-
Maxillofacial Plastic and... Jul 2022After tooth extraction, dimensional changes affect the alveolar socket, leading to loss in alveolar bone height and width. Histological modifications also occur, with... (Review)
Review
After tooth extraction, dimensional changes affect the alveolar socket, leading to loss in alveolar bone height and width. Histological modifications also occur, with initial formation of a blood clot that is replaced with granulation tissue and subsequently with a provisional connective tissue matrix. Spontaneous healing ends with socket filling with woven bone, which is gradually replaced with lamellar bone and bone marrow. Adequate alveolar ridge dimensions and bone quality are required to assure optimal stability and osseointegration following dental implant placement. When a tooth is extracted, alveolar ridge preservation (ARP) procedures are an effective method to prevent collapse of the post-extraction socket. Heterologous bone is widely chosen by clinicians for ARP, and anorganic bone xenografts (ABXs) made bioinert by heat treatment represents the most used biomaterial in clinical applications. Collagen-preserving bone xenografts (CBXs) made of porcine or equine bone are fabricated by less invasive chemical or enzymatic treatments to remove xenogenic antigens, and these are also effective in preserving post-extraction sites. Clinical differences between anorganic bone substitutes and collagen-preserving materials are not well documented in the literature but understanding these differences could clarify how processing protocols influence biomaterial behavior in situ. This systematic review of the literature compares the dimensional changes and histological features of ABXs versus CBXs in ridge preservation procedures to promote awareness of different bone xenograft efficacies in stimulating the healing of post-extraction sockets.
PubMed: 35821286
DOI: 10.1186/s40902-022-00349-3 -
BMC Medical Imaging Aug 2020This study aimed to develop evidence-based clinical imaging guidelines to assess the proper implant location following implant surgery and identify potential... (Review)
Review
BACKGROUND
This study aimed to develop evidence-based clinical imaging guidelines to assess the proper implant location following implant surgery and identify potential complications during follow-up.
METHODS
The guideline development process employed an adaptation methodology in accordance with the Korean clinical imaging guidelines (K-CIG). Core (Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, and Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoMGI) were searched used to retrieve guidelines, and two reviewers analyzed the retrieved articles. The articles were included in this review using well-established inclusion criteria.
RESULTS
Our online search identified 66 articles, of which 3 were selected for the development of the guidelines. Consequently, based on these three guidelines, we formulated distinct recommendations regarding the appropriate imaging modalities that should be used following implant placement.
CONCLUSIONS
Conventional imaging (e.g., periapical or panoramic radiography) should be the first choice for assessing the implant following its placement and osseointegration. The metal artifacts in Cone Beam Computed Tomography (CBCT) should be considered. However, CBCT is recommended for patients with sensory abnormalities following dental implant surgery to evaluate and identify the underlying cause of implant complications and to determine the appropriate treatment.
Topics: Cone-Beam Computed Tomography; Dental Implants; Evidence-Based Dentistry; Humans; Osseointegration; Practice Guidelines as Topic; Radiography, Panoramic
PubMed: 32867728
DOI: 10.1186/s12880-020-00501-3 -
BMC Oral Health Nov 2021Osseointegration is essential for the success and stability of implants. Platelet concentrates were reported to enhance osseointegration and improve implant stability.... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Osseointegration is essential for the success and stability of implants. Platelet concentrates were reported to enhance osseointegration and improve implant stability. The purpose of this review is to systematically analyze the effects of platelet concentrates on implant stability and marginal bone loss.
METHODS
Two researchers independently performed searches in the following databases (last searched on 21 July 2021): MEDLINE (PubMed), Cochrane Library, EMBASE, and Web of Science. In addition, a manual search was carried out on references of relevant reviews and initially included studies. All randomized controlled trials (RCTs) and controlled clinical trials (CCTs) on the application of platelet concentrates in the implant surgery procedure were included. The risk of bias of RCTs and CCTs were assessed with a revised Cochrane risk of bias tool for randomized trials (RoB 2.0) and the risk of bias in non-randomized studies-of interventions (ROBINS-I) tool, respectively. Meta-analyses on implant stability and marginal bone loss were conducted. Researchers used mean difference or standardized mean difference as the effect size and calculated the 95% confidence interval. In addition, subgroup analysis was performed based on the following factors: type of platelet concentrates, method of application, and study design.
RESULTS
Fourteen studies with 284 participants and 588 implants were included in the final analysis. 11 studies reported implant stability and 5 studies reported marginal bone level or marginal bone loss. 3 studies had high risk of bias. The meta-analysis results showed that platelet concentrates can significantly increase implant stability at 1 week (6 studies, 302 implants, MD 4.26, 95% CI 2.03-6.49, P < 0.001) and 4 weeks (8 studies, 373 implants, MD 0.67, 95% CI 0.46-0.88, P < 0.001) after insertion, significantly reduced marginal bone loss at 3 months after insertion (4 studies, 95 implants, mesial: MD - 0.33, 95% CI - 0.46 to - 0.20, P < 0.001; distal: MD - 0.38, 95% CI - 0.54 to - 0.22, P < 0.001). However, the improvement of implant stability at 12 weeks after insertion was limited (P = 0.10). Subgroup analysis showed that PRP did not significantly improve implant stability at 1 week and 4 weeks after insertion (P = 0.38, P = 0.17). Platelet concentrates only placed in the implant sites did not significantly improve implant stability at 1 week after insertion (P = 0.20).
CONCLUSIONS
Platelet concentrates can significantly improve implant stability and reduce marginal bone loss in the short term. Large-scale studies with long follow-up periods are required to explore their long-term effects and compare effects of different types.
TRIAL REGISTRATION
This study was registered on PROSPERO, with the Registration Number being CRD42021270214.
Topics: Dental Implantation, Endosseous; Dental Implants; Humans; Osseointegration
PubMed: 34772376
DOI: 10.1186/s12903-021-01929-x -
International Journal of Implant... Jul 2018The literature states that Strontium (Sr) is able to simultaneously stimulate bone formation and suppress bone resorption. Recent animal studies suggest that the... (Review)
Review
The literature states that Strontium (Sr) is able to simultaneously stimulate bone formation and suppress bone resorption. Recent animal studies suggest that the systemic administration of Sr, in the form of strontium ranelate (SRAN), would enhance the osseointegration of implants. The purpose of the present study was to undertake a systematic review on animal studies evaluating the systemic administration of Sr to enhance the osseointegration of titanium implants and the remodeling of bone grafts. The MEDLINE (PubMed) and Scopus bibliographic databases were searched from 1950 to October 2017 for reports on the use of systemic and non-radioactive Sr to enhance the osseointegration of titanium implants and the remodeling of bone grafts in animals. The search strategy was restricted to English language publications using the combined terms: "strontium" and "implant or graft or biomaterial or bone substitute". Five studies were included, all related to the systemic administration of Sr in the form SRAN, and its effects on osseointegration of titanium implants. No studies on the use of SRAN-based therapy to enhance the remodeling of bone grafts were found. The studies differed notably with respect to the study population (healthy female rats, healthy male rats, and female rats with induced osteoporosis) and SRAN dose (ranging from 500 to 1000 mg/kg/day). Results were diverse, but a tendency suggesting positive influence of systemic SRAN administration on the osseointegration of titanium implants was observed. No major side-effects due to strontium administration were reported. Systemic Sr administration, in the form of SRAN, seems to enhance peri-implant bone quality and implant osseointegration in animals, however, at a moderate extent. Further studies, evaluating both the effects of this drug on implant osseointegration and the risk/benefit of its use, are needed to provide a rationale of this therapeutic approach.
PubMed: 30014305
DOI: 10.1186/s40729-018-0132-8 -
Journal of Clinical Medicine Oct 2022Spinal fusion (SF) comprises surgical procedures for several pathologies that affect different spinal levels, and different cages are employed in SF surgery. Few... (Review)
Review
Spinal fusion (SF) comprises surgical procedures for several pathologies that affect different spinal levels, and different cages are employed in SF surgery. Few clinical studies highlight the role of cages in complications beyond the outcomes. The aim of this systematic review is to collect the last 10 years' worth of clinical studies that include cages in SF surgery, focusing on complications. Three databases are employed, and 21 clinical studies are included. The most-performed SF procedure was anterior cervical discectomy and fusion (ACDF), followed by lumbar SF. The polyetheretherketone (PEEK) cage was the most-used, and it was usually associated with autograft or calcium phosphate ceramics (hydroxyapatite (HA) and tricalcium phosphate (βTCP)). For lumbar SF procedures, the highest percentages of subsidence and pseudoarthrosis were observed with PEEK filled with bone morphogenetic protein 2 (BMP2) and βTCP. For ACDF procedures, PEEK filled with autograft showed the highest percentages of subsidence and pseudoarthrosis. Most studies highlighted the role of surgical techniques in patient complications. There are many interacting events that contextually affect the rate of clinical success or failure. Therefore, in future clinical studies, attention should focus on cages to improve knowledge of chemical, biological and topographical characteristics to improve bone growth and to counteract complications such as cage loosening or breaking and infections.
PubMed: 36362508
DOI: 10.3390/jcm11216279 -
Biomedizinische Technik. Biomedical... Feb 2024To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). (Review)
Review
OBJECTIVES
To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ).
CONTENT
Methods to evaluate the stability of dental implants.
SUMMARY
A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined "resonance frequency analysis" and "Periotest" with "correlation" or "relationship"; and combinations of "implant stability quotient" and "Periotest" with "correlation" or "relationship." The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability.
OUTLOOK
This review can serve as a reference for the development of methodologies for future clinical studies on this topic.
Topics: Humans; Osseointegration; Dental Implants; Dental Implantation, Endosseous; Dental Prosthesis Retention
PubMed: 37489593
DOI: 10.1515/bmt-2023-0194 -
Photobiomodulation, Photomedicine, and... Mar 2023This analysis was designed to present a summary of available evidence that will inform practice and guide future research for photobiomodulation (PBM) after titanium... (Meta-Analysis)
Meta-Analysis Review
This analysis was designed to present a summary of available evidence that will inform practice and guide future research for photobiomodulation (PBM) after titanium implant placement procedures. A systematic review was performed according to the Cochrane Collaboration and in line with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) criteria. Two investigators screened the titles and abstracts, and reviewed articles for risk of bias. Online databases searched included PubMed, Embase, Scopus, and Web of Science. Terms were specific to the effects of PBM on dental implant stability. Eight hundred fifty-six studies were identified, and 15 studies fulfilled the inclusion criteria. Light sources included both laser and light emitting diode (LED) devices. Wavelengths ranged from 618 to 1064 nm. The meta-analysis concluded that all 15 published studies were able to safely apply PBM near dental implants without adverse events. Laser and LED wavelengths that reported significant results included 618, 626, 830, 940 (2 × ), and 1064 nm. The use of adjunctive PBM can be safely prescribed after surgical placement of titanium implants. Six groups reported statistical significance for improving implant stability (four laser diode, two LED) in wavelengths ranging from 618 to 1064 nm. The amount of time spent delivering PBM was not a variable that differentiated whether a study reported significant results.
Topics: Titanium; Lasers, Semiconductor; Low-Level Light Therapy
PubMed: 36856530
DOI: 10.1089/photob.2022.0161 -
Medicina Oral, Patologia Oral Y Cirugia... May 2015A systematic review is made to determine whether human immunodeficiency virus (HIV) infection has an impact upon dental implant osseointegration. (Review)
Review
OBJECTIVE
A systematic review is made to determine whether human immunodeficiency virus (HIV) infection has an impact upon dental implant osseointegration.
STUDY DESIGN
A PubMed (MEDLINE) literature search was made of articles published up until 14 April 2014. The systematic review was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA). The quality of the studies included in the review was assessed using the Methodological Index for Nonrandomized Studies (MINORS) and levels of evidence (based on the University of Oxford's Center for Evidence Based Medicine criteria).
RESULTS
The combinations of search terms resulted in a list of 132 titles. Nine studies finally met the inclusion criteria and were selected for inclusion in the systematic review. A total of 173 dental implants were placed in 80 patients (135 implants in 56 HIV-positive subjects and 38 implants in 24 HIV-negative patients), and a single loss of dental implant osseointegration was recorded in an HIV-positive patient.
CONCLUSIONS
Our results suggest that dental implant placement in HIV-positive patients does not increase the dental implant failure rate. Prophylactic antibiotic treatment, the administration of highly active antiretroviral therapy, and control of the CD4+ T lymphocyte counts appear to be the main influencing factors in this respect. Given the few studies included in our systematic review, further prospective studies involving larger sample sizes and longer durations of follow-up are required in order to confirm the results obtained.
Topics: Dental Implantation, Endosseous; Dental Implants; HIV Infections; Humans; Risk Factors
PubMed: 25662560
DOI: 10.4317/medoral.20408 -
Journal of Dental Research, Dental... 2021It is critical to understand laser-microtextured implant collars' influence on peri-implant pocket depths and marginal bone levels, especially in crucial areas. The... (Review)
Review
It is critical to understand laser-microtextured implant collars' influence on peri-implant pocket depths and marginal bone levels, especially in crucial areas. The present review investigated the peri-implant marginal bone loss (MBL) and pocket depths and failure rates of dental implants with laser-microtextured collars. An electronic search was run in the PubMed and Embase databases until September 15, 2019. Randomized and prospective clinical studies comparing peri-implant MBL and pocket depths and failure rates between implants with laser-microtextured and machined collar surfaces were included. Five studies (two cohort studies and three RCTs) were included in the meta-analysis after the inclusion and exclusion criteria and qualitative assessments were applied. The risk ratio of osseointegrated implant failure and mean differences in peri-implant MBL and pocket depths were calculated using the Comprehensive Meta-Analysis (CMA) software. Implants with laser-microtextured collars exhibited significantly better marginal bone level scores ( < 0.001; MD: 0.54; 95% CI: 0.489‒0.592) and a significant reduction in peri-implant probing depths than implants with machined collars ( < 0.001; MD: 1.01; 95% CI: 0.90‒1.13). The assessed studies showed that 17 out of 516 implants failed (3.29%), comprising nine implants with machined (3.62%) and eight implants with laser-microtextured collars (2.98%). However, no significant differences were detected in the implant neck surface characterization ( = 0.695; RR: 1.205; 95% CI: 0.472‒3.076). This study suggests that laser-microtexturing of implant collar significantly affected the peri-implant MBL and probing depths. Although no significant differences were noted in implant failure rates between implants with laser-microtextured and machined collar surfaces, the peri-implant MBL and probing depths with laser-microtextured collars were significantly lower than the machined collars.
PubMed: 35070185
DOI: 10.34172/joddd.2021.048 -
Journal of Dental Research Dec 2013This review aimed at evaluating the effectiveness of reconstructive procedures for treating peri-implantitis. Searches of electronic databases and cross-referencing were... (Review)
Review
This review aimed at evaluating the effectiveness of reconstructive procedures for treating peri-implantitis. Searches of electronic databases and cross-referencing were performed for human comparative clinical trials with ≥ 10 implants for ≥ 12 months of follow-up, reporting radiographic defect fill and at least one of the following parameters: probing depth reduction, clinical attachment level gain, bleeding on probing reduction, and mucosal recession. The searches retrieved 430 citations. Only 1 randomized controlled trial was identified, which compared reconstructive therapy and open flap debridement. Case series studies were also included to evaluate the overall performance of the reconstructive procedures. Twelve studies were finally included. Meta-analysis revealed that the weighted mean radiographic defect fill was 2.17 mm (95% confidence interval [CI]: 1.46-2.87 mm), probing depth reduction was 2.97 mm (95% CI: 2.38-3.56 mm), clinical attachment level gain was 1.65 mm (95% CI: 1.17-2.13 mm), and bleeding on probing reduction was 45.8% (95% CI: 38.5%-53.3%). Great variability in reparative outcomes was found, attributed to patient factors, defect morphology, and reconstructive agents used. Currently, there is a lack of evidence for supporting additional benefit of reconstructive procedures to the other treatment modalities for managing peri-implantitis.
Topics: Gingival Hemorrhage; Gingival Recession; Guided Tissue Regeneration, Periodontal; Humans; Peri-Implantitis; Periodontal Attachment Loss; Periodontal Pocket; Plastic Surgery Procedures
PubMed: 24158331
DOI: 10.1177/0022034513509279