JMIR Research Protocols May 2024The population is constantly aging, and most older adults will experience many potential physiological changes as they age, leading to functional decline. Urinary and...
Finite Element Analysis of Pelvic Floor Biomechanical Models to Elucidate the Mechanism for Improving Urination and Defecation Dysfunction in Older Adults: Protocol for a Model Development and Validation Study.
BACKGROUND
The population is constantly aging, and most older adults will experience many potential physiological changes as they age, leading to functional decline. Urinary and bowel dysfunction is the most common obstacle in older people. At present, the analysis of pelvic floor histological changes related to aging has not been fully elucidated, and the mechanism of improving intestinal control ability in older people is still unclear.
OBJECTIVE
The purpose of this study is to describe how the finite element method will be used to understand the mechanical characteristics of and physiological changes in the pelvic cavity during the rehabilitation process, providing theoretical support for the mechanism for improving urination and defecation dysfunction in older individuals.
METHODS
We will collect magnetic resonance imaging (MRI) and computed tomography (CT) data of the pelvic cavity of one male and one female volunteer older than 60 years and use the finite element method to construct a 3D computer simulation model of the pelvic cavity. By simulating different physiological states, such as the Valsalva maneuver and bowel movement, we will verify the accuracy of the constructed model, investigate the effects of different neuromuscular functional changes, and quantify the impact proportions of the pelvic floor muscle group, core muscle group, and sacral nerve.
RESULTS
At present, we have registered the study in the Chinese Clinical Trial Registry and collected MRI and CT data for an older male and an older female patient. Next, the construction and analysis of the finite element model will be accomplished according to the study plan. We expect to complete the construction and analysis of the finite element model by July 2024 and publish the research results by October 2025.
CONCLUSIONS
Our study will build finite element models of the pelvic floor of older men and older women, and we shall elucidate the relationship between the muscles of the pelvic floor, back, abdomen, and hips and the ability of older adults to control bowel movements. The results of this study will provide theoretical support for elucidating the mechanism for improving urination and defecation dysfunction through rehabilitation.
TRIAL REGISTRATION
Chinese Clinical Trial Registry ChiCTR2400080749; https://www.chictr.org.cn/showproj.html?proj=193428.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID)
DERR1-10.2196/56333.
Topics: Humans; Male; Female; Finite Element Analysis; Pelvic Floor; Aged; Biomechanical Phenomena; Defecation; Middle Aged; Urination; Magnetic Resonance Imaging; Computer Simulation
PubMed: 38820582
DOI: 10.2196/56333 -
PloS One 2024Clinicians commonly use manual therapy to treat low back pain by palpating the spine to identify the spinous processes. This study aims to evaluate the ability of... (Randomized Controlled Trial)
Randomized Controlled Trial
INTRODUCTION
Clinicians commonly use manual therapy to treat low back pain by palpating the spine to identify the spinous processes. This study aims to evaluate the ability of experienced clinicians to consistently locate the spinous processes from S1 to T12 through palpation. The results will be compared to topographical data representing the lumbar lordosis at baseline and four follow-up time points.
MATERIALS AND METHODS
In a prior prospective randomized trial, experienced clinicians used palpation to locate the lumbar spinous processes (S1-T12) and then digitized these locations in three-dimensional space. The same digitizing equipment was then used to continuously collect three-dimensional position data of a wheel that rolled along the back's surface through a trajectory that connected the previously digitized locations of the spinous processes. This process was repeated at 4 days, 1, 4, and 12 weeks. The resulting lordosis trajectories were plotted and aligned using the most anterior point in the lordosis to compare the locations of the spinous processes identified in different trials. This way, spinous palpation points could be compared to surface topography over time. Intra- and interrater reliability and agreement were estimated using intraclass correlations of agreement and Bland-Altman limits of agreement.
RESULTS
Five clinicians palpated a total of 119 participants. The results showed a large degree of variation in precision estimates, with a mean total value of 13 mm (95%CI = 11;15). This precision error was consistent across all time points. The smallest precision error was found at L5, followed by S1 File, after which the error increased superiorly. Intra- and interrater reliability was poor to moderate.
CONCLUSIONS
Comparison of palpation results to a topographic standard representing the lumbar lordosis is a new approach for evaluating palpation. Our results confirm the results of prior studies that find palpation of lumbar spinous processes imprecise, even for experienced clinicians.
Topics: Humans; Palpation; Lumbar Vertebrae; Female; Male; Lordosis; Adult; Low Back Pain; Prospective Studies; Middle Aged
PubMed: 38814967
DOI: 10.1371/journal.pone.0304571 -
PloS One 2024The present study aimed to assess the use of technical-tactical variables and machine learning (ML) classifiers in the automatic classification of the passing difficulty...
Who are the best passing players in professional soccer? A machine learning approach for classifying passes with different levels of difficulty and discriminating the best passing players.
The present study aimed to assess the use of technical-tactical variables and machine learning (ML) classifiers in the automatic classification of the passing difficulty (DP) level in soccer matches and to illustrate the use of the model with the best performance to distinguish the best passing players. We compared eight ML classifiers according to their accuracy performance in classifying passing events using 35 technical-tactical variables based on spatiotemporal data. The Support Vector Machine (SVM) algorithm achieved a balanced accuracy of 0.70 ± 0.04%, considering a multi-class classification. Next, we illustrate the use of the best-performing classifier in the assessment of players. In our study, 2,522 pass actions were classified by the SVM algorithm as low (53.9%), medium (23.6%), and high difficulty passes (22.5%). Furthermore, we used successful rates in low-DP, medium-DP, and high-DP as inputs for principal component analysis (PCA). The first principal component (PC1) showed a higher correlation with high-DP (0.80), followed by medium-DP (0.73), and low-DP accuracy (0.24). The PC1 scores were used to rank the best passing players. This information can be a very rich performance indication by ranking the best passing players and teams and can be applied in offensive sequences analysis and talent identification.
Topics: Soccer; Humans; Athletic Performance; Machine Learning; Support Vector Machine; Principal Component Analysis; Algorithms
PubMed: 38814958
DOI: 10.1371/journal.pone.0304139 -
The bone nonunion microenvironment: A place where osteogenesis struggles with osteoclastic capacity.Heliyon May 2024Bone nonunion is a common and serious orthopedic disorder, the occurrence of which is associated with a disruption of the dynamic balance between osteoblasts and... (Review)
Review
Bone nonunion is a common and serious orthopedic disorder, the occurrence of which is associated with a disruption of the dynamic balance between osteoblasts and osteoclasts during bone repair. However, the critical molecular mechanisms affecting this homeostasis are not well understood, and it is essential to investigate the specific components of this mechanism and to restore the balance between osteoblasts and osteoclasts to promote bone repair. First, we defined this complex local environmental factor as the "bone nonunion microenvironment" and identified the importance of the "struggle" between osteoblasts and osteoclasts, which is the most essential element in determining the process of . On this basis, we also explored the cellular factors that influence osteogenesis and the molecular signals that influence the balance between and osteoblasts, which are important for restoring homeostasis. Further, we explored other factors involved in osteogenesis, such as the biomechanical environment, the nutritional environment, the acid-base environment, and the temperature environment, which are important players in osteogenesis. In conclusion, we found that the balance between osteoblasts and osteoclasts is the essence of bone healing, which is based on the "bone nonunion microenvironment". Therefore, investigating the role of the bone nonunion microenvironment in the system of osteoblast-osteoclast "struggle" provides an important basis for further understanding of the mechanism of nonunion and the development of new therapeutic approaches.
PubMed: 38813209
DOI: 10.1016/j.heliyon.2024.e31314 -
Heliyon May 2024The objective of this study was to explore the braking technical characteristics of the swing leg of elite male athletes in long jump take-off and its dependencies on...
The objective of this study was to explore the braking technical characteristics of the swing leg of elite male athletes in long jump take-off and its dependencies on the extension velocity of the support leg and the balance. Two cameras were used to capture 8 elite male long jump athletes (25.88 ± 3.00 years) under competitive conditions at a National Indoor Athletic Championships Final, a 3-D kinematic analysis method was conducted to analyze the take-off technique of the athletes. The results showed that the rapid braking of the swing leg increased the extension velocity of the support leg. Compared to the swing leg that started braking at the moment of maximum knee flexion of the support leg (SPKnee maximum flexion moment), athletes' performance was greater when swing leg started braking at the moment of maximum ankle flexion of the support leg (SPAnkle maximum flexion moment). Furthermore, the swing leg exhibited an inward movement during its forward swing, and the inward angle was significantly correlated with the balance maintenance (r = - 0.50,P = 0.004). In conclusion, a relatively delayed rapid braking and moderate inward movement of the swing leg during the take-off phase are conducive to achieving a better take-off effect in long jump.
PubMed: 38813208
DOI: 10.1016/j.heliyon.2024.e31015 -
Heliyon May 2024Change of femoral neck ante-version angle postoperatively due to inadequate reduction could result in unsatisfying treatment outcome of intertrochanteric fracture....
OBJECTIVE
Change of femoral neck ante-version angle postoperatively due to inadequate reduction could result in unsatisfying treatment outcome of intertrochanteric fracture. However, the influence of increased or decreased femoral neck ante-version on the biomechanical stability of the bone-implant complex has rarely been studied.
METHODS
A finite element model of a complete normal human femur with normal femoral neck ante-version as 13° was established accurately by scanning a 64 year old female femur. The models of 31-A1.1 intertrochanteric fractures with different femoral neck ante-version angles of 3°, 5.5°, 8°, 10.5°, 13°, 15.5°, 18°, 20.5°, 23° were created. They were assembled with a proximal femoral nail anti-rotation (PFNA) device. The biomechanical differences with varying femoral neck ante-version angles were compared using finite element analysis method.
RESULTS
As the femoral neck ante-version angle gradually increased from 13° to 23°with a gradient of 2.5°, the peak von Mises stress was gradually increased from 137.82 MPa to 276.02 MPa. Similarly, the peak von Mises stress was gradually increased from 137.82 MPa to 360.12 MPa with the femoral neck ante-version angle decreased from 13° to 3°. When decreased ante-version angle of 7.5° and increased ante-version angle of 10° will exceed the yield strength of femoral (240.32 MPa), the risk of femoral fracture will increase significantly. The maximum displacement of the femur was significantly reduced for increased ante-version models than for decreased ante-version models, whether the changes of ante-version angles were 2.5°, 5°, 7.5° or 10°. he maximum stress of PFNA was found in the intersection of main nail and helical blade, and became greater gradually as the ante-version angle increased or decreased with a gradient of 2.5°. The maximum stress of PFNA was presented in the model 5.5° with the maximum stress of 724.42 MPa (near to the yield strength of titanium alloy of 700-1000 MPa), producing the breakage risk of PFNA. The maximum displacement of the PFNA was significantly reduced for increased ante-version models than for decreased ante-version models, whether the changes of ante-version angles were 2.5°, 5°, 7.5° or 10°.
CONCLUSION
Based on the results of present study, it was demonstrated that the anatomical reduction of femoral neck ante-version was vital to secure the optimal stability. Abnormal femoral ante-version could increase the potential risk of failure for intertrochanteric fracture after PFNA. The stability of increased femoral ante-version (less than 10°) was superior to the stability of decreased ante-version (less than 5°) for the cases of difficulty to acquire anatomical reduction. The clinical implication of the finding was that increased femoral neck ante-version had an advantage of mechanical stability towards the decreased femoral neck ante-version for the cases of comminuted intertrochanteric fracture and failure of anatomical reduction.
PubMed: 38813167
DOI: 10.1016/j.heliyon.2024.e31480 -
Frontiers in Neuroscience 2024The human's upright standing is a complex control process that is not yet fully understood. Postural control models can provide insights into the body's internal control...
The human's upright standing is a complex control process that is not yet fully understood. Postural control models can provide insights into the body's internal control processes of balance behavior. Using physiologically plausible models can also help explaining pathophysiological motion behavior. In this paper, we introduce a neuromusculoskeletal postural control model using sensor feedback consisting of somatosensory, vestibular and visual information. The sagittal plane model was restricted to effectively six degrees of freedom and consisted of nine muscles per leg. Physiologically plausible neural delays were considered for balance control. We applied forward dynamic simulations and a single shooting approach to generate healthy reactive balance behavior during quiet and perturbed upright standing. Control parameters were optimized to minimize muscle effort. We showed that our model is capable of fulfilling the applied tasks successfully. We observed joint angles and ranges of motion in physiologically plausible ranges and comparable to experimental data. This model represents the starting point for subsequent simulations of pathophysiological postural control behavior.
PubMed: 38812972
DOI: 10.3389/fnins.2024.1393749 -
North American Spine Society Journal Jun 2024In anterior lumbar interbody fusion (ALIF), the use of integrated screws is attractive to surgeons because of the ease of implantation and no additional profile....
BACKGROUND
In anterior lumbar interbody fusion (ALIF), the use of integrated screws is attractive to surgeons because of the ease of implantation and no additional profile. However, the number and length of screws necessary for safe and stable implantation in various bone densities is not yet fully understood. The current study aims to determine how important both length and number of screws are for stability of ALIFs.
METHODS
Three bone models with densities of 10, 15, and 20 pounds per cubic foot (PCF) were chosen as surrogates. These were instrumented using the Z-Link lumbar interbody system with either 2, 3, or 4 integrated 4.5 × 20 mm screws or 4.5 × 25 mm screws (Zavation, LLC, Flowood, MS). The bone surrogates were tested with loading conditions resulting in spine extension to measure construct stiffness and peak force.
RESULTS
The failure load of the construct was influenced by the length of screws (p=.01) and density of the bone surrogate (p<.01). There was no difference in failure load between using 2 screws and 3 screws (p=.32) or when using four 20 mm screws versus three 25 mm screws (p=.295).
CONCLUSION
In our study, both bone density and length of screws significantly affected the construct's load to failure. In certain cases where a greater number of screws are unable to be implanted, the same stability can potentially be conferred with use of longer screws. Future clinical studies should be performed to test these biomechanical results.
PubMed: 38812953
DOI: 10.1016/j.xnsj.2024.100325 -
Frontiers in Bioengineering and... 2024The objective of the present study is to conduct a comparative analysis of the biomechanical advantages and disadvantages associated with a biplanar double support screw...
OBJECTIVE
The objective of the present study is to conduct a comparative analysis of the biomechanical advantages and disadvantages associated with a biplanar double support screw (BDSF) internal fixation device.
METHODS
Two distinct femoral neck fracture models, one with a 30° angle and the other with a 70° angle, were created using a verified and effective finite element model. Accordingly, a total of eight groups of finite element models were utilized, each implanted with different configurations of fixation devices, including distal screw 150° BDSF, distal screw 165° BDSF, 3 CLS arranged in an inverted triangle configuration, and 4 CLS arranged in a "α" configuration. Subsequently, the displacement and distribution of Von Mises stress (VMS) in the femur and internal fixation device were assessed in each fracture group under an axial load of 2100 N.
RESULTS
At Pauwels 30° Angle, the femur with a 150°-BDSF orientation exhibited a maximum displacement of 3.17 mm, while the femur with a 165°-BDSF orientation displayed a maximum displacement of 3.13 mm. When compared with the femoral neck fracture model characterized by a Pauwels Angle of 70°, the shear force observed in the 70° model was significantly higher than that in the 30° model. Conversely, the stability of the 30° model was significantly superior to that of the 70° model. Furthermore, in the 70° model, the BDSF group exhibited a maximum femur displacement that was lower than both the 3CCS (3.46 mm) and 4CCS (3.43 mm) thresholds.
CONCLUSION
The biomechanical properties of the BDSF internal fixation device are superior to the other two hollow screw internal fixation devices. Correspondingly, superior biomechanical outcomes can be achieved through the implementation of distal screw insertion at an angle of 165°. Thus, the BDSF internal fixation technique can be considered as a viable closed reduction internal fixation technique for managing femoral neck fractures at varying Pauwels angles.
PubMed: 38812913
DOI: 10.3389/fbioe.2024.1358181 -
Frontiers in Bioengineering and... 2024To study the ability of theaflavin-3,3'-digallate (TF3)/ethanol solution to crosslink demineralized dentin collagen, resist collagenase digestion, and explore the...
OBJECTIVES
To study the ability of theaflavin-3,3'-digallate (TF3)/ethanol solution to crosslink demineralized dentin collagen, resist collagenase digestion, and explore the potential mechanism.
METHODS
Fully demineralized dentin blocks were prepared using human third molars that were caries-free. Then, these blocks were randomly allocated into 14 separate groups (n = 6), namely, control, ethanol, 5% glutaraldehyde (GA), 12.5, 25, 50, and 100 mg/ml TF3/ethanol solution groups. Each group was further divided into two subgroups based on crosslinking time: 30 and 60 s. The efficacy and mechanism of TF3's interaction with dentin type I collagen were predicted through molecular docking. The cross-linking, anti-enzymatic degradation, and biomechanical properties were studied by weight loss, hydroxyproline release, scanning/transmission electron microscopy (SEM/TEM), zymography, surface hardness, thermogravimetric analysis, and swelling ratio. Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy were utilized to explore its mechanisms. Statistical analysis was performed using one and two-way analysis of variance and Tukey's test.
RESULTS
TF3/ethanol solution could effectively crosslink demineralized dentin collagen and improve its resistance to collagenase digestion and biomechanical properties ( < 0.05), showing concentration and time dependence. The effect of 25 and 50 mg/ml TF3/ethanol solution was similar to that of 5% GA, whereas the 100 mg/mL TF3/ethanol solution exhibited better performance ( < 0.05). TF3 and dentin type I collagen are mainly cross-linked by hydrogen bonds, and there may be covalent and hydrophobic interactions.
CONCLUSION
TF3 has the capability to efficiently cross-link demineralized dentin collagen, enhancing its resistance to collagenase enzymatic hydrolysis and biomechanical properties within clinically acceptable timeframes (30 s/60 s). Additionally, it exhibits promise in enhancing the longevity of dentin adhesion.
PubMed: 38812911
DOI: 10.3389/fbioe.2024.1401032