-
Dental Materials Journal May 2022The cytocompatibility and osteoconductivity of the Zr-14Nb-5Ta-1Mo alloy were investigated using a mouse osteoblastic cell line (MC3T3-E1) to promote the application of...
The cytocompatibility and osteoconductivity of the Zr-14Nb-5Ta-1Mo alloy were investigated using a mouse osteoblastic cell line (MC3T3-E1) to promote the application of this newly developed alloy in dental/medical treatment. The initial cell-attached morphology was visualized by fluorescent staining, and cells cultured on the Zr alloy showed similar cell adhesion behavior to cells cultured on titanium (Ti). In our 5-day proliferation investigation, similar cell numbers were obtained with both Zr alloy and Ti. These results indicate that the cytocompatibility of Zr alloy is similar to that of Ti. In addition, the similar results in the evaluation of alkaline phosphatase (ALP) activity and staining of deposited calcium using alizarin red S with both Zr alloy and Ti indicated that the osteoconductivity of the Zr alloy is similar to that of Ti. Our results prove the good cytocompatibility and osteoconductivity of the Zr-14Nb-5Ta-1Mo alloy, enabling its promotion for use in dental/medical applications.
Topics: Alloys; Cell Adhesion; Osteoblasts; Titanium; Zirconium
PubMed: 35135939
DOI: 10.4012/dmj.2021-169 -
Scientific Reports Feb 2023The performance of current biomedical titanium alloys is limited by inflammatory and severe inflammatory conditions after implantation. In this study, a novel...
The performance of current biomedical titanium alloys is limited by inflammatory and severe inflammatory conditions after implantation. In this study, a novel Ti-Nb-Zr-Si (TNZS) alloy was developed and compared with commercially pure titanium, and Ti-6Al-4V alloy. Electrochemical parameters of specimens were monitored during 1 h and 12 h immersion in phosphate buffered saline (PBS) as a normal, PBS/hydrogen peroxide (HO) as an inflammatory, and PBS/HO/albumin/lactate as a severe inflammatory media. The results showed an effect of the HO in inflammatory condition and the synergistic behavior of HO, albumin, and lactate in severe inflammatory condition towards decreasing the corrosion resistance of titanium biomaterials. Electrochemical tests revealed a superior corrosion resistance of the TNZS in all conditions due to the presence of silicide phases. The developed TNZS was tested for subsequent cell culture investigation to understand its biocompatibility nature. It exhibited favorable cell-materials interactions in vitro compared with Ti-6Al-4V. The results suggest that TNZS alloy might be a competitive biomaterial for orthopedic applications.
Topics: Titanium; Niobium; Hydrogen Peroxide; Biocompatible Materials; Alloys; Albumins; Corrosion; Lactic Acid; Materials Testing; Surface Properties
PubMed: 36759646
DOI: 10.1038/s41598-023-29553-5 -
Journal of the Mechanical Behavior of... Sep 2022The corrosion rate of Mg alloys is currently too high for viable resorbable implant applications. One possible solution is to coat the alloy with a hydroxyapatite (HA)...
The corrosion rate of Mg alloys is currently too high for viable resorbable implant applications. One possible solution is to coat the alloy with a hydroxyapatite (HA) layer to slow the corrosion and promote bone growth. As such coatings can be under severe stresses during implant insertion, we present a nano-mechanical and nano-tribological investigation of RF-sputtered HA films on AZ31 Mg alloy substrates. EDX and XRD analysis indicate that as-deposited coatings are amorphous and Ca-deficient whereas rapid thermal annealing results in c-axis orientation and near-stoichiometric composition. Analysis of the nanoindentation data using a thin film model shows that annealing increases the coating's intrinsic hardness (H) and strain at break (H/E) values, from 2.7 GPa to 9.4 GPa and from 0.043 to 0.079, respectively. In addition, despite being rougher, the annealed samples display better wear resistance; a sign that the rapid thermal annealing does not compromise their interfacial strength and that these systems have potential for resorbable bone implant applications.
Topics: Alloys; Coated Materials, Biocompatible; Corrosion; Durapatite; Magnesium; Materials Testing; Surface Properties
PubMed: 35717775
DOI: 10.1016/j.jmbbm.2022.105306 -
BioMed Research International 2023Biodegradable iron alloy implants have become one of the most ideal possible candidates because of their biocompatibility and comprehensive mechanical properties. Iron...
Biodegradable iron alloy implants have become one of the most ideal possible candidates because of their biocompatibility and comprehensive mechanical properties. Iron alloy's impact on chondrocytes is still unknown, though. This investigation looked at the biocompatibility and degradation of the Fe30Mn0.6N alloy as well as how it affected bone formation and chondrocyte autophagy. In vivo implantation of Fe30Mn0.6N and Ti6Al4V rods into rabbit femoral cartilage and femoral shaft was carried out to evaluate the degradation of the alloy and the cartilage and bone response at different intervals. After 8 weeks of implantation, the cross-sectional area of the Fe30Mn0.6N alloys lowered by 50.79 ± 9.59%. More Ca and P element deposition was found on the surface Fe30Mn0.6N rods by using energy dispersive spectroscopy (EDS) and scanning electron microscopy ( < 0.05). After 2, 4, and 8 weeks of implantation, no evident inflammatory infiltration was seen in peri-implant cartilage and bone tissue of Fe30Mn0.6N and Ti6Al4V alloys. Also, implantation of Fe30Mn0.6N alloy promoted autophagy in cartilage by detecting expression of LC3-II compared with Ti6Al4V after implantation ( < 0.05). Fe30Mn0.6N alloy also stimulated early osteogenesis at the peri-implant interface compared with Ti6Al4V after implantation ( < 0.05). In the in vitro test, we found that low concentrations of Fe30Mn0.6N extracts had no influence on cell viability. 15% and 30% extracts of Fe30Mn0.6N could upregulate autophagy compared to the control group by detecting beclin-1, LC3, Atg3, and P62 on the basis of WB and IHC ( < 0.05). Also, the PI3K-AKT-mTOR signaling pathway mediated in the upregulation of autophagy of chondrocytes resulting in exposure to extract of Fe30Mn0.6N alloy. It is concluded that Fe30Mn0.6N showed degradability and biocompatibility in vivo and upregulated autophagy activity in chondrocytes.
Topics: Animals; Rabbits; Osteogenesis; Phosphatidylinositol 3-Kinases; Femur; Alloys; Absorbable Implants; Cartilage
PubMed: 36714031
DOI: 10.1155/2023/3626776 -
Annals of Work Exposures and Health Jul 2020Nickel (Ni) and cobalt (Co) release from chromium-alloy powders (different stainless steels and a nickel-based Inconel alloy) compared with Ni and Co metal powders was...
Nickel (Ni) and cobalt (Co) release from chromium-alloy powders (different stainless steels and a nickel-based Inconel alloy) compared with Ni and Co metal powders was investigated at simulated human exposure scenarios (ingestion, skin contact, and inhalation) between 2 and 168 h. All investigated powders consisted of particles sized within the respirable range. The powder particles and their surface reactivity were studied by means of nitrogen adsorption and electrochemical, spectroscopic (X-ray photoelectron spectroscopy and atomic absorption spectroscopy), light scattering, and microscopic techniques. The release of both Ni and Co was highest in the acidic and complexing fluids simulating the gastric environment and an inhalation scenario of small powders (artificial lysosomal fluid). Relatively high corrosion resistance and lower levels of released Ni and Co were observed in all fluids for all alloy powders compared with the corresponding pure metals. The extent of released metals was low for powders with a passive surface oxide. This study strongly emphasizes the importance of considering alloying effects in toxicological classification and/or regulation of Ni and Co in alloys and metals.
Topics: Alloys; Cobalt; Humans; Nickel; Occupational Exposure; Powders; Surface Properties
PubMed: 32320011
DOI: 10.1093/annweh/wxaa042 -
BioMed Research International 2023Considering the unique properties of magnesium and its alloy, it has a vast demand in biomedical applications, particularly the implant material in tissue engineering...
Considering the unique properties of magnesium and its alloy, it has a vast demand in biomedical applications, particularly the implant material in tissue engineering due to its biodegradability. But the fixing spares must hold such implants till the end of the biodegradation of implant material. The composite technology will offer the added benefits of altering the material properties to match the requirements of the desired applications. Hence, this experimental investigation is aimed at developing a composite material for manufacturing fixing spares like a screw for implants in biomedical applications. The matrix of AZ63 magnesium alloy is reinforced with nanoparticles of zirconium (Zr) and titanium (Ti) through the stir casting-type synthesis method. The samples were prepared with equal contributions of zirconium (Zr) and titanium (Ti) nanoparticles in the total reinforcement percentage (3%, 6%, 9%, and 12%). The corrosive and tribological studies were done. In the corrosive study, the process parameters like NaCl concentration, pH value, and exposure time were varied at three levels. In the wear study, the applied Load, speed of sliding, and the distance of the slide were considered at four levels. Taguchi analysis was employed in this investigation to optimize the reinforcement and independent factors to minimize the wear and corrosive losses. The minimum wear rate was achieved in the 12% reinforced sample with the input factor levels of 60 N of load on the pin, 1 m/s of disc speed at a sliding distance was 1500 m, and the 12% reinforce samples also recorded a minimum corrosive rate of 0.0076 mm/year at the operating environment of 5% NaCl-concentrated solution with the pH value of 9 for 24 hrs of exposure. The prediction model was developed based on the experimental results.
Topics: Titanium; Zirconium; Caustics; Magnesium; Sodium Chloride; Dental Materials; Alloys
PubMed: 37187465
DOI: 10.1155/2023/6297372 -
Advanced Science (Weinheim,... Apr 2024Zinc (Zn)-dysprosium (Dy) binary alloys are promising biodegradable bone fracture fixation implants owing to their attractive biodegradability and mechanical properties....
Zinc (Zn)-dysprosium (Dy) binary alloys are promising biodegradable bone fracture fixation implants owing to their attractive biodegradability and mechanical properties. However, their clinical application is a challenge for bone fracture healing, due to the lack of Zn-Dy alloys with tailored proper bio-mechanical and osteointegration properties for bone regeneration. A Zn-5Dy alloy with high strength and ductility and a degradation rate aligned with the bone remodeling cycle is developed. Here, mechanical stability is further confirmed, proving that Zn-5Dy alloy can resist aging in the degradation process, thus meeting the mechanical requirements of fracture fixation. In vitro cellular experiments reveal that the Zn-5Dy alloy enhances osteogenesis and angiogenesis by elevating SIRT4-mediated mitochondrial function. In vivo Micro-CT, SEM-EDS, and immunohistochemistry analyses further indicate good biosafety, suitable biodegradation rate, and great osteointegration of Zn-5Dy alloy during bone healing, which also depends on the upregulation of SIRT4-mediated mitochondrial events. Overall, the study is the first to report a Zn-5Dy alloy that exerts remarkable osteointegration properties and has a strong potential to promote bone healing. Furthermore, the results highlight the importance of mitochondrial modulation and shall guide the future development of mitochondria-targeting materials in enhancing bone fracture healing.
Topics: Absorbable Implants; Alloys; Materials Testing; Mitochondria; Zinc; Dysprosium; Osteogenesis; Sirtuins; Humans; Fractures, Bone
PubMed: 38243646
DOI: 10.1002/advs.202307812 -
International Journal of Molecular... Dec 2013The introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of... (Review)
Review
The introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of coronary artery disease. However, this medical device can induce hypersensitive reaction that interferes with the endothelialization and healing process resulting in late persistent or acquired malapposition of the permanent metallic implant. Delayed endotheliaization and malapposition may lead to late and very late stent thrombosis. Bioresorbable scaffolds (BRS) have been introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Magnesium is an essential mineral needed for a variety of physiological functions in the human body and its bioresorbable alloy has the strength-to-weight ratio comparable with that of strong aluminum alloys and alloy steels. The aim of this review is to present the new developments in Magnesium BRS technology, to describe its clinical application and to discuss the future prospects of this innovative therapy.
Topics: Alloys; Antibiotics, Antineoplastic; Coronary Artery Disease; Drug-Eluting Stents; Humans; Magnesium; Paclitaxel; Sirolimus
PubMed: 24351829
DOI: 10.3390/ijms141224492 -
Journal of Biomedical Materials... Aug 2020The purpose of the present study was to evaluate the mechanical strength and the absorption rate of WE43 material and to develop an absorbable metallic plate and screw...
The purpose of the present study was to evaluate the mechanical strength and the absorption rate of WE43 material and to develop an absorbable metallic plate and screw for craniofacial application. The extruded WE43 plate and screw were evaluated using a LeFort I osteotomy canine model of 10 beagle dogs. Animals were divided into two groups: five dogs in the experimental group and five dogs in the control group. μCT was acquired at 4, 12, and 24 weeks. At 24 weeks after the operation, all animals were sacrificed, and histologic evaluation was performed. Swelling and gas formation were observed in three dogs in the experimental groups at 8 weeks. From 12 weeks, infraorbital fistula and inflammation were observed in three dogs in the experimental group, which gradually decreased and disappeared at 24 weeks. Other two dogs showed less gas formation at 12 weeks. The plates were completely absorbed, and gas formation was not observed at 24 weeks in these two dogs. New bone was well formed around the plates and screws in both groups. Histologic examination showed no specific differences between two groups. The mechanical strength of extruded WE43 was sufficient for mid-facial application. Plates and screws made with appropriately treated WE43 have the potential to be useful clinically.
Topics: Absorbable Implants; Alloys; Animals; Bone Plates; Bone Screws; Corrosion; Craniofacial Abnormalities; Dogs; Fracture Fixation, Internal; Magnesium Compounds; Mechanical Phenomena; Swine; Swine, Miniature; X-Ray Microtomography
PubMed: 32048809
DOI: 10.1002/jbm.b.34582 -
International Journal of Molecular... 2011This paper reviews the influence of alloying elements Mo, Nb, Ta and Ni on glass formation and corrosion resistance of Cu-based bulk metallic glasses (BMGs). In order to... (Review)
Review
This paper reviews the influence of alloying elements Mo, Nb, Ta and Ni on glass formation and corrosion resistance of Cu-based bulk metallic glasses (BMGs). In order to obtain basic knowledge for application to the industry, corrosion resistance of the Cu-Hf-Ti-(Mo, Nb, Ta, Ni) and Cu-Zr-Ag-Al-(Nb) bulk glassy alloy systems in various solutions are reported in this work. Moreover, X-ray photoelectron spectroscopy (XPS) analysis is performed to clarify the surface-related chemical characteristics of the alloy before and after immersion in the solutions; this has lead to a better understanding of the correlation between the surface composition and the corrosion resistance.
Topics: Alloys; Copper; Corrosion; Glass; Metals; Surface Properties
PubMed: 21731441
DOI: 10.3390/ijms12042275