Journal of Endovascular Therapy : An... Feb 2024Comparative effectiveness of fenestrated endovascular aneurysm repair (FEVAR) and chimney graft endovascular aneurysm repair (ChEVAR) for juxtarenal aortic aneurysms... (Review)
Review
OBJECTIVES
Comparative effectiveness of fenestrated endovascular aneurysm repair (FEVAR) and chimney graft endovascular aneurysm repair (ChEVAR) for juxtarenal aortic aneurysms (JAAs) remains unclear. Our objective was to identify and analyze the current body of evidence comparing the effectiveness of both techniques for JAA.
METHODS
We performed a systematic review and meta-analysis comparing the effectiveness of FEVAR and ChEVAR for JAA repair. We searched MEDLINE, EMBASE, and Cochrane Register for Controlled Trials from January 1, 1990, for randomized and non-randomized studies assessing outcomes of FEVAR and ChEVAR for JAA repair. Screening, data extraction, risk of bias assessment, and GRADE (Grading of Recommendations, Assessments, Development, and Evaluations) certainty of evidence were performed in duplicate. Data were pooled statistically where possible.
RESULTS
Nine retrospective cohort studies comparing the use of FEVAR and ChEVAR for juxtarenal aneurysm were included for meta-analysis. The FEVAR and ChEVAR arms of the meta-analysis consisted of 726 participants and 518 participants, respectively. There were 598 (86.8%) and 332 (81.6%) men in each arm. The mean diameter was larger in the ChEVAR arm (59 mm vs 52.5 mm). Both techniques had similar rates of postoperative 30-day mortality, 3.38% (8/237) versus 3.52% (8/227), acute kidney injury, 16.76% (31/185) versus 17.31% (18/104), and major adverse cardiac events, 7.30% (46/630) versus 6.60% (22/333). The meta-analysis supported the use of FEVAR for most outcomes, with significant advantage for technical success (odds ratio [OR]: 3.24, 95% CI: 1.24-8.42) and avoidance of type 1 endoleak (OR: 5.76, 95% CI: 1.94-17.08), but a disadvantage for spinal cord ischemia (OR: 10.21, 95% CI: 1.21-86.11), which had a very low number of events. The quality of evidence was "moderate" for most outcomes.
CONCLUSION
Both endovascular techniques had good safety profiles. The evidence does not support superiority of either FEVAR or ChEVAR for JAA.
CLINICAL IMPACT
While lack of equipoise has hampered the design of randomised trials of open versus endovascular repair of juxtarenal aortic aneurysms, concern about the durability of endovascular repair highlights the need for stronger evidence of the comparative efficacy of endovascular techniques. This review performed meta-analysis and evidence appraisal of recent data from large observational studies comparing fenestrated and chimney techniques, using a comprehensive outcome set. Superiority of either intervention could not be established due to differences in participants' baseline risk in each study arm. However, data suggests that both techniques are safe and suitable for use when indicated.
PubMed: 38388373
DOI: 10.1177/15266028241231171 -
Anatomy & Cell Biology Mar 2024The exocrine part of the pancreas has a duct system called the pancreatic ductal system (PDS). Its mechanism of development is complex, and any reorganization during...
The exocrine part of the pancreas has a duct system called the pancreatic ductal system (PDS). Its mechanism of development is complex, and any reorganization during early embryogenesis can give rise to anatomical variants. The aim of this study is to collect, classify, and analyze published evidence on the importance of anatomical variants of the PDS, addressing gaps in our understanding of such variations. The MEDLINE, Web of Science, Embase, and Google Scholar databases were searched to identify publications relevant to this review. R studio with meta-package was used for data extraction, risk of bias estimation, and statistical analysis. A total of 64 studies out of 1,778 proved suitable for this review and metanalysis. The meta-analysis computed the prevalence of normal variants of the PDS (92% of 10,514 subjects). Type 3 variants and "descending" subtypes of the main pancreatic duct (MPD) predominated in the pooled samples. The mean lengths of the MPD and accessory pancreatic duct (APD) were 16.53 cm and 3.36 cm, respectively. The mean diameters of the MPD at the head and the APD were 3.43 mm and 1.69 mm, respectively. The APD was present in only 41% of samples, and the long type predominated. The pancreatic ductal anatomy is highly variable, and the incorrect identification of variants may be challenging for surgeons during ductal anastomosis with gut, failure to which may often cause ductal obstruction or pseudocysts formation.
PubMed: 38351473
DOI: 10.5115/acb.23.148 -
Heliyon Feb 2024Drug-coated balloon (DCB) is a novel approach to avoiding stent-related complications and has proven effective for the treatment of in-stent restenosis (ISR) and small...
BACKGROUND
Drug-coated balloon (DCB) is a novel approach to avoiding stent-related complications and has proven effective for the treatment of in-stent restenosis (ISR) and small vessels. However, its role in the treatment of de novo lesions in large vessels is less settled.
AIMS
To estimate the efficacy and safety of drug-coated balloon versus stent in the treatment of de novo lesions in large coronary arteries.
METHODS
We searched the literature until April 2023. We judged the safety of DCB based on major adverse cardiovascular events (MACEs), cardiac death, all-cause mortality, non-fatal myocardial infarction, target lesion revascularization (TLR), and bleeding event; and efficacy according to late lumen loss (LLL), minimum lumen diameter (MLD). We conducted subgroup analyses according to stent type and whether urgent PCI was required.
RESULTS
A total of 10 RCTs were included. Overall, LLL (mean difference (MD) = -0.19, 95 % confidence interval (CI): -0.32 to -0.06, P = 0.003) was lower in the DCB group than in the Stent arm. This effect was consistent in subgroup analysis regardless of stent type and disease type. In terms of safety indicators, there were no significant differences between DCB and stent. The subgroup analyses found that safety indicators showed no significant differences between DCB and drug-eluting stent (DES), but TLR was lower in the DCB than in the bare metal stent (BMS). Moreover, in ST-elevation myocardial infarction (STEMI), safety indicators and LLL showed no significant differences between DCB and DES, but MLD in the DCB was smaller. While in patients with excluded STEMI, MACE and TLR was lower in the DCB compared with the overall stent.
CONCLUSIONS
DCB could be a promising alternative for treating de novo lesions in large coronary arteries with satisfactory efficacy and low risk, superior to BMS and not inferior to DES, with a trend toward lower late lumen loss.
PubMed: 38333846
DOI: 10.1016/j.heliyon.2024.e25264 -
Annals of Intensive Care Feb 2024The prevalence of hyperdynamic left ventricular (LV) systolic function in septic patients and its impact on mortality remain controversial. In this systematic review and...
PURPOSE
The prevalence of hyperdynamic left ventricular (LV) systolic function in septic patients and its impact on mortality remain controversial. In this systematic review and meta-analysis, we investigated the prevalence and association of hyperdynamic LV systolic function with mortality in patients with sepsis.
METHODS
We searched MEDLINE, Cochrane Central Register of Controlled Trials, and Embase. Primary outcomes were the prevalence of hyperdynamic LV systolic function in adult septic patients and the associated short-term mortality as compared to normal LV systolic function. Hyperdynamic LV systolic function was defined using LV ejection fraction (LVEF) of 70% as cutoff. Secondary outcomes were heart rate, LV end-diastolic diameter (LVEDD), and E/e' ratio.
RESULTS
Four studies were included, and the pooled prevalence of hyperdynamic LV systolic function was 18.2% ([95% confidence interval (CI) 12.5, 25.8]; I = 7.0%, P < 0.0001). Hyperdynamic LV systolic function was associated with higher mortality: odds ratio of 2.37 [95%CI 1.47, 3.80]; I = 79%, P < 0.01. No difference was found in E/e' (P = 0.43) between normal and hyperdynamic LV systolic function, while higher values of heart rate (mean difference: 6.14 beats/min [95%CI 3.59, 8.69]; I = 51%, P < 0.0001) and LVEDD (mean difference: - 0.21 cm [95%CI - 0.33, - 0.09]; I = 73%, P < 0.001) were detected in patients with hyperdynamic LV systolic function.
CONCLUSION
The prevalence of hyperdynamic LV systolic function is not negligible in septic patients. Such a finding is associated with significantly higher short-term mortality as compared to normal LV systolic function.
PubMed: 38308701
DOI: 10.1186/s13613-024-01255-9 -
Diagnostics (Basel, Switzerland) Jan 2024The nodule diameter was commonly used to predict the invasiveness of pulmonary adenocarcinomas in pure ground-glass nodules (pGGNs). However, the diagnostic performance... (Review)
Review
Predicting the Invasiveness of Pulmonary Adenocarcinomas in Pure Ground-Glass Nodules Using the Nodule Diameter: A Systematic Review, Meta-Analysis, and Validation in an Independent Cohort.
The nodule diameter was commonly used to predict the invasiveness of pulmonary adenocarcinomas in pure ground-glass nodules (pGGNs). However, the diagnostic performance and optimal cut-off values were inconsistent. We conducted a meta-analysis to evaluate the diagnostic performance of the nodule diameter for predicting the invasiveness of pulmonary adenocarcinomas in pGGNs and validated the cut-off value of the diameter in an independent cohort. Relevant studies were searched through PubMed, MEDLINE, Embase, and the Cochrane Library, from inception until December 2022. The inclusion criteria comprised studies that evaluated the diagnostic accuracy of the nodule diameter to differentiate invasive adenocarcinomas (IAs) from non-invasive adenocarcinomas (non-IAs) in pGGNs. A bivariate mixed-effects regression model was used to obtain the diagnostic performance. Meta-regression analysis was performed to explore the heterogeneity. An independent sample of 220 pGGNs (82 IAs and 128 non-IAs) was enrolled as the validation cohort to evaluate the performance of the cut-off values. This meta-analysis finally included 16 studies and 2564 pGGNs (761 IAs and 1803 non-IAs). The pooled area under the curve, the sensitivity, and the specificity were 0.85 (95% confidence interval (CI), 0.82-0.88), 0.82 (95% CI, 0.78-0.86), and 0.73 (95% CI, 0.67-0.78). The diagnostic performance was affected by the measure of the diameter, the reconstruction matrix, and patient selection bias. Using the prespecified cut-off value of 10.4 mm for the mean diameter and 13.2 mm for the maximal diameter, the mean diameter showed higher sensitivity than the maximal diameter in the validation cohort (0.85 vs. 0.72, < 0.01), while there was no significant difference in specificity (0.83 vs. 0.86, = 0.13). The nodule diameter had adequate diagnostic performance in differentiating IAs from non-IAs in pGGNs and could be replicated in a validation cohort. The mean diameter with a cut-off value of 10.4 mm was recommended.
PubMed: 38248024
DOI: 10.3390/diagnostics14020147 -
Cureus Dec 2023Circumscribed choroidal hemangioma (CCH) is a sort of non-malignant hamartomatous tumor that occurs in the choroidal layer of the eye. It is a rare condition that... (Review)
Review
Circumscribed choroidal hemangioma (CCH) is a sort of non-malignant hamartomatous tumor that occurs in the choroidal layer of the eye. It is a rare condition that affects people between their second and fourth decades of life, leading to significant deterioration of vision. One of the most catastrophic consequences of CCH is exudative retinal detachment (ERD), which has a severe impact on vision. This review aims to comprehensively assess the safety and efficacy of photodynamic therapy (PDT) using verteporfin as a therapeutic approach. Using the eligibility criteria, we analyzed the findings of 18 published articles from PubMed, Web of Science, Scopus, and Cochrane. The standard PDT protocol was used in all included studies, except two (one used half-dose, the other one used the double-dose) with an average of 1-2 sessions. PDT induced substantial tumor regression, with a mean thickness range from 0 to 2.3 mm. However, this contrasted with a previous study that reported a thickness of 3.46 mm as an indication of PDT failure. The mean tumor diameter varied from 4.8 mm to total tumor flattening. A suboptimal effect with a mean diameter ranging from 6mm to 8mm was found in two clinical studies. Significant improvement in vision was observed during the last follow-up, ranging from a normalization of Best Corrected Visual Acuity (BCVA) 20/20 to 20/80; counting finger vision persisted in two patients even after treatment. PDT successfully achieved complete subretinal fluid (SRF) resolution in 14 studies and resolved ERD in nine articles. Most studies did not report serious adverse events, but some reported macular atrophy, microcystic degeneration of the retina, transient visual disturbances, Retinal pigmented epithelium (RPE) metaplasia, and cystic degeneration of the retina. This systemic review demonstrated PDT's effectiveness and safety as a first-line management modality for CCH. Photodynamic therapy efficiently induced tumor regression, resulting in a notable reduction in both tumor diameter and thickness, with optimal efficacy to improve vision and resolution of the consequences of CCH, such as SRF and ERD.
PubMed: 38222120
DOI: 10.7759/cureus.50461 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Frontiers in Medicine 2023The progression of early stage non-small cell lung cancer (NSCLC) is closely related to epidermal growth factor receptor (EGFR) mutation status. The purpose of this...
Distinguishing EGFR mutant subtypes in stage IA non-small cell lung cancer using the presence status of ground glass opacity and final histologic classification: a systematic review and meta-analysis.
BACKGROUND
The progression of early stage non-small cell lung cancer (NSCLC) is closely related to epidermal growth factor receptor (EGFR) mutation status. The purpose of this study was to systematically investigate the relationship between EGFR mutation status and demographic, imaging, and ultimately pathologic features in patients with NSCLC.
METHODS
A complete literature search was conducted using the PubMed, Web of Science, EMBASE, and Cochrane Library databases to discover articles published by May 15, 2023 that were eligible. The relationship between EGFR mutation status and specific demographic, imaging, and ultimately pathologic features in patients with NSCLC was evaluated using pooled odds ratios (ORs) and their 95% confidence intervals (CIs). The standardized mean difference (SMD) with 95% CIs was the appropriate statistic to summarize standard deviations (SDs) means for continuous variables.
RESULTS
A total of 9 studies with 1789 patients were included in this analysis. The final findings suggested that patients with a greater age, female gender, and non-smoking status would have a relatively higher incidence of EGFR mutations. Additionally, the risk of EGFR mutations increased with larger tumor diameter, tumor imaging presentation of mixed ground glass opacity (mGGO), and tumor pathological findings of minimally invasive adenocarcinoma (MIA) or invasive adenocarcinoma (IAC). Significantly, malignancies presenting as MIA are more likely to contain L858R point mutations (OR = 1.80; 95% CI: 1.04-3.13; = 0.04) rather than exon 19 deletions (OR = 1.81; 95% CI: 0.95-3.44; = 0.07).
CONCLUSION
This meta-analysis showed that imaging parameters and histological classifications of pulmonary nodules may be able to predict stage IA NSCLC genetic changes.
PubMed: 38126071
DOI: 10.3389/fmed.2023.1268846 -
Journal of the Association of Medical... Nov 2023We sought to systematically review the existing research on pyogenic liver abscesses to determine what data exist on antibiotic treatment durations.
BACKGROUND
We sought to systematically review the existing research on pyogenic liver abscesses to determine what data exist on antibiotic treatment durations.
METHODS
We conducted a systematic review and meta-analysis of contemporary medical literature from 2000 to 2020, searching for studies of pyogenic liver abscesses. The primary outcome of interest was mean antibiotic treatment duration, which we pooled by random-effects meta-analysis. Meta-regression was performed to examine characteristics influencing antibiotic durations.
RESULTS
Sixteen studies (of 3,933 patients) provided sufficient data on antibiotic durations for pooling in meta-analysis. Mean antibiotic durations were highly variable across studies, from 8.4 (SD 5.3) to 68.9 (SD 30.3) days. The pooled mean treatment duration was 32.7 days (95% CI 24.9 to 40.6), but heterogeneity was very high ( = 100%). In meta-regression, there was a non-significant trend towards decreased mean antibiotic treatment durations over later study years (-1.14 days/study year [95% CI -2.74 to 0.45], = 0.16). Mean treatment duration was not associated with mean age of participants, percentage of infections caused by spp, percentage of patients with abscesses over 5 cm in diameter, percentage of patients with multiple abscesses, and percentage of patients receiving medical management. No randomized trials have compared treatment durations for pyogenic liver abscess, and no observational studies have reported outcomes according to treatment duration.
CONCLUSIONS
Among studies reporting on antibiotic durations for pyogenic liver abscess, treatment practices are highly variable. This variability does not seem to be explained by differences in patient, pathogen, abscess, or management characteristics. Future RCTs are needed to guide optimal treatment duration for patients with this complex infection.
PubMed: 38058494
DOI: 10.3138/jammi-2023-0004 -
Heart Rhythm O2 Nov 2023Left bundle branch area pacing (LBBAP) may offer greater physiological benefits than traditional biventricular pacing (BiVP). However, there are limited data comparing...
BACKGROUND
Left bundle branch area pacing (LBBAP) may offer greater physiological benefits than traditional biventricular pacing (BiVP). However, there are limited data comparing the efficacy of LBBAP vs BiVP in patients with systolic heart failure (HF).
OBJECTIVE
The purpose of this meta-analysis was to compare the feasibility and electromechanical and clinical outcomes of both LBBAP and BiVP.
METHODS
We conducted a systematic review of studies retrieved from various databases including PubMed, Embase, Google Scholar, Scopus, and Cochrane Central Register of Control Trials (CENTRAL) published up to May 22, 2023. The risk ratio (RR) and standardized mean difference (SMD) with corresponding 95% confidence intervals (CIs) were calculated for dichotomous and continuous outcomes, respectively.
RESULTS
We included 12 studies with a total of 3004 patients (LBBAP = 1242, BiVP = 1762). Pooled results showed that LBBAP resulted in a significant increase in left ventricular ejection fraction (SMD 0.40, 95% CI 0.25, 0.54, .00001), echocardiographic response (RR 1.19, 95% CI 1.10 to 1.29, .0001), improvement in New York Heart Association functional class (SMD -0.44, 95% CI -0.65 to -0.23, .0001), QRS duration reduction (SMD -0.90, 95% CI -1.14 to -0.66, .00001), left ventricular end-diastolic diameter reduction (SMD -0.31, 95% CI -0.57 to -0.05, .02), fewer HF hospitalizations (RR 0.72, 95% CI 0.62, 0.85, .0001), and improved survival (RR 0.73, 95% CI 0.58, 0.92, .007). In addition, LBBAP was associated with shorter fluoroscopy time (SMD -0.94, 95% CI -1.42 to -0.47, .0001) and lower pacing threshold at implantation (SMD -1.03, 95% CI -1.32 to -0.74, .00001) and at 6 months (SMD -1.44, 95% CI -2.11 to -0.77, .0001) as compared with BiVP.
CONCLUSION
Compared with BiVP, LBBAP was associated with better electromechanical and clinical outcomes, including left ventricular ejection fraction, QRS duration, echocardiographic response, New York Heart Association functional class, HF hospitalization, and all-cause mortality in patients with systolic HF.
PubMed: 38034886