Neurospine Jun 2023Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2...
Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2 most commonly employed cage materials are titanium (Ti) alloy and polyetheretherketone (PEEK). While Ti alloy implants have superior osteoinductive properties they more poorly match the biomechanical properties of cancellous bones. Newly developed 3-dimensional (3D)-printed porous titanium (3D-pTi) address this disadvantage and are proposed as a new standard for lumbar interbody fusion (LIF) devices. In the present study, the literature directly comparing 3D-pTi and PEEK interbody devices is systematically reviewed with a focus on fusion outcomes and subsidence rates reported in the in vitro, animal, and human literature. A systematic review directly comparing outcomes of PEEK and 3D-pTi interbody spinal cages was performed. PubMed, Embase, and Cochrane Library databases were searched according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. Mean Newcastle-Ottawa Scale score for cohort studies was 6.4. A total of 7 eligible studies were included, comprising a combination of clinical series, ovine animal data, and in vitro biomechanical studies. There was a total population of 299 human and 59 ovine subjects, with 134 human (44.8%) and 38 (64.4%) ovine models implanted with 3D-pTi cages. Of the 7 studies, 6 reported overall outcomes in favor of 3D-pTi compared to PEEK, including subsidence and osseointegration, while 1 study reported neutral outcomes for device related revision and reoperation rate. Though limited data are available, the current literature supports 3D-pTi interbodies as offering superior fusion outcomes relative to PEEK interbodies for LIF without increasing subsidence or reoperation risk. Histologic evidence suggests 3D-Ti to have superior osteoinductive properties that may underlie these superior outcomes, but additional clinical investigation is merited.
PubMed: 37401063
DOI: 10.14245/ns.2346244.122 -
European Review For Medical and... Jun 2023Recently, nutraceuticals have been widely explored in many medical fields and their use is also increasing in oral and dental problems. Since the nutraceutical evidence... (Review)
Review
OBJECTIVE
Recently, nutraceuticals have been widely explored in many medical fields and their use is also increasing in oral and dental problems. Since the nutraceutical evidence landscape in the literature has not been fully elucidated yet, this review aims to examine the effects of commercially available nutraceuticals and their potential evidence and applications in dentistry.
MATERIALS AND METHODS
A scoping review was conducted following the "Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR)" checklist. The electronic search was performed using PubMed/MEDLINE, EMBASE, the Cochrane Library, and Web of Science on March 2022. The inclusion criteria include humans, clinical trials, randomized controlled trials (RCT), reviews, and systematic reviews published over the last ten years.
RESULTS
18 studies met the eligibility criteria. There were 2 RCTs, 11 systematic reviews, and four narrative reviews. In most studies, the clinical indications were oral leucoplakia, periodontitis, osseointegration of implants, oral mucositis, oral clefts, and oral health. Probiotics, prebiotics, polyunsaturated fatty acids, and vitamins A, B, C, D, and E were the most common nutraceuticals used in dentistry.
CONCLUSIONS
Nutraceuticals are foods that, according to the literature, may be useful for preventing and treating dental diseases.
Topics: Humans; Dietary Supplements; Vitamins; Osseointegration; Vitamin A; Dentistry
PubMed: 37318464
DOI: 10.26355/eurrev_202306_32607 -
Journal of Indian Society of... 2023Dental implant is a material used in replacing missing teeth. The osseointegration process of dental implants will be affected by the macrodesign of the fixtures. This... (Review)
Review
Dental implant is a material used in replacing missing teeth. The osseointegration process of dental implants will be affected by the macrodesign of the fixtures. This study aimed to review the dental implant macrodesign in the past 10 years. This study was conducted in a systematic review method using two electronic databases (PUBMED and Science Direct). Only randomized controlled trials (RCTs) published in the last 10 years were used for this review. All the search results were filtered using Preferred Reporting Items for Systematic Reviews And Meta-Analyses and should fulfill some predefined inclusion criteria. The last step was to assess the methodological quality of the studies using the JBI Checklist for RCT. The search identified 357 studies with only 23 that going through full-text analysis, resulting in 14 articles included in the review. In total, 19 different implant brands were used in 12 different countries. Dental implant macrodesigns were divided into collar design, implant shape, thread geometry, and platform design. The macrodesign features of the implant were mostly developed in the variation of thread geometry and collar design.
PubMed: 37152458
DOI: 10.4103/jisp.jisp_676_21 -
Journal of Maxillofacial and Oral... Jun 2023Implants are preferred for replacement of missing teeth by the clinicians as well as the patients. Lesser alveolar bone density doesn't preclude any individual for... (Review)
Review
BACKGROUND
Implants are preferred for replacement of missing teeth by the clinicians as well as the patients. Lesser alveolar bone density doesn't preclude any individual for choosing this option but warrants for extra caution. Preclinical studies have explored the osteoinductive potential of statins, but results should be analyzed vigorously before implementing them in humans. There is no meta-analysis to document effect of statins on bone formation around implants in osteoporotic animals.
METHODS AND MATERIAL
PubMed, Embase and Cochrane were searched for studies investigating the effect of statins on bone implant contact (BIC %), bone mineral density (BMD %) and bone volume (BV %) around implants at 2, 4 and 12 weeks. Meta-analysis was performed on subgroups with osteoporotic animals which were administered statins through different routes.
RESULTS
Quantitative data from 12 studies showed favorable effect of statins on bone around implants. Positive difference was observed at 4 weeks in BIC (parenteral [SMD = 4.33 (2.89, 5.77); = 3%)], BMD (local [SMD = 1.33 (0.51, 2.15); = 0%] and BV (local [SMD = 1.58 (0.76, 2.40); = 0%]. BIC [SMD = 1.40 (0.89, 1.90); = 0%] and BV [SMD = 3.91 (2.33, 5.50); = 43%] were higher in experimental group after 12 weeks of oral administration.
CONCLUSIONS
Statins can be investigated as potential bone graft materials to increase the predictability of osseointegration especially in osteoporotic individuals. Future research should focus to reproduce homogeneous data and conclusive recommendations which can be applied in clinical trials.
SUPPLEMENTARY INFORMATION
The online version contains supplementary material available at 10.1007/s12663-023-01873-z.
PubMed: 37122799
DOI: 10.1007/s12663-023-01873-z -
The Saudi Dental Journal Mar 2023In spite of bone's healing capacity, critical-size bone defect regeneration and -implant osseointegration are challenging. Tissue engineering provides better outcomes,... (Review)
Review
BACKGROUND AND OBJECTIVES
In spite of bone's healing capacity, critical-size bone defect regeneration and -implant osseointegration are challenging. Tissue engineering provides better outcomes, but requires expensive adjuncts like stem cells, growth factors and bone morphogenic proteins. Vitamin D (Vit.D) regulates calcium and phosphorus metabolism, and helps maintain bone health. Vit.D supplements in deficient patients, accentuates bone healing and regeneration. Therefore the aim of this systematic review was to evaluate the role of adjunctive Vit.D on bone defect regeneration.
METHODS
Comprehensive database search of indexed literature, published between January 1990 and June 2022, was carried out. English language articles fulfilling inclusion criteria (clinical/in vivo studies evaluating bone regeneration including osseointegration and in vitro studies assessing osteogenic differentiation, with adjunct Vit.D) were identified and screened.
RESULTS
Database search identified 384 titles. After sequential title, abstract and full-text screening, 23 studies (in vitro - 9/in vivo - 14) were selected for review. Vit.D as an adjunct with stem cells and osteoblasts resulted in enhanced osteogenic differentiation and upregulation of genes coding for bone matrix proteins and alkaline phosphatase. When used in vivo, Vit.D resulted in early and increased new bone formation and mineralization within osseous defects, and better bone implant contact and osseointegration, around implants. Adjunct Vit.D in animals with induced systemic illnesses resulted in bone defect regeneration and osseointegration comparable to healthy animals. While systemic and local administration of Vit.D resulted in enhanced bone defect healing, outcomes were superior with systemic route.
CONCLUSIONS
Based on this review, adjunct Vit.D enhances bone defect regeneration and osseointegration. In vitro application of Vit.D to stem cells and osteoblasts enhances osteogenic differentiation. Vit.D is a potentially non-invasive and inexpensive adjunct for clinical bone regeneration and osseointegration. Long term clinical trials are recommended to establish protocols relating to type, dosage, frequency, duration and route of administration.
PubMed: 37091280
DOI: 10.1016/j.sdentj.2023.02.002 -
Photobiomodulation, Photomedicine, and... Mar 2023This analysis was designed to present a summary of available evidence that will inform practice and guide future research for photobiomodulation (PBM) after titanium... (Meta-Analysis)
Meta-Analysis Review
This analysis was designed to present a summary of available evidence that will inform practice and guide future research for photobiomodulation (PBM) after titanium implant placement procedures. A systematic review was performed according to the Cochrane Collaboration and in line with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) criteria. Two investigators screened the titles and abstracts, and reviewed articles for risk of bias. Online databases searched included PubMed, Embase, Scopus, and Web of Science. Terms were specific to the effects of PBM on dental implant stability. Eight hundred fifty-six studies were identified, and 15 studies fulfilled the inclusion criteria. Light sources included both laser and light emitting diode (LED) devices. Wavelengths ranged from 618 to 1064 nm. The meta-analysis concluded that all 15 published studies were able to safely apply PBM near dental implants without adverse events. Laser and LED wavelengths that reported significant results included 618, 626, 830, 940 (2 × ), and 1064 nm. The use of adjunctive PBM can be safely prescribed after surgical placement of titanium implants. Six groups reported statistical significance for improving implant stability (four laser diode, two LED) in wavelengths ranging from 618 to 1064 nm. The amount of time spent delivering PBM was not a variable that differentiated whether a study reported significant results.
Topics: Titanium; Lasers, Semiconductor; Low-Level Light Therapy
PubMed: 36856530
DOI: 10.1089/photob.2022.0161 -
Journal of Clinical Medicine Feb 2023Among the common procedures in clinical practice in the field of dentistry is prosthetic rehabilitation through the insertion of dental implants. In order to obtain the... (Review)
Review
Among the common procedures in clinical practice in the field of dentistry is prosthetic rehabilitation through the insertion of dental implants. In order to obtain the best aesthetic and functional results, the oral surgeon who deals with implantology must be able to position the dental implants correctly; a crucial role is therefore played by the diagnostic and treatment planning phases, where attention must be paid to anatomical constraints and prosthetic constraints in the alveolar bone site. The parameters, such as bone quality, bone volume, and anatomical restrictions, can be processed and simulated using implant planning software. The simulation of the virtual positioning of the implant can lead to the construction of a three-dimensional model of the implant positioning guide, which can be used during the implant surgery. The aim of this systematic review is to evaluate survival rates, early and late failure rates, peri-implant bone remodeling, and possible implant-prosthetic complications related to implants placed using digitally designed surgical guides. This systematic review was written following the indications of PRISMA and envisaged the use of 3 databases: Scopus, PubMed, and Cochrane Library. Results: Only 9 of the 2001 records were included, including 2 retrospective studies and 7 prospective studies. Conclusion: On the basis of the studies selected in this review, it can be seen that the implant survival obtained with the use of guided implant surgery shows high percentages. Many recorded failures occurred early, due to a lack of osseointegration, and the variables that come into play in the survival of the implants are many.
PubMed: 36836025
DOI: 10.3390/jcm12041490 -
International Journal of Environmental... Jan 2023The aim of this systematic review and case reports was to evaluate osseointegration and implant survival rate in patients with chronic kidney disease.
BACKGROUND
The aim of this systematic review and case reports was to evaluate osseointegration and implant survival rate in patients with chronic kidney disease.
METHODS
The paper screening process was conducted on electronic databases in order to identify clinical studies concerning the study topic. The literature data were evaluated for eligibility and studies were included for the qualitative synthesis. The case report concerned a male subject affected by renal disorders, a candidate for full arch immediate loading procedure.
RESULTS
The article screening process reported a total of 54 manuscripts and one paper identified through the manual search. At the end of the review process, a total of 45 articles were excluded while nine manuscripts were included for the descriptive synthesis. No significant complications or events were present during the intraoperative/post-operative phases. The clinical course reported no significant inflammation or symptoms. At follow-up, the rehabilitation was found to be functionally and aesthetically integrated with no complications, probing, or bone resorption.
CONCLUSIONS
The available evidence supports the clinical efficacy of the early implant placement protocol. Present findings indicate that the early implant placement protocol results in implant outcomes similar to immediate and delayed placement protocols and a superior stability of peri-implant hard tissue compared with immediate implant placement.
Topics: Humans; Male; Treatment Outcome; Renal Insufficiency, Chronic
PubMed: 36767768
DOI: 10.3390/ijerph20032401 -
Journal of Orthopaedic Surgery and... Jan 2023To investigate the risk of postoperative function and complications associated with reconstruction methods in patients with short residual proximal femurs (< 12 cm)...
BACKGROUND
To investigate the risk of postoperative function and complications associated with reconstruction methods in patients with short residual proximal femurs (< 12 cm) after resection of distal femoral bone tumors, we performed a systematic review of studies reporting postoperative function and complications in these patients.
METHODS
Of the 236 studies identified by systematic searches using the Medline, Embase, and Cochrane Central Register of Controlled Trials databases, eight were included (none were randomized controlled trials). In these studies, 106 (68.4%), 12 (7.7%), and 37 (23.9%) patients underwent reconstruction with custom-made megaprostheses with extracortical plates or cross-pins, allograft prosthetic composite (APC), and Compress compliant pre-stress (CPS) implants, respectively.
RESULTS
Aseptic loosening occurred slightly more frequently in the APC group than in the other reconstruction methods (APC group, 21%; custom-made megaprosthesis group, 0-17%; CPS implant group, 14%). No differences were noted in the frequencies of implant breakage, fractures, or infections between the three reconstruction methods. Mechanical survival, where endpoint was set as implant removal for any reason, was 80% at seven years in the APC group, 70-77% at 10 years in the custom-made megaprosthesis group, and 68% at nine years in the CPS implant group. Therefore, there appeared to be no difference among the three reconstruction methods with respect to mechanical survival.
CONCLUSIONS
During megaprosthetic reconstruction of the distal femur with a short residual proximal femur after bone tumor resection, similar results were obtained using custom-made megaprostheses, APCs, and CPS implants.
Topics: Humans; Prosthesis Design; Prosthesis Failure; Treatment Outcome; Femur; Bone Neoplasms; Femoral Neoplasms; Arthroplasty, Replacement, Knee; Retrospective Studies
PubMed: 36707881
DOI: 10.1186/s13018-023-03553-7 -
Journal of Orthopaedic Surgery and... Jan 2023Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress...
BACKGROUND
Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood.
METHODS
In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.'
RESULTS
After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design.
CONCLUSION
Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.
Topics: Humans; Porosity; Prostheses and Implants; Arthroplasty, Replacement, Hip; Prosthesis Design
PubMed: 36647070
DOI: 10.1186/s13018-022-03492-9