The European Respiratory Journal Jul 2016
Topics: Exercise; Humans; Polysomnography; Sleep Apnea Syndromes; Sleep Apnea, Obstructive
PubMed: 27365507
DOI: 10.1183/13993003.00797-2016 -
Acta Otorhinolaryngologica Italica :... Dec 2017Obstructive sleep apnoea (OSAS) is an underdiagnosed chronic disease with a high prevalence in adults. It is becoming a significant social problem, since it is... (Review)
Review
Obstructive sleep apnoea (OSAS) is an underdiagnosed chronic disease with a high prevalence in adults. It is becoming a significant social problem, since it is associated with a worsening in quality of life and increase in mortality. The cost-effectiveness ratio of diagnostic and therapeutic management of OSAS is a strategic issue to counteract the expected increasing demand of objective testing. OSAS patients with any clinical evidence of comorbidities must be studied using simplified and less expensive systems such as Home Sleep Testing (HST). On the other hand, Sleep Laboratory Polysomnography (PSG) is the gold standard to manage OSAS patients with comorbidities. It should be pointed out that the use of HST can lead to incorrect diagnosis in poorly selected OSAS subjects. This short review discusses various topics for the proper diagnosis and treatment of OSAS in view of epidemiological factors and results in terms of costs and social benefit of the disease. Whatever the strategy chosen and/or the organisational model adopted for managing OSAS, it cannot and should not take into account only cost-effectiveness. Long-term prospective studies evaluating cost-effectiveness ratios and outcomes of OSAS treatment of hospital management models versus home care models are needed.
Topics: Cost-Benefit Analysis; Humans; Models, Theoretical; Polysomnography; Sleep Apnea, Obstructive
PubMed: 28663598
DOI: 10.14639/0392-100X-1520 -
Respirology (Carlton, Vic.) Feb 2017Heart failure (HF) and sleep apnoea are common disorders which frequently coexist. Two main types of apnoea occur: one is obstructive which, through recurring episodes... (Review)
Review
Heart failure (HF) and sleep apnoea are common disorders which frequently coexist. Two main types of apnoea occur: one is obstructive which, through recurring episodes of snoring, hypoxaemia, large negative intra-thoracic pressures and arousals from sleep leading to downstream inflammatory and autonomic nervous system changes, is thought to be a causative factor to the development of systemic hypertension and HF. The other type of apnoea, Cheyne-Stokes respiration with central sleep apnoea (CSR-CSA), is characterized by an oscillatory pattern of ventilation with a prevailing hyperventilation-induced hypocapnia, often in the absence of significant hypoxaemia and snoring, and is thought to be a consequence of advanced HF-related low cardiac output, high sympathetic nervous system activation and pulmonary congestion. CSR-CSA may be a compensatory response to advanced HF. Rostral fluid shift during sleep may play an important role in the pathogenesis of both obstructive sleep apnoea (OSA) and CSA. Studies of positive airway pressure (PAP) treatment of OSA and CSA in HF have shown short-term improvements in cardiac and autonomic function; however, there is no evidence of improved survival. Loop gain may provide useful marker of continuous PAP (CPAP) responsiveness in patients with central apnoea. A greater understanding of the pathophysiology of the interaction between obstructive and central apnoea and the various types of HF, and the mechanisms of therapies, such as PAP, is required to develop new strategies to overcome the disabling symptoms, and perhaps improve the mortality, that accompany HF with sleep apnoea.
Topics: Cheyne-Stokes Respiration; Continuous Positive Airway Pressure; Heart Failure; Humans; Sleep Apnea, Central; Sleep Apnea, Obstructive
PubMed: 27998040
DOI: 10.1111/resp.12964 -
The European Respiratory Journal May 2021
Topics: Humans; Sleep Apnea Syndromes; Sleep Apnea, Obstructive
PubMed: 33958377
DOI: 10.1183/13993003.04644-2020 -
Current Heart Failure Reports Oct 2016The majority of patients with heart failure have sleep-disordered breathing (SDB)-with central (rather than obstructive) sleep apnoea becoming the predominant form in... (Review)
Review
The majority of patients with heart failure have sleep-disordered breathing (SDB)-with central (rather than obstructive) sleep apnoea becoming the predominant form in those with more severe disease. Cyclical apnoeas and hypopnoeas are associated with sleep disturbance, hypoxaemia, haemodynamic changes, and sympathetic activation. Such patients have a worse prognosis than those without SDB. Mask-based therapies of positive airway pressure targeted at SDB can improve measures of sleep quality and partially normalise the sleep and respiratory physiology, but recent randomised trials of cardiovascular outcomes in central sleep apnoea have been neutral or suggested the possibility of harm, likely from increased sudden death. Further randomised outcome studies (with cardiovascular mortality and hospitalisation endpoints) are required to determine whether mask-based treatment for SDB is appropriate for patients with chronic systolic heart failure and obstructive sleep apnoea, for those with heart failure with preserved ejection fraction, and for those with decompensated heart failure. New therapies for sleep apnoea-such as implantable phrenic nerve stimulators-also require robust assessment. No longer can the surrogate endpoints of improvement in respiratory and sleep metrics be taken as adequate therapeutic outcome measures in patients with heart failure and sleep apnoea.
Topics: Cardiovascular System; Heart Failure; Heart Failure, Systolic; Hemodynamics; Humans; Prognosis; Randomized Controlled Trials as Topic; Sleep Apnea Syndromes; Sleep Apnea, Central; Sleep Apnea, Obstructive
PubMed: 27640202
DOI: 10.1007/s11897-016-0304-x -
Circulation Journal : Official Journal... Jun 2017Sleep-disordered breathing (SDB) occurs in approximately 50% of patients with reduced left ventricular ejection fraction receiving contemporary heart failure (HF)... (Review)
Review
Sleep-disordered breathing (SDB) occurs in approximately 50% of patients with reduced left ventricular ejection fraction receiving contemporary heart failure (HF) therapies. Obstructive (OSA) and central sleep apneas (CSA) interrupt breathing by different mechanisms but impose qualitatively similar autonomic, chemical, mechanical, and inflammatory burdens on the heart and circulation. Because contemporary evidence-based drug and device HF therapies have little or no mitigating effect on the acute or long-term consequences of such stimuli, there is a sound mechanistic rationale for targeting SDB to reduce cardiovascular event rates and prolong life. However, the promise of observational studies and randomized trials of small size and duration describing a beneficial effect of treating SDB in HF via positive airway pressure was not realized in 2 recent randomized outcome-driven trials: SAVE, which evaluated the cardiovascular effect of treating OSA in a cohort without HF, and SERVE-HF, which reported the results of a strategy of random allocation of minute-ventilation-triggered adaptive servo-ventilation (ASV) for HF patients with CSA. Whether effective treatment of either OSA or CSA improves the HF trajectory by reducing cardiovascular morbidity or mortality has yet to be definitively established. ADVENT-HF, designed to determine the effect of treating both CSA and non-sleepy OSA HF patients with a peak-airflow triggered ASV algorithm, could resolve this present clinical equipoise concerning the treatment of SDB.
Topics: Heart Failure; Humans; Mortality; Observational Studies as Topic; Randomized Controlled Trials as Topic; Sleep Apnea, Central; Sleep Apnea, Obstructive
PubMed: 28539541
DOI: 10.1253/circj.CJ-17-0440 -
Neurocritical Care Apr 2021Apnea is one of the three cardinal findings in brain death (BD). Apnea testing (AT) is physiologically and practically complex. We sought to review described... (Review)
Review
Apnea is one of the three cardinal findings in brain death (BD). Apnea testing (AT) is physiologically and practically complex. We sought to review described modifications of AT, safety and complication rates, monitoring techniques, performance of AT on extracorporeal membrane oxygenation (ECMO), and other relevant considerations regarding AT. We conducted a systematic scoping review to answer these questions by searching the literature on AT in English language available in PubMed or EMBASE since 1980. Pediatric or animal studies were excluded. A total of 87 articles matched our inclusion criteria and were qualitatively synthesized in this review. A large body of the literature on AT since its inception addresses a variety of modifications, monitoring techniques, complication rates, ways to perform AT on ECMO, and other considerations such as variability in protocols, lack of uniform awareness, and legal considerations. Only some modifications are widely used, especially methods to maintain oxygenation, and most are not standardized or endorsed by brain death guidelines. Future updates to AT protocols and strive for unification of such protocols are desirable.
Topics: Apnea; Brain Death; Extracorporeal Membrane Oxygenation; Humans
PubMed: 32524528
DOI: 10.1007/s12028-020-01015-0 -
Sensors (Basel, Switzerland) Dec 2020We propose an unobtrusive, wearable, and wireless system for the pre-screening and follow-up in the domestic environment of specific sleep-related breathing disorders....
We propose an unobtrusive, wearable, and wireless system for the pre-screening and follow-up in the domestic environment of specific sleep-related breathing disorders. This group of diseases manifests with episodes of apnea and hypopnea of central or obstructive origin, and it can be disabling, with several drawbacks that interfere in the daily patient life. The gold standard for their diagnosis and grading is polysomnography, which is a time-consuming, scarcely available test with many wired electrodes disseminated on the body, requiring hospitalization and long waiting times. It is limited by the night-by-night variability of sleep disorders, while inevitably causing sleep alteration and fragmentation itself. For these reasons, only a small percentage of patients achieve a definitive diagnosis and are followed-up. Our device integrates photoplethysmography, an accelerometer, a microcontroller, and a bluetooth transmission unit. It acquires data during the whole night and transmits to a PC for off-line processing. It is positioned on the nasal septum and detects apnea episodes using the modulation of the photoplethysmography signal during the breath. In those time intervals where the photoplethysmography is detecting an apnea, the accelerometer discriminates obstructive from central type thanks to its excellent sensitivity to thoraco-abdominal movements. Tests were performed on a hospitalized patient wearing our integrated system and the type III home sleep apnea testing recommended by The American Academy of Sleep Medicine. Results are encouraging: sensitivity and precision around 90% were achieved in detecting more than 500 apnea episodes. Least thoraco-abdominal movements and body position were successfully classified in lying down control subjects, paving the way toward apnea type classification.
Topics: Humans; Polysomnography; Sleep; Sleep Apnea Syndromes; Sleep Apnea, Obstructive; Wearable Electronic Devices
PubMed: 33302407
DOI: 10.3390/s20247014 -
Computer Methods and Programs in... Nov 2022Apnea of prematurity is one of the most common diagnosis in neonatal intensive care units. Apneas can be classified as central, obstructive or mixed. According to the...
BACKGROUND AND OBJECTIVE
Apnea of prematurity is one of the most common diagnosis in neonatal intensive care units. Apneas can be classified as central, obstructive or mixed. According to the current international standards, minimal fluctuations or absence of fluctuations in the chest impedance (CI) suggest a central apnea (CA). However, automatic detection of reduced CI fluctuations leads to a high number of central apnea-suspected events (CASEs), the majority being false alarms. We aim to improve automatic detection of CAs by using machine learning to optimize detection of CAs among CASEs.
METHODS
Using an optimized algorithm for automated detection, all CASEs were detected in a population of 10 premature infants developing late-onset sepsis and 10 age-matched control patients. CASEs were inspected by two clinical experts and annotated as CAs or rejections in two rounds of annotations. A total of 47 features were extracted from the ECG, CI and oxygen saturation signals considering four 30 s-long moving windows, from 30 s before to 15 s after the onset of each CASE, using a moving step size of 5 s. Consecutively, new CA detection models were developed based on logistic regression with elastic net penalty, random forest and support vector machines. Performance was evaluated using both leave-one-patient-out and 10-fold cross-validation considering the mean area under the receiver-operating-characteristic curve (AUROC).
RESULTS
The CA detection model based on logistic regression with elastic net penalty returned the highest mean AUROC when features extracted from all four time windows were included, both using leave-one-patient-out and 10-fold cross-validation (mean AUROC of 0.88 and 0.90, respectively). Feature relevance was found to be the highest for features derived from the CI. A threshold for the false positive rate in the mean receiver-operating-characteristic curve equal to 0.3 led to a high percentage of correct detections for all CAs (78.2%) and even higher for CAs followed by a bradycardia (93.4%) and CAs followed by both a bradycardia and a desaturation (95.2%), which are more critical for the well-being of premature infants.
CONCLUSIONS
Models based on machine learning can lead to improved CA detection with fewer false alarms.
Topics: Infant, Newborn; Infant; Humans; Apnea; Sleep Apnea, Central; Bradycardia; Infant, Premature; Machine Learning
PubMed: 36215858
DOI: 10.1016/j.cmpb.2022.107155 -
Journal of Clinical Sleep Medicine :... Jul 2020Thermistors, nasal cannulas, and respiratory inductance plethysmography (RIP) are the recommended reference sensors of the American Academy of Sleep Medicine (AASM) for...
STUDY OBJECTIVES
Thermistors, nasal cannulas, and respiratory inductance plethysmography (RIP) are the recommended reference sensors of the American Academy of Sleep Medicine (AASM) for the detection and characterization of apneas and hypopneas; however, these sensors are not well tolerated by patients and have poor scorability. We evaluated the performance of an alternative method using a combination of tracheal sounds (TSs) and RIP signals.
METHODS
Consecutive recordings of 70 adult patients from the Pays de la Loire Sleep Cohort were manually scored in random order using the AASM standard signals and the combination TS and RIP signals, without respiratory sensors placed on the patient's face. The TS-RIP scoring used the TS and RIP-flow signals for detection of apneas and hypopneas, respectively, and the suprasternal pressure and RIP belt signals for the characterization of apneas.
RESULTS
Sensitivity and specificity of the TS-RIP combination were 96.21% and 91.34% for apnea detection and 89.94% and 93.25% for detecting hypopneas, respectively, with a kappa coefficient of 0.87. For the characterization of apneas, sensitivity and specificity were 98.67% and 96.17% for obstructive apneas, 92.66% and 99.36% for mixed apneas, and 96.14% and 98.89% for central apneas, respectively, with a kappa coefficient of 0.94. The TS-RIP scoring revealed a high agreement for classifying obstructive sleep apnea into severity classes (none, mild, moderate, and severe obstructive sleep apnea) with a Cohen's kappa coefficient of 0.96.
CONCLUSIONS
Compared with the AASM reference sensors, the TS-RIP combination allows reliable noninvasive detection and characterization of respiratory events with a high degree of sensitivity and specificity. TS-RIP combination could be used for diagnosis of obstructive sleep apnea in adults, either as an alternative to the AASM sensors or in combination with the recommended AASM sensors.
Topics: Adult; Humans; Plethysmography; Polysomnography; Sleep; Sleep Apnea Syndromes; Sleep Apnea, Obstructive
PubMed: 32267226
DOI: 10.5664/jcsm.8460