MASCC/ISOO clinical practice guidelines for the management of mucositis secondary to cancer therapy.Cancer May 2014Mucositis is a highly significant, and sometimes dose-limiting, toxicity of cancer therapy. The goal of this systematic review was to update the Multinational... (Review)
Review
BACKGROUND
Mucositis is a highly significant, and sometimes dose-limiting, toxicity of cancer therapy. The goal of this systematic review was to update the Multinational Association of Supportive Care in Cancer and International Society of Oral Oncology (MASCC/ISOO) Clinical Practice Guidelines for mucositis.
METHODS
A literature search was conducted to identify eligible published articles, based on predefined inclusion/exclusion criteria. Each article was independently reviewed by 2 reviewers. Studies were rated according to the presence of major and minor flaws as per previously published criteria. The body of evidence for each intervention, in each treatment setting, was assigned a level of evidence, based on previously published criteria. Guidelines were developed based on the level of evidence, with 3 possible guideline determinations: recommendation, suggestion, or no guideline possible.
RESULTS
The literature search identified 8279 papers, 1032 of which were retrieved for detailed evaluation based on titles and abstracts. Of these, 570 qualified for final inclusion in the systematic reviews. Sixteen new guidelines were developed for or against the use of various interventions in specific treatment settings. In total, the MASCC/ISOO Mucositis Guidelines now include 32 guidelines: 22 for oral mucositis and 10 for gastrointestinal mucositis. This article describes these updated guidelines.
CONCLUSIONS
The updated MASCC/ISOO Clinical Practice Guidelines for mucositis will help clinicians provide evidence-based management of mucositis secondary to cancer therapy.
Topics: Amifostine; Analgesics; Anti-Infective Agents; Anti-Inflammatory Agents; Anti-Ulcer Agents; Antineoplastic Agents; Cryotherapy; Cytokines; Esophagitis; Evidence-Based Medicine; Humans; Hyperbaric Oxygenation; Intercellular Signaling Peptides and Proteins; Low-Level Light Therapy; Mucositis; Neoplasms; Oral Hygiene; Phototherapy; Proctitis; Protective Agents; Radiation-Protective Agents; Radiotherapy; Stomatitis; Sucralfate
PubMed: 24615748
DOI: 10.1002/cncr.28592 -
BMC Pregnancy and Childbirth Oct 2011Rates of labour induction are increasing. We conducted this systematic review to assess the evidence supporting use of each method of labour induction. (Review)
Review
BACKGROUND
Rates of labour induction are increasing. We conducted this systematic review to assess the evidence supporting use of each method of labour induction.
METHODS
We listed methods of labour induction then reviewed the evidence supporting each. We searched MEDLINE and the Cochrane Library between 1980 and November 2010 using multiple terms and combinations, including labor, induced/or induction of labor, prostaglandin or prostaglandins, misoprostol, Cytotec, 16,16,-dimethylprostaglandin E2 or E2, dinoprostone; Prepidil, Cervidil, Dinoprost, Carboprost or hemabate; prostin, oxytocin, misoprostol, membrane sweeping or membrane stripping, amniotomy, balloon catheter or Foley catheter, hygroscopic dilators, laminaria, dilapan, saline injection, nipple stimulation, intercourse, acupuncture, castor oil, herbs. We performed a best evidence review of the literature supporting each method. We identified 2048 abstracts and reviewed 283 full text articles. We preferentially included high quality systematic reviews or large randomised trials. Where no such studies existed, we included the best evidence available from smaller randomised or quasi-randomised trials.
RESULTS
We included 46 full text articles. We assigned a quality rating to each included article and a strength of evidence rating to each body of literature. Prostaglandin E2 (PGE2) and vaginal misoprostol were more effective than oxytocin in bringing about vaginal delivery within 24 hours but were associated with more uterine hyperstimulation. Mechanical methods reduced uterine hyperstimulation compared with PGE2 and misoprostol, but increased maternal and neonatal infectious morbidity compared with other methods. Membrane sweeping reduced post-term gestations. Most included studies were too small to evaluate risk for rare adverse outcomes.
CONCLUSIONS
Research is needed to determine benefits and harms of many induction methods.
Topics: Administration, Intravaginal; Dinoprostone; Female; Humans; Infusions, Intravenous; Labor, Induced; Misoprostol; Oxytocics; Oxytocin; Pregnancy; Randomized Controlled Trials as Topic; Time Factors
PubMed: 22032440
DOI: 10.1186/1471-2393-11-84 -
Food Science & Nutrition Jan 2019Ginger, the rhizome of Zingiber officinale, which is used as a spice globally has a long history of medicinal use that stimulates investigators to assess its potential... (Review)
Review
Ginger, the rhizome of Zingiber officinale, which is used as a spice globally has a long history of medicinal use that stimulates investigators to assess its potential roles as an adjuvant therapy or alternative medicine in a range of diseases. Anti-inflammatory, antioxidant, antitumor, and antiulcer effects of ginger have been proven in many scientific studies, and some of the ancient applications of ginger as a home remedy has been confirmed in human. In this review, we summarized the current evidence on the effects of ginger consumption on gastrointestinal disorders based on clinical trials. Our data indicate that divided lower daily dosage of 1500 mg ginger is beneficial for nausea relief. Because of limited number of studies on some other gastrointestinal disorders, the results may not be as much powered as to find significant results. Therefore, more extensive and well-controlled human studies of ginger or its standard extracts are required to demonstrate its efficacy as a gastroprotective agent. Dose-finding studies should be undertaken to accurately determine the effective dose and preparation of ginger in further clinical trials protocol.
PubMed: 30680163
DOI: 10.1002/fsn3.807 -
The Cochrane Database of Systematic... Jun 2018Venous leg ulcers are open skin wounds on the lower leg which can be slow to heal, and are both painful and costly. The point prevalence of open venous leg ulcers in the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Venous leg ulcers are open skin wounds on the lower leg which can be slow to heal, and are both painful and costly. The point prevalence of open venous leg ulcers in the UK is about 3 cases per 10,000 people, and many people experience recurrent episodes of prolonged ulceration. First-line treatment for venous leg ulcers is compression therapy, but a wide range of dressings and topical treatments are also used. This diversity of treatments makes evidence-based decision-making challenging, and a clear and current overview of all the evidence is required. This review is a network meta-analysis (NMA) which assesses the probability of complete ulcer healing associated with alternative dressings and topical agents.
OBJECTIVES
To assess the effects of (1) dressings and (2) topical agents for healing venous leg ulcers in any care setting and to rank treatments in order of effectiveness, with assessment of uncertainty and evidence quality.
SEARCH METHODS
In March 2017 we searched the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid Embase and EBSCO CINAHL Plus. We also scanned reference lists of relevant included studies as well as reviews, meta-analyses, guidelines and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. We updated this search in March 2018; as a result several studies are awaiting classification.
SELECTION CRITERIA
We included published or unpublished randomised controlled trials (RCTs) that enrolled adults with venous leg ulcers and compared the effects of at least one of the following interventions with any other intervention in the treatment of venous leg ulcers: any dressing, or any topical agent applied directly to an open venous leg ulcer and left in situ. We excluded from this review dressings attached to external devices such as negative pressure wound therapies, skin grafts, growth factors and other biological agents, larval therapy and treatments such as laser, heat or ultrasound. Studies were required to report complete wound healing to be eligible.
DATA COLLECTION AND ANALYSIS
Two review authors independently performed study selection, 'Risk of bias' assessment and data extraction. We conducted this NMA using frequentist meta-regression methods for the efficacy outcome; the probability of complete healing. We assumed that treatment effects were similar within dressings classes (e.g. hydrocolloid, foam). We present estimates of effect with their 95% confidence intervals (CIs) for individual treatments focusing on comparisons with widely used dressing classes, and we report ranking probabilities for each intervention (probability of being the best, second best, etc treatment). We assessed the certainty (quality) of the body of evidence using GRADE for each network comparison and for the network as whole.
MAIN RESULTS
We included 78 RCTs (7014 participants) in this review. Of these, 59 studies (5156 participants, 25 different interventions) were included in the NMA; resulting in 40 direct contrasts which informed 300 mixed-treatment contrasts.The evidence for the network as a whole was of low certainty. This judgement was based on the sparsity of the network leading to imprecision and the general high risk of bias in the included studies. Sensitivity analyses also demonstrated instability in key aspects of the network and results are reported for the extended sensitivity analysis. Evidence for individual contrasts was mainly judged to be low or very low certainty.The uncertainty was perpetuated when the results were considered by ranking the treatments in terms of the probability that they were the most effective for ulcer healing, with many treatments having similar, low, probabilities of being the best treatment. The two most highly-ranked treatments both had more than 50% probability of being the best (sucralfate and silver dressings). However, the data for sucralfate was from one small study, which means that this finding should be interpreted with caution. When exploring the data for silver and sucralfate compared with widely-used dressing classes, there was some evidence that silver dressings may increase the probability of venous leg ulcer healing, compared with nonadherent dressings: RR 2.43, 95% CI 1.58 to 3.74 (moderate-certainty evidence in the context of a low-certainty network). For all other combinations of these five interventions it was unclear whether the intervention increased the probability of healing; in each case this was low- or very low-certainty evidence as a consequence of one or more of imprecision, risk of bias and inconsistency.
AUTHORS' CONCLUSIONS
More research is needed to determine whether particular dressings or topical agents improve the probability of healing of venous leg ulcers. However, the NMA is uninformative regarding which interventions might best be included in a large trial, largely because of the low certainty of the whole network and of individual comparisons.The results of this NMA focus exclusively on complete healing; whilst this is of key importance to people living with venous leg ulcers, clinicians may wish to take into account other patient-important outcomes and factors such as patient preference and cost.
Topics: Aged; Aged, 80 and over; Anti-Ulcer Agents; Bandages; Bandages, Hydrocolloid; Female; Humans; Male; Middle Aged; Network Meta-Analysis; Randomized Controlled Trials as Topic; Sensitivity and Specificity; Silver; Sucralfate; Varicose Ulcer; Wound Healing
PubMed: 29906322
DOI: 10.1002/14651858.CD012583.pub2 -
The Cochrane Database of Systematic... Oct 2022Antipsychotic-induced weight gain is an extremely common problem in people with schizophrenia and is associated with increased morbidity and mortality. Adjunctive... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Antipsychotic-induced weight gain is an extremely common problem in people with schizophrenia and is associated with increased morbidity and mortality. Adjunctive pharmacological interventions may be necessary to help manage antipsychotic-induced weight gain. This review splits and updates a previous Cochrane Review that focused on both pharmacological and behavioural approaches to this problem.
OBJECTIVES
To determine the effectiveness of pharmacological interventions for preventing antipsychotic-induced weight gain in people with schizophrenia.
SEARCH METHODS
The Cochrane Schizophrenia Information Specialist searched Cochrane Schizophrenia's Register of Trials on 10 February 2021. There are no language, date, document type, or publication status limitations for inclusion of records in the register.
SELECTION CRITERIA
We included all randomised controlled trials (RCTs) that examined any adjunctive pharmacological intervention for preventing weight gain in people with schizophrenia or schizophrenia-like illnesses who use antipsychotic medications.
DATA COLLECTION AND ANALYSIS
At least two review authors independently extracted data and assessed the quality of included studies. For continuous outcomes, we combined mean differences (MD) in endpoint and change data in the analysis. For dichotomous outcomes, we calculated risk ratios (RR). We assessed risk of bias for included studies and used GRADE to judge certainty of evidence and create summary of findings tables. The primary outcomes for this review were clinically important change in weight, clinically important change in body mass index (BMI), leaving the study early, compliance with treatment, and frequency of nausea. The included studies rarely reported these outcomes, so, post hoc, we added two new outcomes, average endpoint/change in weight and average endpoint/change in BMI.
MAIN RESULTS
Seventeen RCTs, with a total of 1388 participants, met the inclusion criteria for the review. Five studies investigated metformin, three topiramate, three H2 antagonists, three monoamine modulators, and one each investigated monoamine modulators plus betahistine, melatonin and samidorphan. The comparator in all studies was placebo or no treatment (i.e. standard care alone). We synthesised all studies in a quantitative meta-analysis. Most studies inadequately reported their methods of allocation concealment and blinding of participants and personnel. The resulting risk of bias and often small sample sizes limited the overall certainty of the evidence. Only one reboxetine study reported the primary outcome, number of participants with clinically important change in weight. Fewer people in the treatment condition experienced weight gains of more than 5% and more than 7% of their bodyweight than those in the placebo group (> 5% weight gain RR 0.27, 95% confidence interval (CI) 0.11 to 0.65; 1 study, 43 participants; > 7% weight gain RR 0.24, 95% CI 0.07 to 0.83; 1 study, 43 participants; very low-certainty evidence). No studies reported the primary outcomes, 'clinically important change in BMI', or 'compliance with treatment'. However, several studies reported 'average endpoint/change in body weight' or 'average endpoint/change in BMI'. Metformin may be effective in preventing weight gain (MD -4.03 kg, 95% CI -5.78 to -2.28; 4 studies, 131 participants; low-certainty evidence); and BMI increase (MD -1.63 kg/m2, 95% CI -2.96 to -0.29; 5 studies, 227 participants; low-certainty evidence). Other agents that may be slightly effective in preventing weight gain include H2 antagonists such as nizatidine, famotidine and ranitidine (MD -1.32 kg, 95% CI -2.09 to -0.56; 3 studies, 248 participants; low-certainty evidence) and monoamine modulators such as reboxetine and fluoxetine (weight: MD -1.89 kg, 95% CI -3.31 to -0.47; 3 studies, 103 participants; low-certainty evidence; BMI: MD -0.66 kg/m2, 95% CI -1.05 to -0.26; 3 studies, 103 participants; low-certainty evidence). Topiramate did not appear effective in preventing weight gain (MD -4.82 kg, 95% CI -9.99 to 0.35; 3 studies, 168 participants; very low-certainty evidence). For all agents, there was no difference between groups in terms of individuals leaving the study or reports of nausea. However, the results of these outcomes are uncertain given the very low-certainty evidence.
AUTHORS' CONCLUSIONS
There is low-certainty evidence to suggest that metformin may be effective in preventing weight gain. Interpretation of this result and those for other agents, is limited by the small number of studies, small sample size, and short study duration. In future, we need studies that are adequately powered and with longer treatment durations to further evaluate the efficacy and safety of interventions for managing weight gain.
Topics: Antipsychotic Agents; Betahistine; Famotidine; Fluoxetine; Humans; Melatonin; Metformin; Nausea; Nizatidine; Ranitidine; Reboxetine; Schizophrenia; Topiramate; Weight Gain
PubMed: 36190739
DOI: 10.1002/14651858.CD013337.pub2 -
Digestion 2023Vonoprazan, a novel potassium-competitive acid blocker, has a strong acid suppression effect and potent efficacy in acid-associated diseases, including Helicobacter... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
Vonoprazan, a novel potassium-competitive acid blocker, has a strong acid suppression effect and potent efficacy in acid-associated diseases, including Helicobacter pylori eradication. We performed a systematic review and meta-analysis to investigate the efficacy and safety of vonoprazan/amoxicillin dual therapy for H. pylori eradication.
METHODS
We conducted a systematic literature search through PubMed, Web of Science, EMBASE, and the Cochrane Library up to June 2022, to identify randomized controlled trials and cohort studies comparing vonoprazan/amoxicillin dual therapy and triple therapies for H. pylori eradication. Primary outcomes were cure rates and relative efficacy. Secondary outcomes included adverse events, dropout rate, and subgroup analysis.
RESULTS
Five studies with 1,852 patients were included in the analysis. The cure rates of vonoprazan/amoxicillin dual therapy were 85.6% with 95% confidence interval (CI) of 79.7-91.5% and 88.5% (95% CI: 83.2-93.8%) in the intention-to-treat and per-protocol analyses. The efficacy of vonoprazan/amoxicillin dual therapy was not inferior to that of triple therapy with pooled risk ratio (RR) of 1.03 (95% CI: 0.97-1.10) and 1.02 (95% CI: 0.98-1.08) in intention-to-treat and per-protocol analyses; while it was significantly superior to the omeprazole or lansoprazole-based triple therapy (RR = 1.15, 95% CI: 1.05-1.25, p = 0.001). For clarithromycin-resistant strains, vonoprazan/amoxicillin dual therapy showed superiority to vonoprazan-based triple therapy (86.7% vs. 71.4%, RR = 1.20, 95% CI: 1.03-1.39, p = 0.02); however, vonoprazan/amoxicillin dual therapy was significant inferior to vonoprazan-based triple therapy for clarithromycin-sensitive strains (83.0% vs. 92.8%, RR = 0.90, 95% CI: 0.85-0.95, p = 0.0002). The adverse effects of vonoprazan/amoxicillin dual therapy were lower than those of triple therapy (21.2% vs. 26.5%, RR = 0.86, 95% CI: 0.73-1.01, p = 0.06), especially the incidence of diarrhea (p = 0.01).
CONCLUSIONS
The efficacy of vonoprazan/amoxicillin dual therapy is noninferior to vonoprazan-based triple therapy but superior to the omeprazole or lansoprazole-based triple therapy and has less side effects. Patients with clarithromycin-resistant strains are particularly expected to benefit from vonoprazan/amoxicillin dual therapy.
Topics: Humans; Amoxicillin; Clarithromycin; Helicobacter pylori; Anti-Bacterial Agents; Helicobacter Infections; Proton Pump Inhibitors; Drug Therapy, Combination; Pyrroles; Lansoprazole; Omeprazole; Treatment Outcome
PubMed: 37015201
DOI: 10.1159/000529622 -
The Cochrane Database of Systematic... Mar 2023Mechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods.... (Review)
Review
BACKGROUND
Mechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods. Potential advantages of mechanical methods, compared with pharmacological methods may include reduction in side effects that could improve neonatal outcomes. This is an update of a review first published in 2001, last updated in 2012.
OBJECTIVES
To determine the effectiveness and safety of mechanical methods for third trimester (> 24 weeks' gestation) induction of labour in comparison with prostaglandin E2 (PGE2) (vaginal and intracervical), low-dose misoprostol (oral and vaginal), amniotomy or oxytocin.
SEARCH METHODS
For this update, we searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP), and reference lists of retrieved studies (9 January 2018). We updated the search in March 2019 and added the search results to the awaiting classification section of the review.
SELECTION CRITERIA
Clinical trials comparing mechanical methods used for third trimester cervical ripening or labour induction with pharmacological methods. Mechanical methods include: (1) the introduction of a catheter through the cervix into the extra-amniotic space with balloon insufflation; (2) introduction of laminaria tents, or their synthetic equivalent (Dilapan), into the cervical canal; (3) use of a catheter to inject fluid into the extra-amniotic space (EASI). This review includes the following comparisons: (1) specific mechanical methods (balloon catheter, laminaria tents or EASI) compared with prostaglandins (different types, different routes) or with oxytocin; (2) single balloon compared to a double balloon; (3) addition of prostaglandins or oxytocin to mechanical methods compared with prostaglandins or oxytocin alone.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed trials for inclusion and assessed risk of bias. Two review authors independently extracted data and assessed the quality of the evidence using the GRADE approach.
MAIN RESULTS
This review includes a total of 112 trials, with 104 studies contributing data (22,055 women; 21 comparisons). Risk of bias of trials varied. Overall, the evidence was graded from very-low to moderate quality. All evidence was downgraded for lack of blinding and, for many comparisons, the effect estimates were too imprecise to make a valid judgement. Balloon versus vaginal PGE2: there may be little or no difference in vaginal deliveries not achieved within 24 hours (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.82 to 1.26; 7 studies; 1685 women; low-quality evidence) and there probably is little or no difference in caesarean sections (RR 1.00, 95% CI 0.92 to 1.09; 28 studies; 6619 women; moderate-quality evidence) between induction of labour with a balloon catheter and vaginal PGE2. A balloon catheter probably reduces the risk of uterine hyperstimulation with fetal heart rate (FHR) changes (RR 0.35, 95% CI 0.18 to 0.67; 6 studies; 1966 women; moderate-quality evidence), serious neonatal morbidity or perinatal death (RR 0.48, 95% CI 0.25 to 0.93; 8 studies; 2757 women; moderate-quality evidence) and may slightly reduce the risk of aneonatal intensive care unit (NICU) admission (RR 0.82, 95% CI 0.65 to 1.04; 3647 women; 12 studies; low-quality evidence). It is uncertain whether there is a difference in serious maternal morbidity or death (RR 0.20, 95% CI 0.01 to 4.12; 4 studies; 1481 women) or five-minute Apgar score < 7 (RR 0.74, 95% CI 0.49 to 1.14; 4271 women; 14 studies) because the quality of the evidence was found to be very low and low, respectively. Balloon versus low-dose vaginal misoprostol: it is uncertain whether there is a difference in vaginal deliveries not achieved within 24 hours between induction of labour with a balloon catheter and vaginal misoprostol (RR 1.09, 95% CI 0.85 to 1.39; 340 women; 2 studies; low-quality evidence). A balloon catheter probably reduces the risk of uterine hyperstimulation with FHR changes (RR 0.39, 95% CI 0.18 to 0.85; 1322 women; 8 studies; moderate-quality evidence) but may increase the risk of a caesarean section (RR 1.28, 95% CI 1.02 to 1.60; 1756 women; 12 studies; low-quality evidence). It is uncertain whether there is a difference in serious neonatal morbidity or perinatal death (RR 0.58, 95% CI 0.12 to 2.66; 381 women; 3 studies), serious maternal morbidity or death (no events; 4 studies, 464 women), both very low-quality evidence, and five-minute Apgar score < 7 (RR 1.00, 95% CI 0.50 to 1.97; 941 women; 7 studies) and NICU admissions (RR 1.00, 95% CI 0.61 to 1.63; 1302 women; 9 studies) both low-quality evidence. Balloon versus low-dose oral misoprostol: a balloon catheter probably increases the risk of a vaginal delivery not achieved within 24 hours (RR 1.28, 95% CI 1.13 to 1.46; 782 women, 2 studies, and probably slightly increases the risk of a caesarean section (RR 1.17, 95% CI 1.04 to 1.32; 3178 women; 7 studies; both moderate-quality evidence) when compared to oral misoprostol. It is uncertain whether there is a difference in uterine hyperstimulation with FHR changes (RR 0.81, 95% CI 0.48 to 1.38; 2033 women; 2 studies), serious neonatal morbidity or perinatal death (RR 1.11, 95% CI 0.60 to 2.06; 2627 women; 3 studies), both low-quality evidence, serious maternal morbidity or death (RR 0.50, 95% CI 0.05 to 5.52; 2627 women; 3 studies), very low-quality evidence, five-minute Apgar scores < 7 (RR 0.71, 95% CI 0.38 to 1.32; 2693 women; 4 studies) and NICU admissions (RR 0.82, 95% CI 0.58 to 1.17; 2873 women; 5 studies) both low-quality evidence.
AUTHORS' CONCLUSIONS
Low- to moderate-quality evidence shows mechanical induction with a balloon is probably as effective as induction of labour with vaginal PGE2. However, a balloon seems to have a more favourable safety profile. More research on this comparison does not seem warranted. Moderate-quality evidence shows a balloon catheter may be slightly less effective as oral misoprostol, but it remains unclear if there is a difference in safety outcomes for the neonate. When compared to low-dose vaginal misoprostol, low-quality evidence shows a balloon may be less effective, but probably has a better safety profile. Future research could be focused more on safety aspects for the neonate and maternal satisfaction.
Topics: Female; Humans; Infant, Newborn; Pregnancy; Cesarean Section; Dinoprostone; Labor, Induced; Misoprostol; Oxytocin; Perinatal Death
PubMed: 36996264
DOI: 10.1002/14651858.CD001233.pub4 -
The Cochrane Database of Systematic... Apr 2018Postpartum haemorrhage (PPH) is the leading cause of maternal mortality worldwide. Prophylactic uterotonic drugs can prevent PPH, and are routinely recommended. There... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Postpartum haemorrhage (PPH) is the leading cause of maternal mortality worldwide. Prophylactic uterotonic drugs can prevent PPH, and are routinely recommended. There are several uterotonic drugs for preventing PPH but it is still debatable which drug is best.
OBJECTIVES
To identify the most effective uterotonic drug(s) to prevent PPH, and generate a ranking according to their effectiveness and side-effect profile.
SEARCH METHODS
We searched Cochrane Pregnancy and Childbirth's Trials Register (1 June 2015), ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) for unpublished trial reports (30 June 2015) and reference lists of retrieved studies.
SELECTION CRITERIA
All randomised controlled comparisons or cluster trials of effectiveness or side-effects of uterotonic drugs for preventing PPH.Quasi-randomised trials and cross-over trials are not eligible for inclusion in this review.
DATA COLLECTION AND ANALYSIS
At least three review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. We estimated the relative effects and rankings for preventing PPH ≥ 500 mL and PPH ≥ 1000 mL as primary outcomes. We performed pairwise meta-analyses and network meta-analysis to determine the relative effects and rankings of all available drugs. We stratified our primary outcomes according to mode of birth, prior risk of PPH, healthcare setting, dosage, regimen and route of drug administration, to detect subgroup effects.The absolute risks in the oxytocin are based on meta-analyses of proportions from the studies included in this review and the risks in the intervention groups were based on the assumed risk in the oxytocin group and the relative effects of the interventions.
MAIN RESULTS
This network meta-analysis included 140 randomised trials with data from 88,947 women. There are two large ongoing studies. The trials were mostly carried out in hospital settings and recruited women who were predominantly more than 37 weeks of gestation having a vaginal birth. The majority of trials were assessed to have uncertain risk of bias due to poor reporting of study design. This primarily impacted on our confidence in comparisons involving carbetocin trials more than other uterotonics.The three most effective drugs for prevention of PPH ≥ 500 mL were ergometrine plus oxytocin combination, carbetocin, and misoprostol plus oxytocin combination. These three options were more effective at preventing PPH ≥ 500 mL compared with oxytocin, the drug currently recommended by the WHO (ergometrine plus oxytocin risk ratio (RR) 0.69 (95% confidence interval (CI) 0.57 to 0.83), moderate-quality evidence; carbetocin RR 0.72 (95% CI 0.52 to 1.00), very low-quality evidence; misoprostol plus oxytocin RR 0.73 (95% CI 0.60 to 0.90), moderate-quality evidence). Based on these results, about 10.5% women given oxytocin would experience a PPH of ≥ 500 mL compared with 7.2% given ergometrine plus oxytocin combination, 7.6% given carbetocin, and 7.7% given misoprostol plus oxytocin. Oxytocin was ranked fourth with close to 0% cumulative probability of being ranked in the top three for PPH ≥ 500 mL.The outcomes and rankings for the outcome of PPH ≥ 1000 mL were similar to those of PPH ≥ 500 mL. with the evidence for ergometrine plus oxytocin combination being more effective than oxytocin (RR 0.77 (95% CI 0.61 to 0.95), high-quality evidence) being more certain than that for carbetocin (RR 0.70 (95% CI 0.38 to 1.28), low-quality evidence), or misoprostol plus oxytocin combination (RR 0.90 (95% CI 0.72 to 1.14), moderate-quality evidence)There were no meaningful differences between all drugs for maternal deaths or severe morbidity as these outcomes were so rare in the included randomised trials.Two combination regimens had the poorest rankings for side-effects. Specifically, the ergometrine plus oxytocin combination had the higher risk for vomiting (RR 3.10 (95% CI 2.11 to 4.56), high-quality evidence; 1.9% versus 0.6%) and hypertension [RR 1.77 (95% CI 0.55 to 5.66), low-quality evidence; 1.2% versus 0.7%), while the misoprostol plus oxytocin combination had the higher risk for fever (RR 3.18 (95% CI 2.22 to 4.55), moderate-quality evidence; 11.4% versus 3.6%) when compared with oxytocin. Carbetocin had similar risk for side-effects compared with oxytocin although the quality evidence was very low for vomiting and for fever, and was low for hypertension.
AUTHORS' CONCLUSIONS
Ergometrine plus oxytocin combination, carbetocin, and misoprostol plus oxytocin combination were more effective for preventing PPH ≥ 500 mL than the current standard oxytocin. Ergometrine plus oxytocin combination was more effective for preventing PPH ≥ 1000 mL than oxytocin. Misoprostol plus oxytocin combination evidence is less consistent and may relate to different routes and doses of misoprostol used in the studies. Carbetocin had the most favourable side-effect profile amongst the top three options; however, most carbetocin trials were small and at high risk of bias.Amongst the 11 ongoing studies listed in this review there are two key studies that will inform a future update of this review. The first is a WHO-led multi-centre study comparing the effectiveness of a room temperature stable carbetocin versus oxytocin (administered intramuscularly) for preventing PPH in women having a vaginal birth. The trial includes around 30,000 women from 10 countries. The other is a UK-based trial recruiting more than 6000 women to a three-arm trial comparing carbetocin, oxytocin and ergometrine plus oxytocin combination. Both trials are expected to report in 2018.Consultation with our consumer group demonstrated the need for more research into PPH outcomes identified as priorities for women and their families, such as women's views regarding the drugs used, clinical signs of excessive blood loss, neonatal unit admissions and breastfeeding at discharge. To date, trials have rarely investigated these outcomes. Consumers also considered the side-effects of uterotonic drugs to be important but these were often not reported. A forthcoming set of core outcomes relating to PPH will identify outcomes to prioritise in trial reporting and will inform futures updates of this review. We urge all trialists to consider measuring these outcomes for each drug in all future randomised trials. Lastly, future evidence synthesis research could compare the effects of different dosages and routes of administration for the most effective drugs.
Topics: Drug Therapy, Combination; Ergonovine; Female; Fever; Humans; Hypertension; Misoprostol; Network Meta-Analysis; Oxytocics; Oxytocin; Postpartum Hemorrhage; Vomiting
PubMed: 29693726
DOI: 10.1002/14651858.CD011689.pub2 -
The Cochrane Database of Systematic... Jan 2020Nearsightedness (myopia) causes blurry vision when one is looking at distant objects. Interventions to slow the progression of myopia in children include multifocal... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Nearsightedness (myopia) causes blurry vision when one is looking at distant objects. Interventions to slow the progression of myopia in children include multifocal spectacles, contact lenses, and pharmaceutical agents.
OBJECTIVES
To assess the effects of interventions, including spectacles, contact lenses, and pharmaceutical agents in slowing myopia progression in children.
SEARCH METHODS
We searched CENTRAL; Ovid MEDLINE; Embase.com; PubMed; the LILACS Database; and two trial registrations up to February 2018. A top up search was done in February 2019.
SELECTION CRITERIA
We included randomized controlled trials (RCTs). We excluded studies when most participants were older than 18 years at baseline. We also excluded studies when participants had less than -0.25 diopters (D) spherical equivalent myopia.
DATA COLLECTION AND ANALYSIS
We followed standard Cochrane methods.
MAIN RESULTS
We included 41 studies (6772 participants). Twenty-one studies contributed data to at least one meta-analysis. Interventions included spectacles, contact lenses, pharmaceutical agents, and combination treatments. Most studies were conducted in Asia or in the United States. Except one, all studies included children 18 years or younger. Many studies were at high risk of performance and attrition bias. Spectacle lenses: undercorrection of myopia increased myopia progression slightly in two studies; children whose vision was undercorrected progressed on average -0.15 D (95% confidence interval [CI] -0.29 to 0.00; n = 142; low-certainty evidence) more than those wearing fully corrected single vision lenses (SVLs). In one study, axial length increased 0.05 mm (95% CI -0.01 to 0.11) more in the undercorrected group than in the fully corrected group (n = 94; low-certainty evidence). Multifocal lenses (bifocal spectacles or progressive addition lenses) yielded small effect in slowing myopia progression; children wearing multifocal lenses progressed on average 0.14 D (95% CI 0.08 to 0.21; n = 1463; moderate-certainty evidence) less than children wearing SVLs. In four studies, axial elongation was less for multifocal lens wearers than for SVL wearers (-0.06 mm, 95% CI -0.09 to -0.04; n = 896; moderate-certainty evidence). Three studies evaluating different peripheral plus spectacle lenses versus SVLs reported inconsistent results for refractive error and axial length outcomes (n = 597; low-certainty evidence). Contact lenses: there may be little or no difference between vision of children wearing bifocal soft contact lenses (SCLs) and children wearing single vision SCLs (mean difference (MD) 0.20D, 95% CI -0.06 to 0.47; n = 300; low-certainty evidence). Axial elongation was less for bifocal SCL wearers than for single vision SCL wearers (MD -0.11 mm, 95% CI -0.14 to -0.08; n = 300; low-certainty evidence). Two studies investigating rigid gas permeable contact lenses (RGPCLs) showed inconsistent results in myopia progression; these two studies also found no evidence of difference in axial elongation (MD 0.02mm, 95% CI -0.05 to 0.10; n = 415; very low-certainty evidence). Orthokeratology contact lenses were more effective than SVLs in slowing axial elongation (MD -0.28 mm, 95% CI -0.38 to -0.19; n = 106; moderate-certainty evidence). Two studies comparing spherical aberration SCLs with single vision SCLs reported no difference in myopia progression nor in axial length (n = 209; low-certainty evidence). Pharmaceutical agents: at one year, children receiving atropine eye drops (3 studies; n = 629), pirenzepine gel (2 studies; n = 326), or cyclopentolate eye drops (1 study; n = 64) showed significantly less myopic progression compared with children receiving placebo: MD 1.00 D (95% CI 0.93 to 1.07), 0.31 D (95% CI 0.17 to 0.44), and 0.34 (95% CI 0.08 to 0.60), respectively (moderate-certainty evidence). Axial elongation was less for children treated with atropine (MD -0.35 mm, 95% CI -0.38 to -0.31; n = 502) and pirenzepine (MD -0.13 mm, 95% CI -0.14 to -0.12; n = 326) than for those treated with placebo (moderate-certainty evidence) in two studies. Another study showed favorable results for three different doses of atropine eye drops compared with tropicamide eye drops (MD 0.78 D, 95% CI 0.49 to 1.07 for 0.1% atropine; MD 0.81 D, 95% CI 0.57 to 1.05 for 0.25% atropine; and MD 1.01 D, 95% CI 0.74 to 1.28 for 0.5% atropine; n = 196; low-certainty evidence) but did not report axial length. Systemic 7-methylxanthine had little to no effect on myopic progression (MD 0.07 D, 95% CI -0.09 to 0.24) nor on axial elongation (MD -0.03 mm, 95% CI -0.10 to 0.03) compared with placebo in one study (n = 77; moderate-certainty evidence). One study did not find slowed myopia progression when comparing timolol eye drops with no drops (MD -0.05 D, 95% CI -0.21 to 0.11; n = 95; low-certainty evidence). Combinations of interventions: two studies found that children treated with atropine plus multifocal spectacles progressed 0.78 D (95% CI 0.54 to 1.02) less than children treated with placebo plus SVLs (n = 191; moderate-certainty evidence). One study reported -0.37 mm (95% CI -0.47 to -0.27) axial elongation for atropine and multifocal spectacles when compared with placebo plus SVLs (n = 127; moderate-certainty evidence). Compared with children treated with cyclopentolate plus SVLs, those treated with atropine plus multifocal spectacles progressed 0.36 D less (95% CI 0.11 to 0.61; n = 64; moderate-certainty evidence). Bifocal spectacles showed small or negligible effect compared with SVLs plus timolol drops in one study (MD 0.19 D, 95% CI 0.06 to 0.32; n = 97; moderate-certainty evidence). One study comparing tropicamide plus bifocal spectacles versus SVLs reported no statistically significant differences between groups without quantitative results. No serious adverse events were reported across all interventions. Participants receiving antimuscarinic topical medications were more likely to experience accommodation difficulties (Risk Ratio [RR] 9.05, 95% CI 4.09 to 20.01) and papillae and follicles (RR 3.22, 95% CI 2.11 to 4.90) than participants receiving placebo (n=387; moderate-certainty evidence).
AUTHORS' CONCLUSIONS
Antimuscarinic topical medication is effective in slowing myopia progression in children. Multifocal lenses, either spectacles or contact lenses, may also confer a small benefit. Orthokeratology contact lenses, although not intended to modify refractive error, were more effective than SVLs in slowing axial elongation. We found only low or very low-certainty evidence to support RGPCLs and sperical aberration SCLs.
Topics: Atropine; Child; Contact Lenses; Cyclopentolate; Humans; Muscarinic Antagonists; Myopia, Degenerative; Ophthalmic Solutions; Pirenzepine; Randomized Controlled Trials as Topic
PubMed: 31930781
DOI: 10.1002/14651858.CD004916.pub4 -
The Cochrane Database of Systematic... Jun 2021Miscarriage, defined as the spontaneous loss of a pregnancy before 24 weeks' gestation, is common with approximately 25% of women experiencing a miscarriage in their... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Miscarriage, defined as the spontaneous loss of a pregnancy before 24 weeks' gestation, is common with approximately 25% of women experiencing a miscarriage in their lifetime. An estimated 15% of pregnancies end in miscarriage. Miscarriage can lead to serious morbidity, including haemorrhage, infection, and even death, particularly in settings without adequate healthcare provision. Early miscarriages occur during the first 14 weeks of pregnancy, and can be managed expectantly, medically or surgically. However, there is uncertainty about the relative effectiveness and risks of each option.
OBJECTIVES
To estimate the relative effectiveness and safety profiles for the different management methods for early miscarriage, and to provide rankings of the available methods according to their effectiveness, safety, and side-effect profile using a network meta-analysis.
SEARCH METHODS
We searched the Cochrane Pregnancy and Childbirth's Trials Register (9 February 2021), ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform (ICTRP) (12 February 2021), and reference lists of retrieved studies.
SELECTION CRITERIA
We included all randomised controlled trials assessing the effectiveness or safety of methods for miscarriage management. Early miscarriage was defined as less than or equal to 14 weeks of gestation, and included missed and incomplete miscarriage. Management of late miscarriages after 14 weeks of gestation (often referred to as intrauterine fetal deaths) was not eligible for inclusion in the review. Cluster- and quasi-randomised trials were eligible for inclusion. Randomised trials published only as abstracts were eligible if sufficient information could be retrieved. We excluded non-randomised trials.
DATA COLLECTION AND ANALYSIS
At least three review authors independently assessed the trials for inclusion and risk of bias, extracted data and checked them for accuracy. We estimated the relative effects and rankings for the primary outcomes of complete miscarriage and composite outcome of death or serious complications. The certainty of evidence was assessed using GRADE. Relative effects for the primary outcomes are reported subgrouped by the type of miscarriage (incomplete and missed miscarriage). We also performed pairwise meta-analyses and network meta-analysis to determine the relative effects and rankings of all available methods.
MAIN RESULTS
Our network meta-analysis included 78 randomised trials involving 17,795 women from 37 countries. Most trials (71/78) were conducted in hospital settings and included women with missed or incomplete miscarriage. Across 158 trial arms, the following methods were used: 51 trial arms (33%) used misoprostol; 50 (32%) used suction aspiration; 26 (16%) used expectant management or placebo; 17 (11%) used dilatation and curettage; 11 (6%) used mifepristone plus misoprostol; and three (2%) used suction aspiration plus cervical preparation. Of these 78 studies, 71 (90%) contributed data in a usable form for meta-analysis. Complete miscarriage Based on the relative effects from the network meta-analysis of 59 trials (12,591 women), we found that five methods may be more effective than expectant management or placebo for achieving a complete miscarriage: · suction aspiration after cervical preparation (risk ratio (RR) 2.12, 95% confidence interval (CI) 1.41 to 3.20, low-certainty evidence), · dilatation and curettage (RR 1.49, 95% CI 1.26 to 1.75, low-certainty evidence), · suction aspiration (RR 1.44, 95% CI 1.29 to 1.62, low-certainty evidence), · mifepristone plus misoprostol (RR 1.42, 95% CI 1.22 to 1.66, moderate-certainty evidence), · misoprostol (RR 1.30, 95% CI 1.16 to 1.46, low-certainty evidence). The highest ranked surgical method was suction aspiration after cervical preparation. The highest ranked non-surgical treatment was mifepristone plus misoprostol. All surgical methods were ranked higher than medical methods, which in turn ranked above expectant management or placebo. Composite outcome of death and serious complications Based on the relative effects from the network meta-analysis of 35 trials (8161 women), we found that four methods with available data were compatible with a wide range of treatment effects compared with expectant management or placebo: · dilatation and curettage (RR 0.43, 95% CI 0.17 to 1.06, low-certainty evidence), · suction aspiration (RR 0.55, 95% CI 0.23 to 1.32, low-certainty evidence), · misoprostol (RR 0.50, 95% CI 0.22 to 1.15, low-certainty evidence), · mifepristone plus misoprostol (RR 0.76, 95% CI 0.31 to 1.84, low-certainty evidence). Importantly, no deaths were reported in these studies, thus this composite outcome was entirely composed of serious complications, including blood transfusions, uterine perforations, hysterectomies, and intensive care unit admissions. Expectant management and placebo ranked the lowest when compared with alternative treatment interventions. Subgroup analyses by type of miscarriage (missed or incomplete) agreed with the overall analysis in that surgical methods were the most effective treatment, followed by medical methods and then expectant management or placebo, but there are possible subgroup differences in the effectiveness of the available methods. AUTHORS' CONCLUSIONS: Based on relative effects from the network meta-analysis, all surgical and medical methods for managing a miscarriage may be more effective than expectant management or placebo. Surgical methods were ranked highest for managing a miscarriage, followed by medical methods, which in turn ranked above expectant management or placebo. Expectant management or placebo had the highest chance of serious complications, including the need for unplanned or emergency surgery. A subgroup analysis showed that surgical and medical methods may be more beneficial in women with missed miscarriage compared to women with incomplete miscarriage. Since type of miscarriage (missed and incomplete) appears to be a source of inconsistency and heterogeneity within these data, we acknowledge that the main network meta-analysis may be unreliable. However, we plan to explore this further in future updates and consider the primary analysis as separate networks for missed and incomplete miscarriage.
Topics: Abortion, Incomplete; Abortion, Missed; Abortion, Spontaneous; Drug Therapy, Combination; Female; Humans; Mifepristone; Misoprostol; Network Meta-Analysis; Oxytocics; Placebos; Pregnancy; Pregnancy Trimester, First; Randomized Controlled Trials as Topic; Suction; Vacuum Curettage; Watchful Waiting
PubMed: 34061352
DOI: 10.1002/14651858.CD012602.pub2