Frontiers in Surgery 2022Atherosclerotic extracranial carotid artery stenosis accounts for about 20%-30% of all strokes, which is one of the leading causes of adult morbidity and mortality....
INTRODUCTION
Atherosclerotic extracranial carotid artery stenosis accounts for about 20%-30% of all strokes, which is one of the leading causes of adult morbidity and mortality. Although carotid endarterectomy (CEA) is still the mainly operational manner for atherosclerotic carotid artery stenosis/occlusion (ACAS/ACAO), and carotid angioplasty and stenting (CAS) have been used as an alternative, both CEA and CAS have limitations of their own, such as extensive invasiveness and in-stent restenosis.
METHODS
In this study we established a novel interventional system to take advantage of both CEA and CAS. Twenty consecutive carotid atherosclerotic plaques were harvested from the patients who underwent CEA. The plaques were randomized into two groups and inserted into the pruned and sutured descending aortas of the swine . The ZebraScope™ was modified with a protective device on its flexible tip, so that the plaque could be dissected from the wall of parent carotid artery and ablated completely without damage to the carotid artery. The holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) generators were alternately used when needed.
RESULTS
All the carotid atherosclerotic plaques were completely ablated by Ho:YAG laser and/or TFL. The Ho:YAG laser was more effective for the atherosclerotic plaques with severe calcification, while the TFL was more suitable for those with moderate calcification. There were still some thermal injury spots on the inner wall of the parent carotid artery caused by the laser in the non-protected group B. In the protected group A, on the contrary, there was no even a thermal injury spot was found on the relevant location except for one sample. The difference of ablating duration was statistically significant between group A (36.5 ± 4.79 min) and group B (63.4 ± 6.55 min) ( < 0.01).
CONCLUSION
According to our knowledge, this is the first attempt to ablate carotid atherosclerotic plaques assisted by the ZebraScope™ . The protective and dissecting device on the tip of the angioscope makes it safe and visible when the ablation is performed to carotid atherosclerotic plaques. The Ho:YAG laser and TFL are effective and safe for ablating the plaque .
PubMed: 36299568
DOI: 10.3389/fsurg.2022.937492 -
Surgical Neurology International 2022A neuroendoscope is a technical advance that allows surgeons to visualize certain regions of the brain that was previously inaccessible through the use of a surgical...
BACKGROUND
A neuroendoscope is a technical advance that allows surgeons to visualize certain regions of the brain that was previously inaccessible through the use of a surgical microscope. Several neuroendoscope designs have been implemented by other neurosurgeons over the past 5 years. The advantage of a neuroendoscope is the addition of a flexible and narrow tip that allows for safe entry into intracranial structures for clinical observation. However, there are some limitations to this approach. Here, we report the use of a modified angioscope as a newly developed neuroendoscope to be employed in observing intracranial structures.
METHODS
We report the use of an angioscope that is 1.8 mm in diameter and has both a thin and flexible tip. In this study, the angioscope was inserted into the lumen of an aspirator tube, and the tip of the device was placed at the intracranial area of intended observation area. Image findings were evaluated using an established goat brain model.
RESULTS
The angioscope was light in weight and maneuverable and could be reached and observed in the blind spot using a surgical microscope. From the cerebellopontine angle, the lower cranial nerves and trigeminal nerve could be observed, and from the cisterna magna, the floor of the fourth ventricle and the aqueduct could be seen.
CONCLUSION
The angioscope is a useful instrument to observe intracranial locations safely and effectively even within a limited surgical field. Further modifications will be required to use the angioscope in various craniotomy procedures.
PubMed: 36324912
DOI: 10.25259/SNI_748_2022 -
Journal of the American College of... May 2006The goal of this study was to use angioscopy to investigate the amount of neointimal coverage after sirolimus-eluting stent (SES) implantation. (Comparative Study)
Comparative Study Review
OBJECTIVES
The goal of this study was to use angioscopy to investigate the amount of neointimal coverage after sirolimus-eluting stent (SES) implantation.
BACKGROUND
Sirolimus-eluting stents reduce intimal hyperplasia.
METHODS
We used angioscopy to evaluate 37 consecutive stented coronary artery lesions (15 SES and 22 bare-metal stents [BMS]) in 25 patients (18 men, 7 women) at 3 to 6 months after stent implantation. Angioscopic evaluation focused on: 1) neointimal coverage of stent struts, and 2) the existence of thrombi. The degree of neointimal coverage was classified as grade 0 when there was no neointimal coverage (similar to immediately after the implantation); grade 1 when stent struts bulged into the lumen, but were covered and still translucently visible; grade 2 when stent struts were visible but not clearly seen (not translucent); and grade 3 when stent struts were not visible because they were embedded in the neointima.
RESULTS
Thrombi were identified in eight stented segments, tended to be more common with SES (p = 0.14), but were not seen on angiography. Three of the 15 SES (20%) had grade 0 neointimal coverage, and only 2 SES (13.3%) had complete coverage (grades 2/3). In contrast, all 22 BMS showed complete intimal coverage (grades 2/3). Thrombi were more common in stents with incomplete neointimal coverage (p = 0.09).
CONCLUSIONS
The SES had incomplete neointimal coverage three to six months after implantation, and this was associated with subclinical thrombus formation.
Topics: Aged; Angioscopy; Blood Vessel Prosthesis Implantation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Delayed-Action Preparations; Female; Humans; Hyperplasia; Immunosuppressive Agents; Male; Middle Aged; Sirolimus; Stents; Tunica Intima; Wound Healing
PubMed: 16697331
DOI: 10.1016/j.jacc.2005.11.092 -
Journal of the American College of... Jun 2018Spontaneous ruptured aortic plaques (SRAP), which might cause atheromatous embolization, are thought to be mainly iatrogenic and have not been observed directly.
BACKGROUND
Spontaneous ruptured aortic plaques (SRAP), which might cause atheromatous embolization, are thought to be mainly iatrogenic and have not been observed directly.
OBJECTIVES
The purpose of this study was to clarify the incidence, types, and dimensions of SRAP using angioscopy.
METHODS
In a cross-sectional study, 324 consecutive patients diagnosed with or suspected of having coronary artery disease were subjected to intra-aortic scans with nonobstructive angioscopy. Samples of SRAP were taken from the aorta. The dimensions of cholesterol crystals of atheromatous materials were measured with a polarizing microscope and compared with those of the ghost images of cholesterol crystals.
RESULTS
SRAP were detected in 262 patients (80.9%); 120 of 262 patients had ruptured aortic plaques below the diaphragmatic level. Samples were successfully obtained from 96 patients. The detected numbers of atheromatous material, fibrin, macrophage, and calcification were 237 (49.1%), 244 (50.6%), 111 (23.0%), and 127 (26.3%) out of 482 samples, respectively. The median lengths and widths of the sampled plaques were 254 μm (interquartile range [IQR]: 100 to 685 μm) and 148 μm (IQR: 535 to 423.5 μm), respectively. The lengths and widths of the cholesterol crystals isolated from atheromatous materials were 40 μm (IQR: 32.7 to 53.7 μm), and 30 μm (IQR: 23 to 38 μm), respectively, compared with the respective dimensions of the ghost images of 86 μm (IQR: 53 to 119) and 13 μm (IQR: 7 to 18 μm). No embolic symptoms were observed within 24 h of general care via cardiac catheterization.
CONCLUSIONS
SRAP are commonly scattered, and their dimensions were smaller than previously recognized. (Detecting Ruptured Aortic Plaques by Nonobstructive Angioscopy; UMIN000029772).
Topics: Aged; Aged, 80 and over; Angioscopy; Aorta; Aortic Diseases; Cholesterol; Cross-Sectional Studies; Female; Humans; Incidence; Japan; Male; Middle Aged; Plaque, Atherosclerotic; Rupture, Spontaneous
PubMed: 29929612
DOI: 10.1016/j.jacc.2018.03.539 -
Annals of Surgery Sep 1985In this study, the development of intraoperative angioscopy, the value of the information obtained, and the problems encountered with the procedure are reported. Eight...
In this study, the development of intraoperative angioscopy, the value of the information obtained, and the problems encountered with the procedure are reported. Eight angioscopes, 1.5 to 2.8 mm in diameter, with a line resolution of greater than 0.4 mm at 5 mm, were used. One-hundred ten angioscopic investigations were performed in 46 patients; 24 at peripheral bypass surgery and 22 at coronary artery bypass surgery. These included 68 arteries, 28 new anastomoses, six old grafts, five laser angioplasties, and three in situ vein grafts. The most important finding was that angioscopic data provide information not available from probes or angiography. Angioscopic findings were responsible for a change in surgical procedures in 12 patients (26%) including three anastomotic revisions, three alterations in graft site placement, and two repeat thrombectomies. The most significant technical problems were lack of steerability and insufficient irrigation, which resulted in poor angiographic images. Further technical development is necessary before routine intraoperative angioscopy is practical. Nevertheless, if these problems are resolved, angioscopy will provide unique, high-resolution information which can directly alter surgical therapy.
Topics: Angioplasty, Balloon; Arteriovenous Shunt, Surgical; Coronary Artery Bypass; Coronary Disease; Embolism; Endoscopy; Fiber Optic Technology; Humans; Intraoperative Period; Laser Therapy; Postoperative Complications; Suture Techniques; Vascular Surgical Procedures; Videotape Recording
PubMed: 2931056
DOI: 10.1097/00000658-198509000-00018 -
JACC. Cardiovascular Imaging Nov 2010
Topics: Angioscopes; Angioscopy; Animals; Atherosclerosis; Equipment Design; Humans; Magnetic Resonance Angiography; Magnetic Resonance Imaging, Interventional; Predictive Value of Tests
PubMed: 21071005
DOI: 10.1016/j.jcmg.2010.09.007 -
Circulation Journal : Official Journal... Jul 2021
Topics: Angioscopy; Humans; Plaque, Atherosclerotic
PubMed: 34039837
DOI: 10.1253/circj.CJ-21-0102 -
Journal of Cardiology Jul 2022The plaques with higher grade of yellow color by angioscopy are reported to be associated with vulnerability leading to adverse outcomes in coronary artery diseases....
BACKGROUND
The plaques with higher grade of yellow color by angioscopy are reported to be associated with vulnerability leading to adverse outcomes in coronary artery diseases. However, no studies have been performed for peripheral artery disease (PAD). We aimed to evaluate the relationship of angioscopic findings of peripheral arteries with the long-term prognosis.
METHODS
Angioscopy of iliac or femoropopliteal artery was performed before endovascular therapy in patients with PAD. The local plaque color and presence of thrombus were evaluated. Multivariable Cox regression models were used to estimate hazard ratio (HR) for all-cause mortality or major adverse cardiovascular event (MACE) related to the plaque colors as well as presence of thrombus.
RESULTS
Among 67 patients, 49.3% had intensive yellow plaques (group H) and the rest had light yellow to yellow ones (group L). Thrombus was detected in 74.6% of the patients and the presence was not different between the two groups. In Kaplan-Meier analysis during a median follow-up of 976 days and 757 days, group H showed increased mortality and MACE compared with group L (p <0.01 for both). Multivariable analysis demonstrated that the intensive yellow color of plaque was independently associated with mortality and MACE [HR: 11.48, 95% confidence interval (CI): 2.19-211.1 and HR: 3.81, 95% CI: 1.36-13.48, respectively] after adjusting for the presence of thrombus.
CONCLUSIONS
The yellow color intensity in local plaques by angioscopy may be a novel predictor of long-term prognosis in patients with PAD, regardless of the presence of thrombus.
Topics: Angioscopy; Coronary Artery Disease; Coronary Vessels; Humans; Peripheral Arterial Disease; Plaque, Atherosclerotic; Prognosis
PubMed: 35219551
DOI: 10.1016/j.jjcc.2022.02.004 -
Cureus Jan 2024Background Cholesterol crystals (CCs) are related to innate inflammation in spontaneously ruptured aortic plaques (SRAPs), and variability exists in the CCs and...
Background Cholesterol crystals (CCs) are related to innate inflammation in spontaneously ruptured aortic plaques (SRAPs), and variability exists in the CCs and interleukin (IL)-6 ratio in SRAPs. Methods The prevalence of scattering-type ruptures that glittered against the light of angioscopic fibers (puff-chandelier ruptures) and those that did not (puff ruptures) was analyzed in 848 patients with suspected coronary artery disease. Overall, 177 puff-chandelier ruptures and 105 puff ruptures were sampled using nonobstructive general angioscopy (NOGA). The sampled plaques were analyzed by direct detection of CCs with polarized light microscopy. The characteristics of the plaque fragments from puff and puff-chandelier ruptures were compared. The Interleukin-6 (IL-6) ratios were calculated for 100 puff-chandelier ruptures and 100 puff ruptures. Results CCs were detected in 54% of puff-chandelier ruptures and 20% of puff ruptures. The longer and shorter dimensions of the puff ruptures were smaller than those of the puff-chandelier ruptures. CCs were more prevalent in puff chandeliers than in puff ruptures (54% vs. 20%, respectively; p<0.0001). The number of CCs was higher in puff chandeliers than in puff ruptures with CCs (median 12,727 (interquartile range (IQR) 3,636-25,909)/10 mL vs. median 3,182 ( IQR 909-9,318)/10 mL) in CC-positive samples (p=0.0120). The IL-6 ratio of puff-chandelier ruptures was higher than that of puff ruptures (p=0.0014). Conclusions Examination of plaque fragments from puff-chandelier and puff ruptures revealed a higher prevalence of CCs in puff-chandelier ruptures compared to puff ruptures. Puff chandeliers exhibited a significantly greater number of CCs, suggesting a potential correlation with inflammatory levels. The IL-6 ratio was also higher in puff-chandelier ruptures. Direct detection of CCs and hematoxylin and eosin staining for SRAPs demonstrated variations in CC degree and dimensions between puff-chandelier and puff ruptures. Puff-chandelier ruptures exhibited more CCs associated with innate inflammation and larger fragments than puff ruptures. NOGA proved effective in detecting diverse characteristics and inflammation levels, as indicated by IL-6, in scattering-type SRAPs.
PubMed: 38274622
DOI: 10.7759/cureus.52949 -
Neurosurgery Aug 2014Endoluminal optical imaging, or angioscopy, has not seen widespread application during neurointerventional procedures, largely as a result of the poor imaging resolution...
BACKGROUND
Endoluminal optical imaging, or angioscopy, has not seen widespread application during neurointerventional procedures, largely as a result of the poor imaging resolution of existing angioscopes. Scanning fiber endoscopes (SFEs) are a novel endoscopic platform that allows high-resolution video imaging in an ultraminiature form factor that is compatible with currently used distal access endoluminal catheters.
OBJECTIVE
To test the feasibility and potential utility of high-resolution angioscopy with an SFE during common endovascular neurosurgical procedures.
METHODS
A 3.7-French SFE was used in a porcine model system to image endothelial disruption, ischemic stroke and mechanical thrombectomy, aneurysm coiling, and flow-diverting stent placement.
RESULTS
High-resolution, video-rate imaging was shown to be possible during all of the common procedures tested and provided information that was complementary to standard fluoroscopic imaging. SFE angioscopy was able to assess novel factors such as aneurysm base coverage fraction and side branch patency, which have previously not been possible to determine with conventional angiography.
CONCLUSION
Endovascular imaging with an SFE provides important information on factors that cannot be assessed fluoroscopically and is a novel platform on which future neurointerventional techniques may be based because it allows for periprocedural inspection of the integrity of the vascular system and the deployed devices. In addition, it may be of diagnostic use for inspecting the vascular wall and postprocedure device evaluation.
Topics: Angioscopy; Animals; Disease Models, Animal; Endoscopy; Feasibility Studies; Neurosurgical Procedures; Stroke; Swine
PubMed: 24762703
DOI: 10.1227/NEU.0000000000000383