-
Journal of Neural Engineering Mar 2021Intracortical microelectrodes are an important tool for neuroscience research and have great potential for clinical use. However, the use of microelectrode arrays to...
Intracortical microelectrodes are an important tool for neuroscience research and have great potential for clinical use. However, the use of microelectrode arrays to treat neurological disorders and control prosthetics is limited by biological challenges such as glial scarring, which can impair chronic recording performance. Microglia activation is an early and prominent contributor to glial scarring. After insertion of an intracortical microelectrode, nearby microglia transition into a state of activation, migrate, and encapsulate the device. Na/Hexchanger isoform-1 (NHE-1) is involved in various microglial functions, including their polarity and motility, and has been implicated in pro-inflammatory responses to tissue injury. HOE-642 (cariporide) is an inhibitor of NHE-1 and has been shown to depress microglial activation and inflammatory response in brain injury models.In this study, the effects of HOE-642 treatment on microglial interactions to intracortical microelectrodes was evaluated using two-photon microscopy.The rate at which microglia processes and soma migrate in response to electrode implantation was unaffected by HOE-642 administration. However, HOE-642 administration effectively reduced the radius of microglia activation at 72 h post-implantation from 222.2m to 177.9m. Furthermore, treatment with HOE-642 significantly reduced microglial encapsulation of implanted devices at 5 h post-insertion from 50.7 ± 6.0% to 8.9 ± 6.1%, which suggests an NHE-1-specific mechanism mediating microglia reactivity and gliosis during implantation injury.This study implicates NHE-1 as a potential target of interest in microglial reactivity and HOE-642 as a potential treatment to attenuate the glial response and scar formation around implanted intracortical microelectrodes.
Topics: Cicatrix; Humans; Microelectrodes; Microglia; Neuroglia; Sodium-Hydrogen Exchangers
PubMed: 33621208
DOI: 10.1088/1741-2552/abe8f1 -
Biomaterials Jan 2021Devices implanted within the central nervous system (CNS) are subjected to tissue reactivity due to the lack of biocompatibility between implanted material and the...
Devices implanted within the central nervous system (CNS) are subjected to tissue reactivity due to the lack of biocompatibility between implanted material and the cells' microenvironment. Studies have attributed blood-brain barrier disruption, inflammation, and oxidative stress as main contributing factors that lead to electrode recording failure. The complement cascade is a part of the innate immunity that focuses on recognizing and targeting foreign objects; however, its role in the context of neural implants is substantially unknown. In this study, we implanted a non-functional 4x4 Utah microelectrode array (UEA) into the somatosensory cortex and studied the complement cascade via combined gene and immunohistochemistry quantification at acute (48-h), sub-acute (1-week), and early chronic (4-weeks) time points. The results of this study demonstrate the activation and continuation of the complement cascade at the electrode-tissue interface, illustrating the therapeutic potential of modulating the foreign body response via the complement cascade.
Topics: Electrodes, Implanted; Foreign Bodies; Humans; Inflammation; Microelectrodes; Utah
PubMed: 33310540
DOI: 10.1016/j.biomaterials.2020.120583 -
Biomedical Engineering Online Aug 2019Microelectrode arrays play an important role in prosthetic implants for neural signal recording or applying electrical pulses stimulation to target nerve system. Safety...
BACKGROUND
Microelectrode arrays play an important role in prosthetic implants for neural signal recording or applying electrical pulses stimulation to target nerve system. Safety and long-term reliability are essential requirements for microelectrode arrays applied in electrical stimulation. In design and fabrication of the microelectrode array, soft materials are generally chosen to be the substrate for the aim of achieving better compliance with the surrounding tissue while maintaining minimal damage. By flexing of the array to the surface, the array is capable of keeping a more stable electrical contact resulting in a significantly improved signal detected.
METHODS
In this study, we design and fabricate a flexible microelectrode array with gold as the electrode material and parylene-C as the substrate. The fabrication process of the array is presented. The in vitro electrochemical characteristics of the microelectrode are investigated by electrochemical impedance spectroscopy and cyclic voltammetry in a three-electrode electrochemical cell containing phosphate-buffered saline. Charge injection capacity measurements are carried out by multichannel systems and the CSC of the microarray is calculated.
RESULTS
Electrochemical results showed that impedance decreased with frequency. The average impedance of the Au electrodes at 1 kHz was 36.54 ± 0.88 kΩ. The average phase angle at 1 kHz was - 73.52 ± 1.3°, and the CIC of the microelectrode was 22.3 µC/cm. The results demonstrated that the microelectrode array performed as expected for neuronal signal recording or stimulation.
CONCLUSIONS
With parylene-C as the substrate, the microarray has good flexibility. The electrochemical characteristics' results show that the array has the ability to resist any corrosion on metal-electrolyte interface and has good biocompatibility. This low-cost, flexible parylene-based, gold microelectrode array shows potential for use in implant neurological signal acquisition or neurostimulation applications.
Topics: Dielectric Spectroscopy; Electric Stimulation; Electrochemistry; Equipment Design; Gold; Mechanical Phenomena; Microelectrodes; Polymers; Reproducibility of Results; Xylenes
PubMed: 31370902
DOI: 10.1186/s12938-019-0704-8 -
Biosensors Apr 2022With the increasing demand for fast, accurate, and reliable biological sensor systems, miniaturized systems have been aimed at droplet-based sensor systems and have been...
With the increasing demand for fast, accurate, and reliable biological sensor systems, miniaturized systems have been aimed at droplet-based sensor systems and have been promising. A micro-electrode dot array (MEDA) biochip, which is one kind of the miniaturized systems for biochemical protocols such as dispensing, dilutions, mixing, and so on, has become widespread due to enabling dynamical control of the droplets in microfluidic manipulations. In MEDA biochips, the electrowetting-on-dielectric (EWOD) technique stands out since it can actuate droplets with nano/picoliter volumes. Microelectrode cells on MEDA actuate multiple droplets simultaneously to route locations for the purpose of the biochemical operations. Taking advantage of the feature, droplets are often routed in parallel to achieve high-throughput outcomes. Regarding parallel manipulation of multiple droplets, however, the droplets are known to be initially placed at a distant position to avoid undesirable mixing. The droplets thus result in traveling a long way for a manipulation, and the required biochip size for routing is also enlarged. This paper proposes a routing method for droplets to reduce the biochip size on a MEDA biochip with the allowance of splitting during routing operations. We mathematically derive the routing problem, and the experiments demonstrate that our proposal can significantly reduce the biochip size by 70.8% on average, compared to the state-of-the-art method.
Topics: Biosensing Techniques; Electrowetting; Microelectrodes; Microfluidic Analytical Techniques
PubMed: 35624578
DOI: 10.3390/bios12050277 -
Biosensors Jul 2022Nowadays, bioelectronic devices are evolving from rigid to flexible materials and substrates, among which thermally-drawn-fiber-based bioelectronics represent promising...
Nowadays, bioelectronic devices are evolving from rigid to flexible materials and substrates, among which thermally-drawn-fiber-based bioelectronics represent promising technologies thanks to their inherent flexibility and seamless integration of multi-functionalities. However, electrochemical sensing within fibers remains a poorly explored area, as it imposes new demands for material properties-both the electrochemical sensitivity and the thermomechanical compatibility with the fiber drawing process. Here, we designed and fabricated microelectrode fibers made of carbon nanotube (CNT)-based hybrid nanocomposites and further evaluated their detailed electrochemical sensing performances. Carbon-black-impregnated polyethylene (CB-CPE) was chosen as the base material, into which CNT was loaded homogeneously in a concentration range of 3.8 to 10 wt%. First, electrical impedance characterization of CNT nanocomposites showed a remarkable decrease of the resistance with the increase in CNT loading ratio, suggesting that CNTs notably increased the effective electrical current pathways inside the composites. In addition, the proof-of-principle performance of fiber-based microelectrodes was characterized for the detection of ferrocenemethanol (FcMeOH) and dopamine (DA), exhibiting an ultra-high sensitivity. Additionally, we further examined the long-term stability of such composite-based electrode in exposure to the aqueous environment, mimicking the in vivo or in vitro settings. Later, we functionalized the surface of the microelectrode fiber with ion-sensitive membranes (ISM) for the selective sensing of Na+ ions. The miniature fiber-based electrochemical sensor developed here holds great potential for standalone point-of-care sensing applications. In the future, taking full advantage of the thermal drawing process, the electrical, optical, chemical, and electrochemical modalities can be all integrated together within a thin strand of fiber. This single fiber can be useful for fundamental multi-mechanistic studies for biological applications and the weaved fibers can be further applied for daily health monitoring as functional textiles.
Topics: Carbon Fiber; Dopamine; Microelectrodes; Nanocomposites; Nanotubes, Carbon
PubMed: 35892456
DOI: 10.3390/bios12080559 -
Advanced Science (Weinheim,... Jul 2021Advanced optical imaging techniques address important biological questions in neuroscience, where structures such as synapses are below the resolution limit of a...
Advanced optical imaging techniques address important biological questions in neuroscience, where structures such as synapses are below the resolution limit of a conventional microscope. At the same time, microelectrode arrays (MEAs) are indispensable in understanding the language of neurons. Here, the authors show transparent MEAs capable of recording action potentials from neurons and compatible with advanced microscopy. The electrodes are made of the conducting polymer poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) and are patterned by optical lithography, ensuring scalable fabrication with good control over device parameters. A thickness of 380 nm ensures low enough impedance and >75% transparency throughout the visible part of the spectrum making them suitable for artefact-free recording in the presence of laser illumination. Using primary neuronal cells, the arrays record single units from multiple nearby sources with a signal-to-noise ratio of 7.7 (17.7 dB). Additionally, it is possible to perform calcium (Ca) imaging, a measure of neuronal activity, using the novel transparent electrodes. Different biomarkers are imaged through the electrodes using conventional and super-resolution microscopy (SRM), showing no qualitative differences compared to glass substrates. These transparent MEAs pave the way for harnessing the synergy between the superior temporal resolution of electrophysiology and the selectivity and high spatial resolution of optical imaging.
Topics: Cardiac Electrophysiology; Electrophysiological Phenomena; Microelectrodes; Microscopy; Polymers
PubMed: 36246164
DOI: 10.1002/advs.202004434 -
Lab on a Chip Mar 2022Electrode-based impedance and electrochemical measurements can provide cell-biology information that is difficult to obtain using optical-microscopy techniques. Such...
Electrode-based impedance and electrochemical measurements can provide cell-biology information that is difficult to obtain using optical-microscopy techniques. Such electrical methods are non-invasive, label-free, and continuous, eliminating the need for fluorescence reporters and overcoming optical imaging's throughput/temporal resolution limitations. Nonetheless, electrode-based techniques have not been heavily employed because devices typically contain few electrodes per well, resulting in noisy aggregate readouts. Complementary metal-oxide-semiconductor (CMOS) microelectrode arrays (MEAs) have sometimes been used for electrophysiological measurements with thousands of electrodes per well at sub-cellular pitches, but only basic impedance mappings of cell attachment have been performed outside of electrophysiology. Here, we report on new field-based impedance mapping and electrochemical mapping/patterning techniques to expand CMOS-MEA cell-biology applications. The methods enable accurate measurement of cell attachment, growth/wound healing, cell-cell adhesion, metabolic state, and redox properties with single-cell spatial resolution (20 μm electrode pitch). These measurements allow the quantification of adhesion and metabolic differences of cells expressing oncogenes wild-type controls. The multi-parametric, cell-population statistics captured by the chip-scale integrated device opens up new avenues for fully electronic high-throughput live-cell assays for phenotypic screening and drug discovery applications.
Topics: Cell Culture Techniques; Electrophysiological Phenomena; Microelectrodes; Oxides; Semiconductors
PubMed: 35266462
DOI: 10.1039/d1lc00878a -
Scientific Reports Aug 2022Long-term implantable neural interfacing devices are able to diagnose, monitor, and treat many cardiac, neurological, retinal and hearing disorders through nerve...
Long-term implantable neural interfacing devices are able to diagnose, monitor, and treat many cardiac, neurological, retinal and hearing disorders through nerve stimulation, as well as sensing and recording electrical signals to and from neural tissue. To improve specificity, functionality, and performance of these devices, the electrodes and microelectrode arrays-that are the basis of most emerging devices-must be further miniaturized and must possess exceptional electrochemical performance and charge exchange characteristics with neural tissue. In this report, we show for the first time that the electrochemical performance of femtosecond-laser hierarchically-restructured electrodes can be tuned to yield unprecedented performance values that significantly exceed those reported in the literature, e.g. charge storage capacity and specific capacitance were shown to have improved by two orders of magnitude and over 700-fold, respectively, compared to un-restructured electrodes. Additionally, correlation amongst laser parameters, electrochemical performance and surface parameters of the electrodes was established, and while performance metrics exhibit a relatively consistent increasing behavior with laser parameters, surface parameters tend to follow a less predictable trend negating a direct relationship between these surface parameters and performance. To answer the question of what drives such performance and tunability, and whether the widely adopted reasoning of increased surface area and roughening of the electrodes are the key contributors to the observed increase in performance, cross-sectional analysis of the electrodes using focused ion beam shows, for the first time, the existence of subsurface features that may have contributed to the observed electrochemical performance enhancements. This report is the first time that such performance enhancement and tunability are reported for femtosecond-laser hierarchically-restructured electrodes for neural interfacing applications.
Topics: Cross-Sectional Studies; Electrodes; Electrodes, Implanted; Lasers; Microelectrodes; Nerve Tissue; Nervous System
PubMed: 35978090
DOI: 10.1038/s41598-022-18161-4 -
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi =... Apr 2020As an interface between external electronic devices and internal neural nuclei, microelectrodes play an important role in many fields, such as animal robots, deep brain...
As an interface between external electronic devices and internal neural nuclei, microelectrodes play an important role in many fields, such as animal robots, deep brain stimulation and neural prostheses. Aiming at the problem of high price and complicated fabrication process of microelectrode, a microelectrode twisting machine based on open source electronic prototyping platform (Arduino) and three-dimensional printing technology was proposed, and its microelectrode fabrication performance and neural stimulation performance were verified. The results show that during the fabrication of microelectrodes, the number of positive twisting turns of the electrode wire should generally be set to about 1.8 times of its length, and the number of reverse twisting rings is independent of the length, generally about 5. Moreover, compared with the traditional instrument, the device is not only inexpensive and simple to manufacture, but also has good expandability. It has a positive significance for both the personalization and popularization of microelectrode fabrication and the reduction of experimental cost.
Topics: Equipment Design; Microelectrodes; Printing, Three-Dimensional
PubMed: 32329285
DOI: 10.7507/1001-5515.201908058 -
Frontiers in Neural Circuits 2022Cascading activity is commonly observed in complex dynamical systems, including networks of biological neurons, and how these cascades spread through the system is...
Cascading activity is commonly observed in complex dynamical systems, including networks of biological neurons, and how these cascades spread through the system is reliant on how the elements of the system are connected and organized. In this work, we studied networks of neurons as they matured over 50 days and evaluated both their dynamics and their functional connectivity structures by observing their electrophysiological activity using microelectrode array recordings. Correlations were obtained between features of their activity propagation and functional connectivity characteristics to elucidate the interplay between dynamics and structure. The results indicate that networks maintain a slightly subcritical state by striking a balance between integration and segregation. Our work demonstrates the complementarity of these two approaches-functional connectivity and avalanche dynamics-in studying information propagation in neurons , which can in turn inform the design and optimization of engineered computational substrates.
Topics: Microelectrodes; Nerve Net; Neurons
PubMed: 36188125
DOI: 10.3389/fncir.2022.980631