevalence and severity of rheumatic heart disease, and level of training or expertise of non-expert operators.
INTERPRETATION
Handheld echocardiography has a high accuracy and diagnostic performance when compared with standard echocardiography for diagnosing and screening of rheumatic heart disease in high-prevalence areas.
FUNDING
World Health Organization.
TRANSLATIONS
For the Chinese, French, Italian, Persian, Portuguese, Spanish and Urdu translations of the abstract see Supplementary Materials section.
Topics: Humans; Rheumatic Heart Disease; Echocardiography; Mass Screening; World Health Organization; Practice Guidelines as Topic; Sensitivity and Specificity
PubMed: 38762298
DOI: 10.1016/S2214-109X(24)00127-X -
Heliyon Apr 2024Confirming proper placement of an endotracheal tube (ETT) is important, as accidental misplacements may occur and lead to critical injuries, potentially leading to...
BACKGROUND
Confirming proper placement of an endotracheal tube (ETT) is important, as accidental misplacements may occur and lead to critical injuries, potentially leading to adverse outcomes. Multiple methods are available for determining the correct ETT placement in prehospital care.
OBJECTIVE
To assess the accuracy and reliability of the different methods used to confirm endotracheal intubation in prehospital settings.
METHODS
A comprehensive literature search was performed in the MEDLINE, EMBASE, Scopus, and Web of Science databases for studies that were published between 1-June-1992 and 12-June-2022 using a combination of predetermined search terms. Studies that met the inclusion criteria were included and assessed for risk of bias using "Risk of Bias in Non-randomized Studies of Intervention" tool.
RESULTS
Of the 1016 identified studies, nine met the inclusion criteria. Capnography and point-of-care ultrasound showed high sensitivity and specificity rates when applied to confirm ETT placement in prehospital care. Other methods including capnometry, colorimetric detectors, ODDs, and auscultation showed varied sensitivity and specificity. Patient comorbidities and device failure contributed to decreased accuracy rates in prehospital care. Capnography was less reliable in distinguishing between endotracheal intubation and right main stem intubation, which is known as a complication in out-of-hospital endotracheal intubation. Point-of-care ultrasound was more accurate and reliable in detecting oesophageal and endobronchial misplacements. ETCO monitors, i.e., capnometry and colorimetric detectors, were less reliable in patients with low perfusion states.
CONCLUSION
This systematic review showed that there is no single method with 100% accuracy in confirming the correct ETT placement and detecting the occurrence of accidental oesophageal or endobronchial misplacements in prehospital care. Further studies with a larger sample size are needed to assess the accuracy of multiple confirmatory methods in prehospital settings.
PubMed: 38586363
DOI: 10.1016/j.heliyon.2024.e28479 -
Canadian Journal of Kidney Health and... 2023Lung ultrasound is a noninvasive bedside technique that can accurately assess pulmonary congestion by evaluating extravascular lung water. This technique is expanding... (Review)
Review
PURPOSE OF REVIEW
Lung ultrasound is a noninvasive bedside technique that can accurately assess pulmonary congestion by evaluating extravascular lung water. This technique is expanding and is easily available. Our primary outcome was to compare the efficacy of volume status assessment by lung ultrasound with clinical evaluation, echocardiography, bioimpedance, or biomarkers. The secondary outcomes were all-cause mortality and cardiovascular events.
SOURCES OF INFORMATION
We conducted a MEDLINE literature search for observational and randomized studies with lung ultrasound in patients on maintenance dialysis.
METHODS
From a total of 2363 articles, we included 28 studies (25 observational and 3 randomized). The correlation coefficients were pooled for each variable of interest using the generic inverse variance method with a random effects model. Among the clinical parameters, New York Heart Association Functional Classification of Heart Failure status and lung auscultation showed the highest correlation with the number of B-lines on ultrasound, with a pooled correlation coefficient of .57 and .36, respectively. Among echocardiographic parameters, left ventricular ejection fraction and inferior vena cava index had the strongest correlation with the number of B-lines, with a pooled coefficient of .35 and .31, respectively. Three randomized studies compared a lung ultrasound-guided approach with standard of care on hard clinical endpoints. Although patients in the lung ultrasound group achieved better decongestion and blood pressure control, there was no difference between the 2 management strategies with respect to death from any cause or major adverse cardiovascular events.
KEY FINDINGS
Lung ultrasound may be considered for the identification of patients with subclinical volume overload. Trials did not show differences in clinically important outcomes. The number of studies was small and many were of suboptimal quality.
LIMITATIONS
The included studies were heterogeneous and of relatively limited quality.
PubMed: 38148768
DOI: 10.1177/20543581231217853 -
Bioengineering (Basel, Switzerland) Oct 2023Pulmonary auscultation is essential for detecting abnormal lung sounds during physical assessments, but its reliability depends on the operator. Machine learning (ML)... (Review)
Review
Pulmonary auscultation is essential for detecting abnormal lung sounds during physical assessments, but its reliability depends on the operator. Machine learning (ML) models offer an alternative by automatically classifying lung sounds. ML models require substantial data, and public databases aim to address this limitation. This systematic review compares characteristics, diagnostic accuracy, concerns, and data sources of existing models in the literature. Papers published from five major databases between 1990 and 2022 were assessed. Quality assessment was accomplished with a modified QUADAS-2 tool. The review encompassed 62 studies utilizing ML models and public-access databases for lung sound classification. Artificial neural networks (ANN) and support vector machines (SVM) were frequently employed in the ML classifiers. The accuracy ranged from 49.43% to 100% for discriminating abnormal sound types and 69.40% to 99.62% for disease class classification. Seventeen public databases were identified, with the ICBHI 2017 database being the most used (66%). The majority of studies exhibited a high risk of bias and concerns related to patient selection and reference standards. Summarizing, ML models can effectively classify abnormal lung sounds using publicly available data sources. Nevertheless, inconsistent reporting and methodologies pose limitations to advancing the field, and therefore, public databases should adhere to standardized recording and labeling procedures.
PubMed: 37892885
DOI: 10.3390/bioengineering10101155 -
Paediatric Respiratory Reviews Mar 2024Bronchiolitis is a leading cause of infant hospitalization, linked to respiratory syncytial virus (RSV) and rhinovirus (RV). Guidelines lack specific viral testing for... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Bronchiolitis is a leading cause of infant hospitalization, linked to respiratory syncytial virus (RSV) and rhinovirus (RV). Guidelines lack specific viral testing for bronchiolitis management. To establish effective management strategies, it is crucial to assess whether specific respiratory virus types are correlated with distinct examination features.
METHODS
Through a systematic search of three databases, 21 studies were qualitatively analyzed, with 18 used for meta-analysis. Various outcomes like wheezing on auscultation, fever, atopic traits, and infection severity were evaluated.
RESULTS
RSV-positive bronchiolitis was associated with a higher need for oxygen supplementation (OR 1.78, 95% CI 1.04-3.02) in 5 studies, while RV-positive bronchiolitis was more frequently linked to personal history of eczema (OR 0.60, 95% CI 0.41-0.88) in 6 studies. No significant differences were observed in the other outcomes examined.
CONCLUSIONS
Bronchiolitis caused by RSV or RV presents with similar clinical features. Despite the associations between RSV-positive bronchiolitis and need for oxygen supplementation, and RV-positive bronchiolitis and a history of eczema, our study shows that viral etiology of bronchiolitis cannot be determined solely based on clinical presentation. Tailored management strategies, informed by accurate viral testing, seem crucial in clinical practice for enhancing patient outcomes in severe bronchiolitis.
Topics: Infant; Humans; Bronchiolitis; Respiratory Syncytial Virus Infections; Respiratory Syncytial Virus, Human; Hospitalization; Rhinovirus; Eczema; Respiratory Sounds
PubMed: 37743159
DOI: 10.1016/j.prrv.2023.09.003 -
Cureus Jul 2023This systematic review, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, evaluates the effectiveness of... (Review)
Review
This systematic review, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, evaluates the effectiveness of simulation-based education in teaching cardiac auscultation. A team of researchers conducted a comprehensive, systematic search of the PubMed database from 2010 to 2021, focusing on cardiac auscultation, education, proficiency, and students. After rigorous filtering, a total of 14 articles, primarily involving medical students and residents, met the inclusion criteria. The articles were categorized based on their focus areas: diagnostic accuracy, knowledge acquisition, competency, and learner satisfaction. Findings suggest that the majority of the studies (86% or 12 out of 14) reported positive outcomes of using simulation for teaching cardiac auscultation, demonstrating improvements in the identified focus areas across diverse contexts. The review underscores the need for future research to further standardize simulation teaching practices, aiming to reduce costs, improve usability, and possibly incorporate multiple simulation approaches in a universal educational process. This approach could enhance outcomes across varied fields and learning styles.
PubMed: 37554623
DOI: 10.7759/cureus.41567 -
CJC Open May 2023Patients with obstruction to the left ventricular outflow tract from degenerative aortic stenosis (AS) usually do not become symptomatic until their disease becomes... (Review)
Review
BACKGROUND
Patients with obstruction to the left ventricular outflow tract from degenerative aortic stenosis (AS) usually do not become symptomatic until their disease becomes graded as severe. We sought to assess the accuracy of the physical examination for the diagnosis of AS of at least moderate severity.
METHODS
A systematic review and meta-analysis of case series and cohorts of patients who received a cardiovascular physical examination prior to receiving a left heart catheterization or an echocardiogram. PubMed, Ovid MEDLINE, the Cochrane Library, ClinicalTrials.gov, and Embase were searched with a date range from inception through December 10, 2021, without language restrictions.
RESULTS
Our systematic review yielded 7 observational studies with adequate data to perform a meta-analysis on 3 physical examination assessments. Auscultating a diminished second heart sound (likelihood ratio [LR] = 10.87, 95% confidence interval [CI], 3.94-30.12, < 0.05) and palpating a delayed carotid upstroke (LR = 9.04, 95% CI, 3.12-25.44, < 0.05) are useful for detecting AS of at least moderate severity. The absence of a systolic murmur radiating to the neck (LR = 0.11, 95% CI, 0.06-0.23, < 0.05) rules against AS of at least moderate severity.
CONCLUSIONS
Low-quality evidence from observational studies supports a diminished second heart sound and a delayed carotid upstroke as having moderate accuracy in diagnosing the presence of AS of at least moderate severity, whereas the absence of a murmur radiating to the neck is equally accurate in excluding this diagnosis.
PubMed: 37377515
DOI: 10.1016/j.cjco.2023.02.007 -
Heliyon Apr 2023Insertion of a double-lumen endotracheal tube (DLT) is the most commonly used method for one-lung ventilation (OLV). This meta-analysis was aimed at investigating the...
OBJECTIVES
Insertion of a double-lumen endotracheal tube (DLT) is the most commonly used method for one-lung ventilation (OLV). This meta-analysis was aimed at investigating the performance of lung ultrasound in assessing the DLT position in OLV.
METHODS
Electronic databases were searched for related trials from inception to October 2022. The primary outcome was the performance of ultrasound or clinical evaluation in confirming the correctness of the DLT position, using fiberoptic bronchoscopy or intraoperative direct visualization of lung collapse as the gold standard. The secondary outcome was the time required to confirm or adjust the DTL position.
RESULTS
Five randomized controlled trials and three observational studies involving 771 patients were included in the meta-analysis. The pooled sensitivity and specificity of ultrasound were 0.93 (95% confidence interval [CI]: 0.79-0.98) and 0.61 (95% CI: 0.41-0.77), respectively, while those of clinical evaluation were 0.93 (95% CI: 0.73-0.99) and 0.35 (95% CI: 0.25-0.47), respectively. The pooled procedure duration was 122.27 s (95% CI: 20.85-223.69) with ultrasound and 112.03 s (95% CI: 95.30-128.76) with clinical evaluation. The area under the curve for discriminating the DLT position was 0.86 (95% CI: 0.82-0.88) for ultrasound and 0.52 (95% CI: 0.48-0.57) for clinical evaluation.
CONCLUSIONS
Compared to clinical evaluation, ultrasound has a similar sensitivity but a better specificity for confirming the correctness of the DLT position. Ultrasound is an acceptable imaging tool for assessing DTL placement in OLV.
PubMed: 37128322
DOI: 10.1016/j.heliyon.2023.e15458 -
BMJ Open Mar 2023The objective of this study was to determine the diagnostic accuracy in detecting valvular heart disease (VHD) by heart auscultation, performed by medical doctors.
OBJECTIVE
The objective of this study was to determine the diagnostic accuracy in detecting valvular heart disease (VHD) by heart auscultation, performed by medical doctors.
DESIGN/METHODS
A systematic literature search for diagnostic studies comparing heart auscultation to echocardiography or angiography, to evaluate VHD in adults, was performed in MEDLINE (1947-November 2021) and EMBASE (1947-November 2021). Two reviewers screened all references by title and abstract, to select studies to be included. Disagreements were resolved by consensus meetings. Reference lists of included studies were also screened. The results are presented as a narrative synthesis, and risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2.
MAIN OUTCOME MEASURES
Sensitivity, specificity and likelihood ratios (LRs).
RESULTS
We found 23 articles meeting the inclusion criteria. Auscultation was compared with full echocardiography in 15 of the articles; pulsed Doppler was used as reference standard in 2 articles, while aortography and ventriculography was used in 5 articles. One article used point-of-care ultrasound. The articles were published from year 1967 to 2021. Sensitivity of auscultation ranged from 30% to 100%, and specificity ranged from 28% to 100%. LRs ranged from 1.35 to 26. Most of the included studies used cardiologists or internal medicine residents or specialists as auscultators, whereas two used general practitioners and two studied several different auscultators.
CONCLUSION
Sensitivity, specificity and LRs of auscultation varied considerably across the different studies. There is a sparsity of data from general practice, where auscultation of the heart is usually one of the main methods for detecting VHD. Based on this review, the diagnostic utility of auscultation is unclear and medical doctors should not rely too much on auscultation alone. More research is needed on how auscultation, together with other clinical findings and history, can be used to distinguish patients with VHD.
PROSPERO REGISTRATION NUMBER
CRD42018091675.
Topics: Adult; Humans; Heart Auscultation; Ultrasonography; Auscultation; Echocardiography; Heart Valve Diseases
PubMed: 36963797
DOI: 10.1136/bmjopen-2022-068121