Transplant International : Official... 2023Peak spirometry after single lung transplantation (SLTx) for interstitial lung disease (ILD) is lower than after double lung transplantation (DLTx), however the...
Peak spirometry after single lung transplantation (SLTx) for interstitial lung disease (ILD) is lower than after double lung transplantation (DLTx), however the pathophysiologic mechanisms are unclear. We aim to assess respiratory mechanics in SLTx and DLTx for ILD using oscillometry. Spirometry and oscillometry (tremoflo C-100) were performed in stable SLTx and DLTx recipients in a multi-center study. Resistance (R, R) and reactance (X) were compared between LTx recipient groups, matched by age and gender. A model of respiratory impedance using ILD and DLTx data was performed. In total, 45 stable LTx recipients were recruited (SLTx = 23, DLTx = 22; males: 87.0% vs. 77.3%; median age 63.0 vs. 63.0 years). Spirometry was significantly lower after SLTx compared with DLTx: %-predicted mean (SD) FEV [70.0 (14.5) vs. 93.5 (26.0)%]; FVC [70.5 (16.8) vs. 90.7 (12.8)%], . R and R were similar between groups ( and , respectively) yet X was significantly worse after SLTx: median (IQR) X [-1.88 (-2.89 to -1.39) vs. -1.22 (-1.87 to -0.86)] cmHO.s/L], . R and X measurements from the model were congruent with measurements in SLTx recipients. The similarities in resistance, yet differences in spirometry and reactance between both transplant groups suggest the important contribution of elastic properties to the pathophysiology. Oscillometry may provide further insight into the physiological changes occurring post-LTx.
Topics: Male; Humans; Middle Aged; Oscillometry; Forced Expiratory Volume; Australia; Lung; Lung Diseases, Interstitial; Allografts
PubMed: 38116170
DOI: 10.3389/ti.2023.11758 -
Medicine Mar 2016Pulse wave velocity (PWV) and augmentation index (AI) are independent predictors of cardiovascular health. However, the comparability of multiple oscillometric... (Comparative Study)
Comparative Study Observational Study
Pulse wave velocity (PWV) and augmentation index (AI) are independent predictors of cardiovascular health. However, the comparability of multiple oscillometric modalities currently available for their assessment was not studied in detail. In the present study, we aimed to evaluate the relationship between indices of arterial stiffness assessed by diastolic and suprasystolic oscillometry.In total, 56 volunteers from the general population (23 males; median age 70 years [interquartile range: 65-72 years]) were recruited into observational feasibility study to evaluate the carotid-femoral/aortic PWV (cf/aoPWV), brachial-ankle PWV (baPWV), and AI assessed by 2 devices: Vicorder (VI) applying diastolic, right-sided oscillometry for the determination of all 3 indices, and Vascular explorer (VE) implementing single-point, suprasystolic brachial oscillometry (SSBO) pulse wave analysis for the assessment of cfPWV and AI. Within- and between-device correlations of measured parameters were analyzed. Furthermore, agreement of repeated measurements, intra- and inter-observer concordances were determined and compared for both devices.In VI, both baPWV and cfPWV inter-correlated well and showed good level of agreement with bilateral baPWV measured by VE (baPWV[VI]-baPWV[VE]R: overall concordance correlation coefficient [OCCC] = 0.484, mean difference = 1.94 m/s; cfPWV[VI]-baPWV[VE]R: OCCC = 0.493, mean difference = 1.0 m/s). In contrast, SSBO-derived aortic PWA (cf/aoPWA[VE]) displayed only weak correlation with cfPWV(VI) (r = 0.196; P = 0.04) and ipsilateral baPWV (cf/aoPWV[VE]R-baPWV[VE]R: r = 0.166; P = 0.08). cf/aoPWA(VE) correlated strongly with AI(VE) (right-sided: r = 0.725, P < 0.001). AI exhibited marginal between-device agreement (right-sided: OCCC = 0.298, mean difference: 6.12%). All considered parameters showed good-to-excellent repeatability giving OCCC > 0.9 for 2-point-PWV modes and right-sided AI(VE). Intra- and inter-observer concordances were similarly high except for AI yielding a trend toward better reproducibility in VE (interobserver-OCCC[VI] vs [VE] = 0.774 vs 0.844; intraobserver-OCCC[VI] vs [VE] = 0.613 vs 0.769).Both diastolic oscillometry-derived PWV modes, and AI measured either with VI or VE, are comparable and reliable alternatives for the assessment of arterial stiffness. Aortic PWV assessed by SSBO in VE is not related to the corresponding indices determined by traditional diastolic oscillometry.
Topics: Diagnostic Techniques, Cardiovascular; Diastole; Feasibility Studies; Female; Humans; Male; Middle Aged; Observer Variation; Oscillometry; Reproducibility of Results; Vascular Stiffness
PubMed: 26962797
DOI: 10.1097/MD.0000000000002963 -
American Journal of Veterinary Research Nov 2021To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately...
OBJECTIVE
To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately detect hypotension in anesthetized chimpanzees (Pan troglodytes).
ANIMALS
8 captive, adult chimpanzees.
PROCEDURES
During prescheduled annual examinations, each chimpanzee underwent general anesthesia and patient monitoring for their examination, echocardiography for a concurrent study, and measurement of direct BP with the use of tibial artery catheterization and oscillometry with the use of a cuff placed around a brachium and a cuff placed around the second digit of the contralateral forelimb for the present study. Bland-Altman plots were generated to compare results for direct and oscillometric BP measurements. Mean bias and 95% LOAs were calculated for oscillometric measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) for each cuff site. Sensitivity and specificity in detecting hypotension were also determined for each cuff site.
RESULTS
There were 74 paired direct and brachial oscillometric measurements of each, SAP, MAP, and DAP and 66 paired direct and digit oscillometric measurements of each, SAP, MAP, and DAP. Only brachial oscillometric measurements of MAP had adequate sensitivity (78%) and specificity (95%) to accurately detect hypotension, and this technique also had the least mean bias (0.8 mm Hg; 95% LOA, -29 to 31 mm Hg).
CONCLUSIONS AND CLINICAL RELEVANCE
Results indicated that brachial oscillometric measurement of MAP provided reasonable agreement with tibial arterial direct MAP measurement and performed well in diagnosing hypotension in anesthetized chimpanzees.
Topics: Animals; Blood Pressure; Echocardiography; Extremities; Oscillometry; Pan troglodytes
PubMed: 34727067
DOI: 10.2460/ajvr.20.11.0194 -
The Canadian Veterinary Journal = La... Apr 2020Arterial blood pressure is a common parameter evaluated in conscious and anesthetized veterinary species. Non-invasive blood pressure measurement techniques, such as... (Review)
Review
Arterial blood pressure is a common parameter evaluated in conscious and anesthetized veterinary species. Non-invasive blood pressure measurement techniques, such as Doppler ultrasonic flow detector and oscillometry, are attractive in certain animals due to their availability and ease of use. The greatest limitation to non-invasive blood pressure monitoring can be its inaccuracy, particularly in hypotensive or hypertensive patients and in certain species. Part 1 of this 2-part review summarizes the current techniques available to non-invasively measure arterial blood pressure in animals and discusses validation of non-invasive devices. Part 2 summarizes the veterinary literature that evaluates the use of non-invasive blood pressure measurement techniques in conscious and anesthetized species and develops general conclusions for proper use and interpretation of data from non-invasive blood pressure devices.
Topics: Animals; Arterial Pressure; Blood Pressure; Blood Pressure Determination; Hypotension; Oscillometry
PubMed: 32255821
DOI: No ID Found -
Respiratory Care May 2018Impulse oscillometry is a method of airway assessment and diagnosis that provides data on lung mechanics. In the literature, studies have used different types of...
BACKGROUND
Impulse oscillometry is a method of airway assessment and diagnosis that provides data on lung mechanics. In the literature, studies have used different types of mouthpieces or did not describe the model used for the tests. We sought to compare the 3 most commonly described mouthpieces in terms of test results, comfort, and subject preference.
METHODS
Thirty-nine healthy volunteers were evaluated with spirometry and impulse oscillometry, assessing the resistance at 5 Hz and 20 Hz (R5 and R20, respectively), reactance at 5 Hz (X5), reactance area, and resonant frequency. A filter heat exchanger with a circular mouthpiece (B1), a filter heat exchanger with an oval mouthpiece (B2), and a filter heat exchanger with a circular mouthpiece coupled with a free-flow piece (B3) were compared using an acceptability and tolerance scale, and subjects noted their preference.
RESULTS
Statistical analysis showed differences between all the mouthpieces and the predicted values for R5, R20, and X5. The mouthpiece comparison showed differences in R5 between a filter heat exchanger with an oval mouthpiece (B2) and a circular mouthpiece coupled with a free-flow piece (B3) ( = .007); resonant frequency between a filter heat exchanger with a circular mouthpiece (B1) and a filter heat exchanger with an oval mouthpiece (B2) ( = .004) and between a filter heat exchanger with a circular mouthpiece (B1) and a circular mouthpiece coupled with a free-flow piece (B3) ( = .003); and reactance area between a filter heat exchanger with a circular mouthpiece (B1) and a circular mouthpiece coupled with a free-flow piece (B3) ( = .01). In the subjective evaluation, acceptability and tolerance differences were found in the ease of carrying out the evaluation, and no difference was found with regard to the degree of discomfort. Ten subjects preferred a filter heat exchanger with a circular mouthpiece (B1), 15 preferred a filter heat exchanger with an oval mouthpiece (B2), and 14 preferred a circular mouthpiece coupled with a free-flow piece (B3).
CONCLUSIONS
A circular mouthpiece coupled with a free-flow piece (B3) appeared to be the most suitable mouthpiece for the impulse oscillometry tests. It assured smaller impedance values for the respiratory system, and subjects expressed the most confidence in using this mouthpiece.
Topics: Adult; Airway Resistance; Equipment Design; Female; Healthy Volunteers; Humans; Lung; Male; Oscillometry; Respiratory Function Tests; Respiratory Mechanics
PubMed: 29487095
DOI: 10.4187/respcare.05471 -
Pulmonology 2018Tracheal stenosis is a rare and challenging disease. Bronchoscopy is the gold standard for diagnosis and assessment but brings inherent risks. Spirometry is commonly... (Comparative Study)
Comparative Study
INTRODUCTION AND OBJECTIVES
Tracheal stenosis is a rare and challenging disease. Bronchoscopy is the gold standard for diagnosis and assessment but brings inherent risks. Spirometry is commonly used to access obstructions but is not always feasible due to patient related factors. We therefore considered impulse oscillometry (IOS) as a non-invasive method to quantify airway obstruction and its potential use for diagnosis and follow-up of tracheal stenosis.
MATERIALS AND METHODS
Patients with confirmed tracheal stenosis were recruited between January 1st, 2015 and December 31st, 2016. Before bronchoscopy, all subjects underwent IOS and spirometry; for patients submitted to interventional bronchoscopy the same techniques were also performed after the procedure. We assessed the correlation between IOS measurements and airway narrowing as well as between IOS and spirometry values.
RESULTS
Twenty-one patients were included. Tracheal narrowing was inversely correlated with X5% (r -0.442, p 0.045) and positively correlated with FEV1/PEF (r 0.467, p 0.033). The stenosis length was inversely correlated with PEF and PEF% (r -0.729, p=0.001 and r -0.707, p=0.002, respectively). There was a strong correlation between spirometric and IOS values. We did not find any significant differences between pre- and post-intervention IOS values for patients assessed after interventional bronchoscopy.
CONCLUSIONS
Our study showed a weak correlation between X5% and tracheal narrowing making it unclear whether IOS can be used for physiological assessment of patients with tracheal stenosis. Stenosis length correlated with PEF making it a potential predictor of successful surgical approach. The correlation between IOS and spirometric values makes IOS a potential alternative in patients with suspected tracheal stenosis who are not able to perform spirometry. Larger scale studies should clarify the role of IOS in this pathology.
Topics: Adolescent; Adult; Aged; Bronchoscopy; Female; Humans; Male; Middle Aged; Oscillometry; Respiratory Function Tests; Spirometry; Tracheal Stenosis; Young Adult
PubMed: 29627402
DOI: 10.1016/j.pulmoe.2017.12.006 -
Anaesthesiology Intensive Therapy 2022Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP)... (Meta-Analysis)
Meta-Analysis Review
Mean arterial pressure (MAP) is a key haemodynamic variable monitored in critically ill patients. The advantages of oscillometric noninvasive blood pressure (NIBP) measurement are its easy and fast methodology; however, the accuracy and the precision of this measurement in critically ill patients is constantly debated. We performed a systematic review and meta-analysis of observational studies comparing oscillometric NIBP methods with invasive arterial pressure (IAP) measurements. We included studies of adult critically ill patients, which evaluated MAP in the same patient by both NIBP and IAP at any site. We included only studies comparing simultaneous measurements of arterial pressure by NIBP and IAP, reporting their results using mean difference and SD of agreement. The main outcome was to define the bias of the MAP measured by NIBP over the IAP measurement. The quality of the studies was analysed by the QUADAS 2 tool. Seven studies and 1593 patients were included in the main analysis. The oscillometric NIBP method had a mean value of -1.50 mmHg when compared with IAP (95% CI: -3.34 to 0.35; I2 = 96% for random effects model, P < 0.01). The limits of agreement for MAP varied between -14.6 mmHg and +40.3 mmHg. NIBP had an adequate accuracy regarding MAP measurements by oscillometry. Limits of agreement may thus narrow the clinical applicability in scenarios in which there is a need for a more precise management of blood pressure.
Topics: Adult; Humans; Blood Pressure; Blood Pressure Determination; Oscillometry; Critical Illness; Arterial Pressure
PubMed: 36734453
DOI: 10.5114/ait.2022.123120 -
Science Progress 2022Attempts to analyze respiratory function of the laryngectomized patient with tests such as spirometry and plethysmography have been described in the literature,...
Attempts to analyze respiratory function of the laryngectomized patient with tests such as spirometry and plethysmography have been described in the literature, highlighting however substantial difficulties. Oscillometry, through the forced oscillation technique (FOT), measures the mechanical properties of the respiratory system minimizing the problems related to the patient's lack of compliance. This methodology has never been applied to these patients and therefore represents a new perspective in the analysis of respiratory function.
Topics: Airway Resistance; Humans; Oscillometry; Pulmonary Disease, Chronic Obstructive; Respiratory Function Tests; Spirometry
PubMed: 35866218
DOI: 10.1177/00368504221110854 -
Paediatric Respiratory Reviews Mar 2023Premature birth is a risk factor for bronchopulmonary dysplasia (BPD); both of which are associated with obstructive airway disease throughout childhood. Impulse... (Review)
Review
Premature birth is a risk factor for bronchopulmonary dysplasia (BPD); both of which are associated with obstructive airway disease throughout childhood. Impulse oscillometry (IOS) is an effort-independent, passive measure of tidal breathing, which could have benefits in assessing lung function amongst younger patients unable to perform valid spirometry. A literature search was conducted to investigate the use of IOS in prematurely born children and young people. IOS results correlate with those of spirometry. Reversibility of airway obstruction in children with BPD is variable. IOS could have benefits in assessing individual patient response and suitability for bronchodilator therapy. More work, however, is required to establish multi-ethnic reference ranges and standardise commercially available devices prior to its routine incorporation into clinical practice.
Topics: Infant, Newborn; Humans; Child; Adolescent; Asthma; Oscillometry; Respiratory Function Tests; Spirometry; Bronchopulmonary Dysplasia; Lung
PubMed: 36270894
DOI: 10.1016/j.prrv.2022.07.003 -
Scientific Reports Aug 2019Impedance, or oscillometry, measurements of the respiratory system can generate information about the function of the respiratory system not possible with traditional...
Impedance, or oscillometry, measurements of the respiratory system can generate information about the function of the respiratory system not possible with traditional spirometry. There are currently several instruments on the market using different perturbations. We have compared a new respiratory oscillometry instrument, the tremoflo, with Impulse Oscillometry (IOS). Patients with a physician's diagnosis of chronic obstructive lung disease (COPD) and healthy subjects were recruited. They underwent assessment of respiratory function with oscillometry using the IOS and tremoflo devices and the resulting impedance data from the two methods were compared. The two devices were also tested against a reference respiratory phantom with variable resistances. Whereas both devices detected impairments in the patients' lung function commensurate with small airways pathology, the tremoflo appeared to be more sensitive than the IOS. We found systematic differences between the two instruments especially for reactance measurements where the area over the reactance curve (AX) was significantly lower with the IOS compared with the tremoflo (p < 0.001). Moreover, the agreement between the two devices was reduced with increasing severity of the disease as determined with a Bland-Altman test. Testing both instruments against a respiratory phantom unit confirmed that the resistance measured by the tremoflo compares closely with the known resistance of test loads, whereas the IOS' resistance correlated with a test load of 0.19, kPa.s.L at higher loads it deviated significantly from the known resistance (p < 0.0028). We conclude that the absolute values measured with the two devices may not be directly comparable and suggest that differences in the calibration procedures might account for the differences.
Topics: Adult; Female; Humans; Male; Middle Aged; Oscillometry; Pulmonary Disease, Chronic Obstructive; Respiratory Function Tests
PubMed: 31406190
DOI: 10.1038/s41598-019-48039-x