The Cochrane Database of Systematic... Apr 2022Tracheal intubation is a common procedure performed to secure the airway in adults undergoing surgery or those who are critically ill. Intubation is sometimes associated... (Review)
Review
BACKGROUND
Tracheal intubation is a common procedure performed to secure the airway in adults undergoing surgery or those who are critically ill. Intubation is sometimes associated with difficulties and complications that may result in patient harm. While it is traditionally achieved by performing direct laryngoscopy, the past three decades have seen the advent of rigid indirect videolaryngoscopes (VLs). A mounting body of evidence comparing the two approaches to tracheal intubation has been acquired over this period of time. This is an update of a Cochrane Review first published in 2016.
OBJECTIVES
To assess whether use of different designs of VLs in adults requiring tracheal intubation reduces the failure rate compared with direct laryngoscopy, and assess the benefits and risks of these devices in selected population groups, users and settings.
SEARCH METHODS
We searched MEDLINE, Embase, CENTRAL and Web of Science on 27 February 2021. We also searched clinical trials databases, conference proceedings and conducted forward and backward citation searches.
SELECTION CRITERIA
We included randomized controlled trials (RCTs) and quasi-RCTs with adults undergoing laryngoscopy performed with either a VL or a Macintosh direct laryngoscope (DL) in any clinical setting. We included parallel and cross-over study designs.
DATA COLLECTION AND ANALYSIS
We used standard methodological procedures expected by Cochrane. We collected data for the following outcomes: failed intubation, hypoxaemia, successful first attempt at tracheal intubation, oesophageal intubation, dental trauma, Cormack-Lehane grade, and time for tracheal intubation.
MAIN RESULTS
We included 222 studies (219 RCTs, three quasi-RCTs) with 26,149 participants undergoing tracheal intubation. Most studies recruited adults undergoing elective surgery requiring tracheal intubation. Twenty-one studies recruited participants with a known or predicted difficult airway, and an additional 25 studies simulated a difficult airway. Twenty-one studies were conducted outside the operating theatre environment; of these, six were in the prehospital setting, seven in the emergency department and eight in the intensive care unit. We report here the findings of the three main comparisons according to videolaryngoscopy device type. We downgraded the certainty of the outcomes for imprecision, study limitations (e.g. high or unclear risks of bias), inconsistency when we noted substantial levels of statistical heterogeneity and publication bias. Macintosh-style videolaryngoscopy versus direct laryngoscopy (61 studies, 9883 participants) We found moderate-certainty evidence that a Macintosh-style VL probably reduces rates of failed intubation (risk ratio (RR) 0.41, 95% confidence interval (CI) 0.26 to 0.65; 41 studies, 4615 participants) and hypoxaemia (RR 0.72, 95% CI 0.52 to 0.99; 16 studies, 2127 participants). These devices may also increase rates of success on the first intubation attempt (RR 1.05, 95% CI 1.02 to 1.09; 42 studies, 7311 participants; low-certainty evidence) and probably improve glottic view when assessed as Cormack-Lehane grade 3 and 4 (RR 0.38, 95% CI 0.29 to 0.48; 38 studies, 4368 participants; moderate-certainty evidence). We found little or no clear difference in rates of oesophageal intubation (RR 0.51, 95% CI 0.22 to 1.21; 14 studies, 2404 participants) but this finding was supported by low-certainty evidence. We were unsure of the findings for dental trauma because the certainty of this evidence was very low (RR 0.68, 95% CI 0.16 to 2.89; 18 studies, 2297 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I = 96%). Hyperangulated videolaryngoscopy versus direct laryngoscopy (96 studies, 11,438 participants) We found moderate-certainty evidence that hyperangulated VLs probably reduce rates of failed intubation (RR 0.51, 95% CI 0.34 to 0.76; 63 studies, 7146 participants) and oesophageal intubation (RR 0.39, 95% CI 0.18 to 0.81; 14 studies, 1968 participants). In subgroup analysis, we noted that hyperangulated VLs were more likely to reduce failed intubation when used on known or predicted difficult airways (RR 0.29, 95% CI 0.17 to 0.48; P = 0.03 for subgroup differences; 15 studies, 1520 participants). We also found that these devices may increase rates of success on the first intubation attempt (RR 1.03, 95% CI 1.00 to 1.05; 66 studies, 8086 participants; low-certainty evidence) and the glottic view is probably also improved (RR 0.15, 95% CI 0.10 to 0.24; 54 studies, 6058 participants; data for Cormack-Lehane grade 3/4 views; moderate-certainty evidence). However, we found low-certainty evidence of little or no clear difference in rates of hypoxaemia (RR 0.49, 95% CI 0.22 to 1.11; 15 studies, 1691 participants), and the findings for dental trauma were unclear because the certainty of this evidence was very low (RR 0.51, 95% CI 0.16 to 1.59; 30 studies, 3497 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I = 99%). Channelled videolaryngoscopy versus direct laryngoscopy (73 studies, 7165 participants) We found moderate-certainty evidence that channelled VLs probably reduce rates of failed intubation (RR 0.43, 95% CI 0.30 to 0.61; 53 studies, 5367 participants) and hypoxaemia (RR 0.25, 95% CI 0.12 to 0.50; 15 studies, 1966 participants). They may also increase rates of success on the first intubation attempt (RR 1.10, 95% CI 1.05 to 1.15; 47 studies, 5210 participants; very low-certainty evidence) and probably improve glottic view (RR 0.14, 95% CI 0.09 to 0.21; 40 studies, 3955 participants; data for Cormack-Lehane grade 3/4 views; moderate-certainty evidence). We found little or no clear difference in rates of oesophageal intubation (RR 0.54, 95% CI 0.17 to 1.75; 16 studies, 1756 participants) but this was supported by low-certainty evidence. We were unsure of the findings for dental trauma because the certainty of the evidence was very low (RR 0.52, 95% CI 0.13 to 2.12; 29 studies, 2375 participants). We were not able to pool data for time required for tracheal intubation owing to considerable heterogeneity (I = 98%).
AUTHORS' CONCLUSIONS
VLs of all designs likely reduce rates of failed intubation and result in higher rates of successful intubation on the first attempt with improved glottic views. Macintosh-style and channelled VLs likely reduce rates of hypoxaemic events, while hyperangulated VLs probably reduce rates of oesophageal intubation. We conclude that videolaryngoscopy likely provides a safer risk profile compared to direct laryngoscopy for all adults undergoing tracheal intubation.
Topics: Adult; Critical Illness; Humans; Intubation, Intratracheal; Laryngoscopes; Laryngoscopy
PubMed: 35373840
DOI: 10.1002/14651858.CD011136.pub3 -
The New England Journal of Medicine Aug 2023Whether video laryngoscopy as compared with direct laryngoscopy increases the likelihood of successful tracheal intubation on the first attempt among critically ill... (Randomized Controlled Trial)
Randomized Controlled Trial
BACKGROUND
Whether video laryngoscopy as compared with direct laryngoscopy increases the likelihood of successful tracheal intubation on the first attempt among critically ill adults is uncertain.
METHODS
In a multicenter, randomized trial conducted at 17 emergency departments and intensive care units (ICUs), we randomly assigned critically ill adults undergoing tracheal intubation to the video-laryngoscope group or the direct-laryngoscope group. The primary outcome was successful intubation on the first attempt. The secondary outcome was the occurrence of severe complications during intubation; severe complications were defined as severe hypoxemia, severe hypotension, new or increased vasopressor use, cardiac arrest, or death.
RESULTS
The trial was stopped for efficacy at the time of the single preplanned interim analysis. Among 1417 patients who were included in the final analysis (91.5% of whom underwent intubation that was performed by an emergency medicine resident or a critical care fellow), successful intubation on the first attempt occurred in 600 of the 705 patients (85.1%) in the video-laryngoscope group and in 504 of the 712 patients (70.8%) in the direct-laryngoscope group (absolute risk difference, 14.3 percentage points; 95% confidence interval [CI], 9.9 to 18.7; P<0.001). A total of 151 patients (21.4%) in the video-laryngoscope group and 149 patients (20.9%) in the direct-laryngoscope group had a severe complication during intubation (absolute risk difference, 0.5 percentage points; 95% CI, -3.9 to 4.9). Safety outcomes, including esophageal intubation, injury to the teeth, and aspiration, were similar in the two groups.
CONCLUSIONS
Among critically ill adults undergoing tracheal intubation in an emergency department or ICU, the use of a video laryngoscope resulted in a higher incidence of successful intubation on the first attempt than the use of a direct laryngoscope. (Funded by the U.S. Department of Defense; DEVICE ClinicalTrials.gov number, NCT05239195.).
Topics: Humans; Adult; Laryngoscopy; Critical Illness; Intubation, Intratracheal; Laryngoscopes; Emergency Service, Hospital; Video Recording
PubMed: 37326325
DOI: 10.1056/NEJMoa2301601 -
British Journal of Anaesthesia Oct 2022Tracheal intubation is a commonly performed procedure that can be associated with complications and result in patient harm. Videolaryngoscopy (VL) may decrease this risk... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Tracheal intubation is a commonly performed procedure that can be associated with complications and result in patient harm. Videolaryngoscopy (VL) may decrease this risk as compared with Macintosh direct laryngoscopy (DL). This review evaluates the risk and benefit profile of VL compared with DL in adults.
METHODS
We searched MEDLINE, Embase, CENTRAL, and Web of Science on February 27, 2021. We included RCTs comparing VL with DL in patients undergoing tracheal intubation in any setting. We separately compared outcomes according to VL design: Macintosh-style, hyperangulated, and channelled.
RESULTS
A total of 222 RCTs (with 26 149 participants) were included. Most studies had unclear risk of bias in at least one domain, and all were at high risk of performance and detection bias. We found that videolaryngoscopes of any design likely reduce rates of failed intubation (Macintosh-style: risk ratio [RR]=0.41; 95% confidence interval [CI], 0.26-0.65; hyperangulated: RR=0.51; 95% CI, 0.34-0.76; channelled: RR=0.43, 95% CI, 0.30-0.61; moderate-certainty evidence) with increased rates of successful intubation on first attempt and better glottic views across patient groups and settings. Hyperangulated designs are likely favourable in terms of reducing the rate of oesophageal intubation, and result in improved rates of successful intubation in individuals presenting with difficult airway features (P=0.03). We also present other patient-oriented outcomes.
CONCLUSIONS
In this systematic review and meta-analysis of trials of adults undergoing tracheal intubation, VL was associated with fewer failed attempts and complications such as hypoxaemia, whereas glottic views were improved.
SYSTEMATIC REVIEW REGISTRATION
This article is based on a Cochrane Review published in the Cochrane Database of Systematic Reviews (CDSR) 2022, Issue 4, DOI: 10.1002/14651858.CD011136.pub3 (see www.cochranelibrary.com for information). Cochrane Reviews are regularly updated as new evidence emerges and in response to feedback, and the CDSR should be consulted for the most recent version of the review.
Topics: Adult; Esophagus; Glottis; Humans; Intubation, Intratracheal; Laryngoscopes; Laryngoscopy
PubMed: 35820934
DOI: 10.1016/j.bja.2022.05.027 -
Respiratory Care Jun 2014Visualization of the larynx by direct or indirect means is referred to as laryngoscopy and is the principal aim during airway management for passage of a tracheal tube.... (Review)
Review
Visualization of the larynx by direct or indirect means is referred to as laryngoscopy and is the principal aim during airway management for passage of a tracheal tube. This paper presents a brief background regarding the development and practice of laryngoscopy and examines the equipment and techniques for both direct and indirect methods. Patient evaluation during the airway examination is discussed, as are predictors for difficult intubation. Laryngoscope blade design, newer intubating techniques, and a variety of indirect laryngoscopic technologies are reviewed, as is the learning curve for these techniques and devices.
Topics: Equipment Design; Humans; Intubation, Intratracheal; Laryngoscopy; Patient Positioning; Patient Safety; Video Recording
PubMed: 24891195
DOI: 10.4187/respcare.03033 -
British Journal of Anaesthesia Oct 2022Recent evidence, highlighted in this editorial, creates a strong argument for universal use of videolaryngoscopy in anaesthesia to improve efficiency and safety of...
Recent evidence, highlighted in this editorial, creates a strong argument for universal use of videolaryngoscopy in anaesthesia to improve efficiency and safety of tracheal intubation. In a recent study published in the British Journal of Anaesthesia, the authors implemented widespread (66%) use of videolaryngoscopy as first choice in one hospital and compared this with a control hospital, in which this was not implemented. Increased videolaryngoscopy use was associated with a significant fall in the rate of difficult airways, use of airway rescue techniques, and operator-reported difficulty, whilst in the control hospitals no such changes were seen. Locations outside the operating theatre might also benefit from universal laryngoscopy, but the evidence base is less robust, most notably in pre-hospital emergency medicine. The extent to which variation in results in different locations is attributable to different patient factors or organisational and operator factors is considered.
Topics: Anesthesiology; Humans; Intubation, Intratracheal; Laryngoscopes; Laryngoscopy; Operating Rooms
PubMed: 36192053
DOI: 10.1016/j.bja.2022.07.038 -
The Permanente Journal Sep 2023Introduction Advances in airway technology, in particular video laryngoscopy, are forcing attending emergency medicine physicians to master and maintain innovative...
Introduction Advances in airway technology, in particular video laryngoscopy, are forcing attending emergency medicine physicians to master and maintain innovative airway skills. This study compares intubation times and other airway outcomes between resident and attending physicians using direct and video laryngoscopy in a mannequin model. Methods Fifty emergency medicine resident and attending physicians were asked to intubate a mannequin, using direct laryngoscopy, a C-MAC standard geometry blade, and a GlideScope hyperangulated blade. Intubation times, intubation success and accuracy, Cormack-Lehane grades, and the physician's opinion of the ease of the intubation were recorded for each intubation. Results Second-year residents had significantly quicker intubation times than attending physicians with all 3 intubation modalities. They also outperformed the interns when using the C-MAC standard geometry blade and had faster intubation times compared to third-year residents using direct laryngoscopy. When using the GlideScope hyperangulated blade, all 3 years of residents had lower intubation times compared to attending physicians and they were more accurate with endotracheal tube placement. Unlike the second-year residents, the third-year residents were not faster at direct laryngoscopy compared to the attending physicians. Conclusion Second-year residents outperformed their resident counterparts and the attending physicians with improved intubation times. Nontraditional intubation techniques associated with the GlideScope hyperangulated blade must be learned, practiced, and maintained by attending physicians, which is reflected in their longer intubation times compared to the residents. In addition, DL skills can deteriorate among resident physicians if they are not used on a regular basis.
Topics: Humans; Laryngoscopy; Video Recording; Laryngoscopes; Intubation, Intratracheal; Physicians
PubMed: 37231774
DOI: 10.7812/TPP/23.007 -
F1000Research 2019Recent advances in technology have made laryngoscopy less dependent upon a direct line of sight to achieve tracheal intubation. Whether these new devices are useful... (Review)
Review
Recent advances in technology have made laryngoscopy less dependent upon a direct line of sight to achieve tracheal intubation. Whether these new devices are useful tools capable of increasing patient safety depends upon when and how they are used. We briefly consider the challenges in reviewing the emerging literature given the variety of devices, "experience" of the care providers, the clinical settings, and the definitions of outcome. We examine some of the limitations of conventional direct laryngoscopy, question the definitions we have used to define success, discuss the benefits of indirect (video) techniques, and review evidence pertaining to their use in the patients in the operating room, emergency department, and intensive care unit.
Topics: Adult; Emergency Service, Hospital; Humans; Intensive Care Units; Intubation, Intratracheal; Laryngoscopy; Patient Safety
PubMed: 31231508
DOI: 10.12688/f1000research.18544.1 -
Annals of Biomedical Engineering Jan 2022Retractors and scopes used in head and neck surgery to provide adequate surgical exposure also deform critical structures in the region. Surgeons typically use...
Retractors and scopes used in head and neck surgery to provide adequate surgical exposure also deform critical structures in the region. Surgeons typically use preoperative imaging to plan and guide their tumor resections, however the large tissue deformation resulting from placement of retractors and scopes reduces the utility of preoperative imaging as a reliable roadmap. We quantify the extent of tumor and vasculature deformation in patients with tumors of the larynx and pharynx undergoing diagnostic laryngoscopy. A mean tumor displacement of 1.02 cm was observed between the patients' pre- and intra-operative states. Mean vasculature displacement at key bifurcation points was 0.99 cm. Registration to the hyoid bone can reduce tumor displacement to 0.67 cm and improve carotid stem angle deviations but increase overall vasculature displacement. The large deformation results suggest limitations in reliance on preoperative imaging and that using specific landmarks intraoperatively or having more intraoperative information could help to compensate for these deviations and ultimately improve surgical success.
Topics: Humans; Laryngoscopy; Larynx; Microsurgery; Neoplasms; Pharynx
PubMed: 34993696
DOI: 10.1007/s10439-021-02896-8 -
The Cochrane Database of Systematic... Jun 2018Establishment of a secure airway is a critical part of neonatal resuscitation in the delivery room and the neonatal unit. Videolaryngoscopy has the potential to... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Establishment of a secure airway is a critical part of neonatal resuscitation in the delivery room and the neonatal unit. Videolaryngoscopy has the potential to facilitate successful endotracheal intubation and decrease adverse consequences of delay in airway stabilization. Videolaryngoscopy may enhance visualization of the glottis and intubation success in neonates.
OBJECTIVES
To determine the efficacy and safety of videolaryngoscopy compared to direct laryngoscopy in decreasing the time and attempts required for endotracheal intubation and increasing the success rate at first intubation in neonates.
SEARCH METHODS
We used the search strategy of Cochrane Neonatal. In May 2017, we searched for randomized controlled trials (RCT) evaluating videolaryngoscopy for neonatal endotracheal intubation in Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, CINAHL, abstracts of the Pediatric Academic Societies, websites for registered trials at www.clinicaltrials.gov and www.controlled-trials.com, and reference lists of relevant studies.
SELECTION CRITERIA
RCTs or quasi-RCTs in neonates evaluating videolaryngoscopy for endotracheal intubation compared with direct laryngoscopy.
DATA COLLECTION AND ANALYSIS
Review authors performed data collection and analysis as recommended by Cochrane Neonatal. Two review authors independently assessed studies identified by the search strategy for inclusion.We used the GRADE approach to assess the quality of evidence.
MAIN RESULTS
The search yielded 7057 references of which we identified three RCTs for inclusion, four ongoing trials and one study awaiting classification. All three included RCTs compared videolaryngoscopy with direct laryngoscopy during intubation attempts by trainees.Time to intubation was similar between videolaryngoscopy and direct laryngoscopy (mean difference (MD) -0.62, 95% confidence interval (CI) -6.50 to 5.26; 2 studies; 311 intubations) (very low quality evidence). Videolaryngoscopy did not decrease the number of intubation attempts (MD -0.05, 95% CI -0.18 to 0.07; 2 studies; 427 intubations) (very low quality evidence). Moderate quality evidence suggested that videolaryngoscopy increased the success of intubation at first attempt (typical risk ratio (RR) 1.44, 95% CI 1.20 to 1.73; typical risk difference (RD) 0.19, 95% CI 0.10 to 0.28; number needed to treat for an additional beneficial outcome (NNTB) 5, 95% CI 4 to 10; 3 studies; 467 intubation attempts).Desaturation episodes during intubation attempts were similar between videolaryngoscopy and direct laryngoscopy (MD -0.76, 95% CI -5.74 to 4.23; 2 studies; 359 intubations) (low quality evidence). There was no difference in the incidence of airway trauma due to intubation attempts (RR 0.10, 95% CI 0.01 to 1.80; RD -0.04, 95% CI -0.09 to -0.00; 1 study; 213 intubations) (low quality evidence).There were no data available on other adverse effects of videolaryngoscopy.
AUTHORS' CONCLUSIONS
Moderate to very low quality evidence suggests that videolaryngoscopy increases the success of intubation in the first attempt but does not decrease the time to intubation or the number of attempts for intubation. However, these studies were conducted with trainees performing the intubations and these results highlight the potential usefulness of the videolaryngoscopy as a teaching tool. Well-designed, adequately powered RCTs are necessary to confirm efficacy and address safety and cost-effectiveness of videolaryngoscopy for endotracheal intubation in neonates by trainees and those proficient in direct laryngoscopy.
Topics: Humans; Infant, Newborn; Intubation, Intratracheal; Laryngoscopes; Laryngoscopy; Randomized Controlled Trials as Topic; Resuscitation; Time Factors
PubMed: 29862490
DOI: 10.1002/14651858.CD009975.pub3 -
Canadian Family Physician Medecin de... Nov 2013
Topics: Humans; Laryngeal Diseases; Laryngoscopy
PubMed: 24235194
DOI: No ID Found