Cureus Jun 2022Literature does not show any studies regarding plate placement problems in the coronal plane of patients with volar plating due to distal radius fracture diagnosis. We...
BACKGROUND AND OBJECTIVES
Literature does not show any studies regarding plate placement problems in the coronal plane of patients with volar plating due to distal radius fracture diagnosis. We aimed to investigate the functional and laboratory results of the coronal malposition of the volar locking plate in patients with distal radius fracture treated with internal fixation.
METHODS
In this retrospective study, we included patients who had volar plate fixation, were aged between 18 and 80, had no pathological fracture, had a minimum of six months of follow-up, and had the same rehabilitation protocol. We consider the angle subtended on the coronal axis between the distal radius long axis and the distal radius locking plate as coronal malposition. We named the coronal malposition angle the "AYE Angle." Patients with an AYE angle of over 1 degree were evaluated under group 1. Patients with an AYE angle of 0-1 degrees were evaluated under group 2. Radiological parameters were taken from AP-Lateral X-ray views. Superficial University System of Georgia (USG) examinations were applied to detect tendon problems. The DASH and QUICK-DASH scoring systems were used for clinical evaluation. Grip strength was measured with a dynamometer in all patients. All results were compared between the two groups.
RESULTS
Thirteen patients were female and 27 patients were male. Nineteen patients who had coronal malposition were added to group 1, while 21 patients who had no coronal malposition were added to group 2. Fifteen patients had normal USG results in group 2, while 18 patients had edema around the flexor pollicis longus (FPL) tendon as a result of USG in group 1. Statistically, a significant difference was detected between the two groups in terms of the amount of tenosynovitis around FPL (p=0.01). A statistically significant relationship was found between USG grading and malposition grading. The study revealed that a higher rate of USG grade 2 was found in patients with malposition grade 2 (90.9%), while a higher rate of USG grade 1 (50%) was observed in patients with malposition grade 1 (p=0.01). A statistically significant difference was not found between Soong grading and USG in terms of the level of tenosynovitis around the FPL tendon. The amount of tenosynovitis detected around the FPL tendon was 62.5% for Soong and grade 0 level, 60.7% for grade 1 level, and 50% for grade 2 level. There was no statistically significant difference between the two groups in the DASH and QUICK-DASH scoring systems (p=0.96). There was no statistically significant difference between the two groups in the grip strength (p=0.52).
CONCLUSION
Coronal plate position in the treatment of the distal radius fracture is important to avoid potential flexor tendon problems. The volar plate position should be adjusted properly both in the coronal and sagittal axes.
PubMed: 35915673
DOI: 10.7759/cureus.26444 -
European Journal of Midwifery 2022Fetal malposition in labor results in adverse maternal and infant health. Whilst evidence for effective interventions is inconclusive, based on the hypothesis that...
INTRODUCTION
Fetal malposition in labor results in adverse maternal and infant health. Whilst evidence for effective interventions is inconclusive, based on the hypothesis that gravity corrects malposition, the feasibility and design of a randomized controlled trial (RCT) to improve maternal and infant health outcomes should be considered. The aim was to assess pregnant women's views on the acceptability, enablers, and barriers of participation in an RCT of maternal posture for fetal malposition in labor.
METHODS
A web-based anonymous survey of pregnant women was conducted in Auckland during 2020. Quantitative data were summarized descriptively using a chi-squared test to assess differences in proportions. Maternal characteristics influence on women's responses was assessed using cross-tabulation. A thematic content analysis of free text responses was undertaken.
RESULTS
Most of the 206 respondents were aged 26-35 years (75%), 29-38 weeks pregnant (71%), of European (40%) or Asian (36%) ethnicity, and similarly nulliparous or multiparous. Most women (76%) knew of fetal malposition in labor; however, only 28% were aware of maternal posture to correct this. Most women (86%) were interested in labor research and although 37% would participate in an RCT, almost half (47%) were unsure and a 15% would not participate. Concerns mostly related to comfort (22%). Nearly half of women (49%) would need to consult their partner regarding participation in an RCT.
CONCLUSIONS
Enablers for participation in a posture trial in labor include measures to enhance maternal comfort, increasing awareness of malposition and the role of posture, and involving partners in pre-trial counselling and recruitment.
PubMed: 35128346
DOI: 10.18332/ejm/144057 -
Frontiers in Cardiovascular Medicine 2022Transcatheter aortic valve replacement (TAVR) in the treatment of patients with pure native aortic valve regurgitation (NAVR) has been based on the "off-label"...
Anatomic predictor of severe prosthesis malposition following transcatheter aortic valve replacement with self- expandable Venus-A Valve among pure aortic regurgitation: A multicenter retrospective study.
BACKGROUND
Transcatheter aortic valve replacement (TAVR) in the treatment of patients with pure native aortic valve regurgitation (NAVR) has been based on the "off-label" indications, while the absence of aortic valve calcification and difficulty in anchoring was found to significantly increase the risk of prosthesis malposition. The aim of this study was to explore the anatomical predictors of severe prosthesis malposition following TAVR with the self-expandable Venus-A Valve among patients with NAVR.
METHODS
A total of 62 patients with NAVR who underwent TAVR with Venus-A Valve at four Chinese clinical centers were retrospectively observed. The clinical features, aortic multidetector computed tomography (MDCT) data, and clinical outcomes were compared between non-/mild malposition and severe malposition groups. Univariate logistic regression analysis was used to identify the risk factors of severe prosthesis malposition, and the receiver operating characteristic (ROC) curve was used to explore the predictive value of the risk factors.
RESULTS
Valve migration to ascending aortic direction occurred in 1 patient, and the remaining 61 patients (including 19 severe malposition cases and 42 non-/mild malposition cases) were included in the analysis. The diameter and height of the sinotubular junction (STJ) and STJ cover index (STJCI, calculated as 100%*STJ diameter/nominal prosthesis crown diameter) were all greater in the severe malposition group (all < 0.05). Logistic regression showed that STJ diameter (OR = 1.23, 95% CI 1.04-1.47, = 0.017), STJ height (OR = 1.24, 95% CI 1.04-1.47, = 0.017), and STJCI (OR = 1.08, 95% CI 1.01-1.16, = 0.032) were potential predictors for severe prosthesis malposition. The area under the ROC curve was 0.72 (95% CI 0.58-0.85, = 0.008) for STJ diameter, 0.70 (95% CI 0.55-0.86, = 0.012) for STJ height, and 0.69 (95% CI 0.55-0.83, = 0.017) for STJCI, respectively. The cutoff value was 33.2 mm for STJ diameter (sensitivity was 84.2% and specificity was 65.8%), 24.1 mm for STJ height (sensitivity was 57.9% and specificity was 87.8%), and 81.0% for STJCI (sensitivity was 68.4% and specificity was 68.3%), respectively.
CONCLUSION
Larger and higher STJ, as well as greater STJ to valve crown diameter ratio, may help identify patients at high risk for severe prosthesis malposition among patients with NAVR undergoing TAVR with Venus-A prosthesis valve.
PubMed: 36568558
DOI: 10.3389/fcvm.2022.1002071 -
Clinical Orthopaedics and Related... May 2013Arthroscopic partial meniscectomy can be complicated by excessive resection, damage to articular cartilage, neurovascular injury, persistent drainage from portals, and... (Review)
Review
Arthroscopic partial meniscectomy can be complicated by excessive resection, damage to articular cartilage, neurovascular injury, persistent drainage from portals, and infection; the procedure can be rendered more difficult, and the outcome less certain, if the surgeon fails to recognize concomitant injuries, malpositions the portals, or misidentifies the components of a meniscus tear. We review the problems that can occur as a result of errors made before, during, and after surgery.
Topics: Arthroscopy; Humans; Knee Injuries; Medical Errors; Menisci, Tibial; Postoperative Complications; Risk Factors; Tibial Meniscus Injuries; Treatment Outcome
PubMed: 23229431
DOI: 10.1007/s11999-012-2735-3 -
Beyoglu Eye Journal 2022The aim of the study was to evaluate the effect of changes in the horizontal and vertical palpebral fissure dimensions on surgical success performed due to entropion and...
OBJECTIVES
The aim of the study was to evaluate the effect of changes in the horizontal and vertical palpebral fissure dimensions on surgical success performed due to entropion and ectropion of the lower eyelid.
METHODS
The present research was conducted as a retrospective and interventional case series who had undergone involutional lower eyelid malposition repair with a lateral tarsal strip (LTS) alone, LTS with a medial spindle, and LTS with the advancement of the lower eyelid retractors. The subjects' medical records, including demographic and clinic characteristics, pre-operative assessment of horizontal eyelid laxity, and surgical outcomes, were reviewed. The distance between the pupillary light reflex and the lower-eyelid margin marginal reflex distance 2 (MRD-2) and the horizontal palpebral aperture (HPA) width were measured using the Image J program in the pre-operative and post-operative 6-month follow-up. The correlation between surgical success, changes in pre-operative and post-operative MRD-2, and HPA width was assessed by the Spearman rank correlation test.
RESULTS
A total of 66 eyelids of 48 patients were included in the study. This cohort comprised of 41 males (86.4%) and 7 females (13.6%), 18 of whom underwent bilateral surgery. The pre-operative mean MRD-2 was 7.13 ± 1.98 mm, and the post-operative 6-month mean MRD-2 was 6.21±1.19 mm (p<0.01). The mean post-operative HPA width was statistically significantly higher in comparison with the mean pre-operative HPA width (27.35±2.41, 26.89±2.39, p=0.02, respectively). There was no correlation between success rate and changes in horizontal and vertical palpebral fissure dimensions.
CONCLUSION
LTS surgery is a method that turns the shortened HPA width to normal and enables the successful correction of the lower eyelid malpositions.
PubMed: 35692271
DOI: 10.14744/bej.2022.75537 -
AJOG Global Reports Nov 2022In Dutch practice, gynecologists are used to assessing the position of the LNG-IUD by performing a two-dimensional transvaginal ultrasonography (TVUS) directly after...
BACKGROUND
In Dutch practice, gynecologists are used to assessing the position of the LNG-IUD by performing a two-dimensional transvaginal ultrasonography (TVUS) directly after insertion and do not routinely invite patients for another consultation 4-12 weeks after insertion. There is no consensus whether a TVUS six weeks after insertion is routinely needed.
OBJECTIVE
This study aimed to assess the incidence of malposition using 2-dimensional transvaginal ultrasonography during routine investigation 6 weeks after insertion. In addition, we investigated the relationship between malposition of the levonorgestrel 52-mg intrauterine device and unfavorable bleeding patterns and pelvic pain.
STUDY DESIGN
We performed a large prospective cohort study. Patients seeking a levonorgestrel 52-mg intrauterine device were eligible for inclusion. Transvaginal ultrasonography was performed to check position of the levonorgestrel 52-mg intrauterine device immediately after insertion and 6 weeks later. Patients filled in questionnaires about bleeding pattern and pelvic pain 6 weeks after insertion.
RESULTS
From March 2015 to December 2016, we enrolled 500 patients. Data from the transvaginal ultrasonography assessment 6 weeks after insertion were available for 448 patients, and complete data (transvaginal ultrasonography and questionnaire data) were available for 363 patients (72.6%). Malposition rate was 6.3% (28/448 patients). Malposition was seen in 15 of 198 patients (7.6%) with unfavorable bleeding and/or pelvic pain and in 3 of 165 patients (1.8%) with favorable bleeding patterns and no pelvic pain (=.03).Malposition was seen in 14 of 186 patients (7.5%) with an unfavorable bleeding pattern and in 4 of 177 patients (2.3%) with favorable bleeding patterns (=.008). Malposition was seen in 5 of 50 patients (10%) with pelvic pain and in 13 of 313 patients (4.2%) without pelvic pain (=.08).
CONCLUSION
The malposition rate of the levonorgestrel 52-mg intrauterine device observed using transvaginal ultrasonography 6 weeks after insertion was 6.3%. If patients have no complaints of unfavorable bleeding and/or pelvic pain, the risk for malposition is low (1.8%) and a routine transvaginal ultrasonography is not necessary. However, if patients experience unfavorable bleeding, a transvaginal ultrasonography should be considered to exclude malposition, because the effect of malposition on contraceptive effectiveness is unsure. Future research should focus on cost-benefit analysis.
PubMed: 36387294
DOI: 10.1016/j.xagr.2022.100104 -
Journal of Thoracic Disease Aug 2019One-lung ventilation (OLV) in thoracic anesthesia is required to provide good surgical exposure. OLV is commonly achieved through a double lumen tube (DLT) or a...
BACKGROUND
One-lung ventilation (OLV) in thoracic anesthesia is required to provide good surgical exposure. OLV is commonly achieved through a double lumen tube (DLT) or a bronchial blocker (BB). Malposition is a relevant issue related to these devices use. No prospective studies with adequately large sample size have been performed to evaluate the malposition rate of DLTs and BBs.
METHODS
A total of 2,127 patients requiring OLV during thoracic surgery were enrolled. The aim of this multicenter prospective observational study performed across 26 academic and community hospitals is to evaluate intraoperative malposition rate of DLTs and BBs. We also aim to assess: which device is the most used to achieve OLV, the frequency of bronchoscope (BRO) use, the incidence rate of desaturation during OLV and the role of other factors that can correlate to this event, and incidence of difficult airway.
RESULTS
Malposition rate for DLTs was 14%, for BBs 33%. DLTs were used in 95% of patients and BBs in 5%. Mean positioning time was shorter for DLT than BB (156±230 321±290 s). BRO was used in 54% of patients to check the correct positioning of the DLT. Desaturation occurred in 20% of all cases during OLV achieved through a DLT. Predicting factors of desaturation were dislocation (OR 2.03) and big size of DLT (OR 1.15). BRO use (OR 0.69) and left surgical side (OR 0.41) proved to be protective factors. Difficult airway prevalence was 16%; 10.8% predicted and 5.2% unpredicted.
CONCLUSIONS
DLT has a low malpositioning rate and is the preferred device to achieve OLV. BRO use recorded was unexpectedly low. The possibility of encountering a difficult airway is frequent, with an overall prevalence of 16%. Risk factors of desaturation are malposition and increased size of DLT. Left procedures and BRO use could lead to fewer episodes of desaturation.
PubMed: 31559028
DOI: 10.21037/jtd.2019.08.57 -
World Journal of Clinical Cases Sep 2020Hepatic portal venous gas in infants is frequently due to late presentation of necrotizing enterocolitis which is considered a relative indicator for surgical... (Review)
Review
BACKGROUND
Hepatic portal venous gas in infants is frequently due to late presentation of necrotizing enterocolitis which is considered a relative indicator for surgical intervention.
CASE SUMMARY
A preterm baby underwent an umbilical catheter placement and discovered in abdominal radiograph to have air in the portal venous system due to malpositioning of the umbilical catheter.
CONCLUSION
Hepatic portal venous gas in infants without signs of necrotizing enterocolitis could result from malposition of umbilical venous catheter, and in that case, should be managed medically, with no need for surgical intervention.
PubMed: 32953856
DOI: 10.12998/wjcc.v8.i17.3804 -
Radiology. Artificial Intelligence Mar 2023To develop and validate a deep learning model for detection of nasogastric tube (NGT) malposition on chest radiographs and assess model impact as a clinical decision...
PURPOSE
To develop and validate a deep learning model for detection of nasogastric tube (NGT) malposition on chest radiographs and assess model impact as a clinical decision support tool for junior physicians to help determine whether feeding can be safely performed in patients (feed/do not feed).
MATERIALS AND METHODS
A neural network ensemble was pretrained on 1 132 142 retrospectively collected (June 2007-August 2019) frontal chest radiographs and further fine-tuned on 7081 chest radiographs labeled by three radiologists. Clinical relevance was assessed on an independent set of 335 images. Five junior emergency medicine physicians assessed chest radiographs and made feed/do not feed decisions without and with artificial intelligence (AI)-generated NGT malposition probabilities placed above chest radiographs. Decisions from the radiologists served as ground truths. Model performance was evaluated using receiver operating characteristic analysis. Agreement between junior physician and radiologist decision was determined using the Cohen κ coefficient.
RESULTS
In the testing set, the ensemble achieved area under the receiver operating characteristic curve values of 0.82 (95% CI: 0.78, 0.86), 0.77 (95% CI: 0.71, 0.83), and 0.98 (95% CI: 0.96, 1.00) for satisfactory, malpositioned, and bronchial positions, respectively. In the clinical evaluation set, mean interreader agreement for feed/do not feed decisions among junior physicians was 0.65 ± 0.03 (SD) and 0.77 ± 0.13 without and with AI support, respectively. Mean agreement between junior physicians and radiologists was 0.53 ± 0.05 (unaided) and 0.65 ± 0.09 (AI-aided).
CONCLUSION
A simple classifier for NGT malposition may help junior physicians determine the safety of feeding in patients with NGTs. Neural Networks, Feature Detection, Supervised Learning, Machine Learning Published under a CC BY 4.0 license.
PubMed: 37035435
DOI: 10.1148/ryai.220165 -
Journal of Shoulder and Elbow Surgery May 2020Accurate and reliable assessment of acromial tilt (ATA) and slope (ASA) angles have been important in the clinical evaluation of degenerative and traumatic rotator cuff...
BACKGROUND
Accurate and reliable assessment of acromial tilt (ATA) and slope (ASA) angles have been important in the clinical evaluation of degenerative and traumatic rotator cuff tears. This study analyzed the influence of radiographic viewing perspective on the ATA and ASA and developed criteria to identify true lateral (TL) view radiographs.
METHODS
Three-dimensional computed tomographic (CT) reconstructions of 52 scapulae without rotator cuff tears or osteoarthritis were studied. Digitally reconstructed radiographs (DRRs) were aligned to obtain a TL view. In 10 random scapulae, incremental ante- and retroversion and up- and downward rotation views were generated (10° increments, ±30°), and ATA and ASA were measured by 2 observers. Clinically applicable criteria were developed and validated to identify TL views.
RESULTS
The mean ATA and ASA on TL views were 33°±4° (range 23°-42°) and 22°±7° (8°-43°), respectively. Mixed effect models showed that DRRs malpositioned in 20° and 30° anteversion and downward rotation decreased the ATA (P ≤ .030). DRRs malpositioned in anteversion and >10° of up- and downward rotation demonstrated a significantly decreased ASA (P ≤ .047). Intra- and interobserver reliability was excellent for TL views (intraclass correlation coefficient ≥ 0.95) but decreased with increasing viewing angle. Anatomic landmark criteria were capable of identifying TL-view radiographs with sensitivity of 81% and specificity of 82%.
CONCLUSION
Both ATA and ASA were significantly affected by malposition in anteversion and downward rotation of the scapula. Reliable ASA measurement was more susceptible in up- and downward rotation than the ATA. New visual criteria can identify TL-view radiographs and should be used in future studies to ensure consistency in ATA and ASA measurement.
Topics: Acromion; Adult; Aged; Anatomic Landmarks; Cadaver; Female; Humans; Imaging, Three-Dimensional; Male; Middle Aged; Reproducibility of Results; Rotation; Scapula; Sensitivity and Specificity; Tomography, X-Ray Computed
PubMed: 31784385