-
European Journal of Dentistry May 2024Conventional glass ionomer cements (GICs) have been considered the most prevalent restorative material however; the reduced mechanical qualities and decreased wear...
OBJECTIVES
Conventional glass ionomer cements (GICs) have been considered the most prevalent restorative material however; the reduced mechanical qualities and decreased wear resistance have been the main challenges facing their wide clinical application. This study was designed to assess the mechanical properties of fluorinated graphene (FG) oxide-modified conventional GIC.
MATERIALS AND METHODS
Composites of FG/GIC samples were prepared using (Medifil from PROMEDICA, Germany, shade A3) at different concentrations (0wt%) control group and (1wt%, 2wt% and 3wt% FG) groups using cylindrical molds (3mm × 6mm). FG was prepared using hydrothermal technique and characterized using XPERT-PRO Powder Diffractometer system for X-ray diffraction analysis and JEOL JEM-2100 high resolution transmission electron microscope. Vickers' hardness and wear resistance of GI samples were measured. Mechanical abrasion was performed via three-body tooth brushing wear test using ROBOTA chewing simulator coupled with a thermocycling protocol (Model ACH-09075DC-T, AD-Tech Technology Co., Ltd., Leinfelden-Echterdingen, Germany).
STATISTICAL ANALYSIS
Comparisons between groups with respect to normally distributed numeric variables were performed using one-way analysis of variance test followed by posthoc test. While paired -test was utilized for comparing data within the same group.
RESULTS
The surface roughness values of GICs (1wt% FG) and (2wt% FG) composites were significantly lower than those of the control and 3wt%FG groups. Vickers' hardness numbers were significantly higher in FG/GICs composites than in the control group (≤0.05).
CONCLUSION
GIC/FG combinations have sufficient strength to resist the occlusion stresses with improved hardness as compared with conventional GIC. GIC/FG appeared to be a promising restorative material.
PubMed: 38759994
DOI: 10.1055/s-0044-1785188 -
The Journal of Clinical Pediatric... May 2024This study evaluated the behavioural changes pertaining to children's oral health before and after the dental general anaesthesia (DGA), with particular focus on the...
This study evaluated the behavioural changes pertaining to children's oral health before and after the dental general anaesthesia (DGA), with particular focus on the factors associated with these changes. The records were collected for the children who received DGA from July 2015 to November 2016, and relevant questionnaires were obtained from their parents/guardians for the information prior to and after the DGA. The questionnaire included Early Childhood Oral Health Impact Scale (ECOHIS) and Dental Subscale of Children's Fear Survey Schedule (CFSS-DS) to investigate the changes in Oral Health-related Quality of Life (OHRQoL) and dental fear. The DGA impact on children's oral hygiene habits and oral health-related behaviours was assessed by analysing the data. The chi-square test and Mann-Whitney test were employed to evaluate the differences. Total of 141 patients (89 before DGA and 77 after DGA, 25 being common) participated in this study. There were 60 children below 5 years and 29 over 5 years before DGA, while 41 children below 5 years and 36 over 5 years after DGA. Most parents/guardians were educated above undergraduate level (59.6% before DGA, 55.8% after DGA). More children lived with grandparents (61.8% before DGA, 54.5% after DGA) than only with parents (20.2% before DGA, 26.0% after DGA). In total, 73.0% (65/89) children before DGA brushed teeth more than twice a day. This proportion increased to 90.9% after DGA (70/77, = 0.03). The eating difficulty decreased after DGA according to ECOHIS ( = 0.01). CFSS-DS score also decreased after DGA ( < 0.05). After DGA, children's oral hygiene habits and oral health-related quality of life (OHRQoL) improved, children fear for dental treatment decreased, and parents became more attentive towards children oral health.
Topics: Humans; Anesthesia, General; Oral Health; Female; Child, Preschool; Male; Anesthesia, Dental; Child; Quality of Life; Dental Care for Children; Oral Hygiene; Health Behavior; Child Behavior; Dental Anxiety; Surveys and Questionnaires
PubMed: 38755987
DOI: 10.22514/jocpd.2024.063 -
Kidney Diseases (Basel, Switzerland) Apr 2024Acute kidney injury (AKI) is kidney damage that leads to a rapid decline in function. AKI primarily occurs when the tubular epithelium is damaged, causing swelling, loss... (Review)
Review
BACKGROUND
Acute kidney injury (AKI) is kidney damage that leads to a rapid decline in function. AKI primarily occurs when the tubular epithelium is damaged, causing swelling, loss of brush margin, and eventual apoptosis. Research has shown that tubular epithelial cell damage in AKI is linked to cell cycle arrest, autophagy, and regulation of cell death.
SUMMARY
Pyroptosis, a type of programmed cell death triggered by inflammation, is believed to play a role in the pathophysiology of AKI. Cumulative evidence has shown that pyroptosis is the main cause of tubular cell death in AKI. Thus, targeted intervention of pyroptosis may be a promising therapeutic approach for AKI. This review delves deep into the cutting-edge research surrounding pyroptosis in the context of AKI, shedding light on its intricate mechanisms and potential implications for clinical practice. Additionally, we explore the exciting realm of potential preclinical treatment options for AKI, aiming to pave the way for future therapeutic advancements.
KEY MESSAGES
Pyroptosis, a highly regulated form of cell death, plays a crucial role in determining the fate of cells during the development of AKI. This intricate process involves the activation of inflammasomes, which are multi-protein complexes that initiate pyroptotic cell death. By understanding the mechanisms underlying pyroptosis, researchers aim to gain insights into the pathogenesis of AKI and potentially identify new therapeutic targets for this condition.
PubMed: 38751798
DOI: 10.1159/000535894 -
BioRxiv : the Preprint Server For... May 2024Lubricin, a lubricating glycoprotein abundant in synovial fluid, forms a low-friction brush polymer interface in tissues exposed to sliding motion including joints,...
Lubricin, a lubricating glycoprotein abundant in synovial fluid, forms a low-friction brush polymer interface in tissues exposed to sliding motion including joints, tendon sheaths, and the surface of the eye. Despite its therapeutic potential in diseases such as osteoarthritis and dry eye disease, there are few sources available. Through rational design, we developed a series of recombinant lubricin analogs that utilize the species-specific tissue-binding domains at the N- and C-termini to increase biocompatibility while replacing the central mucin domain with an engineered variant that retains the lubricating properties of native lubricin. In this study, we demonstrate the tissue binding capacity of our engineered lubricin product and its retention in the joint space of rats. Next, we present a new bioprocess chain that utilizes a human-derived cell line to produce -glycosylation consistent with that of native lubricin and a purification strategy that capitalizes on the positively charged, hydrophobic N- and C-terminal domains. The bioprocess chain is demonstrated at 10 L scale in industry-standard equipment utilizing commonly available ion exchange, hydrophobic interaction and size exclusion chromatography resins. Finally, we confirmed the purity and lubricating properties of the recombinant biolubricant. The biomolecular engineering and bioprocessing strategies presented here are an effective means of lubricin production and could have broad applications to the study of mucins in general.
PubMed: 38746339
DOI: 10.1101/2024.05.05.592580 -
BMC Oral Health May 2024Our study aimed to evaluate the long-term concordance and acceptance when using powered devices for everyday oral hygiene routine and gingival health in patients showing... (Clinical Trial)
Clinical Trial
PURPOSE
Our study aimed to evaluate the long-term concordance and acceptance when using powered devices for everyday oral hygiene routine and gingival health in patients showing papillary bleeding.
PATIENTS AND METHODS
Thirty-one participants were recruited at the dental clinic of the University Hospital of Cologne, Germany, over a 6-week duration. At baseline, a standard dental check-up was performed, including oral hygiene indices and documentation of oral hygiene devices used. The study consisted of two consecutive phases: the first (motivational trial) was designed to prove the effectiveness and safety of a microdroplet device and a powered toothbrush compared to dental floss and a manual toothbrush over a period of 4 weeks. The second (observational) phase began with all participants receiving the powered oral homecare devices. Participants were able to use their oral hygiene measures of choice over an unsupervised period of 1 year. All participants were then rescheduled for a routine dental check-up, where oral hygiene indices and oral hygiene devices used were reevaluated.
RESULTS
After 1 year, 93.3% of participants stated they performed interdental cleaning on a regular basis (baseline 60.0%). The percentage using a powered toothbrush increased from 41.9% (baseline) to 90.0% after 1 year. Oral hygiene parameters had improved after both the motivational trial and observational phases compared to baseline (papillary bleeding index p = .000; Rustogi Modified Navy Plaque Index p < .05; Quigley-Hein Index p = .000).
CONCLUSION
In the long term, participants preferred using powered oral hygiene devices over the gold standard dental floss and manual toothbrush. Improved oral hygiene parameters after 1 year may indicate implementation of newly acquired oral-hygiene skills during the 4-week instruction phase.
Topics: Humans; Male; Female; Oral Hygiene; Adult; Toothbrushing; Longitudinal Studies; Middle Aged; Dental Devices, Home Care; Periodontal Index; Oral Hygiene Index; Aged; Gingivitis
PubMed: 38745286
DOI: 10.1186/s12903-024-04313-7 -
Journal of Respiratory Biology and... Mar 2024Released mitochondrial DNA (mtDNA) in cells activates cGAS-STING pathway, which induces expression of interferon-stimulated genes (ISGs) and thereby promotes...
Released mitochondrial DNA (mtDNA) in cells activates cGAS-STING pathway, which induces expression of interferon-stimulated genes (ISGs) and thereby promotes inflammation, as frequently seen in asthmatic airways. However, whether the genetic determinant, Gasdermin B (GSDMB), the most replicated asthma risk gene, regulates this pathway remains unknown. We set out to determine whether and how GSDMB regulates mtDNA-activated cGAS-STING pathway and subsequent induction in human airway epithelial cells. Using qPCR, ELISA, native polyacrylamide gel electrophoresis, co-immunoprecipitation and immunofluorescence assays, we evaluated the regulation of GSDMB on cGAS-STING pathway in both BEAS-2B cells and primary normal human bronchial epithelial cells (nHBEs). mtDNA was extracted in plasma samples from human asthmatics and the correlation between mtDNA levels and eosinophil counts was analyzed. is significantly associated with expression in asthmatic nasal epithelial brushing samples from the Genes-environments and Admixture in Latino Americans (GALA) II study. Over-expression of promotes DNA-induced IFN and in bronchial epithelial BEAS-2B cells and nHBEs. Conversely, knockout of led to weakened induction of (IFNs) and in BEAS-2B cells. Mechanistically, GSDMB interacts with the C-terminus of STING, promoting the translocation of STING to Golgi, leading to the phosphorylation of IRF3 and induction of and . mtDNA copy number in serum from asthmatics was significantly correlated with blood eosinophil counts especially in male subjects. GSDMB promotes the activation of mtDNA and poly (dA:dT)-induced activation of cGAS-STING pathway in airway epithelial cells, leading to enhanced induction of
PubMed: 38737375
DOI: 10.35534/jrbtm.2024.10005 -
International Dental Journal May 2024The aim of this randomised clinical trial (RCT) was to assess the concentration of fluoride ions in saliva after applying fluoride gel and to examine the extent to which...
OBJECTIVE
The aim of this randomised clinical trial (RCT) was to assess the concentration of fluoride ions in saliva after applying fluoride gel and to examine the extent to which rinsing the mouth with water affects the content of fluoride ions in saliva as opposed to no rinsing after brushing teeth with gel.
METHODS
This single-blind RCT was conducted amongst a group of students (N = 103) and consisted of a questionnaire, clinical examination, saliva collection, and laboratory analysis. After saliva samples were collected, the students brushed their teeth for 2 minutes with Elmex Gelée (Colgate-Palmolive). Next, saliva was collected after 15 and 60 minutes from Group A (spitting out saliva after brushing) and from Group B (spitting out and rinsing with water after brushing). Statistical analysis was performed using a t test to compare the means between the groups.
RESULTS
Fifteen minutes after brushing, the level of fluoride increased in Group A about 15-fold to 15.33 ± 14.73 ppm and in Group B about 6-fold to 6.19 ± 5.97 ppm (P < .001). After 60 minutes, in Group A it decreased to 1.68 ± 0.83 ppm and in Group B to 0.60 ± 0.37 ppm (P < .001).
CONCLUSIONS
The use of fluoride gel in the absence of mouth rinsing produced significantly higher level and a concentration of fluoride in saliva. A post-gel brushing without rinsing might be suitable for patients at high risk for caries. Hence fruther research on the effect of a mouth rinse after use of fluoride gels is eesential to confirm our findings, and to promulgate evidence-based recommendations.
PubMed: 38734515
DOI: 10.1016/j.identj.2024.01.005 -
A New Sustainable PPT Coating Based on Recycled PET to Improve the Durability of Hydraulic Concrete.Polymers May 2024A new, sustainable polypropylene terephthalate (PPT) coating was synthesized from recycled polyethylene terephthalate (PET) and applied onto a hydraulic concrete...
A new, sustainable polypropylene terephthalate (PPT) coating was synthesized from recycled polyethylene terephthalate (PET) and applied onto a hydraulic concrete substrate to improve its durability. For the first step, PET bottle wastes were ground and depolymerized by glycolysis using propylene glycol (PG) in a vessel-type reactor (20-180 °C) to synthesize bis(2-hydroxypropyl)-terephthalate (BHPT), which was applied as a coating to one to three layers of hydraulic concrete substrate using the brushing technique and polymerized (150 °C for 15 h) to obtain PPT. PET, BHPT, and PPT were characterized by FT-IR, PET, and PPT using TGA, and the PPT coatings by SEM (thickness), ASTM-D3359-17 (adhesion), and water contact angle (wettability). The durability of hydraulic concrete coated with PPT was studied using resist chloride ion penetration (ASTM-C1202-17), carbonation depth at 28 days (RILEM-CPC-18), and the absorption water ratio (ASTM-C1585-20). The results demonstrated that the BHPT and PPT were synthetized (FT-IR), and PPT had a similar thermal behavior to PET (TGA); the PPT coatings had good adhesion to the substrate, with thicknesses of micrometric units. PPT coatings presented hydrophilic hydrophilic behavior like PET coatings, and the durability of hydraulic concrete coated with PPT (2-3 layers) improved (migration of chloride ions decreased, carbonation depth was negligible, and the absorption water ratio decreased).
PubMed: 38732766
DOI: 10.3390/polym16091297 -
Polymers Apr 2024In recent years, a great deal of work has been devoted to the development of thermoresponsive polymers that can be made into new types of smart materials. In this paper,...
In recent years, a great deal of work has been devoted to the development of thermoresponsive polymers that can be made into new types of smart materials. In this paper, a branched polymer, HTPB--(PNIPAM/PEG), with polyolefin chain segments as the backbone and having polyethylene glycol (PEG) and poly(N-isopropylacrylamide) (PNIPAM) as side chains was synthesized by ATRP and click reactions using N-HTPB-Br as the macroinitiator. This initiator was designed and synthesized using hydroxyl-terminated polybutadiene (HTPB) as the substrate. The temperature-responsive behavior of the branched polymer was investigated. The lower critical solution temperature (LCST) of the branched polymer was determined by ultraviolet and visible spectrophotometry (UV-vis) and was found to be 35.2 °C. The relationship between the diameter size of micelles and temperature was determined by dynamic light scattering (DLS). It was found that the diameter size changed at 36 °C, which was nearly consistent with the result obtained by UV-vis. The results of the study indicate that HTPB--(PNIPAM/PEG) is a temperature-responsive polymer. At room temperature, the polymer can self-assemble into composite micelles, with the main chain as the core and the branched chain as the shell. When the temperature was increased beyond LCST, the polyolefin main chain along with the PNIPAM branched chain assembled to form the nucleus, and the PEG branched chain constituted the shell.
PubMed: 38732717
DOI: 10.3390/polym16091248 -
Polymers Apr 2024Self-consistent field (SCF) theory serves as a robust tool for unraveling the intricate behavior exhibited by soft polymeric materials. However, the accuracy and...
Self-consistent field (SCF) theory serves as a robust tool for unraveling the intricate behavior exhibited by soft polymeric materials. However, the accuracy and efficiency of SCF calculations are crucially dependent on the numerical methods employed for system discretization and equation-solving. Here, we introduce a simple three dimensional SCF algorithm that uses real-space methods and adaptive discretization, offering improved accuracy and efficiency for simulating polymeric systems at surfaces. Our algorithm's efficacy is demonstrated through simulations of two distinct polymeric systems, namely, block copolymer (BCP) films and polymer brushes. By enhancing spatial resolution in regions influenced by external forces and employing finer contour discretization at grafting chain ends, we achieve significantly more accurate results at very little additional cost, enabling the study of 3D polymeric systems that were previously computationally challenging. To facilitate the widespread use of the algorithm, we have made our 1D-3D SCF code publicly available.
PubMed: 38732697
DOI: 10.3390/polym16091228