-
SAGE Open Medicine 2022Activities that require increased load bearing are known to cause bony hypertrophy. This phenomenon has been documented in the dominant arm of athletes in sports...
OBJECTIVE
Activities that require increased load bearing are known to cause bony hypertrophy. This phenomenon has been documented in the dominant arm of athletes in sports requiring significant utilization of a single limb. The literature addressing this effect in rodeo athletes, however, is minimal. Studies evaluating rodeo athletes are primarily focused on acute injury management rather than chronic symptoms resulting from changes in bone and soft tissue. We designed a study to evaluate bony hypertrophy in athletes without acute injury.
METHOD
Rodeo bareback riders presented with frequent pain in their grip arm, no radiographic evidence of injury, and clinical signs of peripheral nerve compression. Anteroposterior and lateral X-rays taken for initial evaluation in 17 bareback rodeo athletes were retrospectively reviewed. The diameter of bilateral ulnas was measured at its longitudinal midpoint. Ratio of Ulnar Diameters (grip arm/free arm) and Percentage Diameter Difference were calculated. An independent samples -test was used to assess differences in diameters of grip and non-grip arms.
RESULT
The mean ulnar diameter was 18.4 ± 3.5 in the grip arm and 16.6 ± 3.5 in the non-grip arm ( < 0.001). The mean ratio of grip to free arm ulnar diameter was 1.42 ± 0.21 (range = 1.05-1.92). The mean diameter percent difference measured 42.3% (range = 4.7%-92.0%), and the grip arm was observed to have a greater ulnar diameter compared to the non-grip arm.
CONCLUSION
There are significant anatomic differences in the grip arm of bareback rodeo athletes compared to the contralateral arm. In cases of persistent pain in the grip arm and no evidence of acute injury, these differences may be relevant to pain symptoms and should be considered as part of the assessment and treatment algorithm.
PubMed: 35223028
DOI: 10.1177/20503121221077831 -
Turkish Journal of Anaesthesiology and... Feb 2022Debates continue about the cricoid pressure, which has been used for many years to prevent gastric aspiration during intubation. Using ultrasound, the effects of this...
OBJECTIVE
Debates continue about the cricoid pressure, which has been used for many years to prevent gastric aspiration during intubation. Using ultrasound, the effects of this maneuver and alternatives like paralaryngeal pressure are revealed. The aim of this observational study was to determine the effect of paralaryngeal pressure with an ultrasound probe on the esophageal diameter in patients with different body mass indexes and neck circumferences.
METHODS
After measuring the neck circumference at the level of the cricoid cartilage, the esophagus was visualized by ultrasonography. Compression was applied medially at a 45° angle toward the vertebral column by the ultrasound probe and esophageal anteroposterior outer diameters were measured. Correlations between body mass index, neck circumference, esophageal diameter, and esophageal diameter change ratio were evaluated with Pearson's r value.
RESULTS
One hundred ten volunteers (52 women and 58 men) with mean age 33.7 ± 8.02 years and mean body mass index 25.6 ± 4.65 kg m-2 were recruited. The esophagus was located 78.18% partially to the left, 4.54% completely to the left, 1.81% to the right of the cricoid ring. In 15.45%, esophagus could not be displayed. The mean diameter of the esophagus was 7.6 ± 1.1 mm before pressure and 5.6 ± 0.09 mm after pressure (P < .001). There was no significant correlation between diameter change percentage and body mass index (r=-0.22; P > .05). However, weak correlation was found between diameter change percentage and neck circumference (r=-0.33; P=.016).
CONCLUSIONS
Paralaryngeal pressure with an ultrasound probe has the potential to occlude the esophagus and may be effective in all patient groups.
PubMed: 35256340
DOI: 10.5152/TJAR.2021.1427 -
Ear, Nose, & Throat Journal Aug 2019Large and deep defects resulting from lateral skull base surgery represent a challenge to the head and neck surgeon. Different microvascular free flaps have specific...
Large and deep defects resulting from lateral skull base surgery represent a challenge to the head and neck surgeon. Different microvascular free flaps have specific advantages and disadvantages. While the pedicled pectoralis major flap is considered a "work horse," it comes with a rather short pedicle. The aim of this study was to analyze the vascular anatomy of the pectoralis major flap and assess its suitability for microvascular transfer. Anatomical studies have been performed on 6 Thiel-fixed cadavers allowing a harvest of 12 flaps by the same surgeon. Measurements of the pedicle's length and vessel diameters have been taken with a ruler and caliper. The mean pedicle length and mean diameters (Ø) of the thoracoacromial artery and concomitant vein were found to be 9.8 cm, Ø 4.2 mm, and Ø 4.9 mm, respectively. These results suggest the potential utility of a free pectoralis major flap with microvascular anastomosis.
Topics: Cadaver; Free Tissue Flaps; Humans; Microvessels; Pectoralis Muscles; Plastic Surgery Procedures; Skull Base
PubMed: 31018692
DOI: 10.1177/0145561319840821 -
BMC Medical Imaging Dec 2022Ultrasound imaging is used for diagnosis, treatment, and blood vessel visualization during venous catheter placement. However, various physiological factors (e.g., body...
BACKGROUND
Ultrasound imaging is used for diagnosis, treatment, and blood vessel visualization during venous catheter placement. However, various physiological factors (e.g., body temperature and exercise) influence vein diameters, which are expected to exhibit daily or diurnal fluctuations. Therefore, this study aimed to determine the intraday (short-term) and interday (long-term) reproducibility of repeated measurements of the depth and diameter of peripheral superficial veins.
METHODS
Twenty-three healthy young women (mean age, 21.7 ± 0.8 years) participated in the study to examine the short- and long-term reproducibility of the depth and diameter of the cutaneous vein in the left elbow fossa acquired by ultrasound imaging. Short-term measurement intervals were 10 s, and the probe was released from the skin for each acquisition, which was repeated five consecutive times. Long-term measurements were performed at the same time on the next day following the same procedure. The acquired images were analyzed for vein depth and diameter using ImageJ software. The intraclass correlation coefficient (ICC) was calculated to determine the short- and long-term reproducibility of the measurements. The relationship between the venous depth and venous diameter intra-individual variation was analyzed, as well as the influence of body composition (body fat and muscle mass) on the venous diameter and depth.
RESULTS
For vein depth measurements, the short- and long-term ICCs were 0.94-0.96 and 0.88, respectively. For the vein diameter, the short- and long-term ICCs were 0.94-0.97 and 0.67, respectively. The short-term ICCs for both vein depth and diameter exceeded 0.9, indicating that the ultrasound vascular measurement was sufficiently reliable. However, long-term reproducibility was slightly lower, especially for the vein diameter. No correlation was found between the intra-individual variation of the vein diameter and vein depth. Although the vein diameter and body fat mass uncorrelated, the vein depth and body fat mass significantly correlated (r = 0.675, 95% confidence interval = 0.281-0.830).
CONCLUSIONS
The long-term reproducibility of vein diameters was somewhat lower than that of the short-term reproducibility. This could be attributed to fluctuations in the physiological state of the participant rather than to the instability of the measurement. Therefore, ultrasound measurement of the peripheral superficial vein is sufficiently reliable.
Topics: Humans; Female; Young Adult; Adult; Reproducibility of Results; Ultrasonography; Adipose Tissue; Angiography; Body Composition
PubMed: 36461013
DOI: 10.1186/s12880-022-00945-9 -
Chinese Journal of Traumatology =... 2012Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms including neck pain, headache, weakness and parasthesisas. According to... (Review)
Review
Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms including neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C(1) to C(7) ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C(4) for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (less than or equal to 14 mm in Whites, less than or equal to 12 mm in Japanese, less than or equal to 13.7 mm in Chinese). Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflammatory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this review will be helpful in diagnosing spinal cord and neurological injuries with the geometric parameters of cervical spine in the future.
Topics: Cervical Vertebrae; Humans; Magnetic Resonance Imaging; Spinal Canal; Spinal Cord Injuries; Spinal Stenosis
PubMed: 22300918
DOI: No ID Found -
The Korean Journal of Internal Medicine Jan 2022While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to...
BACKGROUND/AIMS
While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm.
METHODS
The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath.
RESULTS
The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm.
CONCLUSION
We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm.
Topics: Body Mass Index; Coronary Angiography; Female; Hand; Humans; Male; Radial Artery; Ultrasonography
PubMed: 35000375
DOI: 10.3904/kjim.2020.685 -
Northern Clinics of Istanbul 2023The aim of this study was to determine normative reference values for major thoracic arterial vasculature in Turkiye and to evaluate differences according to age and...
OBJECTIVE
The aim of this study was to determine normative reference values for major thoracic arterial vasculature in Turkiye and to evaluate differences according to age and gender.
METHODS
Low-dose unenhanced chest computerized tomography images acquired with pre-diagnosis of COVID-19 between March and June 2020 were evaluated retrospectively. Patients with known chronic lung parenchymal disease, pleural effusion, pneumothorax, chronic diseases such as diabetes, hypertension, obesity, and chronic heart diseases (coronary artery disease, atherosclerosis, congestive heart failure, valve replacement, and arrhythmia) were excluded from the study. The ascending aorta diameter (AAD), descending aorta diameter (DAD), aortic arch diameter (ARCAD), main pulmonary artery diameter (MPAD), right pulmonary artery diameter (RPAD), and the left pulmonary artery diameter (LPAD) were measured in the same sections by standardized methods. The variability of parameters according to age (<40 years; ≥40 years) and gender (male to female) was evaluated by statistical methods. The Student's t test was used to compare the normal distribution according to the given quantitative age and gender, while the data that did not fit the normal distribution were compared with the Mann-Whitney U test. The conformity of the data to the normal distribution was tested with the Kolmogorov-Smirnov, Shapiro-Wilk test, and graphical examinations.
RESULTS
Totally 777 cases between the ages of 18-96 (43.80±15.98) were included in the study. Among these, 52.8% (n=410) were male and 47.2% (n=367) were female. Mean diameters were 28.52±5.13 mm (12-48 mm in range) for AAD, 30.83±5.25 mm (12-52 mm in range) for ARCAD, DAD 21.27±3.57 mm (11-38 mm in range) for DAD; 23.27±4.03 mm (14-40 mm in range) for MPAD, 17.27±3.19 mm (10-30 mm in range) for RPAD, and 17.62±3.06 mm (10-37 mm in range) for LPAD. Statistically significantly higher values were obtained in all diameters for cases over 40 years of age. Similarly, higher values were obtained in all diameters for males compared to females.
CONCLUSION
The diameters of all thoracic main vascular structures are larger in men than in women and increase with age.
PubMed: 37181064
DOI: 10.14744/nci.2021.03206 -
Radiography (London, England : 1995) May 2022To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols.
INTRODUCTION
To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols.
METHODS
Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n = 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, Ecoflex™ silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk Meshmixer™ software. The model was placed in an acid bath for 5 h, then covered in Ecoflex™, which was removed after drying. Both the Ecoflex™ and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans.
RESULTS
The gelatine mixtures had HU values of 130 and 129, Ecoflex™ 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled Ecoflex™ had a mean HU 318 ± 4, noise 47±7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 ± 5, noise 38±4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed.
CONCLUSION
The use of a 3D printed model of the arteries and casting with the Ecoflex™ silicone is the most suitable solution for a custom-designed phantom.
IMPLICATIONS FOR PRACTICE
Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols.
Topics: Animals; Coronary Vessels; Humans; Printing, Three-Dimensional; Radiation Dosage; Silicones; Swine; Tomography, X-Ray Computed
PubMed: 34556417
DOI: 10.1016/j.radi.2021.09.001 -
Journal of Neurotrauma Feb 2017The severe muscle weakness and atrophy measured after human spinal cord injury (SCI) may relate to chronic muscle denervation due to motoneuron death and/or altered...
The severe muscle weakness and atrophy measured after human spinal cord injury (SCI) may relate to chronic muscle denervation due to motoneuron death and/or altered muscle use. The aim of this study was to estimate motoneuron death after traumatic human SCI. The diameter and number of myelinated axons were measured in ventral roots post-mortem because ventral roots contain large diameter (> 7 μm) myelinated axons that typically arise from motoneurons and innervate skeletal muscle. In four cases (SCI levels C7, C8, T4, and L1) involving contusion (n = 3) or laceration (n = 1), there was a significant reduction in the number of large diameter myelinated axons at the lesion epicenter (mean ± standard error [SE]: 45 ± 11% Uninjured), one level above (51 ± 14%), and one (27 ± 12%), two (45 ± 40%), and three (54 ± 23%) levels below the epicenter. Reductions in motoneuron numbers varied by side and case. These deficits result from motoneuron death because the gray matter was destroyed at and near the lesion epicenter. Muscle denervation must ensue. In seven cases, ventral roots at or below the epicenter had large diameter myelinated axons with unusually thin myelin, a sign of incomplete remyelination. The mean ± SE g ratio (axon diameter/fiber diameter) was 0.60 ± 0.01 for axons of all diameters in five above-lesion ventral roots, but increased significantly for large diameter fibers (≥ 12 μm) in three roots at the lesion epicenter. Motoneuron death after human SCI will coarsen muscle force gradation and control, while extensive muscle denervation will stifle activity-based treatments.
Topics: Adult; Back Muscles; Cell Death; Cervical Vertebrae; Female; Humans; Lumbar Vertebrae; Male; Middle Aged; Motor Neurons; Muscle Weakness; Spinal Cord Injuries; Spinal Nerve Roots; Thoracic Vertebrae
PubMed: 27349409
DOI: 10.1089/neu.2015.4374 -
Revista Portuguesa de Cardiologia :... Jul 2023Several studies comparing optical coherence tomography (OCT) and intravascular ultrasound (IVUS) have revealed that OCT consistently provides smaller area and diameter...
INTRODUCTION AND OBJECTIVES
Several studies comparing optical coherence tomography (OCT) and intravascular ultrasound (IVUS) have revealed that OCT consistently provides smaller area and diameter measurements. However, comparative assessment in clinical practice is difficult. Three-dimensional (3D) printing offers a unique opportunity to assess intravascular imaging modalities. We aim to compare intravascular imaging modalities using a 3D-printed coronary artery in a realistic simulator and to assess whether OCT underestimates intravascular dimensions, exploring potential corrections.
METHODS
A standard realistic left main anatomy with an ostial left anterior descending artery lesion was replicated using 3D printing. After provisional stenting and optimization, IVI was obtained. Modalities included 20 MHz digital IVUS, 60 MHz rotational IVUS (HD-IVUS) and OCT. We assessed luminal area and diameters at standard locations.
RESULTS
Considering all coregistered measurements, OCT significantly underestimated area, minimal diameter and maximal diameter measurements in comparison to IVUS and HD-IVUS (p<0.001). No significant differences were found between IVUS and HD-IVUS. A significant systematic dimensional error was found in OCT auto-calibration by comparing known reference diameter of guiding catheter (1.8 mm) to measured mean diameter (1.68 mm±0.04 mm). By applying a correction factor based on the reference guiding catheter area to OCT, the luminal areas and diameters were not significantly different compared to IVUS and HD-IVUS.
CONCLUSION
Our findings suggest that automatic spectral calibration method for OCT is inaccurate, with a systematic underestimation of luminal dimensions. When guiding catheter correction is applied the performance of OCT is significantly improved. These results may be clinically relevant and need to be validated.
Topics: Humans; Coronary Artery Disease; Predictive Value of Tests; Ultrasonography, Interventional; Heart; Coronary Vessels; Tomography, Optical Coherence
PubMed: 36893842
DOI: 10.1016/j.repc.2023.03.001