Dental Materials : Official Publication... Mar 2022Bulk-fill resin composites are a special group of restorative materials designed to reduce chair time needed to insert a direct composite restoration. However, other...
OBJECTIVE
Bulk-fill resin composites are a special group of restorative materials designed to reduce chair time needed to insert a direct composite restoration. However, other factors determine the clinical success of a restorative material. Clinically the major reasons for failure of direct restorations are secondary caries and fracture of the restoration or the tooth itself. In the long-term composite resin restorations in posterior teeth may be prone to wear. As bulk-fill materials have their own composition that will determine their mechanical properties, the wear resistance may be affected as well. The aim of this in vitro study was to evaluate the wear of bulk-fill composites in comparison with a conventional hybrid composite. The null hypothesis was that there are no differences between the four bulk-fill materials and one traditional highly filled nanohybrid composite for posterior use when subjected to a two-body wear rate test and hardness measurement.
METHODS
Four bulk-fill composites SDR Smart Dentin Replacement (SDR), X-tra base (XBA), FiltekBulk Fill (FUP), Dual-Curing Bulk Composite (FBFL) and conventional nanohybrid resin composite Grandio (GDO) subjected to a two-body wear test against a stainless steel (SS) antagonist wheel. Scanning Electron Microscopy analysis was performed to detect the surface alterations. Microhardness of all samples was tested (n = 5) with a Vickers diamond indenter (5 indentations in each specimen). One-way ANOVA and Tukey's post hoc test (P < 0.01) were used to analyze differences in wear values. The hardness data were submitted to one-way ANOVA test, followed by the Tukey post hoc test (α = 0.05). T-test was applied to compare wear rate in time interval between one day and one month.
RESULTS
The highest wear rate values were recorded for SDR and the lowest wear rate values were for GDO. Hardness was the highest for GDO and the lowest for FBFL.
SIGNIFICANCE
The bulk-fill composites have a higher wear rate and lower hardness than the conventional nanohybrid composite, making them less suitable for stress-bearing restorations.
Topics: Composite Resins; Dental Materials; Hardness; Materials Testing
PubMed: 34972580
DOI: 10.1016/j.dental.2021.12.138 -
Dental Materials : Official Publication... Aug 2017The objective of this project, which was initiated from the Academy of Dental Materials, was to review and critically appraise methods to determine fracture, deformation... (Review)
Review
OBJECTIVE
The objective of this project, which was initiated from the Academy of Dental Materials, was to review and critically appraise methods to determine fracture, deformation and wear resistance of dental resin composites, in an attempt to provide guidance for investigators endeavoring to study these properties for these materials.
METHODS
Test methods have been ranked in the priority of the specific property being tested, as well as of the specific test methods for evaluating that property. Focus was placed on the tests that are considered to be of the highest priority in terms of being the most useful, applicable, supported by the literature, and which show a correlation with clinical findings. Others are mentioned briefly for the purpose of being inclusive. When a standard test method exists, including those used in other fields, these have been identified in the beginning of each section. Also, some examples from the resin composite literature are included for each test method.
RESULTS
The properties for evaluating resin composites were ranked in the priority of measurement as following: (1) Strength, Elastic Modulus, Fracture toughness, Fatigue, Indentation Hardness, Wear-abrasion (third body) and Wear-attrition (contact/two body), (2) Toughness, Edge strength (chipping) and (3) Wear determined by toothbrush.
SIGNIFICANCE
The following guidance is meant to aid the researcher in choosing the proper method to assess key properties of dental resin composites with regard to their fracture, deformation and wear resistance.
Topics: Composite Resins; Dental Materials; Elastic Modulus; Hardness; Humans; Materials Testing; Surface Properties
PubMed: 28577893
DOI: 10.1016/j.dental.2017.04.013 -
Orthodontics & Craniofacial Research Aug 2022The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. (Review)
Review
OBJECTIVE
The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices.
MATERIALS AND METHODS
Five 3D printers (Ka:rv LP 550, Swinwon; "KAR"), (L120, Dazz 3D; "L12"), (MiiCraft 125, Miicraft Jena; "MIC"), (Slash 2, Uniz; "SLS") and (Pro 95, SprintRay; "PRO") were used to prepare orthodontic aligners with dental resin (Tera Harz TC-85DAW, Graphy). The central incisors of each aligner were cut, prepared and evaluated in terms of Martens-Hardness (HM), indentation-modulus (E ) and elastic-index (η ) as per ISO14577-1:2002. Force-indentation curves were recorded and differences among printers were checked with generalized linear regressions (alpha=5%).
RESULTS
Statistically significant differences were seen for all mechanical properties (P < .05), which were in descending order: HM (N/mm ) as median (Interquartile Range [IQR]): SLS 108.5 (106.0-112.0), L12 103.0 (102.0-107.0), KAR 101.5 (97.5-103.0), MIC 100.0 (97.5-101.5) and PRO 94.0 (93.0-96.0); E (MPa) as mean (Standard Deviation [SD]): SLS 2696.3 (124.7), L12 2627.8 (73.5), MIC 2566.2 (125.1), KAR 2565.0 (130.2) and PRO 2491.2 (53.3); and η (%) as median (IQR): SLS 32.8 (32.3-33.1), L12 31.6 (30.8-32.3), KAR 31.3 (30.9-31.9), MIC 30.5 (29.9-31.2) and PRO 29.5 (29.1-30.0). Additionally, significant differences existed between liquid crystal display (LCD) and digital light processing (DLP) printers for HM (P < .001), E (P = .002) and η (P < .001), with aligners from the former having higher values than aligners from the latter printer.
CONCLUSION
Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.
Topics: Hardness; Materials Testing; Printing, Three-Dimensional
PubMed: 34569692
DOI: 10.1111/ocr.12537 -
Dysphagia Feb 2015Texture modification has become one of the most common forms of intervention for dysphagia, and is widely considered important for promoting safe and efficient... (Review)
Review
Texture modification has become one of the most common forms of intervention for dysphagia, and is widely considered important for promoting safe and efficient swallowing. However, to date, there is no single convention with respect to the terminology used to describe levels of liquid thickening or food texture modification for clinical use. As a first step toward building a common taxonomy, a systematic review was undertaken to identify empirical evidence describing the impact of liquid consistency and food texture on swallowing behavior. A multi-engine search yielded 10,147 non-duplicate articles, which were screened for relevance. A team of ten international researchers collaborated to conduct full-text reviews for 488 of these articles, which met the study inclusion criteria. Of these, 36 articles were found to contain specific information comparing oral processing or swallowing behaviors for at least two liquid consistencies or food textures. Qualitative synthesis revealed two key trends with respect to the impact of thickening liquids on swallowing: thicker liquids reduce the risk of penetration-aspiration, but also increase the risk of post-swallow residue in the pharynx. The literature was insufficient to support the delineation of specific viscosity boundaries or other quantifiable material properties related to these clinical outcomes. With respect to food texture, the literature pointed to properties of hardness, cohesiveness, and slipperiness as being relevant both for physiological behaviors and bolus flow patterns. The literature suggests a need to classify food and fluid behavior in the context of the physiological processes involved in oral transport and flow initiation.
Topics: Deglutition; Food; Hardness; Humans; Risk Factors; Viscosity
PubMed: 25343878
DOI: 10.1007/s00455-014-9578-x -
Journal of Biomechanics Aug 2022Investigations into teeth mechanical properties provide insight into physiological functions and pathological changes. This study sought to 1) quantify the spatial...
Investigations into teeth mechanical properties provide insight into physiological functions and pathological changes. This study sought to 1) quantify the spatial distribution of elastic modulus, hardness and the microstructural features of dog dentin and to 2) investigate quantitative relationships between the mechanical properties and the complex microstructure of dog dentin. Maxillary canine teeth of 10 mature dogs were sectioned in the transverse and vertical planes, then tested using nanoindentation and scanning electron microscopy (SEM). Microstructural features (dentin area fraction and dentinal tubule density) and mechanical properties (elastic modulus and hardness) were quantified. Results demonstrated significant anisotropy and spatial variation in elastic modulus, hardness, dentin area fraction and tubule density. These spatial variations adhered to a consistent distribution pattern; hardness, elastic modulus and dentin area fraction generally decreased from superficial to deep dentin and from crown tip to base; tubule density generally increased from superficial to deep dentin. Poor to moderate correlations between microstructural features and mechanical properties (R = 0.032-0.466) were determined. The results of this study suggest that the other constituents may contribute to the mechanical behavior of mammalian dentin. Our results also present several remaining opportunities for further investigation into the roles of organic components (e.g., collagen) and mineral content on dentin mechanical behavior.
Topics: Animals; Dentin; Dogs; Elastic Modulus; Hardness; Mammals; Microscopy, Electron, Scanning; Structure-Activity Relationship; Tooth
PubMed: 35834939
DOI: 10.1016/j.jbiomech.2022.111218 -
Dental Materials Journal Nov 2022The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D printing of...
The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D printing of occlusal splints, as well as to evaluate the differences in wear and surface hardness between rigid and flexible 3D-printed occlusal splint materials. Two-body wear and Vickers hardness tests were performed. The vertical wear depth and Vickers hardness values were statistically analyzed. Vertical wear depth and surface hardness values were statistically significant among the investigated materials (p<0.05). The lowest vertical wear depth was observed for the heat-cured resin (27.5±2.4 μm), PMMA-based milled material (30.5±2.8 μm), and autopolymerizing resin (36.7±6.3 μm), with no statistical difference (p<0.05). Flexible 3D-printed and CAD-CAM milled polycarbonate-based splint materials displayed lower surface hardness and higher wear than the PMMA-based materials. PMMA-based splint materials displayed the most consistent surface hardness and wear resistance regardless of the manufacturing technology.
Topics: Occlusal Splints; Hardness; Polymethyl Methacrylate; Materials Testing; Computer-Aided Design; Printing, Three-Dimensional; Surface Properties
PubMed: 36288940
DOI: 10.4012/dmj.2022-100 -
Molecules (Basel, Switzerland) Dec 2022The chemical hardness concept and its realization within the conceptual density functional theory is approached with innovative perspectives, such as the... (Review)
Review
The chemical hardness concept and its realization within the conceptual density functional theory is approached with innovative perspectives, such as the electronegativity and hardness equalization of atoms in molecules connected with the softness kernel, in order to examine the structure-reactivity equalization ansatz between the electronic sharing index and the charge transfer either in the additive or geometrical mean picture of bonding. On the other hand, the maximum hardness principle presents a relation with the chemical stability of the hardness concept. In light of the inverse relation between hardness and polarizability, the minimum polarizability principle has been proposed. Additionally, this review includes important applications of the chemical hardness concept to solid-state chemistry. The mentioned applications support the validity of the electronic structure principles regarding chemical hardness and polarizability in solid-state chemistry.
Topics: Hardness; Density Functional Theory; Molecular Structure
PubMed: 36557957
DOI: 10.3390/molecules27248825 -
Diagnostic Pathology Jul 2022Plaque hardness in carotid artery stenosis correlates with cerebral infarction. This study aimed to quantitatively compare plaque hardness with histopathological... (Observational Study)
Observational Study
BACKGROUND
Plaque hardness in carotid artery stenosis correlates with cerebral infarction. This study aimed to quantitatively compare plaque hardness with histopathological findings and identify the pathological factors involved in plaque hardness.
METHODS
This study included 84 patients (89 lesions) undergoing carotid endarterectomy (CEA) at our institution. Plaque hardness was quantitatively measured immediately after excision using a hardness meter. Collagen and calcification were evaluated as the pathological factors. Collagen was stained with Elastica van Gieson stain, converted to a gray-scale image, and displayed in a 256-step histogram. The median gray-scale median (GSM) was used as the collagen content. The degree of calcification was defined by the hematoxylin-eosin stain as follows: "0:" no calcification, "1:" scattered microcalcification, or "2:" calcification greater than 1 mm or more than 2% of the total calcification. Carotid echocardiographic findings, specifically echoluminance or the brightness of the narrowest lesion of the plaque, classified as hypo-, iso-, or hyper-echoic by comparison with the intima-media complex surrounding the plaque, and clinical data were reviewed.
RESULTS
Plaque hardness was significantly negatively correlated with GSM [Spearman's correlation coefficient: -0.7137 (p < 0.0001)]: the harder the plaque, the higher the collagen content. There were significant differences between plaque hardness and degree of calcification between "0" and "2" (p = 0.0206). For plaque hardness and echoluminance (hypo-iso-hyper), significant differences were found between hypo-iso (p = 0.0220), hypo-hyper (p = 0.0006), and iso-hyper (p = 0.0015): the harder the plaque, the higher the luminance. In single regression analysis, GSM, sex, and diabetes mellitus were significant variables, and in multiple regression analysis, only GSM was extracted as a significant variable.
CONCLUSIONS
Plaque hardness was associated with a higher amount of collagen, which is the main component of the fibrous cap. Greater plaque hardness was associated with increased plaque stability. The degree of calcification may also be associated with plaque hardness.
Topics: Calcinosis; Carotid Stenosis; Collagen; Endarterectomy, Carotid; Hardness; Humans; Plaque, Atherosclerotic
PubMed: 35818059
DOI: 10.1186/s13000-022-01239-y -
Journal of the Mechanical Behavior of... Dec 2021Biodentine is a calcium silicate/calcium carbonate/zirconium dioxide/water-based dental replacement biomaterial, significantly outperforming the stiffness and hardness...
Biodentine is a calcium silicate/calcium carbonate/zirconium dioxide/water-based dental replacement biomaterial, significantly outperforming the stiffness and hardness properties of chemically similar construction cement pastes. We here report the first systematic micromechanical investigation of Biodentine, combining grid nanoindentation with ultrasonic testing and micromechanical modeling. Histograms of nanoindentation-probed hardness and elastic modulus, comprising more than 5700 values each, are very well represented by the superposition of three log-normal distributions (LNDs). Most of the data (74%) belong to the intermediate LND, representing highly dense calcite-reinforced hydration products with on-average more than 60GPa elastic modulus and 3GPa hardness. The remaining data refer, on the one hand, to lower density hydration products, and on the other hand, to single-micron-sized unhydrated clinker and zirconium-dioxide inclusions. Micromechanical homogenization of these three material phases delivers elastic properties of the overall cement paste material, which significantly exceed those probed by more than 300 ultrasonic tests performed in the kHz and MHz regime. This indicates the presence of micro-defects, which slightly weaken the otherwise highly optimized biomaterial system.
Topics: Calcium Carbonate; Construction Materials; Glass Ionomer Cements; Hardness; Water
PubMed: 34634693
DOI: 10.1016/j.jmbbm.2021.104863 -
Nature Communications Oct 2023Stretchability is an essential property for wearable devices to match varying strains when interfacing with soft tissues or organs. While piezoelectricity has broad...
Stretchability is an essential property for wearable devices to match varying strains when interfacing with soft tissues or organs. While piezoelectricity has broad application potentials as tactile sensors, artificial skins, or nanogenerators, enabling tissue-comparable stretchability is a main roadblock due to the intrinsic rigidity and hardness of the crystalline phase. Here, an amino acid-based piezoelectric biocrystal thin film that offers tissue-compatible omnidirectional stretchability with unimpaired piezoelectricity is reported. The stretchability was enabled by a truss-like microstructure that was self-assembled under controlled molecule-solvent interaction and interface tension. Through the open and close of truss meshes, this large scale biocrystal microstructure was able to endure up to 40% tensile strain along different directions while retained both structural integrity and piezoelectric performance. Built on this structure, a tissue-compatible stretchable piezoelectric nanogenerator was developed, which could conform to various tissue surfaces, and exhibited stable functions under multidimensional large strains. In this work, we presented a promising solution that integrates piezoelectricity, stretchability and biocompatibility in one material system, a critical step toward tissue-compatible biomedical devices.
Topics: Wearable Electronic Devices; Hardness
PubMed: 37848410
DOI: 10.1038/s41467-023-42184-8